TEST REPORT
TABLE OF CONTENTS
TEST REPORT
UPGRADES
WARNING
01 050118
ED
DATE
CHANGE NOTE
B. Gorini
G.Mangili
APPRAISAL AUTHORITY
ORIGINATOR
ED
OND
01
3AL 36420 0000 QZZZA
1/2
UPGRADES
EDITION
01
DATE
CHANGE NOTE
18/01/2005
First edition
WARNING
This page and the previous one are not part of the original document. They have been added to give a
formal structure to the document provided by the EMC Laboratory.
The original document starts on the next page.
END OF DOCUMENT
ED
OND
01
3AL 36420 0000 QZZZA
2/2
ALCATEL ITALIA
EMI-EMC LABORATORY
TR/EMC/02/067
Applicant:
Report
Alcatel
Via Trento 30 20059 Vimercate
N of original distributed: 2
This report may be reproduced in full or partially only with the written consent of the Laboratory.
The test results in this report apply only to the sample(s) tested.
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
2/31
SUMMARY
This report is concerning the EMC characteristics of the equipment 1660SM Rel.5.2B, cod. 3AL 81407 ACAA
manufactured by Alcatel.
The equipment has been tested with reference to the following harmonised standard to demonstrate the
conformity to the protection requirements of the council directive 89/336 EEC, according to the article 10.1:
-
ETSI EN 300386 V1.3.2 (Ed. 05/2003) for transmission equipment, location "TELECOMMUNICATION
CENTRES".
Additional measurements have been performed, as requested by the customer, in accordance to the following
voluntary requirements:
CISPR/I/105/CDV (ed. 2004)
CISPR/I/106/CDV (ed. 2004)
for radiated emission above 1GHz (Frequency range test: 1 - 18 GHz).
ETSI ES 201468 v1.2.1 (ed. 09/2002):
location " TELECOMMUNICATION CENTRES " "LEVEL 2" for immunity requirements.
The test performed, the reference basic standards and the results are summarised in the paragraph 7.
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
3/31
CONTENTS
1
SCOPE ...........................................................................................................................................................................................5
CONCLUSIONS ...........................................................................................................................................................................5
IMMUNITY TESTS.................................................................................................................................................................. 15
6.1 PERFORMANCE CRITERIA OF SIGNAL INTERFACE .................................................................................................. 15
6.2 RADIATED IMMUNITY TESTS (80MHZ2GHZ) ............................................................................................................ 16
6.2.1 Test specification, methods and procedures.................................................................................................................. 16
6.2.2 Test configuration .......................................................................................................................................................... 16
6.2.2.1
6.2.2.2
6.2.2.3
6.2.2.4
ALCATEL ITALIA
EMI-EMC LABORATORY
6.2.2.5
6.2.2.6
Report
Pag.
TR/EMC/02/067
4/31
6.4.1.1
Test specification, methods and procedures ..............................................................................................................................19
6.4.1.2
Test configuration ...................................................................................................................................................................... 19
6.4.1.2.1 Environmental conditions: ................................................................................................................................................... 19
6.4.1.2.2 Operating voltage: ................................................................................................................................................................ 19
6.4.1.2.3 Operating mode: ................................................................................................................................................................... 19
6.4.1.2.4 Line attenuation: ................................................................................................................................................................... 19
6.4.1.2.5 Support equipment: .............................................................................................................................................................. 20
6.4.1.2.6 Cable lengths: ....................................................................................................................................................................... 20
6.4.1.3
Tests results................................................................................................................................................................................20
6.5.3
6.5.4
7
Tested points................................................................................................................................................................... 22
Tests results .................................................................................................................................................................... 22
ALCATEL ITALIA
EMI-EMC LABORATORY
1
Report
Pag.
TR/EMC/02/067
5/31
SCOPE
The EMC tests were performed on the 1660SM Rel.5.2B, to demonstrate the compliance with the protection
requirements of the Council Directive 89/336 EEC Article 10.1.
The protection requirements for this type of equipment are covered by the following standards:
ETSI EN 300386 V1.3.2 (Ed. 05/2003) for transmission equipment, location "TELECOMMUNICATION
CENTRES".
Additional measurements have been performed, as requested by the customer, in accordance to the following
voluntary requirements:
CISPR/I/105/CDV (ed. 2004)
CISPR/I/106/CDV (ed. 2004)
for radiated emission above 1GHz (Frequency range test: 1 - 18 GHz).
ETSI ES 201468 v1.2.1 (ed. 09/2002):
location " TELECOMMUNICATION CENTRES " "LEVEL 2" for immunity requirements.
2 CONCLUSIONS
The tests performed, the reference standards and the test results are summarised in the paragraph 7.
Details on each test are described in the relevant paragraphs.
ALCATEL ITALIA
EMI-EMC LABORATORY
3
Report
Pag.
TR/EMC/02/067
6/31
Code
Pos.
3AL78834AAAE
3AL79088ACAA
3AL78817AAAF
3AL78836ABAA
3AL81289AAAA
3AL89669AAAA
3AL81427AAAA
3AL81915AAAA
3AL80411ABAA
3AL89668AAAA
3AL81348AAAA
3AL81344AEAA
3AL81346ACAA
3AL81072AAAC
3AL78830ADAA
1AB194670001
1AB196360001
1AB196370001
1AB196370004
1AB196350002
11
22
33
8
34
37
18
29-30
2-3
15-16
13-14
23-40
10-12
8-30
29
34
33-34
34
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
7/31
3AN49397AAAA
1-9-17-21-26-27
28-31-32-41
3AN49589AAAA
4-5,6-7,13-14
15-16,19-20,24-25,35-36,38-39
FAN SHELF 19
Code
N1 FAN SHELF 19
N4 FAN UNIT FOR SHELF 19
N2 ANTI-DUST FILTER FOR SHELF 19
3AL79773AAAA
3AL79772AAAC
3AL80371AAAB
ALCATEL ITALIA
EMI-EMC LABORATORY
4
Report
Pag.
TR/EMC/02/067
8/31
REFERENCE STANDARDS
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
9/31
ALCATEL ITALIA
EMI-EMC LABORATORY
5
Report
Pag.
TR/EMC/02/067
10/31
EMISSION TESTS
EN 55022 [Reference 1]
EN 55022 [Reference 1]
Test method:
The test was performed according to EN 55022. The worst emission was searched with several cables position.
The receiving antenna was placed at distance of 10 m from the EUT border with scanning in height from 1 to 4 m.
The EUT was turned from 0 to 360.
The test was performed in the semi-anechoic chamber whose characteristics are reported in the paragraph 9.
Test lay out:
The EUT was placed on an isolated table at 0.1m from ground floor.
The EUT configuration was provided by the customer. The ports were connected with the cables specified in the
product Technical Description (3AL 78911 0758 DSBUF).
The test lay out is in the Annex 2, figure B.
5.1.2
Test configuration
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
11/31
Code
Length
N 2
cables
041.931.031
2.5 m
041.931.031
2.5 m
GB Ethernet interface
Optical interface STM-1
Optical interface STM-4
Optical interface STM-16
Ground connection
shielded
N 5 optical
mode
N 17 optical
mode
N 5 optical
mode
N 5 optical
mode
bipolar
fibres multi
fibres single
fibre single
fibre single
N 1 cable
Polarisation
Horizontal
Vertical
Horizontal and Vertical
uncertainty
+4.2dB / -4.1dB
+4.5dB / -4.4dB
3.6dB
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
12/31
Test specifications:
- the test limits are defined in:
Test method:
The test was performed according to the CISPR/I/105/CDV and CISPR/I/106/CDV with the receiving antenna
placed at a distance of 3m from the border of the EUT. The antenna was a double-ridged, with peak-detector
(1MHz of resolution bandwidth) as requested by the CISPR/I/105/CDV and CISPR/I/106/CDV. This test was
performed with antenna height of 1m and turning the EUT from 0 to 360.
The test was performed in the semi-anechoic chamber whose characteristics are reported in the paragraph 9.
Additional RF absorber were placed on the floor to guarantee free-reflection conditions as requested by the
reference document.
Test lay out:
The EUT was placed on an isolated table at 0.1m from ground floor.
The EUT configuration was provided by the customer. The ports were connected with the cables specified in the
product Technical Description (3AL 78911 0758 DSBUF).
The test lay out is in the Annex 2, figure C.
5.2.2
Test configuration
ALCATEL ITALIA
EMI-EMC LABORATORY
5.2.3
Report
Pag.
TR/EMC/02/067
13/31
Tests results
The test result is in COMPLIANCE to the requirements of the documents CISPR/I/105/CDV and
CISPR/I/106/CDV as the emissions are under the peak and the average limits (peak detector) with a margin higher
than the uncertainty interval.
The uncertainty interval, based on the 95% level of confidence (determined with the procedure N
8BP400500016URBUF, Annex 1, of this laboratory based on the document CISPR 16-4), is:
frequency range
frequency range
frequency range
frequency range
+2,7dB / -2,8dB
+3,4dB / -3,6dB
+4.2dB / -4.8dB
+4.2dB / -4.5dB
The maximum emissions are shown in the graphs in Annex 1, figure 1.3 .
For test instrumentation and their uncertainties, see paragraph 8.
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
14/31
EN 55022 [Reference 1]
EN 55022 [Reference 1]
Test method:
The test was performed with the LISN (Line Impedance Stabilisation Network) defined in the EN 55022
[Reference 1].
Test lay out:
The EUT configuration was provided by the customer. The ports were connected with the cables specified in the
product Technical Description (3AL 78911 0758 DSBUF).
The test lay out is in the Annex 2, figure D.
5.3.1.2 Test configuration
5.3.1.2.1 Environmental conditions:
Temperature 21C, Humidity 51%
5.3.1.2.2 Operating voltage:
The EUT input voltage was -48VDC
5.3.1.2.3 Operating mode:
See paragraph 5.1.2.3.
5.3.1.2.4
None
Line attenuation:
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
15/31
IMMUNITY TESTS
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
16/31
Test specification:
- the test levels are defined in:
- the test method is defined in:
[Reference 8]
[Reference 9]
EN 61000-4-3
EN 61000-4-3/A1
[Reference 3]
[Reference 3a]
Test method:
The test method applied is defined in the basic standard EN 61000-4-3+A1.
The graphs concerning the field distribution on the 16 points defined by the standard EN 61000-4-3 are available
by this laboratory.
The distance between the antennas and the centre of the volume occupied by the EUT was 3m.
The field calibration was performed without modulation of the signal, whereas the test was carried out with 80%
AM modulated with 1kHz. The frequencies increment steps were 1% of the fundamental.
The EUT performances are assessed by monitoring the ports defined in the paragraph 6 of this report.
Test lay out:
The EUT configuration was provided by the customer. The ports were connected with the cables specified in the
product Technical Description (3AL 78911 0758 DSBUF).
The test lay out is in the Annex 2, figure E for the frequency range 80MHz-1000MHz, and figure F for the
frequency range 1GHz-2GHz.
6.2.2
Test configuration
ALCATEL ITALIA
EMI-EMC LABORATORY
6.2.3
Report
Pag.
TR/EMC/02/067
17/31
Tests results
The EUT operated correctly as intended without signal and software degradation.
The test result is in COMPLIANCE with the performance Criterion A for interference level of 10V/m, as
requested by the standard ETSI EN 300386 v1.3.2 and the document ETSI ES 201468 v1.2.1 for voluntary
requirements (Level 2 for TLC centres).
The field was calibrated in horizontal and vertical polarisation with field intensity of 0/+6dB on the nominal
value. The reading uncertainty of the field sensor is:
HORIZONTAL POSITION
frequency range 80MHz - 2000MHz
2.0dB
VERTICAL POSITION
frequency range 80MHz - 2000MHz
2.0dB
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
18/31
EN 61000-4-8
[Reference 7]
Test method:
The calibration of the interfering magnetic field was carried out in absence of the EUT, using a magnetic field
meter placed in the centre of the induction coil. The magnetic field was calibrated in order to guarantee the field
intensity level requested. The interfering field was applied to the EUT by the immersion method (according to the
sub-clause 4.4 of the basic standard), placing the coil on each orthogonal axis.
The EUT performances are assessed by monitoring the ports defined in the paragraph 6 of this report.
Test lay out:
The test lay out is in the Annex 2, figure G.
6.3.1.2 Test configuration
6.3.1.2.1 Environmental conditions:
Temperature 21C, Humidity 50%
6.3.1.2.2 Operating voltage:
The EUT input voltage was -48VDC
6.3.1.2.3 Operating mode:
See paragraph 5.1.2.3.
6.3.1.2.4
None
Line attenuation:
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
19/31
Date of tests:
ETSI EN 300386
ETSI ES 201 468
[Reference 8]
[Reference 9]
Line attenuation:
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
20/31
1.6 dB
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
21/31
Test specification:
- the test limits are defined in:
EN 61000-4-2 [Reference 2]
Test method:
The EUT was tested with the following methods:
Direct discharges: the direct discharges were applied to the points and surfaces of the EUT that are
accessible to personnel during normal usage.
Each accessible point was tested with 10 discharges with positive polarity and 10 discharges with negative
polarity. Air discharges were applied on not conductive points, while contact discharges were applied on
conductive points according to the sub-clause 8.3.1 of the basic standard EN61000-4-2.
Indirect discharges: according to the sub-clause 8.3.2 of the basic standard EN61000-4-2, the ESD were
applied to a vertical coupling plane through a contact discharge adapter. The vertical coupling plane (0.5m x
0.5m dimensions) was placed parallel to, and positioned at a distance of 0.1m, from each side of the EUT.
On each side of the EUT were applied 10 discharges with positive polarity and 10 discharges with negative
polarity.
The ESD were not applied to pins of non-cabled connectors and to local monitoring ports as these are protected
by proper caps.
The EUT performances are assessed by monitoring the ports defined in the paragraph 6 of this report.
Test lay out:
The test lay out is in the Annex 2, figures L and M.
6.5.2
Test configuration
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
22/31
INDIRECT DISCHARGES
- Vertical coupling plane.
ALCATEL ITALIA
EMI-EMC LABORATORY
7
Report
Pag.
TR/EMC/02/067
23/31
BASIC
STANDARDS
AC POWER CABLES
0,15 MHZ-30 MHz
EN 55022
DC POWER PORTS
0,15 MHZ-30 MHz
EN 55022
TELECOMMUNICATION
PORTS
EN 55022
HARMONICS
AC POWER PORTS
EN 61000-3-2
VOLTAGE
FLUCTUATION
AC POWER PORTS
EN 61000-3-3
PLANE WAVE
30 MHz - 1 GHz
EN 55022+A1
CONDUCTED
EMISSIONS
RADIATED
EMISSIONS
REQUIREMENTS
Required in the
EN 300386 V1.3.2
Par.6.1
Limits defined in the
EN 55022 Tab.2
Required in the
EN 300386 V1.3.2
Par.6.1
Limits defined in the
EN 55022 Tab.2
Required in the
EN 300386 V1.3.2
Par.6.1
Limits defined in the
EN 55022 Tab.4
Required in the
EN 300386 V1.3.2
par.6.1
Requirements
See basic std.
Required in the
EN 300386 V1.3.2
par.6.1
Requirements
See basic std.
Required in the
EN 300386 V1.3.2
Par.6.1
Limits defined in the
EN 55022 Tab.6
COMPLIANCE
CLASS
FIG. RESULT
GRAPHS
NOTE
N.A.
N.A.
2)
COMPLIANCE
N.A.
N.A.
N.A.
N.A.
2)
N.A.
N.A.
2)
COMPLIANCE
1)
NOTE:
1) In the configuration of the apparatus under test has been applied the standard EN 55022/A1 (ed.10/2001),
requested for floor-standing equipment; about other tests we referred to the standard EN 55022 (ed.09/98).
2) N.A: Not Applicable because the apparatus is DC power supply.
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
24/31
ELECTROSTATIC
DISCHARGES (ESD)
EN 61000-4-2
ELECTRICAL
FAST
TRANSIENT
(EFT)
SURGES
CONDUCTED
IMMUNITY
CW
(0.15-80 MHz)
EN 61000-4-3+A1
TEST LEVEL
REF.
COMPL.
CRITER.
RESULT
COMPL.
CRITER.
REQUIREMENTS
RESULTS
4 kV cont.
4 kV air
4 kV cont.
4 kV air
COMPLIANCE
B
B
A
A
80-800MHz 3 V/m
800-960MHz 10 V/m
960-1000MHz 3 V/m
1.4-2.0GHz 10 V/m
10 V/m
10 V/m
10 V/m
10 V/m
COMPLIANCE
A
A
A
A
A
A
A
A
NOTE
AC POWER
PORTS
EN 61000-4-4
1.0 kV
N.A.
N.A.
DC POWER
PORTS
EN 61000-4-4
0.5 kV
0.5 kV
COMPLIANCE
INDOOR SIGNAL
CABLES
EN 61000-4-4
0.5 kV
N.A.
N.A.
3)
OUTDOOR
SIGNAL CABLES
EN 61000-4-4
0.5 kV
N.A.
N.A.
1)
EN 61000-4-5
0.5 kV
N.A.
N.A.
3)
EN 61000-4-5
1.0 kV
N.A.
N.A.
1)
N.A.
B
B
N.A.
2)
N.A.
B
C
C
N.A.
2)
INDOOR SIGNAL
CABLES
1.2s/50s
OUTDOOR
SIGNAL CABLES
1.2s/50s
AC POWER
PORTS
1.2s/50s
VOLTAGE DIPS
and
SHORT
INTERRUPTIONS
BASIC
STANDARDS
EN 61000-4-5
2)
AC POWER
PORTS
EN 61000-4-11
POWER CABLES
(DC)
EN 61000-4-6
3V
3V
COMPLIANCE
POWER CABLES
(AC)
EN 61000-4-6
3V
N.A.
N.A.
2)
OUTDOOR
SIGNAL CABLES
EN 61000-4-6
3V
N.A.
N.A.
1)
INDOOR SIGNAL
CABLES
EN 61000-4-6
3V
N.A.
N.A.
3)
NOTE:
1) N.A.: Not Applicable because no cable is considered "OUTDOOR SIGNAL LINE".
2) N.A.: Not Applicable because the apparatus is DC power supply.
3) N.A.: Not Applicable because no cable is considered "INDOOR SIGNAL LINE".
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
25/31
Reference document: CISPR/I/105/CDV and CISPR/I/106/CDV (ed. 2004) Location: TLC Centres
PHENOMENON
RADIATED
EMISSIONS
PLANE WAVE
1 GHz -18 GHz
BASIC
STANDARDS
REQUIREMENTS
COMPLIANCE
CLASS
FIG. RESULT
GRAPHS
CISPR/I/105/CDV
CISPR/I/106/CDV
Limits defined in
table 7
COMPLIANCE
Tab.7
Fig. 1.3
NOTE
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
26/31
BASIC
STANDARDS
TEST LEVEL
REQUIREMENTS
RESULTS
6 kV cont.
8 kV air
COMPLIANCE
ELECTROSTATIC
DISCHARGES (ESD)
EN 61000-4-2
6 kV cont.
8 kV air
EN 61000-4-3
10 V/m
POWER FREQUENCY
MAGNETIC FIELD
EN 61000-4-8
AC POWER PORTS
DC POWER PORTS
RESULT
REF.
COMPL. COMPL. NOTE
CRITER. CRITER.
B
B
A
A
10 V/m
COMPLIANCE
3 A/m (rms)
30 A/m (rms)
COMPLIANCE
EN 61000-4-4
2.0 kV
N.A.
N.A.
EN 61000-4-4
1.0 kV
1.0 kV
COMPLIANCE
EN 61000-4-4
1.0 kV
N.A.
N.A.
4)
EN 61000-4-4
1.0 kV
N.A.
N.A.
1)
EN 61000-4-5
0.5 kV
N.A.
N.A.
4)
EN 61000-4-5
1.0 kV)
N.A.
B
B
N.A.
1)
ITU-T K20
4.0 kV
1.0 kV
N.A.
R
R
N.A.
1)
AC POWER
PORTS 1.2s/50s
EN 61000-4-5
N.A.
B
B
N.A.
3)
PERMANENT
POWER
INDUCTION
OUTDOOR
SIGNAL
CABLES
ITU-T K54
N.A.
N.A.
1)
POWER
INDUCTION
OUTDOOR
SIGNAL
CABLES
ITU-T K20
600 V,
200 ms,
50 Hz
N.A.
N.A.
1)
2)
AC POWER PORTS
EN 61000-4-11
>95% 10 ms
30% 500 ms
>95% 5000ms
N.A.
B
C
C
N.A.
3)
AC POWER PORTS
EN 61000-4-6
10 V
N.A.
N.A.
3)
DC POWER PORTS
EN 61000-4-6
10 V
10 V
COMPLIANCE
OUTDOOR SIGNAL
CABLES
EN 61000-4-6
10 V
N.A.
N.A.
1)
INDOOR SIGNAL
CABLES
EN 61000-4-6
10 V
N.A.
N.A.
4)
ELECTRICAL
FAST
TRANSIENT
(EFT)
INDOOR SIGNAL
CABLES
OUTDOOR SIGNAL
CABLES
INDOOR SIGNAL
CABLES 1.2s/50s
OUTDOOR
SIGNAL LINES
1.2ms/50ms
(10ms/700ms for ITUT K20)
SURGES
CONDUCTED
IMMUNITY CW
(0.15-80 MHz)
NOTE:
60 V,
15 min,
2
3)
50/16 /3 Hz
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
27/31
TEST INSTRUMENTATION
7.5 Radiated emission tests
These tests were carried out in the semi-anechoic chamber, see paragraph 9 for characteristics.
Test instrumentation (30-1000 MHz):
-
INSTRUMENT
SPECTRUM ANALYZER .100Hz-22GHz
PRESELECTOR 20Hz-2GHz
QP ADAPTER 9kHz-1GHz
BICONICAL ANTENNA
LOG PERIODIC ANTENNA
PRE AMPLIFIER
PRE AMPLIFIER
COAXIAL CABLE
COAXIAL CABLE
COAXIAL CABLE
MODEL
HP 8566B
HP 85685A
HP 85650A
EMCO 3108
EMCO 3146
HP 8447D
ELECTRO-METRICS BPA-1000
ALCATEL CODE
16712A04
19816A00
16642A00
L98DC001
L98CZ003
L05CC001
L05CY002
CAVO 1
CAVO 6
CAVO 7
MODEL
HP 8566B
HP 85685A
HP 85650A
ELECTRO-METRICS RGA-60
BONN.BLMA 0118-1A
ALCATEL CODE
16712A04
19816A00
16642A00
L98HXV01
404604600
CAVO 41
CAVO 42
INSTRUMENT
SPECTRUM ANALYZER .100Hz-22GHz
PRESELECTOR 20Hz-2GHz
QP ADAPTER 9kHz-1GHz
DOUBLE-RIDGED ANTENNA
LOW NOISE PREAMPLIFIER.1-18 GHz.
COAXIAL CABLE
COAXIAL CABLE
SPECTRUM ANALYSER
BICONICAL ANTENNA
LOG PERIODIC ANTENNA
COAXIAL CABLES
Amplitude accuracy
Calibration accuracy
Calibration accuracy
Calibration accuracy
= 1dB
= 0.9dB
= 1dB
= 1.1dB
= 0.8dB
= 1.4dB
= 2.2dB
= 2.5dB
= 0.8dB
= 1.1dB
INSTRUMENT
SPECTRUM ANALYZER .100Hz-22GHz
PRESELECTOR 20Hz-2GHz
QP ADAPTER 9kHz-1GHz
V-NETWORK LISN
COAXIAL CABLE
COAXIAL CABLE
INSTRUMENTATION UNCERTAINTY:
- SPECTRUM ANALYSER
- V-NETWORK LISN
- COAXIAL CABLES
MODEL
HP 8566B
HP 85685A
HP 85650A
R&S ESH 3-Z5
ALCATEL CODE
16712A04
19816A00
16642A00
L65AT002
CAV 53
CAV 56
Amplitude accuracy
= 1dB
Tolerance on the impedance curve = 20%
Calibration accuracy
= 1.1dB
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
28/31
INSTRUMENT
CW GENERATOR
POWER AMPLIFIER
POWER AMPLIFIER
BICONICAL ANTENNA
LOG PERIODIC ANTENNA
FIELD PROBE
COAXIAL CABLE
COAXIAL CABLE
MODEL
MARCONI 2030
IFI M406
AR 200W 1000M7A
EMCO 3109
EMCO 3146
HOLIDAY FP 3000
ALCATEL CODE
VI610612
L05CU001
VI615395
403754900
L98CZ002
L40DN001
CAV 19
CAV 21
MODEL
HP 83620A
HP 438A
LOGIMETRICS A610/L
LOGIMETRICS MICROPROCESSOR
LOGIMETRICS AN 8200 C
AR FP 2080
AR FM 2000
ALCATEL CODE
L34N2V01
L28BRD03
VI615398
VI616753
VI616752
VI616749
VI616745
CAV 32
CAV 33
INSTRUMENT
SYNTHESISED SWEEPER
POWER METER
POWER TWT AMPLIFIER
CONTROL UNIT
HORN ANTENNA
ISOTROPIC FIELD PROBE
ISOTROPIC FIELD MONITOR
COAXIAL CABLE
COAXIAL CABLE
MODEL
HOLADAY HI-3627 3-AXIS
DANA DAS-G 120
DANA DAS-S 120 (dimension 1x1 m)
ALCATEL CODE
VI623764
VI616422
INSTRUMENTATION UNCERTAINTY:
- MAGNETIC FIELD METER
Calibration accuracy (at the calibration frequency) = 5%
(According to EN 61000-4-8 requirements: < 8%)
ALCATEL ITALIA
EMI-EMC LABORATORY
Report
Pag.
TR/EMC/02/067
29/31
INSTRUMENT
EFT GENERATOR
COUPLER/DECOUPLER
HIGH VOLTAGE PROBE
OSCILLOSCOPE
COAXIAL CABLE
INSTRUMENTATION UNCERTAINTY:
- EFT GENERATOR
- (Open circuit voltage)
- OSCILLOSCOPE
MODEL
EM TEST EFT 500
EM TEST CNI 503
TEKTRONIX P6015A
TEKTRONIX 620A
ALCATEL CODE
VI624893
VI624893
L60C7V03
L35GBV01
CAV 51
Rise time
Pulse duration
Burst period
Vertical accuracy
Time base accuracy
= CHARACTERISTICS ACCORDING
= TO EFT IMMUNITY TEST
= (EN61000-4-4)
= 1%
= 0,01%
MODEL
8662A Agilent
AR 75A250
E 4419B
Agilent E4419B
801-M2-25 FCC
SCHAFFNER CSP 8455
WEINSCHEL CORP 341034
WEINSCHEL CORP 341034
ALCATEL CODE
L34PJV01
VI615396
L28MQV02
L28MQV02
VI605532
403749300
BJ7046
BJ7047
CAV 14
Calibration Accuracy
Calibration Accuracy
= 2.0dB
= 1.1dB
INSTRUMENT
SYNTHESISED GENERATOR
POWER AMPLIFIER
POWER METER
POWER METER
CDN 2 pole 25A, freq.150kHz230MHz
CURRENT PROBE (monitoring probe)
ATTENUATOR (10dB)
ATTENUATOR (10dB)
COAXIAL CABLE
INSTRUMENTATION UNCERTAINTY:
- CDN 2 pole 25A 801-M2-25 FCC
- COAXIAL CABLE
ALCATEL CODE
L34NLV01
= 10%
ALCATEL ITALIA
EMI-EMC LABORATORY
8
Report
Pag.
TR/EMC/02/067
30/31
The chamber is a ground reflection design without absorber on the working floor surface.
Thus, the chamber test environment can be related to an open area reflection test site. The site attenuation of the
chamber is available in this laboratory.
The test room is completed with the turntable and the antenna position mast.
Measurement instrumentation is located in a shielded control room.
For radiated immunity test the field uniformity is guaranteed over 75% of surface (1.5m x 1.5m, 0.8m above
ground plane) with 42 pcs of ferrite plate absorber, installed on floor.
8.2 THREE METERS FULLY ANECHOIC CHAMBER
The test site is a shielded fully anechoic chamber with the following
characteristics:
Internal size: 6.42m (l) x 3.97m (w) x 4.05m (h)
RF attenuation in accordance to MIL STD 285
magnetic field 50dB at 10kHz, 60dB at 100kHz
electric field > 90dB
plane wave > 90dB up to 1GHz
For radiated emission test (frequency range 1-18 GHz) additional absorbers were placed on the floor in order to
rely on free-reflection conditions, as requested by the reference document.
For radiated immunity test (frequency range 1-2 GHz) the field uniformity is guaranteed over the 75% of the
surface (1.5m x 1.5m, 0.8m above ground plane) with additional absorbers, installed on the floor.
The site attenuation of the chamber is available in this laboratory.
The test room is completed with the turntable and the antenna position mast.
Measurement instrumentation is located in a shielded control room.
ALCATEL ITALIA
EMI-EMC LABORATORY
9
Report
Pag.
TR/EMC/02/067
31/31
ANNEX CONTENTS
ALCATEL ITALIA
EMI-EMC LABORATORY
ANNEX 1
Annex 1
Pag.
TR/EMC/02/067
1/3
MEASUREMENT GRAPHS
ALCATEL ITALIA
EMI-EMC LABORATORY
Annex 1
Pag.
TR/EMC/02/067
2/3
Fig. 1.4
ALCATEL ITALIA
EMI-EMC LABORATORY
Fig. 1.5
Annex 1
Pag.
TR/EMC/02/067
3/3
ALCATE ITALIA
EMI-EMC LABORATORY
ANNEX 2
Fig. A
Annex 2
Pag.
TR/EMC/02/067
1/6
ALCATE ITALIA
EMI-EMC LABORATORY
Fig. B
Fig. C
Annex 2
Pag.
TR/EMC/02/067
2/6
ALCATE ITALIA
EMI-EMC LABORATORY
Fig. D
Annex 2
Pag.
TR/EMC/02/067
3/6
Fig. E
ALCATE ITALIA
EMI-EMC LABORATORY
Fig. F
Fig. G
Annex 2
Pag.
TR/EMC/02/067
4/6
ALCATE ITALIA
EMI-EMC LABORATORY
Annex 2
Pag.
TR/EMC/02/067
5/6
Fig. H
Fig. I
ALCATE ITALIA
EMI-EMC LABORATORY
Fig. L
Fig. M
Annex 2
Pag.
TR/EMC/02/067
6/6
TEST LAY OUT: Electrostatic discharge (indirect method) vertical coupling plane