MR 2G, 3G and LTE MoP

version 2.0

SA STC, project

Nokia Siemens Networks

Presentation / Author / Date

Part 1: 2G Site model Categories & Configuration for


modernization
No. of RF
Modules

Typical O/P
Power per
TRX

No. of antenna
lines per sector

No

Model Configuration

No. of System
Module

4+4+4

20 W

6+6+6

20 W

8+8+8

20 W

12+12+12

15 W

6+6+6/4+4+4

20 W

2/2

6+6+6/6+6+6

20 W

2/2

6+6+6/8+8+8

20 W

2/3

8+8+8/6+6+6

20 W

3/2

8+8+8/8+8+8

20 W

3/3

10

8+8+8/12+12+12

15 W

3/3

11

12+12+12/4+4+4

15 W

3/2

12

12+12+12/8+8+8

15 W

3/3

As per the BoQ: 2G 900:6+6+6, 2G 1800:4+4+4 ( 1 SM + 2 RFM GSM900 + 2


RFM GSM1800 )
2

Nokia Siemens Networks

Presentation / Author / Date

Part 1: 2G BTS System Module

Nokia Siemens Networks

Presentation / Author / Date

Part 1: 2G BTS RF Module

Nokia Siemens Networks

Presentation / Author / Date

Part 1: 2G BTS Product Structure


Flexi Multiradio 10 BTS
For 2G/3G/LTE/LTE-A
Pipe 1

Pipe 2

Pipe 3

Div Rx
Tx 60W/Rx

Div Rx
Tx 60W/Rx

Div Rx
Tx 60W/Rx

Alternativ
e RRH
site
solution

Flexi RF Module Triple


(3x60W) or (3x20W)

2G/3G/LTE/LTE-A
Flexi Multiradio
System Module,
2G/3G/LTE/LTE-A

Optional PDU

3G or LTE / BB
extension

Optional transport
interfaces

3G or LTE BB
extension

Alternative
Active
Antenna
site
solution

Alternative
Indoor
System
Module

2G, 3G or LTE baseband


core
Integrated IP transport

Existing Flexi RF Modules/RRHs can


be also connected to Flexi Multiradio
System Module

Nokia Siemens Networks

Presentation / Author / Date

Flexi MR BTS is structured based on 6+6+6


TRX Module
6+6+6 / 4+4+4

Nokia Siemens Networks

Presentation / Author / Date

Part 1: Feeder Connection to 2G Antenna

Nokia Siemens Networks

Presentation / Author / Date

Part 1: Feeder Connection to 2G Antenna

6+6+6 @ 900MHz
4+4+4 @1800MHz
6 TRXs
(20W)
10W

10W

Nokia Siemens Networks

Presentation / Author / Date

Part 1: 2G BTS feeder configurations

(max)6/6/6@10w per TRX or


3/3/3@ 20w per TRX or
4/4/4@15w per TRX or
2/2/2@20w/30w per TRX
1/1/1@60w per TRX

A
12/12/12 @10w per TRX or
8/8/8@15w per TRX or
6/6/6 @ 20w per TRX or
4/4/4 @ 20w per TRX
2/2/2 @60w per TRX

8 /8/8 @20w per TRX or

One sector shown

9/9/9 @ 20w per TRX or

12/12/12 @15w per TRX or


2/2/2@30w per TRX or

Nokia Siemens Networks

Presentation / Author / Date

12/12/12 @10w per


TRX or
8/8/8@15w per TRX or
6/6/6 @ 20w per TRX or
4/4/4 @ 20w per TRX
2/2/2 @60w per TRX

ESMB=max18TRx.
FXDA-900
FXEA-1800

Use sync cable for CBCCH if bands are in separate BCF


Example: when total TRX is more than 36.

900

1800

8/8/8 or

8/8/8 or

12/12/12

12/12/12

If the number of TRX is less than 36


RF chaining can be used for special configurations
10

Nokia Siemens Networks

Presentation / Author / Date

or more sectors

11

Nokia Siemens Networks

Presentation / Author / Date

Part 1: BTS with smaller configuration than 8 TRX


example

900

12

Nokia Siemens Networks

Presentation / Author / Date

2G MOP to Configure more than 6+6+6 / 4+4+4


example

13

Nokia Siemens Networks

Presentation / Author / Date

14

Nokia Siemens Networks

Presentation / Author / Date

15

Nokia Siemens Networks

Presentation / Author / Date

16

Nokia Siemens Networks

Presentation / Author / Date

Example
Site: ZMKA007
BSC GK12B3
6+8+6(900) / 4+8+4 (1800)

17

Nokia Siemens Networks

Presentation / Author / Date

18

Nokia Siemens Networks

Presentation / Author / Date

19

Nokia Siemens Networks

Presentation / Author / Date

Sample of configuration difference between Old


BTS type versus Flexi MR
3+3+3/4+4+4 Configuration

DTRX

WCDMA
WBC

Diplexer

DTRX
43W

20W

17W

MultiRadio

20W/15W
20

Nokia Siemens Networks

Presentation / Author / Date

Sample of configuration difference between Old


BTS type versus Flexi MR (1/2)
5+5+5/6+6+6 Configuration
DTRX

WCDMA
WBC

DTRX
20W

43W

DTRX

WCDMA
WBC

Diplexer

WBC
8.7W

MultiRadio
10W
21

Nokia Siemens Networks

Presentation / Author / Date

6W

Sample of configuration difference between Old


BTS type versus Flexi MR (2/2)
5+5+5/6+6+6 Configuration
DTRX

WCDMA
WBC

Diplexer
20W

DTRX

17W

43W
DTRX

43W

WCDMA
WBC

Diplexer
20W

17W

MultiRadio
10W
22

Nokia Siemens Networks

Presentation / Author / Date

2G A-bis Timeslot mapping table

NOTES
The above A-bis mapping is for the standard A-bis configuration which is
appearing most of the time in the network
Any odd configuration to be planned by NPO and shared with the rest of the
team before MDT

23

Nokia Siemens Networks

Presentation / Author / Date

Part 2: 3G Site model Categories & Configuration for


Modernization
The 3G configuration is based on 2 - 4 carriers. All configurations are based
on 30 W per carrier.
2+2+2 or 4+4+4 Flexi MR with FSME
3+3+3@42Mbps
software upgrdable to
4+4+4@84Mbps

24

Nokia Siemens Networks

Presentation / Author / Date

3G 3+3+3 @ 42 Mbps upgradable to 4+4+4 @


84Mbps
Single Band Antenna 3G
2100MHz
Existing Antenna will
remain unchanged
Sector 3

Sector 2

Sector 1

Div Rx Tx/Rx

Div Rx Tx/Rx

Div Rx Tx/Rx

Rx Out

Rx Out

Rx Out

1Rel99 Carrier + 2 HSDPA carriers


consecutive
Upgradable to 4+4+4 @84Mbps with 4
consecutive carriers
25

Nokia Siemens Networks

Presentation / Author / Date

Part 2: 3G Multiradio Configuration


Site configuration WCDMA
FSME+2x FRGP. FTIB or FTPB or FTFA/B

1+1+1/2+2+2

2+2+2/3+3+3/4+4+4
BTS Rx Signal Level must be smaller than -102dBm during
commissioning
26

Nokia Siemens Networks

Presentation / Author / Date

Part 2 : 3G Multi Radio


MRC to be removed from existing

No MRC to be used with Flexi Multi Radio

27

Nokia Siemens Networks

Presentation / Author / Date

Part 3: LTE Site Configuration Model


The LTE configuration : 1+1+1 LTE, 2x2
MIMO @2300 MHz

Optical cable
DC cable

28

Nokia Siemens Networks

Presentation / Author / Date

Part 3: LTE Flexi Multi Radio configuration

29

Nokia Siemens Networks

Presentation / Author / Date

Part 3: LTE Multi Radio Configuration

30

Nokia Siemens Networks

Presentation / Author / Date

ONE BTS type for all Technologies


1+1+1 LTE, 2x2 MIMO
@ 2300MHz TDD

3+3+3 WCDMA @2100MHz


Flexi 3G/LTE System Module

6+6+6 , 4+4+4 TRX


Flexi EDGE System Module

31

Nokia Siemens Networks

Presentation / Author / Date

Power consumptions

32

Nokia Siemens Networks

Presentation / Author / Date

Clock Synchronization
Timing over packet for 2G BTS (Not Co-located with 3G Node-B)
The RAN synchronization is based on Timing Over Packet following standard IEEE 1588.
One ToP master clock can synchronize up between 800 NE.
The ToP will be connected to CE Router as 1+1 ( Active and Standby ) as shown below.

The O&M connectivity for ToP as below.


The Symmetricom O&M connectivity will be a single connection to COMIS router as hardware limitation.

33

Nokia Siemens Networks

Presentation / Author / Date

Clock Synchronization
Timing over packet for 2G BTS (Co-located with 3G NodeB)
Synchornization to other system modules can also be done based on IEEE1588-2008, provided other
system modules support IEEE1588-2008 slave functionality. ToP Engineering rule should be taken into
account.

1. Current 2G GSM - through PCM E1


2. 3G WCDMA Timing over Packet
(TOP)
3. LTE - GPS
34

Nokia Siemens Networks

Presentation / Author / Date

2G/3G Modernization
GSM
1. Existing Dump to be used as a reference
2. Existing Physical site database as a reference
3. 2G Parameter/new frequency plan in case new configuration is needed (for
example TRX upgrade), For 3G Parameter/SC plan in case new configuration is
needed (for example Carrier upgrade)
4. A-bis timeslot mapping generated by the planning team to be followed
5. XML creation to be done in a case the site configuration changed (existing
parameters to be used if no upgrade)
6. the above XML to be sent to CM team for implementation
7. Site integration report received from NI after integration
8. NPO will check the parameter consistencies, health check (alarms), and initial KPI
9. Post modernization Drive test to be done to verify the hardware and swap feeders

10. KPI reports to be submitted to STC optimization for acceptance


11. Site accepted and passed to Managed Services

35

Nokia Siemens Networks

Presentation / Author / Date

2G/3G Modernization ( Swap from Other Vendor)


Final Swap (Cold Swap) :
1.All NSN BTS sites with required E1s and BSCs /RNC are deployed, commissioned and
integrated.
2.All routing plans in the MSC verified and found to be correct.
3.The RF parameters for all swap BTS sites have been matched up with the existing RF
settings in old vendor network, so that the two networks have same RF parameters after swap.
4.Drive test vehicles are available
Activities :
1. Disable old BTS sites by giving commands.
2. Remove all Jumpers from Old BTS by Locking the TRX.
3. Connect the NSN BTS to the Existing Feeder line with new jumpers.
4. Once all six cables are properly connected, Powered on the NSN Flexi Modules.
5. Connect the E1 and check OMU become functional.
6. Unlock the DTRX.
7. Display the status of the BTS at the GNSC, and confirm that all devices are Installed and
Operational.
8. Drive test teams should start the activity after the site is On Air

36

Nokia Siemens Networks

Presentation / Author / Date

2G/3G Modernization ( Swap from Other Vendor)


HOT SWAP :
In case of HOT SWAP installation and commissioning of NSN BTS to be done during the
outage period only.
However following pre-requisites needs to be confirmed:
1. Availability of Manpower and Tools.
2. Installation material availability.
3. Confirmation of site Access during outage time.

37

Nokia Siemens Networks

Presentation / Author / Date

Modernization Fall Back Procedure


2G
1. Save the latest dump

2. Extract the site parameters / configurations by clicking the Backup plan in


NetAct using XML format before deleting the site
3. Save this file
4. During fall back, re-run this XML file to re-create the site
5. Re-create A-bis and ADJx based on the dump
6. The field team must retrieve the old commissioning and A-bis plan

3G

1. There is no parameter change during modernization


2. The same parameters exists in NetAct so only equipment change over
to be done

38

Nokia Siemens Networks

Presentation / Author / Date

Add New LTE


1.
2.
3.
4.
5.
6.

Existing Physical site database as a reference in case of collocation


Parameter planning and creation
XML creation
XML to be sent to CM team for implementation
Site integration report received from NI after site integration
NPO will check the parameter consistencies, health check (alarms), and initial
KPI
7. Drive test to be done to verify the hardware and swap feeders
8. Site locked and to be unlocked for testing purpose
9. KPI reports to be submitted to STC optimization for acceptance
10.Site accepted and passed to Managed Services

39

Nokia Siemens Networks