General
ABB
5
IT
AC drives
Products
ACS800 for AC motors, compact and complete
6-7
8 - 10
8 - 10
11 - 12
13 - 15
16 - 17
18
Start-up Assistant
19
Adaptive Programming
20
Control Solutions
ABBs ready-made Control Solutions for specific drive applications
21
Centrifuge Control
22
Extruder Control
22
23
24
25
Others
ACS800 I/O
26
Control Panel
27
Fieldbus Control
28
Dynamic Braking
29 - 30
Output filters
31 - 32
33
34
35
36
37
38
39
ABB
ABB is one of the largest technology
companies in the world with broad
industry knowledge and geographic
scope. It has about 133,000 employees in around 100 countries and
occupies a leading position (1, 2 or
3) in each industry and product
areas it serves.
ABB offers complete industry and
process specific solutions, from
products to turnkey projects in
utilities, oil, gas and petrochemicals,
manufacturing and consumer
industries, and process industries.
ABB offers world-class collaborative
business platforms and solutions
based on IndustrialIT open architecture software.
AC drives
AC drives are used to control the
speed and torque of a standard
induction motor, the workhorse of
the industry. ABB is a market leader
in both motors and drives worldwide.
AC drive technology extends the
motor speed range from zero to
high above the rated speed, increasing the productivity of the driven
process. When a low capacity is
enough, the drive reduces the
machine speed and saves energy.
Accurate speed control of the
manufacturing process optimizes
the quality of the end product. The
Direct Torque Control (DTC)
developed by ABB has improved
control accuracy by making speed
encoders unnecessary.
ACS800
up to 2800 kW AC motors,
compact and complete.
Start-up Assistant
The heart of the ACS800 is DTC Direct Torque Control, its first class
motor control system. The consistently excellent performance of the
ACS800 guarantees that the drive
is not the limiting factor in your
process.
800
200
110
37
5.5
1.5
1.1
0.55
200
Adaptive Programming
240
380
415
500
690
Supply [V]
Environmentally sound
products
Mains connection
48...63 Hz
Power factor:
Efficiency
At nominal power:
ACS800-0x
ACS800-17
98%
97%
Motor connection
3-Phase output voltage: 0...U2IN/U3IN/U5IN//U7IN
Frequency control:
0...300 Hz
0...120 Hz with du/dt filters
8...300 Hz
Torque control:
Open loop
Closed loop
Open loop
Closed loop
Speed control:
Open loop
Closed loop
Open loop
Closed loop
Static accuracy:
10% of motor slip
0.01% of nominal speed
Dynamic accuracy:
0.3...0.4%sec. with 100% torque step
0.1...0.2%sec. with 100% torque step
Environmental limits
Ambient temperature:
Transportation:
Storage:
Operation:
-40...+70C
-40...+70C
-15...+50C, no frost allowed
40...50C at reduced output current (1%/1C).
Operation (ACS800-17):
0...+50C
Relative humidity:
Cooling method:
Altitude:
Fits anywhere
Both ACS800-01 and ACS800-02
drives are extremely compact
without sacrificing user-friendliness.
The ACS800-02 has a unique,
extremely compact bookshelf
design. When using bookshelf
mounting, even side-by-side installation is possible. In addition to
bookshelf mounting, the ACS800-02
offers a possibility for flat type
mounting enabling you to optimise
the width or depth depending on
your needs.
Everything inside
From the smallest ACS800-01 to
the biggest ACS800-02 there is an
extensive selection of in-built
features and accessories. The
standard features include a choke
Additionally in ACS800-02:
Free standing
Two mounting directions as
standard
Very narrow bookshelf design
Nominal
No-overload
Light-overload
Heavy-duty
Noise
Heat
ratings
use
use
use
level
dissipation
dBA
m3/h
V).
62
62
62
62
62
62
62
62
62
62
65
65
65
65
65
65
71
71
71
72
72
72
72
72
72
100
100
100
120
140
160
200
250
340
440
530
610
810
1190
1190
1440
2750
3350
3950
5300
6050
6550
7450
7850
8300
35
35
35
35
35
69
69
69
103
103
168
168
168
405
405
405
540
540
540
1220
1220
1220
1220
1220
1220
62
62
62
62
62
62
62
62
62
62
65
65
65
65
65
65
71
71
71
72
72
72
72
72
100
120
140
160
200
250
340
440
530
610
810
990
1190
1440
1940
2310
3050
3700
4300
6600
7200
8100
8650
9100
35
35
35
35
35
69
69
69
103
103
168
168
168
405
405
405
540
540
540
1220
1220
1220
1220
1220
I cont.max
A
P cont.max
kW
max
IN
A
PN
kW
P hd
kW
hd
Frame
size
Three phase supply voltage 208, 220, 230 or 240 V. The power ratings are valid at nominal voltage (230
ACS800-01-0001-2
5.1
6.5
1.1
4.7
0.75
3.4
0.55
R2
ACS800-01-0002-2
6.5
8.2
1.5
6.0
1.1
4.3
0.75
R2
ACS800-01-0003-2
8.5
10.8
1.5
7.7
1.5
5.7
1.1
R2
ACS800-01-0004-2
10.9
13.8
2.2
10.2
2.2
7.5
1.5
R2
ACS800-01-0005-2
13.9
17.6
3
12.7
3
9.3
2.2
R2
ACS800-01-0006-2
19
24
4
18
4
14
3
R3
ACS800-01-0009-2
25
32
5.5
24
5.5
19
4
R3
ACS800-01-0011-2
34
46
7.5
31
7.5
23
5.5
R3
ACS800-01-0016-2
44
62
11
42
11
32
7.5
R4
ACS800-01-0020-2
55
72
15
50
11
37
7.5
R4
ACS800-01-0025-2
72
86
18.5
69
18.5
49
11
R5
ACS800-01-0030-2
86
112
22
80
22
60
15
R5
ACS800-01-0040-2
103
138
30
94
22
69
18.5
R5
ACS800-01-0050-2
141
164
37
132
37
97
30
R6
ACS800-01-0060-2
166
202
45
155
45
115
30
R6
ACS800-01-0070-2
202
282
55
184
55
141
37
R6
ACS800-02-0080-2
214
326
55
211
55
170
45
R7
ACS800-02-0100-2
253
404
75
248
75
202
55
R7
55
R7
ACS800-02-0120-2
295
432
90
290
90
240 1)
ACS800-02-0140-2
405
588
110
396
110
316
90
R8
ACS800-02-0170-2
447
588
132
440
132
340
90
R8
ACS800-02-0210-2
528
588
160
516
160
370
110
R8
ACS800-02-0230-2
613
840
160
598
160
480
132
R8
160
R8
ACS800-02-0260-2
693
1017
200
679
200
590 2)
3)
ACS800-02-0300-2
720
1017
200
704
200
635
200
R8
Three phase supply voltage 380, 400 or 415 V. The power ratings are valid at nominal voltage (400 V).
ACS800-01-0003-3
5.1
6.5
1.5
4.7
1.5
3.4
1.1
R2
ACS800-01-0004-3
6.5
8.2
2.2
5.9
2.2
4.3
1.5
R2
ACS800-01-0005-3
8.5
10.8
3
7.7
3.0
5.7
2.2
R2
ACS800-01-0006-3
10.9
13.8
4
10.2
4.0
7.5
3.0
R2
ACS800-01-0009-3
13.9
17.6
5.5
12.7
5.5
9.3
4.0
R2
ACS800-01-0011-3
19
24
7.5
18
7.5
14
5.5
R3
ACS800-01-0016-3
25
32
11
24
11
19
7.5
R3
ACS800-01-0020-3
34
46
15
31
15
23
11
R3
ACS800-01-0025-3
44
62
22
41
18.5
32
15
R4
ACS800-01-0030-3
55
72
30
50
22
37
18.5
R4
ACS800-01-0040-3
72
86
37
69
30
49
22
R5
ACS800-01-0050-3
86
112
45
80
37
60
30
R5
ACS800-01-0060-3
103
138
55
94
45
69
37
R5
ACS800-01-0070-3
141
164
75
132
55
97
45
R6
ACS800-01-0100-3
166
202
90
155
75
115
55
R6
ACS800-01-0120-3
202
282
110
184
90
141
75
R6
ACS800-02-0140-3
206
326
110
202
110
163
90
R7
ACS800-02-0170-3
248
404
132
243
132
202
110
R7
1)
ACS800-02-0210-3
289
432
160
284
160
240
132
R7
ACS800-02-0260-3
445
588
200
440
200
340
160
R8
ACS800-02-0320-3
521
588
250
516
250
370
200
R8
ACS800-02-0400-3
602
840
315
590
315
477
250
R8
315
R8
ACS800-02-0440-3
693
1017
355
679
355
590 2)
ACS800-02-0490-3
720
1017
400
704
400
635 3)
355
R8
Air flow
Enclosure
Degree of Protection:
IP 21 (Standard)
IP 55 (Optional) for ACS800-01
Paint color:
NCS 1502-Y (RAL 90021/PMS 420C)
Type
R2
R3
R4
R5
R6
R7
R8
*)
IP 21
IP 55
H1
mm
H2
mm
W1
mm
W2
mm
Depth
mm
Weight
kg
Weight with
enclosure
extension *) kg
H1
mm
W1
mm
Depth
mm
Weight
kg
405
471
606
739
880
1507
2024
370 C)
420 C)
490 C)
602 C)
700 C)
N/A
N/A
165
173
240
265
300
250 A)
347 A)
N/A
N/A
N/A
N/A
N/A
602
793
226
265
274
286
400
520 A) B)
617 A) B)
9
12
26
37
67
110
240
N/A
N/A
N/A
N/A
N/A
234
450
528
528
774
775
923
N/A
N/A
263
263
377
377
420
N/A
N/A
242
273
278
308
427
N/A
N/A
16
18
32
50
77
N/A
N/A
Weights are for the basic configuration with switch fuse, but without contactor and other options.
Nominal
No-overload
Light-overload
Heavy-duty
Noise
Heat
ratings
use
use
use
level
dissipation
dBA
I cont.max
A
max
P cont.max
kW
IN
A
PN
kW
hd
P hd
kW
Frame
size
Three phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V. The power ratings are valid at nominal voltage (500 V).
ACS800-01-0004-5
4.9
6.5
2.2
4.5
2.2
3.4
1.5
R2
62
120
ACS800-01-0005-5
6.2
8.2
3
5.6
3.0
4.2
2.2
R2
62
140
ACS800-01-0006-5
8.1
10.8
4
7.7
4.0
5.6
3.0
R2
62
160
ACS800-01-0009-5
10.5
13.8
5.5
10
5.5
7.5
4.0
R2
62
200
ACS800-01-0011-5
13.2
17.6
7.5
12
7.5
9.2
5.5
R2
62
250
ACS800-01-0016-5
19
24
11
18
11
13
7.5
R3
62
340
ACS800-01-0020-5
25
32
15
23
15
18
11
R3
62
440
ACS800-01-0025-5
34
46
18.5
31
18.5
23
15
R3
62
530
ACS800-01-0030-5
42
62
22
39
22
32
18.5
R4
62
610
ACS800-01-0040-5
48
72
30
44
30
36
22
R4
62
810
ACS800-01-0050-5
65
86
37
61
37
50
30
R5
65
990
ACS800-01-0060-5
79
112
45
75
45
60
37
R5
65
1190
ACS800-01-0070-5
96
138
55
88
55
69
45
R5
65
1440
ACS800-01-0100-5
124
164
75
115
75
88
55
R6
65
1940
ACS800-01-0120-5
157
202
90
145
90
113
75
R6
65
2310
ACS800-01-0140-5
180
282
110
163
110
141
90
R6
65
2810
ACS800-02-0170-5
196
326
132
192
132
162
110
R7
71
3050
ACS800-02-0210-5
245
384
160
240
160
192
132
R7
71
3850
ACS800-02-0260-5
289
432
200
284
200
224
160
R7
71
4550
ACS800-02-0320-5
440
588
250
435
250
340
200
R8
72
6850
ACS800-02-0400-5
515
588
315
510
315
370
250
R8
72
7850
ACS800-02-0440-5
550
840
355
545
355
490
315
R8
72
7600
355
R8
72
8100
ACS800-02-0490-5
602
840
400
590
400
515 2)
ACS800-02-0550-5
684
1017
450
670
450
590 2)
400
R8
72
9100
ACS800-02-0610-5
718
1017
500
704
500
632 3)
450
R8
72
9700
Three phase supply voltage 525, 575, 600, 660 or 690 V. The power ratings are valid at nominal voltage (690 V).
ACS800-01-0011-7
13
14
11
11.5
7.5
8.5
5.5
R4
62
300
ACS800-01-0016-7
17
19
15
15
11
11
7.5
R4
62
340
ACS800-01-0020-7
22
28
18.5
20
15
15
11
R4
62
440
ACS800-01-0025-7
25
38
22
23
18.5
19
15
R4
62
530
ACS800-01-0030-7
33
44
30
30
22
22
18.5
R4
62
610
ACS800-01-0040-7
36
54
30
34
30
27
22
R4
62
690
ACS800-01-0050-7
51
68
45
46
37
34
30
R5
65
840
ACS800-01-0060-7
57
84
55
52
45
42
37
R5
65
1010
ACS800-01-0070-7
79
104
75
73
55
54
45
R6
65
1220
ACS800-01-0100-7
93
124
90
86
75
62
55
R6
65
1650
ACS800-01-0120-7
113
172
110
108
90
86
75
R6
65
1960
Nominal Ratings:
Icont.max: rated current available continuously without
overloadability at 40C.
Imax: maximum output current. Available for 10 s at
start, otherwise as long as allowed by drive
temperature. Note: max. motor shaft power is
150% Phd.
1)
Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload use.
Light-overload use
IN: continuous current allowing 110% IN for
1min/ 5 min at 40C.
PN: typical motor power in light-overload use.
Heavy-duty use
Ihd: continuous current allowing 150% Ihd for
1min/ 5 min at 40C.
Phd: typical motor power in heavy-duty use.
10
2)
3)
4)
Air flow
m3/h
35
35
35
35
35
69
69
69
103
103
168
168
168
405
405
405
540
540
540
1220
1220
1220
1220
1220
1220
103
103
103
103
103
103
168
168
405
405
405
Optimized construction
The ACS800-04 has several benefits
that make it the optimal choice for
panel builders.
No special EMC proof cabinets are
needed. In ACS800-04 drives with
in-built EMC filtering, both radiated
and conducted emissions are
restricted to EN 61800-3 limits
without the need for any extra
hardware.
Innovative fixing mechanics which
minimize the number of bolts facilitate the attachment of the drive
module. Fixing of the control unit
and control panel is easy thanks to
the DIN rail mounting and new type
of mounting platform.
The compact size with plenty of
built-in options minimizes both
space requirements and the amount
of assembly work needed.
Easy cabling
The easily accessible power terminals with plenty of space around
them make power cabling for the
ACS800-04 easy. Moreover, a
separate control unit enables easy
access to the I/O terminals. The
control unit can be optimally sited
inside the cabinet to enable access
to the I/O terminals without needing to open the drive module.
Maximised flexibility
Thanks to modular design ACS80004 offers wide variety of installation
possibilities. Both bookshelf
mounting for optimised width and
flat type mounting for optimised
depth are available.
Main standard hardware
features:
Optimised design for cabinet
assembly
EMC compliant module
Modular design allowing wide
variety of variants
Easy access to power terminals
Easy access and free location of
I/O terminals
Compact design
Harmonic filtering choke inside
Long life time cooling fan and
capacitors
Extensive, programmable I/O
Inputs galvanically isolated
Three I/O and fieldbus extension
slots inside
Large power terminals allowing
use of over sized or aluminium
cable
11
Nominal
No-overload
Light-overload
Heavy-duty
Noise
Heat
ratings
use
use
use
level
dissipation
dBA
I cont.max
A
max
P cont.max
kW
IN
A
PN
kW
hd
P hd
kW
Frame
size
Air flow
m3/h
Three phase supply voltage 208, 220, 230 or 240 V. The power ratings are valid at nominal voltage (230 V).
ACS800-04/04M-0080-2
214
326
55
211
55
170
45
R7
71
2750
ACS800-04/04M-0100-2
253
404
75
248
75
202
55
R7
71
3350
55
R7
71
3950
ACS800-04/04M-0120-2
295
432
90
290
90
240 1)
ACS800-04/04M-0140-2
405
588
110
396
110
316
90
R8
72
5300
ACS800-04/04M-0170-2
447
588
132
440
132
340
90
R8
72
6050
ACS800-04/04M-0210-2
528
588
160
516
160
370
110
R8
72
6550
ACS800-04/04M-0230-2
613
840
160
598
160
480
132
R8
72
7450
ACS800-04/04M-0260-2
693
1017
200
679
200
590 2)
160
R8
72
7850
ACS800-04/04M-0300-2
720
1017
200
704
200
635 3)
200
R8
72
8300
Three phase supply voltage 380, 400 or 415 V. The power ratings are valid at nominal voltage (400 V).
ACS800-04/04M-0140-3
206
326
110
202
110
163
90
R7
71
3050
ACS800-04/04M-0170-3
248
404
132
243
132
202
110
R7
71
3700
132
R7
71
4300
ACS800-04/04M-0210-3
289
432
160
284
160
240 1)
ACS800-04/04M-0260-3
445
588
200
440
200
340
160
R8
72
6600
ACS800-04/04M-0320-3
521
588
250
516
250
370
200
R8
72
7200
ACS800-04/04M-0400-3
602
840
315
590
315
477
250
R8
72
8100
2)
ACS800-04/04M-0440-3
693
1017
355
679
355
590
315
R8
72
8650
3)
ACS800-04/04M-0490-3
720
1017
400
704
400
635
355
R8
72
9250
Three phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V. The power ratings are valid at nominal voltage (500 V).
ACS800-04/04M-0170-5
196
326
132
192
132
162
110
R7
71
3050
ACS800-04/04M-0210-5
245
384
160
240
160
192
132
R7
71
3850
ACS800-04/04M-0260-5
289
432
200
284
200
224
160
R7
71
4550
ACS800-04/04M-0320-5
440
588
250
435
250
340
200
R8
72
6850
ACS800-04/04M-0400-5
515
588
315
510
315
370
250
R8
72
7850
ACS800-04/04M-0440-5
550
840
355
545
355
490
315
R8
72
7600
2)
ACS800-04/04M-0490-5
602
840
400
590
400
515
355
R8
72
8100
2)
ACS800-04/04M-0550-5
684
1017
450
670
450
590
400
R8
72
9100
3)
ACS800-04/04M-0610-5
718
1017
500
704
500
632
450
R8
72
9700
Three phase supply voltage 525, 575, 600, 660 or 690 V. The power ratings are valid at nominal voltage (690 V).
ACS800-04/04M-0140-7
134
190
132
125
110
95
90
R7
71
2800
ACS800-04/04M-0170-7
166
263
160
155
132
131
110
R7
71
3750
294
160
165/195 4)
160
147
132
R7
71
4250
ACS800-04/04M-0210-7 166/203 4)
ACS800-04/04M-0260-7 175/230 4)
326
160/200 4) 175/212 4) 200 4)
163
160
R7
71
4800
ACS800-04/04M-0320-7
315
433
315
290
250
216
200
R8
72
6150
ACS800-04/04M-0400-7
353
548
355
344
315
274
250
R8
72
6650
ACS800-04/04M-0440-7
396
656
400
387
355
328
315
R8
72
7400
ACS800-04/04M-0490-7
445
775
450
426
400
387
355
R8
72
8450
ACS800-04/04M-0550-7
488
853
500
482
450
426
400
R8
72
8300
ACS800-04/04M-0610-7
560
964
560
537
500
482
450
R8
72
9750
Nominal Ratings:
Icont.max : rated current available continuously without
overloadability at 40C.
IMAX : maximum output current. Available for 10 s at
start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd .
Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload use.
Light-overload use
IN: continuous current allowing 110% IN for
1min/ 5 min at 40C.
PN: typical motor power in light-overload use.
Notes:
50% overload available if T amb < 25C.
If Tamb = 40C, max overload for 1 min is 37%.
50% overload available if T amb < 30C.
If Tamb = 40C, max overload for 1 min is 40%.
3)
4)
540
540
540
1220
1220
1220
1220
1220
540
540
540
1220
1220
1220
1220
1220
1220
540
540
540
540
1220
1220
1220
1220
1220
1220
Enclosure
1)
2)
540
540
540
1220
1220
1220
1220
1220
1220
Degree of Protection:
IP 00
Paint color:
NCS 1502-Y (RAL 90021/PMS 420C)
Type
Height
mm
RDCU control unit *) 282
*)
Width Depth
mm
mm
126
41
Bookshelf design
Heavy-duty use
Ihd : continuous current allowing 150% Ihd for
1min/ 5 min at 40C.
Type
R7
R8
Width
mm
426
571
Depth
mm
467
564
Weight
kg
100
205
12
Height
mm
1121
1558
Height
mm
1152
1589
Width
mm
631
779
Depth
mm
259
356
Weight
kg
100
205
Customised solutions
ACS800-07 is a cabinet built single
drive designed for industrial applications. It covers a wide power range
and is very compact, the 2800 kW
drive is only 3.2 meters wide. It is
available with IP 21, IP 22, IP 42,
IP 54 and IP 54R protection classes.
The ACS800-07 offers a wide variety
of standardized configurations to
adapt to different application
requirements, from line contactor to
the prevention of unexpected motor
start, or ATEX approved motor
protection.
If your application requires more,
ABBs application engineering
services can add special features
to the standard product such as an
additional cabinet for customer
specific devices to ensure exact
suitability for the application.
13
Nominal
No-overload
Light-overload
Heavy-duty
Noise
Heat
ratings
use
use
use
level
dissipation
dBA
kW
m3/h
65
65
65
71
71
71
72
72
72
72
72
73
74
74
74
75
76
76
1.44
1.94
2.31
3.05
3.70
4.30
6.60
7.20
8.10
8.65
9.10
13.0
17.7
18.9
25.5
28.0
43.7
49.1
405
405
405
540
540
540
1220
1220
1220
1220
1220
3120
3840
3840
3840
5040
5760
6960
65
65
65
71
71
71
72
72
72
72
72
72
73
74
74
74
75
76
76
1.94
2.31
2.81
3.05
3.85
4.55
6.85
7.85
7.60
8.10
9.10
9.70
14.4
18.6
21.1
26.6
31.5
48.1
57.0
405
405
405
540
540
540
1220
1220
1220
1220
1220
1220
3120
3840
3840
3840
5040
5760
6960
65
65
65
71
71
71
71
72
72
72
72
72
72
73
73
73
74
75
75
76
76
78
78
1.22
1.65
1.96
3.00
3.75
4.45
4.80
6.15
6.65
7.40
8.45
8.30
9.75
15.3
18.5
19.4
23.9
29.2
35.4
42.2
56.5
68.3
91.2
405
405
405
540
540
540
540
1220
1220
1220
1220
1220
1220
3120
3120
3120
3840
5040
5040
6240
6960
9360
10080
I cont.max
A
I max
A
P cont.max
kW
IN
A
PN
kW
hd
P hd
kW
Frame
size
Three phase supply voltage 380, 400 or 415 V. The power ratings are valid at nominal voltage (400 V).
ACS800-07-0070-3
141
164
75
132
55
97
45
R6
ACS800-07-0100-3
166
202
90
155
75
115
55
R6
ACS800-07-0120-3
202
282
110
184
90
141
75
R6
ACS800-07-0140-3
206
326
110
202
110
163
90
R7
ACS800-07-0170-3
248
404
132
243
132
202
110
R7
132
R7
ACS800-07-0210-3
289
432
160
284
160
240 1)
ACS800-07-0260-3
445
588
200
440
200
340
160
R8
ACS800-07-0320-3
521
588
250
516
250
370
200
R8
ACS800-07-0400-3
602
840
315
590
315
477
250
R8
2)
ACS800-07-0440-3
693
1017
355
679
355
590
315
R8
ACS800-07-0490-3
720
1017
400
704
400
635 3)
355
R8
ACS800-07-0610-3
879
1313
500
844
500
657
400
1xD4 + 2xR8i
ACS800-07-0770-3
1111
1519
630
1067
630
830
450
2xD4 + 2xR8i
ACS800-07-0870-3
1255
1876
710
1204
710
938
500
2xD4 + 2xR8i
ACS800-07-1030-3
1452
1987
800
1394
800
1086
630
2xD4 + 2xR8i
ACS800-07-1230-3
1770
2648
1000
1700
1000
1324
710
2xD4 + 3xR8i
ACS800-07-1540-3
2156
2950
1200
2070
1200
1612
900
3xD4 + 3xR8i
ACS800-07-1850-3
2663
3983
1450
2557
1450
1992
1120
3xD4 + 4xR8i
Three phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V. The power ratings are valid at nominal voltage (500 V).
ACS800-07-0100-5
124
164
75
115
75
88
55
R6
ACS800-07-0120-5
157
202
90
145
90
113
75
R6
ACS800-07-0140-5
180
282
110
163
110
141
90
R6
ACS800-07-0170-5
196
326
132
192
132
162
110
R7
ACS800-07-0210-5
245
384
160
240
160
192
132
R7
ACS800-07-0260-5
289
432
200
284
200
224
160
R7
ACS800-07-0320-5
440
588
250
435
250
340
200
R8
ACS800-07-0400-5
515
588
315
510
315
370
250
R8
ACS800-07-0440-5
550
840
355
545
355
490
315
R8
2)
ACS800-07-0490-5
602
840
400
590
400
515
355
R8
2)
ACS800-07-0550-5
684
1017
450
670
450
590
400
R8
ACS800-07-0610-5
718
1017
500
704
500
632 3)
450
R8
ACS800-07-0760-5
883
1318
630
847
630
659
500
1xD4 + 2xR8i
ACS800-07-0910-5
1050
1521
710
1008
710
784
560
2xD4 + 2xR8i
ACS800-07-1090-5
1258
1880
900
1208
900
940
630
2xD4 + 2xR8i
ACS800-07-1210-5
1372
1989
1000
1317
1000
1025
710
2xD4 + 2xR8i
ACS800-07-1540-5
1775
2653
1250
1704
1200
1326
900
2xD4 + 3xR8i
ACS800-07-1820-5
2037
2953
1450
1956
1400
1522
1120
3xD4 + 3xR8i
ACS800-07-2310-5
2670
3990
1900
2563
1850
1995
1400
3xD4 + 4xR8i
Three phase supply voltage 525, 575, 600, 660 or 690 V. The power ratings are valid at nominal voltage (690 V).
ACS800-07-0070-7
79
104
75
73
55
54
45
R6
ACS800-07-0100-7
93
124
90
86
75
62
55
R6
ACS800-07-0120-7
113
172
110
108
90
86
75
R6
ACS800-07-0140-7
134
190
132
125
110
95
90
R7
ACS800-07-0170-7
166
263
160
155
132
131
110
R7
ACS800-07-0210-7
166/203 4)
294
160
165/195 4)
160
147
132
R7
ACS800-07-0260-7
175/230 4)
326
160/200 4)
175/212 4)
200
163
160
R7
ACS800-07-0320-7
315
433
315
290
250
216
200
R8
ACS800-07-0400-7
353
548
355
344
315
274
250
R8
ACS800-07-0440-7
396
656
400
387
355
328
315
R8
ACS800-07-0490-7
445
775
450
426
400
387
355
R8
ACS800-07-0550-7
488
853
500
482
450
426
400
R8
ACS800-07-0610-7
560
964
560
537
500
482
450
R8
ACS800-07-0750-7
628
934
630
603
630
467
500
1xD4 + 2xR8i
ACS800-07-0870-7
729
1084
710
700
710
542
560
1xD4 + 2xR8i
ACS800-07-1060-7
885
1318
800
849
800
659
630
1xD4 + 2xR8i
ACS800-07-1160-7
953
1419
900
914
900
710
710
2xD4 + 2xR8i
ACS800-07-1500-7
1258
1874
1200
1208
1200
937
900
2xD4 + 3xR8i
ACS800-07-1740-7
1414
2107
1400
1358
1400
1053
1000
2xD4 + 3xR8i
ACS800-07-2120-7
1774
2643
1700
1703
1700
1322
1250
2xD4 + 4xR8i
ACS800-07-2320-7
1866
2780
1900
1792
1800
1390
1400
3xD4 + 4xR8i
ACS800-07-3190-7
2665
3970
2600
2559
2500
1985
1900
3xD4 + 6xR8i
ACS800-07-3490-7
2770
4127
2800
2659
2700
2063
2100
4xD4 + 6xR8i
14
Air flow
Nominal Ratings:
Icont.max: rated current available continuously
without overloadability at 40C.
Notes:
1)
50% overload available if Tamb < 25C.
If Tamb = 40C, max overload for 1 min is 37%.
2)
3)
4)
5)
Typical Ratings:
No-overload use
Pcont.max: typical motor power in no-overload
use.
Light-overload use
IN: continuous current allowing 110% IN for
1min/ 5 min at 40C.
PN: typical motor power in light-overload use.
Heavy-duty use
Ihd: continuous current allowing 150% Ihd for
1min/ 5 min at 40C.
Phd: typical motor power in heavy-duty use.
The current ratings are the same regardless
of the supply voltage within one voltage
range.
The ratings apply at 40C ambient temperature.
At higher temperatures (up to 50C) the
derating is 1%/1C.
Enclosure
Degr
ee of Pr
otection:
Degree
Protection:
IP 21 (Standard)
IP 22, IP 42, IP 54, IP54R (Optional)
Paint color:
Light beige RAL 7035 semi-gloss
Frame
size
R6
R7
R8
1xD4 + 2xR8i
2xD4 + 2xR8i
2xD4 + 3xR8i
2xD4 + 4xR8i
3xD4 + 3xR8i
3xD4 + 4xR8i
3xD4 + 6xR8i
4xD4 + 6xR8i
Width *)
1330
1630
1830
2230
2030
2430
2830
3230
430 5)
830
830
1730
2030
2230
2630
2630
3030
3430
4030
Height *)
Height *) Depth *) Depth top
IP 21/22/42
IP 54
entry/exit *)
2130
2130
2130
2130
2130
2130
2130
2130
2130
2130
2130
2315
2315
2315
2315
2315
2315
2315
2315
2315
2315
2315
646
646
646
646
646
646
646
646
646
646
646
646
646
646
730
730
730
730
730
730
730
730
Weight
kg
890
1200
1350
1680
1540
1870
2170
2520
300
400
500
1100
1410
1560
1890
1800
2130
2430
2940
*) mm
15
Energy savings
LCL filter
ACS800 main modules
Line
inverter
(rectifier)
Motor
inverter
Motor
cont max
P cont max
kW
I_4/5 min
I_50/60 s
I_10/60 s
Frame
size
A (AC)
I max
A (AC)
A (AC)
I_1/5 min
A (AC)
Width 2)
mm
Weight
Noise
Ploss
Air flow
kg
level
dB
kW
m3/h
4.1
6.0
7.3
8.9
11.2
13.9
22.0
27.2
31.7
39.3
1920
3650
3650
3650
3650
3650
7280
7280
10330
10330
3.4
4.9
7.2
8.8
11.1
13.7
17.4
27.3
31.7
38.9
48.7
1920
1920
3650
3650
3650
3650
3650
7280
7280
10330
10330
7.2
8.8
10.9
13.4
17.2
27.0
31.3
38.1
48.7
3650
3650
3650
3650
3650
7280
7280
10330
10330
Three phase supply voltage 380, 400 or 415 V. The power ratings are valid at nominal voltage (400 V).
ACS800-17-0120-3
178
90
147
221
147
294
R7i
2130
730
305
63
ACS800-17-0185-3
259
132
194
291
178
356
R8i
2130
1230
625
63
ACS800-17-0225-3
312
160
234
351
216
432
R8i
2130
1230
625
63
ACS800-17-0265-3
379
200
284
426
260
520
R8i
2130
1230
625
63
ACS800-17-0335-3
474
250
356
533
316
632
R9i
2130
1230
655
63
ACS800-17-0405-3
576
315
432
648
395
790
R9i
2130
1230
655
63
ACS800-17-0630-3
907
500
680
1020
600
1200
R11i
2130
3630
1490
68
ACS800-17-0765-3
1094
630
821
1231
751
1502
R11i
2130
3630
1490
68
ACS800-17-0935-3
1336
710
1002
1503
901
1802
R12i
2130
4630
2530
71
ACS800-17-1125-3
1624
900
1218
1827
1126
2252
R12i
2130
4630
2530
71
Three phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V. The power ratings are valid at nominal voltage (500 V).
ACS800-17-0100-5
112
75
84
126
84
168
R6i
2130
730
305
63
ACS800-17-0140-5
164
110
135
203
135
270
R7i
2130
730
305
63
ACS800-17-0215-5
246
160
185
277
164
328
R8i
2130
1230
625
63
ACS800-17-0255-5
295
200
221
332
200
400
R8i
2130
1230
625
63
ACS800-17-0325-5
368
250
276
414
240
480
R8i
2130
1230
625
63
ACS800-17-0395-5
448
315
336
504
300
600
R9i
2130
1230
655
63
ACS800-17-0495-5
565
400
424
636
365
730
R9i
2130
1230
655
63
ACS800-17-0770-5
887
630
665
998
570
1140
R11i
2130
3630
1490
68
ACS800-17-0935-5
1073
710
805
1208
694
1388
R11i
2130
3630
1490
68
ACS800-17-1090-5
1263
900
947
1421
855
1710
R12i
2130
4630
2530
71
ACS800-17-1385-5
1593
1120
1195
1793
1040
2080
R12i
2130
4630
2530
71
Three phase supply voltage 525, 575, 600, 660 or 690 V. The power ratings are valid at nominal voltage (690 V).
ACS800-17-0205-7
176
160
132
198
127
254
R8i
2130
1230
625
63
ACS800-17-0255-7
210
200
158
236
150
300
R8i
2130
1230
625
63
ACS800-17-0315-7
264
250
198
297
179
358
R8i
2130
1230
625
63
ACS800-17-0375-7
310
315
233
349
225
450
R9i
2130
1230
655
63
ACS800-17-0485-7
410
400
308
461
265
530
R9i
2130
1230
655
63
ACS800-17-0750-7
630
630
473
709
428
856
R11i
2130
3630
1730
68
ACS800-17-0900-7
755
710
566
849
504
1008
R11i
2130
3630
1730
68
ACS800-17-1045-7
874
900
656
983
641
1282
R12i
2130
4630
2530
71
ACS800-17-1385-7
1156
1120
867
1301
755
1510
R12i
2130
4630
2530
71
Notes:
1)
Cabinet height is 2130 mm, 2072 mm for IP 54R
2)
An additional 400 mm is required in frame size R11 with top exits
An additional 600 mm is required in frame size R12 with top exits
Cabinet depth is 731 mm
Dimensions limit the number of options in frames R6 / R7 / R8 / R9.
Enclosure
Degree of Protection:
IP 21 (Standard)
IP 22, IP 42, IP 54R (Optional)
Paint color:
Light beige RAL 7035 semi-gloss
12 pulse rectifier
18 pulse rectifier
ACS800-17
17
18
Software features
A complete set of standard software
features offers premium functionality and flexibility.
Accurate speed control
Accurate torque control without
speed feedback
Adaptive Programming
Automatic reset
Automatic start
Constant speeds
Controlled torque at zero speed
DC hold
DC Magnetizing
Diagnostics
Flux braking
Flux optimization
IR compensation
Master/follower control
Mechanical brake control
Motor identification
Parameter lock
Power loss ride-through
Process PID control
Programmable I/O
Scalar control
Speed controller tuning
Start-up Assistant
Trim function
User-selectable acceleration and
decelaration ramps
Pre-programmed protection
functions
A wide feature range provides
protection for the drive, motor and
the process.
Ambient temperature
DC overvoltage
DC undervoltage
Drive temperature
Input phase loss
Overcurrent
Power limits
Short circuit
Programmable protection
functions
Start-up Assistant
The easy way of commissioning.
L <- 0.0 rpm
0
** INFORMATION **
Press FUNC to start
guided motor set up
Basic set up
LANGUAGE ?
[ENGLISH]
Select(arrows)+ENTER
Motor set up
MOTOR NOM CURRENT ?
0A
Press FUNC for info
READY
READY TO
TO START
START
Features
Easy and fast commissioning
procedure
Intelligent guide to assist you
through the commissioning
Your own language
On-line info system always
available
The ACS800 offers you all this as a
standard feature.
19
Adaptive Programming
No extra hardware or software needed.
20
Optimal adaptability
Small PLC inside
Program your drive on-site during
commissioning
Create your own I/O signals,
modify speed or torque reference
chain or set a timer
Do it without any additional
hardware or software
As simple as setting a parameter
There is also a PC tool available for
Adaptive Programming.
Features
15 programmable function blocks
Available functions:
Logical: AND, OR and XOR
Mathematical: add, mul, div,
abs, max and min
Other: timer, switch, comparator,
filter, SR, PI and user defined
warnings or faults
Freely definable execution order
Easy documentation
The ACS800 offers you all this as a
standard feature!
Control Solutions
ABBs ready-made Control Solutions for specific drive applications.
Centrifuge Control
Practical programmable sequences
for conventional centrifuges. Decanter Control for accurate speed
difference control of two shafts.
Extruder Control
High starting torque, accurate
speed/torque control and overload
protection for demanding extruder
applications.
Application-dedicated features
Improved production
No external PLC
User-friendly
Easy to use
Energy savings
Smooth power loss ridethrough
Reduced costs
Adaptive protections
Master/Follower Control
Reliable control via fibre optic link
of several drives when motor shafts
are coupled together.
21
Control Solutions
Centrifuge Control.
Centrifuge &
Decanter Centrifuge as one
The Centrifuge application consists
of programmable sequences for
centrifuges e.g. in the food and
beverage industries. The Decanter
Control is integrated with the
Centrifuge Control. This feature can
be applied in all applications
needing co-ordinated speed difference control.
Control Solutions
Extruder Control.
AC drives designed for
extruder applications
An extruder is an application where
material typically in granulate or
pulverized form is driven through a
screw to achieve a continuous
material form to be further modified
in the manufacturing process. Due
to the material characteristics high
starting torque is often needed. The
screw and also the delicate mechanical parts of the machinery
need to be protected against overload.
22
Extruder application
features
High starting torque, excellent
speed accuracy without encoder
Adaptive torque limitation feature
Two sets of parameterised stall
protection functions
Digital potentiometer with two
different accelerating and
decelerating ramp times
Four control locations
Control Solutions
Pump and Fan Control.
Introduction
There are many pump and fan
installations with quite extensive
flow variations. Such are water and
sewage systems, air conditioning,
district heating and different industrial applications. A common
solution for these is to run several
fixed speed pumps or fans in
parallel and flow control is made by
switching them on and off. This
Alternation
switchgear
cabinet
Pressure
transducer
0...10 bar
4...20 mA
M1
7.5 kW
1450 rpm
14.8 A
Features
The maximum number of units
(pumps or fans) in parallel is 5
(1 with speed control and 4 with
fixed speed)
PI controller with
setpoint adjustment internal or
external
actual value with five selectable
units
Setpoint steps for 4 motors
Sleep and wake up level and
delay settings
Start and low frequency settings
for 4 motors
Start and stop delays
Autochange delay and level
settings
Automatic interlocking between
motors
M2
7.5 kW
1450 rpm
14.8 A
23
Control Solutions
Spinning Control & Traverse Control.
ACS800
Spinning Control
Speed
Time
Pattern
Yarn
Bobbin
Doff
Motor
Gear
ACS800
Traverse Control
ACS800 with
Standard program
P-jump
function
Wobbulation function
Shiftwise production calculation
Automatic doff (pattern) selection
4 speed time patterns
24
Yarn package
Gear
Motor
Yarn guide
Yarn
Gear
Motor
Control Solutions
Crane Drive Control.
Outstanding performance
Operational safety
Mechanical brake functions for
controlling and supervising the
brake
Adjustable fast stop procedure in
case of overload or slack rope
etc.
Torque proving ensures that the
motor has produced sufficient
torque when opening the brakes
Speed monitoring ensures that
the speed stays within given
limits. Also zero speed detection
Torque monitoring supervises the
correlation between the speed
ordered and actual motor speed
25
ACS800 I/O
X20
1
2
X21
1
AI1+
4
5
AI1-
AI2AI3+
8
9
AI3-
10
AO1AO2+
Optional I/O
Analog I/O Extension Module RAIO-01
2 analog inputs: galvanically isolated from 24 V supply
and ground
- 0(2)...10 V, 0(4)... 20 mA or 0...2 V, resolution 12 bits
2 analog outputs: galvanically isolated from 24 V supply
and ground
- 0(4)...20 mA, resolution 12 bit
7
rpm
AI2+
AO1+
AO2-
^ 0...motor
Output current 0(4)...20 mA =
nom. current, RL < 700 ohm
DI1
DI2
Stop/Start
Forward/Reverse
3
4
DI3
5
6
DI5
DI6
7
8
10
11
X23
DI4
+24V
GND
X25
1
RO11
RO22
RO23
X27
1
RO31
12
X22
11
26
Below are the standard control connections of the ACS800 single drive
with Factory Macro. For other ACS800
application macros the functions
may be different.
RO12
RO13
X26
1
RO21
2
3
RO32
RO33
Control Panel
ACS800 with user-friendly functionality.
Fault memory
Actual value
The ACS800 control panel can
display three separate actual values
simultaneously.
Examples of these are:
Motor speed
Frequency
Current
Torque
Power
References
DC bus voltage
Output voltage
Heatsink temperature
Operating hours
Kilowatt hours
Parameter copying
Centralised
control
Simple
arrangement
Parameters are
organised into
groups for easy
programming.
Control Panel
Multilingual alphanumeric display
(4 lines x 20 characters) plain text
messages in 14 languages.
Intelligent removable control panel
can be mounted on the ACS800
enclosure or remotely.
Start-up Assistant
No extra hardware or
software required for
Adaptive Programming.
27
Fieldbus Control
Gateway to your process.
Manufacturing Flexibility
Drive control
The drive Control Word (16 bit)
provides a wide variety of functions
from Start, Stop and Reset to Ramp
Generator control. Typical setpoint
values like Speed, Torque and
Position can be transmitted to the
drive with 15 bit accuracy.
Drive monitoring
A set of drive parameters and/or
actual signals, like torque, speed,
position, current etc., can be selected for cyclic data transfer
providing fast data for operators
and the manufacturing process.
28
Drive diagnostics
Accurate and reliable diagnostic
information can be obtained via the
drive Alarm, Limit and Fault Words
reducing the down time of the drive
and therefore also the down time of
the manufacturing process.
Design
The use of Fieldbus Control reduces
engineering time at installation due
to the modular structure of the
hardware and software.
Easy to expand
Serial communication simplifies the
latest trend of modular machine
design enabling expansion of the
installation at a later stage with low
effort.
Cabling
Substituting the large amount of
conventional Drive Control cabling
with a single twisted pair reduces
costs and increases system reliability.
PROFIBUS-DP
DeviceNet
CANopen
ControlNet
ModbusPlus
LONWORKS
Modbus
Ethernet
InterBus-S
Dynamic Braking
Brake Choppers and Resistors.
Brake Chopper
Brake Resistor
The SACE/SAFUR brake resistors
are separately available for all
ACS800 types. Resistors other than
the standard resistors may be used
providing the specified resistance
value is not decreased, and the heat
dissipation capacity of the resistor is
sufficient for the drive application.
ACS800-01-0001-2
ACS800-01-0002-2
ACS800-01-0003-2
ACS800-01-0004-2
ACS800-01-0005-2
ACS800-01-0006-2
ACS800-01-0009-2
ACS800-01-0011-2
ACS800-01-0016-2
ACS800-01-0020-2
ACS800-01-0025-2
ACS800-01-0030-2
ACS800-01-0040-2
ACS800-01-0050-2
ACS800-01-0060-2
ACS800-01-0070-2
Brake Chopper
Power
Brake Resistor(s)
ACS800 type
Continuous
Pbrcont [kW]
Type
R
[Ohm]
Er
[kJ]
P rcont
[kW]
0.6
0.8
1.1
1.5
2.2
3
4
5.5
11
17
23
28
33
45
56
68
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE22
SACE15RE22
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR80F500
SAFUR125F500
SAFUR125F500
2 x SAFUR125F500
2 x SAFUR125F500
2 x SAFUR125F500
44
44
44
44
22
22
22
13
8
8
6
4
4
2
2
2
248
248
248
248
496
496
496
496
1800
1800
2400
3600
3600
7200
7200
7200
1
1
1
1
2
2
2
2
4.5
4.5
6
9
9
18
18
18
Brake Resistor(s)
5 / 60 s 10 / 60 s 30/60 s Continuous
Pbr5 [kW] Pbr10 [kW] Pbr30 [kW] Pbrcont [kW]
ACS800-02/04-0080-2
ACS800-02/04-0100-2
ACS800-02/04-0120-2
ACS800-02/04-0140-2
ACS800-02/04-0170-2
ACS800-02/04-0210-2
ACS800-02/04-0230-2
ACS800-02/04-0260-2
ACS800-02/04-0300-2
68
83
105
135
135
165
165
223
223
68
83
67
135
135
165
165
170
170
68
83
60
135
135
165
165
125
125
54
54
40
84
84
98
113
64
64
Type
R
[Ohm]
Er
[kJ]
P rcont
[kW]
SAFUR 160F380
SAFUR 160F380
2xSAFUR200F500
2xSAFUR160F380
2xSAFUR160F380
2xSAFUR160F380
2xSAFUR160F380
4xSAFUR160F380
4xSAFUR160F380
1.78
1.78
1.35
0.89
0.89
0.89
0.89
0.45
0.45
3600
3600
10800
7200
7200
7200
7200
14400
14400
9
9
27
18
18
18
18
36
36
ACS800-01-0003-3
ACS800-01-0004-3
ACS800-01-0005-3
ACS800-01-0006-3
ACS800-01-0009-3
ACS800-01-0011-3
ACS800-01-0016-3
ACS800-01-0020-3
ACS800-01-0025-3
ACS800-01-0030-3
ACS800-01-0040-3
ACS800-01-0050-3
ACS800-01-0060-3
ACS800-01/07-0070-3
ACS800-01/07-0100-3
ACS800-01/07-0120-3
Brake Chopper
Power
Brake Resistor(s)
ACS800 type
Continuous
Pbrcont [kW]
Type
R
[Ohm]
Er
[kJ]
P rcont
[kW]
1.1
1.5
2.2
3
4
5.5
7.5
11
23
28
33
45
56
68
83
113
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE22
SACE15RE22
SACE15RE13
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR90F575
SAFUR80F500
SAFUR125F500
SAFUR125F500
44
44
44
44
44
22
22
22
13
13
8
8
8
6
4
4
248
248
248
248
248
496
496
496
496
496
1800
1800
1800
2400
3600
3600
1
1
1
1
1
2
2
2
2
2
4.5
4.5
4.5
6
9
9
Brake Resistor(s)
5 / 60 s 10 / 60 s 30/60 s Continuous
Pbr5 [kW] Pbr10 [kW] Pbr30 [kW] Pbrcont [kW]
ACS800-02/04/07-0140-3
ACS800-02/04/07-0170-3
ACS800-02/04/07-0210-3
ACS800-02/04/07-0260-3
ACS800-02/04/07-0320-3
ACS800-02/04/07-0400-3
ACS800-02/04/07-0440-3
ACS800-02/04/07-0490-3
135
165
165
240
300
375
473
500
135
150
150
240
300
375
355
355
100
100
100
240
300
273
237
237
80
80
80
173
143
130
120
120
Type
R
[Ohm]
Er
[kJ]
P rcont
[kW]
SAFUR200F500
SAFUR200F500
SAFUR200F500
2XSAFUR210F575
2xSAFUR200F500
4xSAFUR125F500
4xSAFUR210F575
4xSAFUR210F575
2.70
2.70
2.70
1.70
1.35
1.00
0.85
0.85
5400
5400
5400
8400
10800
14400
16800
16800
13.5
13.5
13.5
21
27
36
42
42
29
ACS800-01-0004-5
ACS800-01-0005-5
ACS800-01-0006-5
ACS800-01-0009-5
ACS800-01-0011-5
ACS800-01-0016-5
ACS800-01-0020-5
ACS800-01-0025-5
ACS800-01-0030-5
ACS800-01-0040-5
ACS800-01-0050-5
ACS800-01-0060-5
ACS800-01-0070-5
ACS800-01/07-0100-5
ACS800-01/07-0120-5
ACS800-01/07-0140-5
Brake Chopper
Power
Brake Resistor(s)
ACS800 type
Continuous
Pbrcont [kW]
Type
R
[Ohm]
Er
[kJ]
P rcont
[kW]
1.5
2.2
3
4
5.5
7.5
11
15
28
33
45
56
68
83
113
135
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE22
SACE15RE22
SACE15RE13
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR90F575
SAFUR125F500
SAFUR125F500
SAFUR125F500
44
44
44
44
44
22
22
22
13
13
8
8
8
4
4
4
248
248
248
248
248
496
496
496
496
496
1800
1800
1800
3600
3600
3600
1
1
1
1
1
2
2
2
2
2
4.5
4.5
4.5
9
9
9
Brake Resistor(s)
5 / 60 s 10 / 60 s 30/60 s Continuous
Pbr5 [kW] Pbr10 [kW] Pbr30 [kW] Pbrcont [kW]
ACS800-02/04/07-0170-5
ACS800-02/04/07-0210-5
ACS800-02/04/07-0260-5
ACS800-02/04/07-0320-5
ACS800-02/04/07-0400-5
ACS800-02/04/07-0440-5
ACS800-02/04/07-0490-5
ACS800-02/04/07-0550-5
ACS800-02/04/07-0610-5
165
198
198 1)
300
375
473
480
600
600 3)
132 2)
132 2)
132 2)
300
375
473
480
400 4)
400 4)
120
120
120
300
375
450
470
300
300
80
80
80
300
234
195
210
170
170
Type
R
[Ohm]
Er
[kJ]
P rcont
[kW]
SAFUR200F500
SAFUR200F500
SAFUR200F500
2xSAFUR125F500
2XSAFUR210F575
2xSAFUR200F500
2xSAFUR200F500
4xSAFUR125F500
4xSAFUR125F500
2.70
2.70
2.70
2.00
1.70
1.35
1.35
1.00
1.00
5400
5400
5400
7200
8400
10800
10800
14400
14400
13.5
13.5
13.5
18
21
27
27
36
36
ACS800-01-0011-7
ACS800-01-0016-7
ACS800-01-0020-7
ACS800-01-0025-7
ACS800-01-0030-7
ACS800-01-0040-7
ACS800-01-0050-7
ACS800-01-0060-7
ACS800-01/07-0070-7
ACS800-01/07-0100-7
ACS800-01/07-0120-7
Brake Chopper
Power
Brake Resistor(s)
Continuous
Pbrcont [kW]
Type
R
[Ohm]
Er
[kJ]
P rcont
[kW]
5.5
7.5
11
15
18.5
22
30
37
45
55
75
SACE08RE44
SACE08RE44
SACE08RE44
SACE15RE22
SACE15RE13
SACE15RE13
SACE15RE13
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR90F575
44
44
44
22
13
13
13
13
8
8
8
248
248
248
496
496
496
496
496
1800
1800
1800
1
1
1
2
2
2
2
2
4.5
4.5
4.5
30
ACS800 type
Brake Resistor(s)
5 / 60 s 10 / 60 s
30/60 s Continuous
Pbr5 [kW] Pbr10 [kW] Pbr30 [kW] Pbrcont [kW]
ACS800-04/07-0140-7
ACS800-04/07-0170-7
ACS800-04/07-0210-7
ACS800-04/07-0260-7
ACS800-04/07-0320-7
ACS800-04/07-0400-7
ACS800-04/07-0440-7
ACS800-04/07-0490-7
ACS800-04/07-0550-7
ACS800-04/07-0610-7
125 5)
125 6)
125 6)
135 7)
300
375
430
550
550
550
1)
2)
3)
4)
5)
6)
7)
110
110
110
120
300
375
430
400
400
400
90
90
90
100
300
375
430
315
315
315
75
75
75
80
260
375
385
225
225
225
Brake Resistor
SACE08RE44
SACE15RE22
SACE15RE13
SAFUR80F500
SAFUR90F575
SAFUR180F460
SAFUR125F500
SAFUR200F500
SAFUR210F575
Type
R
[Ohm]
Er
[kJ]
P rcont
[kW]
SAFUR80F500
SAFUR80F500
SAFUR80F500
SAFUR80F500
SAFUR200F500
SAFUR200F500
SAFUR200F500
2xSAFUR125F500
2xSAFUR125F500
2xSAFUR125F500
6.00
6.00
6.00
6.00
2.70
2.70
2.70
2.00
2.00
2.00
2400
2400
2400
2400
5400
5400
5400
7200
7200
7200
6
6
6
6
13.5
13.5
13.5
18
18
18
Height
mm
365
365
365
600
600
1320
1320
1320
1320
Width
mm
290
290
290
300
300
300
300
300
300
Depth Weight
mm
kg
131
6.1
131
6.1
131
6.8
345
14
345
12
345
32
345
25
345
30
345
27
Output filters
Factory installed and external filters.
Nominal mains
voltage (UN)
UN 500 V
500 V < UN 600 V
600 V < UN 690 V
380 V < UN 690 V
380 V < UN 690 V
UN 420 V
420 V < UN 500 V
500 V < UN 600 V
Symbol
UN
LL
t
Explanation
Nominal mains voltage.
Peak line to line voltage at motor terminals.
Rise time, i.e. interval during which line to line voltage at motor terminals changes from 10% to 90% of full
voltage range.
31
Applicability
Factory-installed du/dt filters are
available for ACS800-07/-17. They
are installed inside the converter
cubicle. The filters are also separately available for other ACS800
types.
Then they need to be mounted
externally. Unprotected (IP 00)
filters must be encased.
-0004-5
-0005-5
-0006-5
-0009-5
-0011-5 -0011-7
-0016-5
-0016-3 -0020-5 -0016-7
-0020-3
-0020-7
-0025-7
-0025-3 -0025-5 -0030-7
-0030-3 -0030-5 -0040-7
-0040-3 -0040-5 -0050-7
-0050-3 -0050-5 -0060-7
-0060-5
-0060-3 -0070-5 -0070-7
-0070-3 -0100-5 -0100-7
-0120-7
-0100-3 -0120-5
-0120-3 -0140-5
-0140-3 -0170-5 -0140-7
-0170-3 -0210-5 -0170-7
-0210-3 -0260-5 -0210-7
-0260-3 -0320-5 -0260-7
-0320-3 -0400-5 -0320-7
-0400-7
-0400-3 -0440-5 -0440-7
-0440-3 -0490-5 -0490-7
-0490-3 -0550-5 -0550-7
-0610-5 -0610-7
1
1
1
2
Height
mm
Width
mm
Depth
mm
Weight
kg
NOCH0016-60
195
140
115
2.4
NOCH0016-62/65
323
199
154
NOCH0030-60
215
165
130
4.7
NOCH0030-62/65
348
249
172
NOCH0070-60
261
180
150
9.5
15.5
NOCH0070-62/65
433
279
202
NOCH0120-60**
200
154
106
NOCH0120-62/65
765
308
256
45
AOCH0260-70**
190
340
242
15.9
AOCH0400-70**
190
340
257
20.7
NOCH0120-65
NOCH0070-65
NOCH0030-65
NOCH0016-65
NOCH0120-62
NOCH0070-62
32
NOCH0030-62
NOCH0016-62
*AOCH0400-70
*AOCH0260-70
*NOCH0260-60
*NOCH0120-60
690 V
NOCH0070-60
500 V
NOCH0030-60
400 V
-0003-3
-0004-3
-0005-3
-0006-3
-0009-3
-0011-3
NOCH0016-60
ACS800
Protected
to IP 54
Protected
to IP 22
Programming Tool
DriveAP for Adaptive Programming.
Upload or download
Features
Easy to use tool, no special skills
required
Create and download new
programs
Document your programs
Upload existing programs from
the drive
Operating modes
Stand Alone
Off-Line
On-Line
33
Integration Tool
DriveOPC for Windows based monitoring.
DriveOPC
DriveOPC is a software package
which allows OLE for Process
Control (OPC) communication
between Windows applications and
ABB drives. It is an ideal tool for
integrating commercial PC monitoring software and ABB drives.
DriveOPC can access all drives
connected to the fast optical link
of the drives. The number of
measuring points is unlimited.
Remote monitoring
DriveOPC enables remote connection over LAN (local area
networks). The remote PC can be
connected by its IP address (e.g.
"164.12.43.33") or by the DNS name
(e.g. "Gitas213").
34
Features:
To control and monitor with PCbased process control software
Standard interface
Remote connection over LAN
(local area networks)
Access to
Drive control
Signals and parameters
Data and Fault loggers
Engineering Tool
DriveSize for dimensioning motors and drives.
Quality dimensioning
DriveSize is a PC program for
helping the user to select an optimal motor, frequency converter and
transformer, especially in those
cases where a straightforward
selection from a catalogue is not
possible. Additionally it can be used
to compute currents, network
harmonics and to create documents
about the dimensioning based on
actual load. DriveSize contains a
current version of ABB motor and
frequency converter catalogues.
The default values make DriveSize
simple to use, but the user is provided with ample options for drive
selection. The shortcut keys make
drive selection easy while still
honouring the relatively complicated rules. A manual selection
mode is also supported.
DriveSize is currently used by more
than 1000 engineers globally.
DriveSize functions
The software performs dimensioning based on the following input:
Speed range and mechanical load
with overloads
Ambient temperature and
altitude
Required IP-class and allowed
temperature rise
Supply network characteristics
Load type and duty cycle
Optionally current requirements
for inverters
DC power requirement for line
supply unit
Apparent power requirement for
the transformer
Additional functions
The software also enables you to:
Calculate the network harmonics
of individual drive or set of
drives
Obtain efficiency values
See your selections in graphical
or numeric form
Select manually unit from the
database
Print out reports
Save the dimensioning results
into files
Benefits
Select an optimal motor,
frequency converter and
transformer
Dimensioning based on actual
shaft load
Documents dimensioning
results, graphical and numerical
presentation
Network harmonic and power
factor calculaton
Print out and save the results
35
Features
Easy-to-use tool for
commissioning and maintenance
Several drives connected and
monitored at the same time
Monitor, edit or save signals and
parameters, clear graphical
presentation
High speed communication
between PC and drive
Versatile back-up functions
Simple to use
The DriveWindow Light 2.1 is a
comprehensive commissioning and
maintenance tool for ABB drives.
This easy-to-use software is for
editing, uploading and downloading drive parameters and, for
example, monitoring the actual
values and status information of
the drive system.
DriveWindow Light 2.1 enables most
drive parameters to be set offline in
the office when uploaded from the
drive, and then saved in the drivespecific files. The files can be further
modified and downloaded to the
respective drives at the installation
site.
Practical functions
Parameter browser for editing
(online/offline) and viewing
parameter values online
Parameter compare function for
parameters in a drive and a
parameter file
Parameter back-up and restore
Easy adjustment of pointer type
parameters, e.g. Adaptive
Programming
Graphical and numerical
monitoring of signals
Control panel with step function
37
Browser-based, user-friendly
The intelligent Ethernet module
gives simple access to the drive via
the Internet communicating via a
standard web browser. The user
can set up a virtual monitoring
room wherever there is a PC with
an Internet connection or via a
simple dial-up modem connection.
This enables remote monitoring,
configuration, diagnostics and,
when needed, control. The drive
can also provide process related
information, such as load level, run
time, energy consumption and I/O
data, the bearing temperature of
the driven machine, for instance.
E-mail alerts
The module can also send condition
triggered event alerts to predefined
38
Features
Virtual monitoring room for
Monitoring
Configuration of parameters
Diagnostics
Control, if needed
Browser based access via
Intra-/extra-/Internet or
Simple dial-up modem
connection
E-mail alerts to predefined
addresses
No PC needed at the local end
Can be used as a Modbus/TCP
bridge for control purposes
AC drive efficiency
Motor efficiency in
AC drive use
Total efficiency
Efficiency, %
39
ABB Oy
Drives
P. O. Box 184
FIN - 00381 Helsinki
Finland
Telephone
+358 10 22 11
Telefax
+358 10 222 2681
Internet
http://www.abb.com/motors&drives
3AFE 64572504 REV E EN 17.10.2003 Specifications subject to change without notice.