Professional Documents
Culture Documents
Series: 2 Port Solenoid Valve For Dust Collector
Series: 2 Port Solenoid Valve For Dust Collector
Series VXF
2 port solenoid valve for dust collector
Series VXF
VX2
VXZ
VXD
VXP
Valve spring
Pressure action
chamber
VXE
Supply orifice
VXR
VXH
VXF
Armature
VX3
VXA
VCH
Model
2150
VXF
2160
VXFA
2280
Port size
34
1
11 2
Energized
VDW
Since the bleeding lowers the pressure inside
the pressure action chamber, the valve pressing-down force becomes weaker than the valve
pressing-up force and the valve is opened.
Cv
9.5
18
45
VQ
LVM
VCA
VCB
Dedicated
controller
VCL
VCS
Bag filter
VCW
0.01 0.99
O
F
F
SW2
2
0 0 0
OFF
0 0
456
78
901
SW1
ON
SW8
O
F
F
Dust including
air inlet
23
sec
0 299
sec
LED LED
11
12
OUT CAS
LED LED
13
14
IN POW
140
LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8 LED9 LED10
ON
1A
OFF
SV2
SV1
SV4
SV3
SV6
SV5
SV8
SV7
SV10
SV9
COM
AC1 AC2 FG
5
140
4 x 4.5
169
Series VXF
How to Order
Solenoid type
Normally closed
VXF 2150
06
VXFA 2150
06
1 G
Option
Standard
S
With silencer
Refer to the table (2) below for availability.
Nil
Electrical option
Nil
06
10
14
S
L
Rc 3/4
Rc 1
Rc 1 1 2
Rated voltage
1
2
3
4
5
6
7
8
9
None
With surge voltage suppressor
With indicator light
With light/
surge voltage suppressor
Electrical entry
G
Grommet
C
Conduit
D
DIN terminal
T
Conduit terminal
Refer to the table (1) given below for availability.
Caution
Table (1)
Rated Voltage-Electrical Entry-Electrical Option
Insulation type
Class B
Electrical entry
G
C
D, T
S
L, Z
Electrical option
S Note)
1 (100 V)
2 (200 V)
3 (110 V)
AC
4 (220 V)
7 (240 V)
8 (48 V)
5 (24 V)
DC
6 (12 V)
170
Selection
When selecting the air operated type VXFA, select 2 port solenoid
valves (with orifice dia. of 3 or more and effective area of 6 mm2 or
more) in order to maintain the pilot valve performance.
Series VXF
Model/Valve Specifications
Port Orifice
dia.
size (mm)
20
34
27
Solenoid type
40
11 2
Model
Min.
Flow
Max. operating pressure
operating
Ambient
Fluid
characteristics Withstand
differential (MPa)
pressure
pressure temperature temperature
Air
differential Solenoid
Air
(MPa)
(C) Note 1)
(C)
operated
2
(MPa)
valve
valve Effective area (mm )
AC 1.0
VXF2150
VXFA2150
1.0
0.03
170
2.0
10
to 60
DC 0.7
AC 1.0
VXF2160
VXFA2160
0.03
VXF2280
VXFA2280
0.03
1.0
330
2.0
10
to 60
1.0
810
2.0
10
to 60
DC 0.7
AC 1.0
DC 0.7
Mass
(g)
AC 5to 60 VXF
2150 530
VXFA
DC 5to 40 2150 350
VXF
AC 5to 60 2160 580
VXFA
DC 5to 40 2160 400
VXF
AC 5to 60 2280 1500
VXFA
DC 5to 40 2280 1300
Model
VXF
2150
VXF
2160
VXF
2280
Power Frequency
(Hz)
source
AC
DC
AC
DC
AC
DC
50
60
50
60
50
60
VXD
VXZ
VXE
VXP
VXR
Solenoid Specifications
Air operated type
VX2
Apparent
power (VA)
Pilot exhaust
Power
Temperature
Voltage
noise (dB)
consumptions
rise (C)
fluctuation
(W)
(Rated
Without With
(%)
Inrush Holding
(Holding)
voltage)
silencer silencer
45
Rated
20
11
4.5
value
35
104
83
10
55
6
45
Rated
20
11
4.5
value
35
105
85
10
55
6
60
Rated
40
18
7.5
value
50
108
85
10
8
60
VXH
VXF
VX3
VXA
VCH
VDW
VQ
LVM
VCA
VCB
VCL
VCS
VCW
171
Series VXF
Model Selection (In the case of using as a bag filter)
Model selection
The deterrioration of VXF/VXFA properties due to the tube length from data B (response time/idle time) and data C (start-up speed), can be measured.
Refer to this data to set energization time. Use data A (flow rate characteristics) to calculate the flow rate for each loading time separately in relation to the
nozzle dia./qty., pressure, and tube. The data does not correspond to the actual bag filter operation. (In the data: Without tube and Tube length = VXF)
How to calculate
Pilot valve
(I.D. 6, 10)
How to calculate
Provide the pressure from the air resource to the air
tank. Close the stop valve, set the nozzle dia. and
qty., and then energize the solenoid valve as well as
the pilot valve of the air operation valve in accordance
with the prescription. (Change the tube length.)
Stop valve
Energization
time
Electric signal
Air tank inside pressure PA
Ultimate pressure
Air
tank
Nozzle
Amplifier
VXF2150/VXFA2150
Tank 20l
Pressure 0.7 MPa
MP
6 x 6 pcs.
PM: Raised up to 0.41 MPa
MP
6 x 10 pcs.
6 x 10 pcs.
Tube
2,000
mm
66 x 8 pcs.
pcs
6 x 6 pcs.
VXF2160
VXFA2160
Tank 41l
6 x 10 pcs.
Pressure 0.7 MPa
MP
PM: Raised up to 0.43 MPa
MP
VXF2280
VXFA2280
Tank 70l
Pressure
0.7 MPa
10 x 8 pcs.
500 mm
6 x 6 pcs.
Without tube
(VXF2150)
A=0.5 MPa
MP
PA=0.5
6 x 6 pcs.
VXF2150
VXFA2150
6 x 8 pcs.
Start-up time
Idle time T1
Response time T2
Solenoid oscillograph
PM x 0.9
I.D. x qty.
PM: Raised up
to 0.48 MPa
T2 (Response time)
Energization time T (ms)
T1 (Idle time)
VXF2160/VXFA2160
Air tank 70l
A=0.7 MPa
MP
PA=0.7
6 x 10 pcs.
66 x 14 pcs.
pcs
The longer the tube length, the longer the response time and wasted time. If
longer than the length in the diagram, the valve might not open due to the tube
resistance.
6 x 12 pcs.
66 x 12 pcs.
pcs
500 mm
2,000
mm
Without tube
(VXF2160)
6 x 10 pcs.
A=0.5 MPa
MP
PA=0.5
6 x 10 pcs.
VXF2280/VXFA2280
Air tank 70l
A=0.7 MPa
MP
PA=0.7
10 x 12 pcs.
10
10 x 12 pcs.
pcs
10 x 10 pcs.
10
10 x 8 pcs.
pcs
10
10 x 8 pcs.
pcs
10
10 x 10 pcs.
pcs
Without tube
(VXF2280)
VXF(A)2150
Tank 20l
6 x 6 pcs.
VXF(A)2160
Tank 41l
10pcs.
pcs.
6 x 6
VXF(A)2280
Tank 70l
10 x 8 pcs.
100 mm
Tube length L (mm)
500 mm
A=0.5 MPa
MP
PA=0.5
10 x 8 pcs.
Energization time T (ms)
172
6 x 14 pcs.
Series VXF
Construction
Solenoid type
VX2
VXD
VXZ
VXE
VXP
VXR
VXH
VXF
VX3
VXA
Component Parts
No.
1
2
3
4
5
6
Description
Body
Bonnet
Diaphragm assembly
Spring
Hexagonal bolt
Operated valve for dust collector
VCH
Material
Aluminum
Aluminum
NBR, POM
Stainless steel
Stainless steel
VDW
VQ
LVM
VCA
VCB
VCL
VXF 2150 00 1 G
Model Port size
2150
2160
2280
VCS
Electrical option
Rc 3/4
Rc 1
Rc 1 1/2
Nil
S
L
Z
VCW
None
With surge voltage suppressor
With indicator light
With light/surge voltage suppressor
Rated voltage
1
2
3
4
5
6
7
8
9
Electrical entry
G
C
D
T
173
Series VXF
Dimensions
VXF2165 0: Solenoid type
Grommet: G
2xM
2xM
Model
VXF2150
VXF2160
VXF2280
174
M
Port size
Rc
34
1
11 2
40
48
77
25
33.5
48.5
66
74
110
36
45
63
35.5
40
57
32.5
38
49
20
20
23
30
30
35
23
23
25
113
127
162
103
118
152
33
37
28
Conduit: C
Series VXF
Conduit
VXF2150/2160
VXF2280
K
39
39
41
Model
VXF2150
VXF2160
VXF2280
N
96
110
144.5
VX2
VXD
VXZ
VXE
VXP
VXR
VXH
DIN Terminal
DIN terminal: D
VXF2150/2160
VXF2280
Hexagon width across flats 22
Model
VXF2150
VXF2160
VXF2280
K
59
59
60
N
96
110
144.5
Q
45
45
48
Cable 6 to 12
VXF
VX3
VXA
VCH
VDW
VQ
LVM
VCA
VCB
VCL
VCS
Conduit terminal: T
VXF2150/2160
VCW
Conduit Terminal
VXF2280
Model
VXF2150
VXF2160
VXF2280
K
92
92
95
N
96
110
144.5
Q
59
59
62
175
Series VXF
Dimensions
VXFA2150/2160: Air operated type
Exhaust port
2xM
Exhaust port
2xM
Model
VXFA2150
VXFA2160
VXFA2280
176
M
Port size
Rc
34
1
11 2
40
48
77
25
33.5
48.5
66
74
110
36
45
63
35.5
40
57
32.5
38
49
20
20
23
30
30
35
23
23
25
72
86
114
33
37
55
Series VXF
Specifications
Model
Input voltage
Output voltage
ON time
Time setting OFF time
Time accuracy
Number of output points
Operating ambient temperature
Operating ambient humidity
Ouput current
Power supply fuse
VXFC 06 D
Number of
output points
06
10
Voltage
D 24 to 48 VDC
D-6
12 VDC
A 85 to 220 VAC
6
10
VXFC 06
10 A
85 to 220 VAC
VXFC 06
10 D
24 to 48 VDC
Same as input voltage
0.01 to 0.99
0 to 299
2%
6 to 10 points
0 to 50C (No condensation)
45 to 80% (No condensation)
0.3 A or less
0.3 A or less
3A
1A
VXFC 06
10 D-6
12 VDC
VX2
VXD
VXZ
0.3 A or less
1A
VXE
VXP
4 output points
Two-time hitting only for CH2
For
ON for 1 sec.
OFF for 2 sec.
2 sec.
1 sec.
OFF t
CH2
VXA
OFF t
OFF t
1 sec.
VDW
Dimensions
VQ
1 sec.
Power SW OFF (Output stop)
Controller
No.n
(Slave)
Slave
setting
901
Terminal block
for power supply
VCB
0 0 0
SW8
VCA
SW2
1
2
3
4
5
6
7
8
9
0
0 0
SW1
1
2
OFF
O
F
F
ON
0 to 299 sec
VCL
LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8 LED9 LED10
SV2
SV1
SV4
SV3
SV6
SV5
SV8
SV7
SV10
SV9
COM
AC1 AC2 FG
13
9
5
OFF
9.5 9.5
4 x 4.5
5
18.75
9.5
1 cycle
No.1 output
30.5 13
52.5
14
No.2 output
9 9
47
140
No.3 output
VCS
Power switch
ON
1A
45.5
66.5
61
34 or less
26
Start
output
output
output
output
output
10 or less
output
38 or less
No.n output
Operation
LVM
140
Controller
No.3
(Slave)
Slave
setting
ON time setting SW
5
11.5
Cascade Connection
(Multiple-board connection)
78
O
F
F
2 sec.
VCH
tA
tA
2 sec.
1 sec.
1 sec.
2 sec.
1 sec.
Two-time hitting
Controller
No.1
(Master)
Master
setting
VX3
ON t
CH1
CH4
1 sec.
2 sec.
2 sec.
1 sec.
Connection
Stop signal
VXH
VXF
456
2 sec.
CH3
ON time
Power supply
VXR
(VXFC10)
177
VCW
VXF
Specific Product Precaution
Series
Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions,
and pages 17 to 19 for 2 Port Solenoid Valves for Fluid Control Precautions.
Caution
1. The silencer's response properties do not change in the initial
stage, but will change due to the blockage after long use. Replace it after using about 500,000 times. This number is subject
to change based on fluid quality and energization time.
2. When using a silencer, make space for silencer replacement.
Selection
Caution
1. The response performance and start-up speed deterriorate in
case of air operated type (VXFA) as compared with a solenoid
type (VXF) case. Refer to the data for pilot piping.
2. Note that for DC units, idle time and return time increase if the
voltage is lowered. If a surge voltage suppressor is installed,
the return speed decreases.
Warning
1. The controller starts its output the moment the power switch is
turned ON. Be aware that even if the power switch is turned
OFF, power is connected to the terminal board.
Caution
1. Make sure that the voltage of the power to be input matches
the voltage in the controller's specifications. The voltage of the
power that has been input becomes the voltage that is output
to the solenoid valves.
2. Connect a ground that is rated Class 3 or greater to the power
supply terminal board.
3. If the power source is DC, use caution to its polarity. If the polarity is incorrect, it may result in a malfunction or damage.
4. Refer to the separate operation manual for further details.
Environment
Caution
1. Operate under conditions that are free of vibration and impact.
2. Operate in an ambient temperature range between 0C and
50C.
3. Operate in an ambient humidity range between 45% to 85%
(with no condensation). For further details, refer to the instruction manual in which it is explained separately.
178