Professional Documents
Culture Documents
Refrigeration Orrifice Selection Chart PDF
Refrigeration Orrifice Selection Chart PDF
2) Assemble the orifice and valve body and install into system
T2 type expansion valves are designed for flare connections. To make a functioning valve,
pair the appropriate valve body and orifice using the charts below.
IF THE EXACT SYSTEM CAPACITY CANNOT BE FOUND, USE THE NEXT LARGER ORIFICE.
R22
Valve Body
TX 2
068Z3206
TEX 2
068Z3209
Orifice
Size
Code
Number
45
0x
068-2002
00
068-2003
01
068-2010
02
068-2015
1/10
1/8
1/6
1/4
1/2
3/4
1
03
068-2006
04
05
06
068-2007
068-2008
068-2009
3
4
5
Orifice
Size
Code
Number
45
0x
068-2002
00
068-2003
01
068-2010
02
068-2015
03
068-2006
35
25
0
-10 -20 -30
Rated Capacity in Tons (TR)2
1/10 1/10 1/10 1/10 1/10 1/10
1/8 1/8 1/8 1/8 1/8 1/8
1/6 1/6 1/6 1/6 1/6 1/6
1/4 1/4 1/4 1/4 1/4 1/4
1/2 1/2
1/2 1/2 1/2 1/4
3/4 3/4
1
1
3/4 3/4 3/4 1/2
1
3/4
2
2
1
1
1 1/2
1
3
3
2
2
2 1 1/2
4 3 1/2 3 2 1/2 2 1/2 2
5 4 1/2 3 1/2 3
3 2 1/2
R404A / R507
1
Valve Body
TS2
068Z3400
TES 2
068Z3403
Valve Body
35
25
0
-10 -20 -30
Rated Capacity in Tons (TR)2
1/10
1/10 1/10
1/8
1/6 1/8 1/8
1/4 1/6 1/6
1/4
1/2
1/4
1/2
3/4 1/2 1/2
3/4 3/4
1
1
1
068-2007
05
06
068-2008
068-2009
2 1/2
3
2
3
Orifice
Size
Code
Number
45
35
0x
068-2002
00
068-2003
01
068-2010
1/2
02
068-2015
3/4
03
068-2006
04
05
06
068-2007
068-2008
068-2009
2
2 1/2
3
26-33 ft-lb
(35-45Nm)
1/4
1/2
3/4
1
1 1/2
2
2 1/2
-40
Superheat Adjustment
1) Remove the cap.
2) Make superheat adjustments turn at a time (1 turn=7F). Turning clockwise
increases superheat. Turning counter-clockwise decreases superheat.
3) Reinstall the cap.
1/8
1/6
1/8
1/6
1/8 1/10
1/6 1/8
1/4
1/4
1/4
1/4
1/6
1/2
1/4
1/2
3/4
1/4
1/4
1/4
1/2
1/2
1/2
3/4
3/4
1 1/2 1
1
3/4
1
2 1 1/2 1 1/2 1
1
2 1/2 2 1 1/2 1 1/2 1
04
Torque Requirements
3/4
1
1
1/10
1/8
1/6
1/4
R134a
TN 2
068Z3346
TEN 2
068Z3348
1/10
1/8
1/6
1/4
25
0
-10 -20 -30
Rated Capacity in Tons (TR)2
1/10 1/10
1/10 1/10 1/10 1/10
1/8 1/8
1/6 1/6 1/6 1/6
1/6 1/6
1/8 1/8 1/8 1/8
1/4
1/4 1/4 1/4 1/4 1/6
1/2
1/2 1/2 1/2 1/4 1/4 1/4
1/2
3/4 1 3/4 1 3/4
1/2 1/2
3/4
1 1/2 1 1/2 1
1
3/4 3/4
2
2 1 1/2 1
1
1
2 1/2 2 1/2 2 1 1/2 1 1/2 1
-40
1/10
1/6
1/8
1/6
1/4
1/2
3/4
1
1
Valve Body - Internal: 3/8" X 1/2" ODF - External: 3/8" X 1/2" w/ 1/4" ODF Equalizer
Capacities are based on a condensing temperature of 90 F and a vapor free liquid temperature of 80 F ahead of the expansion valve.
DANFOSS CODE
R22
REFRIGERANT
R404a
R134a
CAPACITY IN KW
T2-0X
T2-00
T2-01
T2-02
T2-03
T2-04
T2-05
T2-06
068-2002
068-2003
068-2010
068-2015
068-2006
068-2007
068-2008
068-2009
0.5
1
2.5
3.5
5.2
8
10.5
15.5
0.38
0.7
1.6
2.1
4.2
6
7.7
9.1
0.4
0.95
1.8
2.6
4.6
6.7
8.6
10.5
T5-01
T5-02
T5-03
T5-04
067B2089
067B2090
067B2091
067B2092
19.7
26.9
38.8
55.3
13
17.6
25.3
36.2
12.9
19.1
29.1
39.6
T12-01
T12-02
T12-03
T12-04
067B2005
067B2006
067B2007
067B2008
26.8
43.4
64
84.4
14.8
23.9
35.2
47.1
16.7
27.2
40
53
T20-01
T20-01
T20-01
067B2170
067B2172
067B2175
108
108
108
59
59
59
65
65
65
T55-01
T55-02
067G2001
067G2002
239
356
130
197
145
220
TUA-00
TUA-01
TUA-02
TUA-03
TUA-04
TUA-05
TUA-06
TUA-07
TUA-08
TUA-09
068U1030
068U1031
068U1032
068U1033
068U1034
068U1035
068U1036
068U1037
068U1038
068U1039
0.6
0.9
1.3
1.8
2.6
3.5
5.3
7
11
16
0.47
0.7
1
1.4
2.1
2.8
4.2
5.6
8.4
12
0.47
0.7
1
1.4
2.1
2.7
4.1
5.5
8.2
12