-2-
Recommended pressures of between -40 and -80mmHg are calibrated to increase and
decrease in comfortable 5mmHg increments providing a gentle massage effect
Discomfort and pain due to sudden high to low pressure spikes is virtually eliminated
Negative pressure is always maintained at the wound site because pressures never
drops to 0mmHg
-3-
-4-
TM
Before the first engineer went to work to design the Prospera PRO series of NPWT
systems, we did our homework. We reviewed the literature. We talked to countless experts.
We studied everything on the market.
What we found were difficult, unanswered issues related to pain, healing, and ease-of-use.
VARIABLE PRESSURE
THERAPY (VPT)
IN
AL
PA
IN
HE
LOWER
PRESSURE
DRESSINGS
EASE-OF-USE
ISSUES
SOLUTION
ISSUES
1
If intermittent NPWT optimizes blood flow and granulation tissue formation better than
continuous NPWT, why has continuous therapy been more frequently used?
Can intermittent NPWT be applied without sudden, jarring, and painful spikes between high
and low pressures?
What levels of negative pressure create the optimal balance of all the NPWT mechanisms of
action, while avoiding the pain and risk of ischemia associated with higher pressures (such as
the -125 mmHg commonly recommended)?
What dressing option would offer microbial control and a moist wound healing environment
without the pain and in-growth associated with other dressings, and reduce the complications
and cost associated with pain medications?
SOLUTION
A combination of system components and attributes to optimize the wound healing effects of all the
known NPWT mechanisms of action and reduce pain, while being simple to use and cost effective.
DeRoyals Prospera Advanced NPWT SolutionTM. Combining lower than traditional negative pressure
settings with Variable Pressure Therapy, and all the necessary dressings for NPWT today.
120
110
100
90
80
70
60
50
40
30
20
10
0
5 10 15 20 25 30 35
Time in minutes
TM
-5-
-6-
PRO II Series
The Portable PRO-IITM Means Quality of
Life for Your Patients
The portable PRO-II delivers all the benefits of
NPWT without pain and discomfort for the patient.
Lightweight and discreet, the PRO-II is portable and
comfortable so your ambulatory and homecare
patients can get on with their lives.
FEATURES
FEATURES
Lighter weight
BENEFITS
BENEFITS
Totally customizable
Clinical support
Cost-effective outcomes
Technical Data
Contraindications
When used for wound healing, the PRO-II is
contraindicated in the presence of:
Necrotic tissue.
Unexplored or non-enteric fistulas.
Untreated osteomyelitis.
Wounds containing malignant tissue.
Exposed arteries, veins, or organs.
Precautions
Precautions should be taken in the presence of:
Anticoagulation or active bleeding.
Difficult wound hemostasis.
Close proximity of blood vessels, organs, muscle,
and fascia requiring adequate protection.
Irradiated vessels and tissue.
Bony fragments.
Untreated malnutrition.
Non-compliance.
REIMBURSEMENT
The PRO Series of pumps are reimbursable under most third party
payer plans. Below are the Medicare HCPCS codes for the Negative
Pressure Wound Therapy System:
Code: E2402
Code: A6550
CANISTER
Code: A7000
-8-
NPWT Kits
Small Foam Kit
NP-0001 (10/Cs)
Contains:
-9-
- 10 -
1 - Measuring Device
1 - Dressing Oil Emulsion 3 x 8
1 - Sponge Kerlix AMD 2/Pk
1 - Adhesive Paste
2 - Transeal Plus 6 x 8
1 - Drain Round Perforated, 28FR
- 11 -
- 12 -
4 - Transeal Plus 8 x 12
1 - Dome Connector
1 - X-Large Foam Square (45 cm x 30 cm x 3 cm)
1 - Transeal TR 8 x 12
1 - Dome Connector
1 - Small Foam Square (10 cm x 8 cm x 3 cm)
3 - Transeal TR 8 x 12
1 - Dome Connector
1 - Large Foam Square (25 cm x 15 cm x 3 cm)
1 - Transeal Plus 6 x 8
1 - Dome Connector
1 - Dermanet Ag 4 x 4
1 - Small Foam Square (10 cm x 8 cm x 3 cm)
- 13 -
- 14 -
2 - Transeal Plus 8 x 12
1 - Dome Connector
1 - Dermanet Ag 8 x 8
1 - Medium Foam Square (20 cm x 12.5 cm x 3 cm)
3 - Transeal Plus 8 x 12
1 - Dome Connector
1 - Dermanet Ag 8 x 16
1 - Large Foam Square (25 cm x 15 cm x 3 cm)
1 - Transeal Plus 6 x 12
1 - Dome Connector
1 - Small Thin Foam Square (10 cm x 8 cm x 1.5 cm)
2 - Transeal Plus 8 x 12
1 - Dome Connector
1 - Medium Thin Foam Square (20 cm x 12.5 cm x 1.5 cm)
3 - Transeal Plus 8 x 12
1 - Dome Connector
1 - Large Thin Foam Square (25 cm x 15 cm x 1.5 cm)
- 15 -
- 16 -
2 - Transeal Plus 8 x 12
2 - White Foam Squares (6 x 6)
1 - Adhesive Paste 57 Gram Strip
1 - Tubing Set with 6-in-1 Connector
1 - Perforated Round Drain 19 FR
2 - Saline 30 ml
1 - Transeal Plus 8 x 12
1 - Dome Connector
2 - White Foam Squares (3.75 x 3.75)
2 - Saline 30 ml
1 - Measuring Device 10 cm
2 - Transeal Plus 8 x 12
1 - Dome Connector
2 - White Foam Squares (6 x 6)
1 - Saline 30 ml
1 - Measuring Device 10 cm
1 - Transeal Plus 6 x 8
1 - Dome Connector
1 - AMD Gauze Sponge 4 x 4 12-Ply
1 - Saline 30 ml
2 - Transeal Plus 8 x 12
1 - Dome Connector
1 - AMD Gauze Sponge 2/Pk
1 - Saline 30 ml
- 17 -
- 18 -
NPWT Accessories
Power Cord
PRO-II Y-Connector
PRO-III Y-Connector
Bed Rack
NP-2001 (1/Cs)
NP-120-10 (10/Cs)
NP-120 (100/Cs)
IV-Pole Holder
NP-150 (1/Cs)
NP-3001 (1/Cs)
NP-130-10 (10/Cs)
NP-130 (100/Cs)
Dome Connector
NP-160 (5/Cs)
NP-2002 (1/Cs)
NP-3002 (1/Cs)
NP-140 (1/Cs)
PRO-III Canister
Patient Tubing
NP-1007 (5/Cs)
PRO-II Canister
(250cc)
NP-1004 (30/Cs)
NP-1004-10 (10/Cs)
Black Foam
NP-200 (10/Cs)
NP-201 (10/Cs)
NP-202 (10/Cs)
- 19 -
- 20 -
DRAIN KITS
10/Cs
NP-0010
10/Cs
NP-0002
10/Cs
NP-0011
10/Cs
NP-0003
10/Cs
NP-0012
10/Cs
NP-0004
5/Cs
NP-0020
10/Cs
NP-0401
10/Cs
NP-0021
10/Cs
NP-0402
10/Cs
NP-0022
10/Cs
NP-0403
10/Cs
NP-0023
10/Cs
NP-0032
10/Cs
NP-0033
10/Cs
NP-0034
10/Cs
NP-0035
10/Cs
NP-0036
10/Cs
NP-0045
10/Cs
DOME KITS
NP-0005
10/Cs
NP-0006
10/Cs
NP-0007
10/Cs
NP-0008
5/Cs
NP-0500
10/Cs
NP-0501
10/Cs
NP-0502
10/Cs
NP-0505
10/Cs
NP-0506
10/Cs
NP-0507
10/Cs
NP-0515
10/Cs
NP-0516
10/Cs
NP-0517
10/Cs
DRAIN KITS
NP-0101
10/Cs
NP-0102
10/Cs
DOME KITS
NP-0103
10/Cs
NP-0104
10/Cs
GAUZE KITS
NP-0001
DOME KITS
UNITS
DRAIN KITS
NP-0013
10/Cs
NP-0014
10/Cs
NP-0015
10/Cs
THERAPY UNITS
NP-2000
PRO II
1/Cs
NP-3000
PRO III
1/Cs
ACCESSORIES
ACCESSORIES
NP-0000
25/Cs
NP-1111
25/Cs
NP-2001
1/Cs
NP-3001
1/Cs
NP-2002
1/Cs
NP-3002
1/Cs
NP-120
PRO II Y-Connector
100/Cs
NP-120-10
PRO II Y-Connector
10/Cs
NP-130
100/Cs
NP-130-10
10/Cs
NP-140
Bed Rack
1/Cs
NP-150
IV-Pole Holder
1/Cs
NP-160
Dome Connector
5/Cs
NP-200
10/Cs
NP-201
10/Cs
NP-202
10/Cs
NP-300
Bridge Kit
5/Cs
NP-350
Incision Kit
5/Cs
NP-325B
6 x 8 TR Transeal
100/Cs
NP-326B
8 x 12 TR Transeal
100/Cs
CANISTERS
CANISTERS
NP-1000
10/Cs
NP-1001
10/Cs
NP-1002
Filter/Tube Set
10/Cs
NP-1003
1/Cs
NP-1004
PRO II Canister
30/Cs
10/Cs
NP-1005
10/Cs
NP-1006
10/Cs
NP-1007
5/Cs
NP-1008
10/Cs
- 21 -
- 22 -
Application Videos
For further instruction on how to apply DeRoyals dome connector, and other specialty dressings,
please visit www.deroyal.com or subscribe to DeRoyals YouTube channel. Below is a complete list
of helpful tutorials:
- Application of Dressing with Dome Connector
- Application of Foam Dressing with Drain
- Application of Gauze Dressing with Dome Connector
- Continuous Pressure Therapy Mode
- Customizing Sensitivity Levels
- Operating the PRO Series Therapy Units
- Pro-II Components and Set Up
- Pro-III Components and Set Up
- Skin Prep
- Specialty Dressing Application - Bridge Dressing
- Specialty Dressing Application - Mushroom Dressing
- Specialty Dressing Appliction - Offsetting Technique
- Understanding Alarms
- Variable Pressure Therapy Mode
Step 1
Gather required supplies.
Step 2
Measure the wound and cut the
foam to the size/shape of the
wound dimensions.
Do not cut the foam over the
wound, as small fragments may fall
into the wound bed.
Dressing size should allow for the
dressing to fill wound cavity without
overlapping on the intact skin.
Step 3
Gently place the foam dressing into
the wound cavity, covering the entire
wound bed.
Do not force or forcefully push in
the foam dressing. Potential damage
to the wound may occur.
- 23 -
- 24 -
Step 4
Size and trim the Transeal to cover
the foam dressing.
Proper Transeal application is the
key to less alarm issues and loss of
seal issues.
Step 5
Peel off the release liner.
Gently press down the exposed
adhesive to the skin.
Step 6
Gently press the top of the Transeal to
ensure adhesive contact to the skin.
Step 7
When a proper seal is secured,
completely remove carrier layer
of Transeal.
Step 8
Gently lift the Transeal with your
thumb and forefinger.
Cut out a 2 - 2 cm hole in center of
foam using either scissors or scalpel.
NOTE: Do not cut a slit in the
Transeal. When NPWT is applied
slit may collapse and block the
pressure.
Step 9
Remove release liner from the dome
connector by holding the blue tab
and pulling the paper release liner.
- 25 -
- 26 -
Step 10
Place the center of the pad directly
over the cut hole or custom hole of
the foam dressing.
Step 11
Once a proper tight seal has been
accomplished, peel off the clear
backing liner from the connector.
Step 12
Peel off the blue tabs.
Pat around the dome pad to ensure
complete adhesion.
Step 13
Connect the dome pad tubing
to the end of the connector
tube attached to the canister.
NOTE: Every dome connector kit will
have an adapter included.
Step 14
Turn on the NPWT system, make
sure that the pressure is set at proper
mmHg or per doctors order.
Step 15
Once the NPWT is turned on, the foam
dressing, dome pad, and Transeal will
start to compress.
A compressed look will mean that there
is a proper seal and that the negative
pressure is reaching the wound.
- 27 -
- 28 -
Thank you for your interest in DeRoyals Negative Pressure Wound Therapy
products. We share the same passion for patient comfort, wound healing,
and ease-of-use as you do. We are confident that we can provide all the
necessary tools for you to administer the best possible care for your
patients. For more information, please contact your local
DeRoyal Wound Care representative.
Scan QR Code
to view NPWT on
www.deroyal.com