DCX-B Hardware Manual
DCX-B Hardware Manual
DCX-B Hardware Manual
ED-DCX-B Backbone
Version 6.0
EMC Corporation
Corporate Headquarters:
Hopkinton, MA 01748-9103
1-508-435-1000
www.EMC.com
Contents
Preface
Chapter 1
Overview
ED-DCX-B features ........................................................................... 14
Hardware components..................................................................... 15
Port side of the ED-DCX-B ........................................................ 16
Nonport side of the ED-DCX-B ................................................ 18
Blades.................................................................................................. 19
High availability ............................................................................... 21
Reliability ........................................................................................... 22
Serviceability ..................................................................................... 23
Software features............................................................................... 24
Security............................................................................................... 25
Network manageability ................................................................... 26
Chapter 2
Installation
Time and items required .................................................................. 28
Site preparation, unpacking the ED-DCX-B, and safety ............. 30
Items included with the ED-DCX-B ............................................... 33
Providing power to the ED-DCX-B ................................................ 34
Port numbering ................................................................................. 35
Managing cables................................................................................ 36
Installing ICL cables (optional).................................................36
Chapter 3
Contents
Chapter 4
Chapter 5
45
47
48
49
50
51
52
54
55
65
68
71
73
76
Appendix A
Specifications
Introduction.....................................................................................
System architecture ........................................................................
System size and weight..................................................................
System blade and FRU weights ....................................................
Facility requirements......................................................................
Power specifications.......................................................................
Power cords (Japan, Denan)..........................................................
Power cords .....................................................................................
Environmental requirements ........................................................
Fibre Channel port specifications.................................................
116
117
119
120
121
122
123
124
128
129
Contents
Appendix B
Application Blades
Introduction ..................................................................................... 142
PB-48K-AP4-18 blade...................................................................... 143
PB-48K-18i blade ............................................................................. 144
PB-48K-16IP blade........................................................................... 145
Appendix C
Appendix D
Index
Contents
Preface
Related
documentation
Preface
For the most up-to-date information, always consult the EMC Support
Matrix (ESM), available through E-Lab Interoperability Navigator
(ELN) at: http://elabnavigator.EMC.com, under the PDFs and
Guides tab.
Instructions on how to best use the ELN (tutorial, queries, wizards)
are provided below this Log in window. If you are unfamiliar with
finding information on this site, please read these instructions before
proceeding any further.
Under the PDFs and Guides tab resides a collection of printable
resources for reference or download. All of the matrices, including
the ESM (which does not include most software), are subsets of the
E-Lab Interoperability Navigator database. Included under this tab
are:
Under the PDFs and Guides tab, consult the Internet Protocol pdf
under the "Miscellaneous" heading for EMC's policies and
requirements for the EMC Support Matrix.
Conventions used in
this document
CAUTION
A caution contains information essential to avoid data loss or
damage to the system or equipment.
Preface
IMPORTANT
An important notice contains information essential to operation of
the software.
WARNING
A warning contains information essential to avoid a hazard that can
cause severe personal injury, death, or substantial property damage
if you ignore the warning.
DANGER
A danger notice contains information essential to avoid a hazard
that will cause severe personal injury, death, or substantial property
damage if you ignore the message.
Typographical conventions
EMC uses the following type style conventions in this document:
Normal
Bold
Italic
Preface
ESD precautions
Courier
Used for:
System output, such as an error message or script
URLs, complete paths, filenames, prompts, and syntax when
shown outside of running text
Courier bold
Used for:
Specific user input (such as commands)
Courier italic
<>
[]
{}
...
10
General information
Preface
Your comments
11
Preface
12
1
Overview
Overview
14
15
19
21
22
23
24
25
26
13
Overview
ED-DCX-B features
The ED-DCX-B represents the next generation of advanced Fibre
Channel platforms used to intelligently interconnect storage devices,
hosts, and servers in a Storage Area Network (SAN). The ED-DCX-B
is the highest-performance and highest-scalability enerprise platform
offered by EMC. It satisfies the most demanding Reliability,
Availability, and Serviceability (RAS), performance, and scalability
requirements, while delivering investment protection,
interoperability, and fabric-based intelligence advantages found only
in the Connectrix B product family.
Key features of the platform include:
Support for high-performance port blades running at 1-, 2-, 4-, 8-,
or 10-Gbit/sec, enabling flexible system configuration.
14
Overview
Hardware components
The ED-DCX-B features a modular and scalable mechanical
construction that allows a wide range of flexibility in installation,
fabric design, and maintenance. The chassis may be mounted with
the cables facing the front of the equipment rack or to the rear, and
consists of the following:
15
Overview
Up to 4 power supplies
At 240 VAC: two power supplies are required, regardless of
the number of port or applications blades
At 110 VAC: four power supplies are required when using
the PB-48K-AP4-18, PB-48K-18i, or PB-48K-16IP blades).
Note: Even though the ED-DCX-B can operate at 110-120 VAC, it is not
recommended.
All blades are serviced from the port side of the ED-DCX-B.
Blowers, power supplies, and power cables are serviced from the
nonport side
16
Overview
2
3
4
Figure 1
Exhaust Vent
Hardware components
17
Overview
1
2
Figure 2
18
Power supply
Blower assembly
Overview
Blades
Table 1 summarizes the port, application, control processor, and core
switch blades that are available for the ED-DCX-B.
Table 1
Description
Name
Function
CP8
The CP8 blade contains the control plane for the chassis. There
are two CP8 blades for redundancy. This control processor blade is
compatible only with the Brocade DCX.
CR8
The CR8 blade contains the ASICs for switching between port
blades. Every port blade connects to every core switch blade.
There are 384 total ports for port blades. Each core switch blade
connects to 192 backplane ports. Core switch blades have
additional front port connectivity to connect multiple chassis and
backplane connections for the storage server blade. This core
switch blade is compatible only with the Brocade DCX
PB-DCX-16P
(FC8-16)
PB-DCX-32P
(FC8-32)
PB-DCX-48P
(FC8-48)
PB-48K-10G-6
(FC10-6)
Blades
19
Overview
Table 1
Description
Name
Function
PB-48K-AP4-18
(FA4-18)
PB-48K-18i
(FR4-18i)
PB-48K-16IP
(FC4-16IP)
Note: The blade identifiers inparenthsis in Table 1 reflect the Brocade blade
model names. These are the names that will appear in the various CLI output
and logs.
20
Overview
High availability
The following features contribute to the high-availability design:
High availability
21
Overview
Reliability
The ED-DCX-B uses the following error detection and correction
mechanisms to ensure reliability of data:
22
Each control processor contains one serial port and two Ethernet
ports, for management and for service. Offline control processor
diagnostics and remote diagnostics simplify troubleshooting. The
standby control processor monitors diagnostics to ensure it is
operational, should a failover be necessary.
Overview
Serviceability
The ED-DCX-B provides the following features to enhance and
ensure serviceability:
USB port on control processor blades for all tasks that formerly
required an FTP/SCP server, including software and firmware
upgrades.
RASlog messages
SMI-S compliant
Watchdog timers
Status LEDs
Serviceability
23
Overview
Software features
The Fabric OS allows any Fibre Channel-compliant device to attach to
the switches as long as it conforms to the device login, name service,
and related Fibre Channel standards. Each operating environment
requires that a Fibre Channel host bus adapter (HBA) be available
with a standards-compliant driver for correct interface to the fabric.
Fabric OS consists of a set of embedded applications running on top
of an embedded Linux operating system kernel. These applications
include:
24
Name server
Alias server
Zone server
Syslog auditing
NTP
Overview
Security
Table 2 highlights some of the key security features available for the
ED-DCX-B and for other Connectrix B switches running Fabric OS
5.2.0 or later.
Table 2
Login banner
SNPMv3
FC-SP
Secure RPC
Telnet disable
Default zoning
Telnet timeout
Event auditing
Change tracking
Persistent domain ID
E_Port disable
Security
25
Overview
Network manageability
The ED-DCX-B has a single domain and is managed as a single
element with the Enterprise Fabric Connectivity Manager
(EFCM)/Fabric Manager (FM). The ED-DCX-B responds to its own IP
address and appears as a separate entity to the Telnet protocol and
SNMP.
All management interfaces, such as Telnet, Web Tools, standards
compliant SMI-S, and Management Server, support a port N within
blade M naming scheme.
The ED-DCX-B supports SNMPv1 and SNPMv3. When SNMP
devices send SNMP messages to a management console running
SAN management software, the information is stored in a
management information base (MIB). Fabric OS v6.0.0 supports the
latest Fibre Alliance Fibre Channel Management (FCMGMT) and
Storage Management Initiative (SMI) MIBs, which allow common
information necessary for management software to provide
information to a SAN administrator. Refer to the EMC Connectrix B
Series Fabric OS MIB Reference Guide for additional MIB information.
26
2
Installation
Installation
28
30
33
34
35
36
27
Installation
IMPORTANT
EMC recommnds that the installationof the ED-DCX-B be
performed by trained EMC service personnel. The content in this
chapter is being provided for informational purposes only and is
not intended to be a how to manual for customer set up of the
ED-DCX-B.
You can set up and install the ED-DCX-B in the following ways:
Installation task
Time estimate
Items required
30 minutes
30 minutes
28
Installation
Table 3
Installation task
Time estimate
Items required
20 minutes
30 minutes
60 minutes
10 minutes
20 minutes
29
Installation
30
Installation
5. Ensure that the air intake and exhaust vents have a minimum of 2
in. of airspace.
6. Ensure that the air temperature on the air intake side is less than
40 degrees Celsius (104 degrees Fahrenheit) during operation.
CAUTION
Use safe lifting practices when moving the product.
Note: A fully populated ED-DCX-B (eight PB-DCX-48P port cards, 384 ports)
weighs approximately 104 kg (228 lbs) and requires a hydraulic or assisted
lift to install it.
31
Installation
15. Gently slide the chassis onto the final installation surface,
ensuring that it remains supported during the transfer.
16. Ensure that the chassis is oriented so that the nonport side has
access to intake air (cool).
17. Reinstall the cable management comb.
18. Reinstall the door.
32
Installation
14U rack mount kit with instructions (includes rear brackets and
bottom support rails)
Order the optical transceivers (SFP and XFP) from EMC. The
ED-DCX-B supports SWL, LWL, and ELWL transceivers.
33
Installation
IMPORTANT
To prevent a potential IP address conflict, do not connect the
ED-DCX-B to the network until the IP addresses are configured
(Chapter 3, Log In and Configuration).
Note: To power off the ED-DCX-B, go to Powering off the ED-DCX-B.
34
Installation
Port numbering
The director uses the following port numbering method
(Appendix D, Port Numbering Template).
Slots are numbered 1 through 12, from left to right when facing the
port side of the ED-DCX-B. Control processor blades (CP8) can be
installed only in slots 6 and 7. Core switch blades (CR8) can be
installed only in slots 5 and 8.
Port numbering
35
Installation
Managing cables
The cable management comb (Figure 1) is attached to the chassis
under the chassis door and allows for simple cable management. The
comb can be installed without service disruption.
Route cables down in front of the blades to keep LEDs visible. Leave
at least one meter of slack for each fiber optic cable to provide room
to remove and replace blades.
Note: Do not route the cables in front of the air exhaust vent, which is located
at the top of the port side of the chassis.
Note: The cables can cross between the slot 5 CR8 blade and the slot 8 CR8
blade as long as the top-to-bottom rule is followed.
36
Installation
1
2
3
4
5
6
7
8
Chassis 1
ICL cables
Port blades
Chassis 2
Figure 3
Managing cables
37
Installation
1
2
3
4
5
6
7
8
Figure 4
38
Chassis 1
ICL cables
Port blades
Chassis 2
Installation
1
2
3
4
5
6
7
8
Chassis 1
ICL cables
Port blades
Chassis 2
Figure 5
Managing cables
39
Installation
1
2
3
4
5
6
7
8
Chassis 1
ICL cables
Port blades
Chassis 2
Figure 6
40
3
Log In and
Configuration
Configuration overview....................................................................
Establish a serial connection and log on to ED-DCX-B ................
Configure IP addresses......................................................................
Establish an Ethernet connection.....................................................
Customize a switch name .................................................................
Set the Domain ID..............................................................................
Verify the PID mode and connect to the fabric..............................
Enable software licenses ...................................................................
Back up the configuration.................................................................
42
43
45
47
48
49
50
51
52
41
Configuration overview
The ED-DCX-B must be configured before it is connected to the
fabric, and all of the configuration commands must be entered
through the active CP blade. The configuration includes the
following parameters:
Switch name
Domain ID (optional)
The WWN is initially set by the factory to match the license ID (which
is based on the chassis serial number). The WWN can be changed but
the license ID cannot be modified.
The configuration information is mirrored to the standby CP blade,
which allows the current configuration to remain available even if the
active CP blade fails. The configuration information for the
ED-DCX-B is stored in the WWN cards and the flash memory of the
CP blades. The configuration can be backed up to a workstation
(uploaded) and then downloaded to the active CP blade if necessary.
The basic steps required for the initial configuration are:
1. Establish a serial connection and log on to the ED-DCX-B.
2. Set up IP addresses.
3. Establish an Ethernet connection.
4. Specify a switch name.
5. Specify a domain ID.
6. Verify the PID mode and connect the ED-DCX-B to the fabric.
7. Enable software licenses.
8. Back up the configuration.
42
43
44
Configure IP addresses
The ED-DCX-B requires three IP addresses, which are configured
using the ipAddrSet command. IP addresses are required for both CP
blades (CP0 and CP1) and for the single logical switch (shown as
SWITCH under the ipAddrShow command) in the ED-DCX-B.
Note: The default IP addresses and host names are:
o 10.77.77.75 / CP0 (the CP blade in slot 6 at the time of configuration), and
o 10.77.77.74 / CP1 (the CP blade in slot 7 at the time of configuration)
IMPORTANT
Resetting an IP address while the ED-DCX-B has active IP traffic
such as Fabric Manager, Fabric Watch, SNMP, or other applications
can cause traffic to be interrupted or stopped.
To configure the IP addresses for both CP blades (from the active CP
blade):
1. Login to the active CP as admin using the serial cable connection.
2. Set up the ED-DCX-B IP address by entering the ipaddrset -sw 0
command:
swDir:admin> ipAddrSet -sw 0
Configure IP addresses
45
46
47
48
49
50
51
configShow
ipaddrShow
licenseShow
switchShow
52
4
Monitor System
Components
Introduction ........................................................................................
Port or application blade...................................................................
Control processor blade (CP8) .........................................................
Core switch blade (CR8)....................................................................
Power supply......................................................................................
Blower assembly ................................................................................
WWN bezel (logo plate) and WWN card .......................................
54
55
65
68
71
73
76
53
Introduction
The ED-DCX-B is engineered for reliability and requires no routine
operational steps or maintenance. This chapter provides information
about determining the status of each component using LEDs and CLI
commands. Refer to the EMC Connectrix B Series Fabric OS Web Tools
Administrators Guide and the EMC Connectrix B Series Fabric OS
Administrators Guide for additional information.
54
55
3
4
Power LED
Status LED
Figure 7
56
3
4
Power LED
Status LED
Figure 8
57
!
47
!
47
23
46
22
45
21
44
20
43
19
42
18
41
17
40
16
39
15
38
14
37
35
13
11
36
12
34
10
35
11
34
33
10
33
32
8
32
8
31
7
30
6
29
5
28
4
27
3
26
2
25
1
24
0
Power LED
Status LED
Figure 9
58
Power LED
Status LED
Figure 10
59
GE
3
FC
3
FC
FC4
16IP
Power LED
Status LED
Figure 11
60
15
14
13
12
11
10
9
8
7
6
6
5
4
4
3
2
1
0
GE0
GE1
FR4
18i
Power LED
Status LED
Figure 12
61
15
14
13
12
11
10
9
8
7
6
6
5
4
3
2
1
0
A0
A1
FA4
18
Power LED
Status LED
Figure 13
62
Table 4 describes the port and application blade LED patterns and the
recommended actions for those patterns.
Table 4
LED purpose
Color
Status
Recommended action
Power LED
Steady green
No action required.
Steady amber
Blade is faulty.
Status LED
63
Table 4
64
LED purpose
Color
Status
Recommended action
Port Status
Polling is in progress.
Steady green
No action required.
No action required.
Flickering green
No action required.
Steady amber
Fast-flashing amber
(on 1/2 second, then
off 1/2 second)
Alternating green/amber
Port is bypassed
1. Check the LED indicators on the CP blade (Figure 14). The LED
patterns may temporarily change during POST and other
diagnostic tests. For information about how to interpret the LED
patterns, see Table 5.
2. Check port blade status by typing slotShow and haShow.
Figure 14 identifies the CP8 blade.
65
3
4
5
6
7
8
Status LED
Power LED
USB LED
USB port
Active CP LED
Figure 14
66
LED purpose
Color
Status
Recommended action
Power
Steady green
No action required.
Steady amber
Environmental range
exceeded.
Flickering green/amber
No action required.
Steady green
No action required.
Steady blue
Active CP blade.
No action required.
Standby CP blade.
No action required.
Status
Ethernet Link
Status
Ethernet Link
Speed
Active CP
67
1. Check the LED indicators on the core switch blade (Figure 15).
The LED patterns may temporarily change during POST and
other diagnostic tests; for information about how to interpret the
LED patterns, see Table 5.
2. Check core switch blade status by typing slotShow and haShow.
Figure 15 identifies the core switch blade.
68
LINK ATTN
ICL 1
3
4
LINK ATTN
ICL 0
LINK ATTN
ICL 0
Status LED
ATTN LED
Power LED
ICL connector
LINK LED
Figure 15
69
Table 6 describes the core switch blade LED patterns and the
recommended actions for those patterns.
Table 6
LED purpose
Color
Status
Recommended action
Power
Steady green
No action required.
Steady amber
Environmental range
exceeded.
Steady green
ICL connected
No action required.
No ICL
No action required.
Blinking amber
Attention required
Status
LINK LED
ATTN LED
70
Power supply
To determine the status of a power supply
1. Check the LED indicator on the power supply (Figure 16). The
LED patterns may temporarily change during POST and other
diagnostic tests; for information about how to interpret the LED
patterns, see Table 7.
2. Check power supply status by typing psShow.
The power supply status displays OK, Absent, or Faulty. If a
power supply is absent or faulty, contact the switch supplier to
order replacement parts.
Figure 16 displays the power supply.
1
Power LED
Figure 16
Power supply
Power supply
71
Table 7
72
LED purpose
Color
Status
Recommended action
Power
No light
(LED is off)
Steady green
No action required.
Flashing green
Blower assembly
To determine the status of a blower assembly
Blower assembly
73
1
2
Power LED
Fault LED
Figure 17
74
Blower assembly
Table 8
LED purpose
Color
Status
Recommended action
Power
No light
(LED is off)
Steady green
No action required.
No light
(LED is off)
Steady amber
Slow-flashing amber
(on 2 sec, then off 2 sec)
Flashing amber
(on 1/2 sec, then off 3.5 sec)
Fan is disabled.
Fast-flashing amber
(on 1/2 sec, then off 1/2 sec)
Environmental range
exceeded.
Fault
Blower assembly
75
76
Type of message
1
2
3
4
1
Slot numbers
Figure 18
LED purpose
Color
Status
Recommended action
Steady green
Power is OK.
No action required.
Steady amber
Blade is faulty.
Check blade.
Blade is OK.
No action required.
Note: If a blade slot or power supply bay has a filler panel installed, the corresponding LEDs on the WWN blade do not light
up.
77
78
5
Removal and
Replacement
Procedures (RRPs)
79
Introduction
Repair and replacement of faulty parts on the ED-DCX-B should be
performed by a trained EMC Support representative.
IMPORTANT
Customer servicing of the ED-DCX-B could result in the voiding of
the warranty or service agreement.
The information in this section is provided for information
purposes only and is not intended to be a how to guide for
customer performed maintenance. Not all of the FRUs described in
this chapter are available from EMC. Consult your EMC Support
representative for information concerning which comonents are
replaceable in the field.
Note: Read the safety notices before servicing (Conventions used in this
document).
80
Figure 19
Support the door to prevent it from falling. Pull and remove the
door.
81
1. Align the holes in the door with the pins in the chassis.
2. Push the door into place.
82
83
Figure 20
84
Slots are numbered from 1 through 12, from left to right when facing
the port side of the ED-DCX-B. Port and application blades can be
installed in slots 1 through 4 and 9 through 12.
Time and items required
The replacement procedure for each port or application blade takes
less than 10 minutes. The following items are required for the blade
and filler panel replacement:
Workstation computer
Phillips screwdriver
Removing a blade
Note: Follow ESD precautions (ESD precautions).
85
86
12. If the blade is not being replaced by another blade, install a filler
panel (RRP: Port and application blade filler panel).
Figure 21
87
Replacing a blade
Note: Follow ESD precautions (ESD precautions).
1. Orient the blade so that the ports are at the front of the chassis
and the flat side of the blade is on the left.
2. (PB-DCX-16P, PB-DCX-32P, and PB-DCX-48P port blades): Adjust
the ejectors to the open position, align the flat side of the blade
inside the upper and lower rail guides in the slot, and slide the
blade into the slot until it is firmly seated.
(PB-48K-10G-6 port blade, and PB-48K-AP4-18, PB-48K-16IP, and
PB-48K-18i application blades) Open the ejectors to approximately
45 degrees, align the flat side of the port blade inside the upper
and lower rail guides in the slot, and slide the port blade into the
slot, with slight pressure to the left, until it is firmly seated.
3. (PB-DCX8-16P, PB-DCX-32P, and PB-DCX-48P port blades): Adjust
the ejectors to the closed position by pulling them away from the
center of the blade.
(PB-48K-10G-6 port blade, and PB-48K-AP4-18, PB-48K-16IP, and
PB-48K-18i application blades) Close the ejectors by pushing the
handles toward the center of the port blade until the ejectors lock.
The levering action of the handles seats the port blade in the slot.
4. (PB-DCX-16P, PB-DCX-32P, and PB-DCX-48P port blades): Adjust
the ejectors to the closed position by pulling them away from the
center of the port blade.
(PB-48K-10G-6 port blade, and PB-48K-AP4-18, PB-48K-16IP, and
PB-48K-18i application blades) Tighten the thumb screw inside each
handle using the Phillips screwdriver.
5. (PB-48K-10G-6 port blade, and PB-48K-AP4-18, PB-48K-16IP, and
PB-48K-18i application blades) Turn the port blade on by sliding the
slider switch in the top ejector up, covering the thumb screw.
6. Verify that the power LED on the port blade is displaying a
steady green light. If it does not turn on, ensure that the port
blade is firmly seated.
7. Install the SFP or XFP (PB-48K-10G-6 only) transceivers and
cables in the port blade.
88
89
90
Figure 22
91
Workstation computer
Serial cable
Phillips #2 screwdriver
The status LED on the CP blade is lit amber, or the power LED is
not lit.
92
3. Enter all remaining commands from the serial console for the
active CP blade, unless otherwise indicated. For more information
about commands, refer to the EMC Connectrix B Series Fabric OS
Command Reference Guide
4. If the functioning CP blade is performing as the active CP blade,
go to step 5 . If the faulty CP blade is performing as the active CP
blade, failover the blades:
a. Login to the faulty CP blade as admin, using either a Telnet or
a serial console connection.
If you connect successfully to the faulty CP, continue to step b.
If you cannot connect to the faulty CP, remove the faulty CP
blade for repair as follows:
Turn the CP blade off and notify the ED-DCX-B of a hot
swap request by sliding the slider switch in the top ejector
down to the off position (Figure 23).
93
94
95
Figure 23
96
3. Tighten the thumb screw inside each handle using the Phillips
screwdriver.
4. Turn the CP blade on by sliding the ON/OFF switch in the top
handle up, to cover the thumb screw.
5. Verify that the power LED is green. If not, ensure that the CP
blade has power and is firmly seated and that the ejectors are in
the locked position.
6. Connect the cables to the new CP blade.
7. Verify the installation (Verifying operation of the new CP
blade).
8. Replace the chassis door (RRP: Chassis door).
Verifying operation of the new CP blade
To verify that boot and POST are complete on the new CP blade and
that the CP blade has achieved failover redundancy:
1. Log into the active CP as admin.
2. Enable the redundancy feature using the haEnable command.
3. Verify HA is enabled using the haShow command. The command
output includes HA Enabled Heartbeat Up and HA-state in
sync.
If not, POST is not complete or the CP blades have not achieved
redundancy. Wait one or two minutes and re-enter the command
until you can verify that redundancy has been achieved.
4. Type slotShow. The command output shows the new CP blade as
enabled:
swDir:admin> slotShow
Slot
Blade Type
ID
Status
--------------------------------1
2
3
4
5
6
7
8
9
10
SW
SW
SW
SW
CR
CP
CP
CR
SW
SW
BLADE
BLADE
BLADE
BLADE
BLADE
BLADE
BLADE
BLADE
BLADE
BLADE
16
16
16
16
17
18
18
17
16
16
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
97
11
12
SW BLADE
SW BLADE
16
16
ENABLED
ENABLED
swDir:admin>
98
readline
##################################################
terminfo
##################################################
termcap
##################################################
setup
##################################################
<output truncated>
tz
##################################################
mtracer-tool
##################################################
lkcd
##################################################
sysstat
##################################################
Removing unneeded files, please wait ...
Finished removing unneeded files.
All packages have been downloaded successfully.
Firmwaredownload has completed successfully.
2007/07/03-15:05:56, [SULB-1002], 924,, INFO, Brocade
DCX, Firmwaredownload command has completed successfully.
99
Phillips #2 screwdriver
The status LED on the core switch blade is lit amber, or the power
LED is not lit.
The slotShow command does not show that the core switch blade
is enabled.
100
101
Figure 24
102
3. Tighten the thumb screw inside each handle using the Phillips
screwdriver.
4. Turn the core switch blade on by sliding the ON/OFF switch in
the top handle up, to cover the thumb screw.
5. Verify that the power LED is green (might require a few seconds).
If not, ensure that the core switch blade has power and is firmly
seated and that the ejectors are in the locked position.
6. Connect to the new core switch blade.
7. Pack the faulty core switch blade in the packaging provided with
the new core switch blade, and contact the switch supplier to
determine the return procedure.
8. Replace the chassis door (RRP: Chassis door).
103
104
Figure 25
105
Phillips #2 screwdriver
106
Figure 26
1. Orient the blower assembly and slide it into the chassis, pushing
firmly to ensure that it is seated.
2. Verify that the power LED displays a green light.
3. Use the screwdriver or your fingers to tighten the captive screws.
107
Status LEDs on the WWN bezel not reflecting the actual status of
the components
108
Table 11
LED location/purpose
Color
Status
Recommended action
Steady green
Power is okay.
No action required.
Steady amber
Card is faulty.
Check card.
Card is okay.
No action required.
Note: If a blade slot has a filler panel installed, the corresponding LEDs on the WWN card do not light up.
Note: If a status LED on the WWN bezel flashes, the power LED on the WWN bezel also flashes, for increased visibility.
Table 12
Data
Related commands
WWN values
wwn, chassisShow
chassisShow
ipAddrShow, ipAddrSet
historyShow, historyLastShow
Name of switch
switchName
109
Table 13
Type of message
110
5. Wait until all the LEDs on the WWN bezel turn off.
6. Remove the four screws from the WWN bezel (Figure 27 on
page 112). Pull the bezel away from chassis and set it aside. The
WWN cards are visible.
7. Remove a WWN card as follows:
To remove a WWN card that has handles: Use the handles to
remove the card.
To remove a WWN card that does not have handles: Use a
Phillips screwdriver to unscrew the two screws which secure
the WWN card to the chassis. Hold the card by the edges and
remove it.
8. Set the WWN card on a static-free surface, such as a grounding
pad.
111
Figure 27
1. Unpack the new WWN card and save the packaging for the faulty
WWN card.
2. Install the WWN card as follows:
To install a WWN card that has handles: Hold the card by the
handles and orient with the LEDs at the bottom. Align the
connector on the card with the connector on the chassis (the
connectors are keyed to ensure correct installation) and use
the push pad to press the card onto the connector until it is
seated.
112
To install a WWN card that does not have handles: Hold the
card by the edges and press the card onto the connector until it
is fully seated. Use the Phillips screwdriver and the two
screws to attach the WWN card to the chassis.
3. Install the WWN bezel. Orient the bezel on the chassis (Figure 27).
Insert and tighten the four screws.
Note: If a serial console session is active, several removal detected and
insertion detected messages display on the console because of the
replacement.
6. Pack the faulty WWN card in the packaging provided with the
new card and return it to the switch supplier.
113
Figure 28
114
A
Specifications
Introduction ......................................................................................
System architecture..........................................................................
System size and weight ...................................................................
System blade and FRU weights .....................................................
Facility requirements .......................................................................
Power specifications ........................................................................
Power cords (Japan, Denan) ...........................................................
Environmental requirements..........................................................
Fibre Channel port specifications ..................................................
Data transmission ranges................................................................
General specifications......................................................................
Regulatory compliance....................................................................
Environmental regulation compliance..........................................
Specifications
116
117
119
120
121
122
123
128
129
130
131
132
137
115
Specifications
Introduction
This appendix provides product specifications and compliances for
the ED-DCX-B.
116
Specifications
System architecture
Table 14
System architecture (1 of 2)
Control Processor
Scalability
Performance
ISL Trunking
Aggregate bandwidth
Switch latency
PB-DCX-16P blade:
<2.1 sec any port to any port at 8 Gbit/sec, cut-through routing.
For the PB-DCX-32P blade:
<2.1 sec any port to any port at 8 Gbit/sec, cut-through routing.
For the PB-DCX-48P blade:
<2.1 sec any port to any port at 8 Gbit/sec, cut-through routing.
For the PB-48K-AP4-18 blade:
<3.6 sec any port to any port at 4 Gbit/sec, cut-through routing.
For the PB-48K-18i blade:
<3.6 sec any port to any port at 4 Gbit/sec, cut-through routing.
For the PB-48K-16IP blade:
<3.6 sec any port to any port at 4 Gbit/sec, cut-through routing.
2112-byte payload
Frame buffers
Classes of service
System architecture
117
Specifications
Table 14
Port types
System architecture (2 of 2)
The PB-DCX-16P and PB-DCX-32P supports these port types:
FL_Port, F_Port, E_Port, and M_Port
PB-DCX-48P supports these port types:
E_Port, F_Port, and M_Port
PB-48K-10G-6 supports this port type:
E_Port and M_Port
PB-48K-AP4-18 supports these port types:
FL_Port, F_Port, E_Port, and M_Port
PB-48K-18i supports these port types:
FL_Port, F_Port, E_Ports, M_Port, VE_Port, EX_Port, and VEX_Port
PB-48K-16IP supports these port types:
FL_Port, F_Port, E_Port, and M_Port
Note: Self-discovery is based on switch type (U_Port) with an optional port type control.
118
Media types
Hot-pluggable, industry-standard small form factor pluggable (SFP) or extended form factor
pluggable (XFP, PB-48K-10G-6 only), LC connector;
- short-wave laser (SWL), up to 500 m (1,640 ft.);
- long-wave laser (LWL), up to 10 km (6.2 mi);
- extended long-wave laser (ELWL), up to 80 km (49.6 mi); distance depends on fiber optic
cable and port speed
Copper 1GbE connections on the PB-48K-16IP blade
Fabric services
Simple Name Server; Registered State Change Notification (RSN); EMC Advanced Zoning;
Web Tools; Fabric Watch; Extended Fabrics; ISL Trunking; End-to-End Performance
Monitoring, FICON CUP, ACL (Access Control Lists), Admin Domains, Reliable Commit
Service, NTP, Syslog, RASlog, auditing
Specifications
Width
Height
Depth
Director:
384-port configuration with eight PB-DCX-48P port
blades
Empty chassis:
No blades
No CPs
No CRs
No power supplies
No fan assemblies
119
Specifications
120
Weight
CP blade (CP8)
CR blade (CR8)
Power supply
Blower assembly
WWN bezel
WWN bezel
Chassis door
Specifications
Facility requirements
The facility where the ED-DCX-B in use must meet the following
requirements to provide for correct operation:
An air flow of at least 350 cubic feet per minute (595 cubic meters
per hour) in the immediate vicinity of the ED-DCX-B
Facility requirements
121
Specifications
Power specifications
The power subsystem is a redundant +48V DC power distribution
system with a provision for up to four 1000-watt, 48V DC bulk power
supplies. Four bulk power supplies produce the intermediate
distribution voltage in the distributed power system.
The power specifications in Table 17 are calculated for fully loaded
systems with four power supplies. A fully loaded system has eight
PB-DCX-48P port blades, two CP8 blades, two CR8 blades, and three
blower assemblies.
Table 17
122
Power specifications
Specification
Value
Input voltage
Nominal: 200 to 240 VAC, single phase, or 110 to 120 VAC, single phase
47-63 Hz
AC inrush current
Ride through
The supply outputs remain within specified regulation for a minimum of 20 msec
after the AC mains are disconnected.
The power supply self-protects from any input voltage, static or dynamic, from zero
volts to its operating ranges. It recovers to normal operation upon returning to its
operating range.
Specifications
Note: Never use the power cord packed with your equipment for other
products.
123
Specifications
Power cords
The types of power cords provided with the ED-DCX-B are specific to
the country where it is installed. For each of these types of power
cords (Table 18), the end that connects to the chassis has an IEC
60320/C19 cable connector. The two AC power receptacles on each
ED-DCX-B chassis are equipped with IEC 60320/C20 power
connectors.
To order a power cord, contact your EMC account representative.
Table 18
CEE-7/7
Schuko
Continental
Europe/Ireland
AS 3112
Australia/New
Zealand
IEC-60309
32A-6h, 230 V~
Country
Argentina
Australia
Austria
Bahrain
Belgium
124
Brazil
Chile
China, Peoples
Rep.
Czech, Rep. of
Denmark
Specifications
Table 18
CEE-7/7
Schuko
Continental
Europe/Ireland
AS 3112
Australia/New
Zealand
IEC-60309
32A-6h, 230 V~
Country
Egypt
England
Finland
France
Germany
Greece
Hong Kong
Hungary
India
Indonesia
Ireland, North
Ireland, South
Israel
Italy
Japan
Korea, South
Malaysia
Mexico
Power cords
125
Specifications
Table 18
CEE-7/7
Schuko
Continental
Europe/Ireland
AS 3112
Australia/New
Zealand
IEC-60309
32A-6h, 230 V~
Country
Monaco
Netherlands
New Zealand
Norway
Poland
Portugal
Puerto Rico
X
X
Russia
Saudi Arabia
Scotland
Singapore
South Africa
Spain
Sweden
Switzerland
Taiwan
X
X
Turkey
126
Specifications
Table 18
CEE-7/7
Schuko
Continental
Europe/Ireland
AS 3112
Australia/New
Zealand
IEC-60309
32A-6h, 230 V~
Country
United Arab
Emirate
United Kingdom /
Ireland
United States
Venezuela
Yugoslavia
Power cords
127
Specifications
Environmental requirements
Table 19 lists the environmental operating ranges for the ED-DCX-B.
The requirements for non-operating conditions are also provided for
acceptable storage and transportation environments.
Table 19
Environmental requirements
Condition
Ambient temperature
10 to 40 C outside switch
(50 to 104 F)
Humidity
Altitude
Up to 3 km (10,000 ft.)
above sea level
0 to 12 km (40,000 ft.)
above sea level
Shock
Vibration
Air flow
350 cu ft/min.
(0.00059 cu m/hr)
None required.
Heat dissipation
Not applicable.
128
Specifications
129
Specifications
Cable type
Single Mode
Multi Mode
9 microns
50 microns
62.5 microns
130
Speed
Minimum distance
Maximum distance
2 Gbit/sec
2m
10,000 m
4 Gbit/sec
2m
10,000 m
8 Gbit/sec
2m
1, 000 m
2 Gbit/sec
0.5 m
300 m (OM2)
500 m (OM3)
4 Gbit/sec
0.5 m
150 m (OM2)
380 m (OM3)
8 Gbit/sec
0.5 m
50 m (OM2)
150 m (OM3)
2 Gbit/sec
0.5 m
150 m
4 Gbit/sec
0.5 m
70 m
8 Gbit/sec
0.5 m
21 m
Specifications
General specifications
The ED-DCX-B is compliant with United States and International
safety and EMC (Electromagnetic Compatibility) standards. Table 21
lists the general specifications for the ED-DCX-B.
Table 21
General specifications
Specification
Description
System architecture
System processor
Modes of operation
Fabric initialization
Routing capacity
A minimum aggregate routing capacity of four million frames per second (for Class 2,
Class 3, and Class F frames in a 64-port switch)
General specifications
131
Specifications
Regulatory compliance
This section describes the regulatory compliance requirements for the
Product Name. It contains:
132
Specifications
Regulatory compliance
133
Specifications
CE statement
134
Specifications
Canadian requirements
This Class A digital apparatus meets all requirements of the
Canadian Interference-Causing Equipment Regulations, ICES-003
Class A.
Laser compliance
Regulatory compliance
135
Specifications
Table 22
Country
Standards
Safety
EMC
Safety
EMC
United States
ANSI C63.4
cCSAus
Canada
ICES-003 Class A
cCSAus
Japan
European Union
EN55022 or CISPR22 or
AS/NZS CISPR22
Argentina
IEC60950-1 or latest
Russia
IEC60950-1 or latest
Korea
136
CE marking
C-Tick mark
S mark
51318.22-99 and
51318.24.99 or latest
GOST mark
GOST mark
MIC mark Class A
GB4943-2001 and
GB9254-1998 or latest
GB17625.1-2003 or latest
CCC logo
CCC logo
BSMI mark
BSMI mark
Specifications
China RoHS
The contents included in this section are per the requirements of the
People's Republic of China- Management Methods for Controlling
Pollution by Electronic Information products.
RoHS
(EPUP)
EPUP
FRU
Brocade
Brocade
CD
Br
ocade
EPUP
TS/HS Dual Language Sheet
In accordance with China's Management Measures on the Control of
Pollution caused by Electronic Information products (Decree No. 39
by the Ministry of Information Industry), the following information is
137
Specifications
Hazardous/Toxic Substance/Elements
Lead (PB)
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(CR6+)
Polybrominated
Biphenyl (PBB)
Polybrominated
Diphenyl Ether
(PBDE)
Fan, Blower
assemblies
PCBA cards
Sheet Metal
Chassis Assembly
Mechanical brackets
and Slides
Slot Filler
Cable management
comb
Cable Comb
Replacement Doors
Software/
Documentation CDs
Name of the
Component
Specifications
CHINA ROHS/(HS/TS)
<<>>
(39)(HS)
SFP
/
X
O
/
Cd C
R6+
PBB
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Pb
X
X
X
X
X
Hg
O
O
O
O
O
PB
DE
O
O
O
O
O
X
X
X
X
X
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
O
O
O
O
O
O
O
O
O
O
O
/SJ/T11363-2006
139
Specifications
140
B
Application Blades
Introduction ......................................................................................
PB-48K-AP4-18 blade ......................................................................
PB-48K-18i blade ..............................................................................
PB-48K-16IP blade............................................................................
Application Blades
142
143
144
145
141
Application Blades
Introduction
This appendix provide details about the application blades that are
optionally available for the ED-DCX-B. Contact your EMC account
representative for additional information.
142
Application Blades
PB-48K-AP4-18 blade
The PB-48K-AP4-18 blade has 16 physical Fibre Channel SFP ports
supporting the Fibre Channel Application Services, and 2 physical
Gigabit 10/100/1000 BaseT Ethernet copper ports supporting blade
management.
The PB-48K-AP4-18 blade is intended as a platform for Fibre Channel
Application Services and blade management. Refer to the EMC
Connectrix B Series Fabric OS Administrators Guide for information on
configuring these features.
PB-48K-AP4-18 blade
143
Application Blades
PB-48K-18i blade
The PB-48K-18i blade has 16 physical Fibre Channel SFP ports
supporting the Fibre Channel Routing Services, and 2 physical
Gigabit Ethernet (GbE) SFP ports supporting the Fibre Channel Over
IP (FCIP) feature. It operates with the EMC Fabric Operating System
and can communicate with another PB-48K-18i or an MP-7500B for
both Fibre Channel Routing services and FCIP, or an AP7420B for
Fibre Channel Routing Services.
The PB-48K-18i blade is intended as a platform for Fibre Channel
Routing Services and FCIP. Refer to the EMC Connectrix B Series Fabric
OS Administrators Guide for information on configuring these
features.
The PB-48K-18i blade provides the following features:
144
Application Blades
PB-48K-16IP blade
The PB-48K-16IP blade enables bridging of iSCSI hosts to Fibre
Channel Fabrics. It has eight Fibre Channel optical SFP ports and
eight Gigabit Ethernet (GbE) copper RJ 45 ports.
Note: The number of initiators per port, blade, or chassis, depends on the
version of Fabric OS and is subject to change from release to release.
Eight Fibre Channel SFP ports supporting link speeds of 1-, 2-, or
4-Gbit/sec.
PB-48K-16IP blade
145
Application Blades
146
C
Diagnostics and
Troubleshooting
Introduction ......................................................................................
Obtaining chassis and component status .....................................
Interpreting POST and boot results...............................................
Diagnostics........................................................................................
Troubleshooting................................................................................
148
149
150
152
153
147
Introduction
For information about troubleshooting the entire fabric, refer to the
EMC Connectrix B Series Fabric OS Administrators Guide.
The ED-DCX-B includes a number of diagnostic aids to assist with
troubleshooting, including LEDs on the hardware, commands that
display current status, diagnostic tests for hardware and software,
and error messages. In addition, a number of managing and
monitoring features are available, such as Web Tools, Fabric Watch,
and Advanced Performance Monitoring.
If the ED-DCX-B does not operate as expected, the following steps
can be taken to diagnose the problem:
Check the LEDs and see the LED tables (Chapter 4, Monitor
System Components) for interpretation and recommended
actions.
Review the error logs. (Refer to the EMC Connectrix B Series Fabric
OS Message Reference Guide and the EMC Connectrix B Series Fabric
OS Administrators Guide for more information).
If the problem is still unresolved after these steps, contact your EMC
Customer Service representative.
148
Command
Information displayed
sensorShow
tempShow
psShow
fanShow
chassisShow
Serial number, time awake, and additional information about each component
slotShow
Slot occupancy
errShow
errDump
System error log. refer to the EMC Connectrix B Series Fabric OS Message Reference Guide for more
information on the messages in this log.
149
POST
Verify that all LEDs return to a normal state after POST completes
(Chapter 4, Monitor System Components).
Any errors detected during POST are written to the system log,
which is accessible through the errShow command. For
information about error messages, refer to the EMC Connectrix B
Series Fabric OS Message Reference Guide.
150
Boot
151
Diagnostics
Diagnostic tests are automatically run during POST to check the
status of the ED-DCX-B. Any error messages generated during POST
are sent to the error logs and to the serial console, if connected.
Diagnostic tests can also be run manually to test and troubleshoot the
hardware and the firmware, including internal connections and
circuitry, transceivers, and port cables. However, diagnostic tests are
generally intended for use by support personnel.
Note: Error messages do not necessarily indicate that the ED-DCX-B requires
maintenance.
152
Troubleshooting
Table 25 provides a list of issues, possible causes, and recommended
actions.
Table 25
Issue
Possible cause
Recommended action
Remove the cable and inspect the pins on the cable and
in the serial port. Do not reinstall if the pins on either
component have any visible damage, as this could
damage the pins on the other component. Replace
components as required.
Configuration data is
inaccurate or cannot be
accessed.
Troubleshooting
153
Table 25
Issue
Possible cause
Recommended action
Chassis is overheated.
154
Table 25
Issue
Possible cause
Recommended action
Troubleshooting
155
156
D
Port Numbering
Template
157
Introduction
Print or copy the templates on the following pages and use them to
document the port numbering pattern for the Brocade DCX. These
templates show:
158
Port side populated with eight PB-DCX-48P port blades, two CR8
blades, and two CP8 blades;
Port side populated with eight PB-DCX-32P port blades, two CR8
blades, and two CP8 blades;
Port side populated with eight PB-DCX-16P port blades, two CR8
blades, and two CP8 blades;
Introduction
159
160
Introduction
161
FC
10-6
162
FC
10-6
56-0000590-01 Rev A
56-0000590-01 Rev A
GE
GE
GE
GE
FC
FC
FC4
16IP
56-0000590-01 Rev A
56-0000590-01 Rev A
FC
FC
FC4
16IP
FC4
16IP
FC4
16IP
Introduction
163
56-0000590-01 Rev A
15
15
14
14
13
13
12
12
11
11
10
10
GE1
GE1
GE0
GE0
FR4
18i
164
56-0000590-01 Rev A
FR4
18i
56-0000590-01 Rev A
FA4
18
56-0000590-01 Rev A
15
15
14
14
13
13
12
12
11
11
10
10
A0
A0
A1
A1
FA4
18
Introduction
165
166
Index
B
back up configuration 52
bandwidth, aggregate 117
bezel, WWN, replacing 108
blade
CP, LEDs 67
CP, status 65
CR, LEDs 70
CR, status 68
PB-48K-16IP 145
PB-48K-18i 144
PB-48K-AP 143
port, LEDs 63
port, replacing 85
port, status 55
blades
support for 14
weight 120
blower assembly
LEDs 75
replacing 106
status 73
boot results, interpreting 150
bridging, iSCSI to Fiber Channel 145
Brocade DCX Data Center Backbone Director
See director
BSMI statement (Chinese) 134
C
cable management comb, replacing 83
cables, ICL 36
cables, managing 36
Canadian requirement 135
CE statement 134
certifications 131, 132, 135
chassis door, replacing 81
China RoHS 137
classes of service 117
commands, WWN card status 109
compliance, environmental regulation 137
configuration, director 42
control processor blade
See CP blade
core switch blade
See CR blade
CP blade 117
replacing 92
status 65
troubleshooting 154
CR blade
replacing 100
status 68
D
data traffic types 118
data transmission, ranges 130
diagnostics
boot results 150
POST 150
167
Index
director
certifications 131, 132, 135
configuration 42
environmental requirement 128
features 14
hardware components 15
high availability 21
installation tasks 28
IP address 45
power requirement 122
rack space requirement 30
reliability 22
serviceability 23
size 119
software features 24
specifications, general 131
troubleshooting 153
weight 119
domain ID, setting 49
door
removing 31
blower assembly 73
LEDs 75
replacing 106
cable management comb
replacing 83
chassis door
replacing 81
CP blade
LEDs 67
replacing 92
CR blade
LEDs 70
replacing 100
ESD precautions 10
filler panel
replacing 90
port blade
LEDs 63
replacing 85
power supply 71
LEDs 71
replacing 104
removing and replacing 80
SFPs, removing 114
troubleshooting 155
weights 120
WWN bezel
LEDs 108
replacing 108
WWN card
LEDs 108
replacing 108
XFPs, removing 114
E
environmental regulation compliance 137
environmental, requirement 128
error messages, WWN card 76
ESD, precautions 10
Ethernet, establish connection 47
F
fabric services 118
fabric, connecting to 50
facility, requirement 121
FCC warning (US only) 132
FCIP 143, 144
Fibre Channel
Application Services 143
classes of service 131
port specifications 129
Routing Services 144
field-replaceable units
See FRUs
filler panel, replacing 90
frame size, maximum 117
FRUs
blades, weights 120
168
H
humidity, requirement 128
I
installation tasks 28
inter-chassis linking (ICL) 36, 118
IP address, configuring 45
iSCSI to Fibre Channel, bridging 145
ISL trunking 117
Index
ESD 10
procedure
reinstalling door 32
removing door 31
unpacking the ED-12000B 31
protocol, ANSI 131
M
manageability, network 26
media types 118
MIC statement (Republic of Korea) 132
N
numbering, port 35
P
PB-48K-16IP blade 145
PB-48K-18i blade 144
PB-48K-AP blade 143
port
Fibre Channel 117
numbering 35
numbering template 158
specifications 129
types 118
port blade, replacing 85
POST, interpreting 150
power cord
specifications 123
types 124
power supply
LEDs 71
replacing 104
status 71
power, providing 34
power, requirement 122
precautions
S
safety guidelines 30
security 25
serial connection, establishing 43
serviceability, features 23
SFPs
extraction tool 114
removing 114
supported types 33
shock, requirement 128
site planning 30
size, director 119
software, features 24
specifications
Fibre Channel port 129
power cord 123
status, port blade 55
EMC Connectrix B Series ED-DCX-B Hardware Reference Manual
169
Index
T
tasks, installation 28
template, port numbering 158
terminal emulator, configuring 43
tool, extraction, SFP 114
tool, extraction, XFP 114
troubleshooting 153
chassis power 153
configuration data 153
CP blade 154
Domain IDs 153
Ethernet link speed 153
FRUs 155
general 148
IP addresses 153
LEDs 154
serial connections 153
V
VCCI statement 133
vibration, requirement 128
W
weight, director 119
WWN bezel
LEDs 108
replacing 108
WWN card
error messages 76
LEDs 108
replacing 108
status 76, 109
verifying need to replace 108
X
XFPs
extraction tool 114
removing 114
supported types 33