Gas PRODUCT SOLUTIONS

Technical Performance
Gas turbine range

The ideal solution for all applications


Alstoms gas turbines offer outstanding performance, operational and fuel flexibility
as well as availability and reliability. Alstoms gas turbines are the ideal solution for all
applications (simple-cycle, combined-cycle, co-generation etc.) and operating profiles.

Superior value from proven technology


Todays products already feature tomorrows requirements
Evolutionary product development for highly reliable products
GT26

GT24

Key benefits
Advanced-class gas turbine technology with superior part-load efficiency and operational flexibility.
Superior fuel flexibility for operating over the widest range of natural gas compositions.

GT26

GT24

TPWR/PRSHT/TPGTR/EN/10.2013/CHE/1714

Advanced-class gas turbine

Advanced-class gas turbine

Fuel

Natural Gas

Fuel

Natural Gas

Frequency

50 Hz

Frequency

60 Hz

Turbine speed

3,000 rpm

Turbine speed

3,600 rpm

Gross electrical output

326.0 MW

Gross electrical output

230.7 MW

Gross electrical efficiency

40.3%

Gross electrical efficiency

40.0%

Gross heat rate

8,933 kJ/kWh | 8,467 Btu/kWh

Gross heat rate

9,000 kJ/kWh | 8,531 Btu/kWh

Compressor pressure ratio

35.0 : 1

Compressor pressure ratio

35.4 : 1

Exhaust gas flow

692 kg/s | 1,526 Ib/s

Exhaust gas flow

505 kg/s | 1,113 Ib/s

Exhaust gas temperature

603 C | 1,117 F

Exhaust gas temperature

597 C | 1,107 F

Weight

406 t | 895,000 lb

Weight

230 t | 507,000 lb

Dimensions (LWH)

12.04.95.5 m | 391618 ft

Dimensions (LWH)

10.74.04.6 m | 351315 ft

General notes: Gas turbine gross electrical output and heat rate at the generator terminals, including gear box, where applicable
and generator losses but excluding duct and auxiliary losses. Performance calculated with 100% methane, ISO conditions. GT24/GT26
performance includes contribution of Once-Through Cooler (OTC) to water/steam cycle. Dual fuel burner option available

ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it
is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is
subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom contributes to the protection of the environment. This leaflet is printed on environmentally-friendly paper.

Gas PRODUCT SOLUTIONS


Technical performance Gas turbine Range

GT13E2

GT13E2

Conventional-class gas turbine


Configuration

2005

MXL2

2012

Fuel

Natural Gas

Natural Gas

Natural Gas

Frequency

50 Hz

50 Hz

50 Hz

Turbine speed

3,000 rpm

3,000 rpm

3,000 rpm

Gear

No

No

No

Gross electrical output

185.0 MW

188.0 MW

202.7 MW

Gross electrical efficiency

37.8%

38.6%

38.0%

Gross heat rate

9,524 kJ/kWh
9,027 Btu/kWh

9,326 kJ/kWh
8,840 Btu/kWh

9,474 kJ/kWh
8,980 Btu/kWh

Compressor pressure ratio

16.9

17.5

18.2

Exhaust gas flow

565 kg/s
1,245 lb/s

548 kg/s
1,208 lb/s

624 kg/s
1,376 lb/s

Exhaust gas temperature

505 C
941 F

512 C
954 F

501 C
934 F

Weight

343 t
756,185 lb

343 t
756,185 lb

350 t
772,000 lb

Dimensions (LWH)

11.25.45.2 m
36.717.717.0 ft

11.25.45.2 m
36.717.717.0 ft

11.05.45.5 m
361818 ft

Key benefits
Conventional-class gas turbine
technology with superior performance
and a unique flexible operation
concept. Superior fuel flexibility for
operating over the widest range of
natural gas compositions.

GT11N2

GT11N2

TPWR/PRSHT/TPGTR/EN/10.2013/CHE/1714

Conventional-class gas turbine


Fuel

Natural Gas

Natural Gas

Frequency

50 Hz

60 Hz

Turbine speed

3,610 rpm

3,600 rpm

Gear

Yes

no

Gross electrical output

113.6 MW

115.4 MW

Gross electrical efficiency

33.3%

33.9%

Gross heat rate

10,811 kJ/kWh
10,247 Btu/kWh

10,619 kJ/kWh
10,066 Btu/kWh

Compressor pressure ratio

15.9 : 1

15.9 : 1

Exhaust gas flow

400 kg/s
882 Ib/s

400 kg/s
882 Ib/s

Exhaust gas temperature

526 C
979 F

526 C
979 F

Weight

190 t
419,000 lb

190 t
419,000 lb

Dimensions (LWH)*

13.15.510.1 m
431833 ft

9.45.510.1 m
311833 ft

* Length includes the gear box


General note: Dual burner option available, as well as combustor for low
calorific gases (LBtu) such as blast furnace gases without need for enrichment.

Key benefits
Proven technology designed for
operation under harshest conditions.
Ideal for power production in steel
plants, where Blast Furnace Gas
(BFG) can be burnt directly, without
need for enrichment.

For more information


please contact Alstom Power:
Alstom Power
Brown Boveri Strasse 7
5401 Baden
Switzerland
Phone: +41 58 505 7733
Visit us online: www.alstom.com

ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it
is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is
subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Alstom contributes to the protection of the environment. This leaflet is printed on environmentally-friendly paper.