Hi Pulse
80kVA
120kVA
160kVA
200kVA
900
840
1900
750
1250
840
1900
1000
1250
840
1900
1200
1250
840
1900
1350
1 Hz
0.1 Hz
100%
100%
120 1 el
2%
CEI EN 50091-1-1/ EN 50091-2 / ENV 50091-3
CE mark
BS EN ISO 9001:1994
L I E B E R T C O R P O R AT I O N
LIEBERT EUROPE
VIA G. ROSSINI 6
20098 S. GIULIANO MILANESE
MILANO
TEL: +39 02 982501
FAX: +39 02 9844633
FM 00722
Printed in Italy
http://www.liebert.com
LIEBERT UK
GLOBE PARK
MARLOW
BUCKINGHAMSHIRE SL7 1YG
UNITED KINGDOM
TEL: +44 (0) 1628 403200
FAX: +44 (0) 1628 403294
POWER PROTECTION
Liebert
80-200 kVA
HIPULSE
UPS SYSTEM:
THE BEST PROTECTION
FOR YOUR CRITICAL LOAD
High reliability IGBT inverter
Available with 6 or 12 pulse rectifier
Paralleling of up to six units using
either modular or centralised static
bypass switch
High efficiency EcoMode
Advanced battery management
Backfeed protection
Battery ground fault warning
Frequency converter 50/60Hz with or
without battery
SNMP network compatible with
dynamic monitoring
BMS connectivity through either
Modbus, JBus or PROFIBUS
Many other optional features to suit
your power needs
NE
W
I E B E R T
O R P O R A T I O N
POWER PROTECTION
OUTAGES
Typically described as a 'zero-volt condition lasting
longer than a half-cycle', outages can be caused by mains
equipment failure, accidents, lightning, operation of
protective devices, etc. The result: system crashes and
hardware failure.
SPIKES/TRANSIENTS
Spikes are a brief intense surge, less than half a cycle in
duration, but with voltages 100% or more above normal.
Transients cause data corruption, processing errors,
incorrect data transfer, keyboard/ mouse/ monitor lockups and hardware damage.
WAVEFORM DISTORTION
FREQUENCY VARIATIONS
Rare in mains power, frequency variations are most
common with back-up power systems such as standby
generators. Off-Line and Line-Interactive models, even
some On-Line UPS, cannot handle frequency problems,
which can cause system crashes and equipment
damage.
SAGS
These short term, low voltage brownouts are triggered
by the startup of large loads, mains switching etc. In
addition to causing system crashes, sags can damage
hardware.
SURGES/SWELLS
With voltages above 110% of normal, surges can be
triggered by rapid reduction in power requirements, due
to large loads being turned off, or by mains switching.
The result: hardware damage.
I E B E R T
O R P O R A T I O N
I E B E R T
O R P O R A T I O N
POWER PROTECTION
IGBT Inverter
Small footprint
Battery management
maintenance requirements.
Maintenance bypass
Allows routine servicing without interrupting
power to the load, providing safe transfer to and
from the UPS system.
I E B E R T
O R P O R A T I O N
ALWAYS IN CONTROL
HIPULSE
MICROPROCESSOR CONTROL
Hipulse UPS System
RS 232
EcoMode.
RS 232
COMMUNICATIONS
Hipulse features highly advanced communications
with the ability to interface with Ethernet/SNMP for
monitoring in networked environments as well as
providing for facility wide monitoring through BMS
Remote
Service Centre
I E B E R T
O R P O R A T I O N
POWER PROTECTION
~~
~~=
UPS 2
~~
~~=
UPS 1
~=
UPS N
~=
~=
~~
~~=
Load
~=
~~
~=
connection
UPS 1
UPS 2
UPS N
Bypass
Supply
~= ~=
~~
~~ ~~
~= ~=
Load
Parallel with Central Static Switch
I E B E R T
O R P O R A T I O N