100W Ku-Band
Mini Compact Outdoor SSPA
Description
The Teledyne Paradise Datacom Mini Compact Outdoor Solid
State Power Amplifier (SSPA) is built for extreme environmental conditions and high reliability operation. Along with the robust construction exists the highest power density in the industry. This allows solid state technology to be used in applications that have long been reserved for TWTAs.
Gallium Nitride amplifiers offer considerably better performance
than conventional GaAs solutions. GaN offers better efficiency
than other conventional amplifier technologies and also
exhibits exceptional gain and power over frequency.
Weighing less than 24.5 lbs. (11.2 kg), and 19.6 lbs. (8.9 kg)
for Ku-Band units, and only slightly larger than a lunch box, this
family of GaN SSPAs is available in the following output power
levels:
C-Band: 50W, 80W, 100W, 150W, 200W
X-Band: 50W, 80W, 100W, 150W, 200W
Ku-Band: 40W, 50W, 80W, 100W
Teledyne Paradise Datacom LLC
328 Innovation Blvd., Suite 100
State College, PA 16803 USA
Tel: 1 (814) 238-3450
Fax: 1 (814) 238-3829
1 OF 8
www.paradisedata.com
OPTIONS
SPECIFICATIONS
Output Power
Typical, Psat
Guaranteed minimum, PLinear 1
Power Requirements
Line Voltage
Line Frequency
Line Power (typical)
NOTES
LIMITS
UNITS
Frequency selection L
Frequency selection H
Frequency selection C
Frequency selection A
Frequency selection B
Frequency selection D
4.400 to 5.000
5.715 to 5.790
5.750 to 6.670
5.850 to 6.425
5.850 to 6.725
6.425 to 7.025
GHz
GHz
GHz
GHz
GHz
GHz
HPAC3050AC_XXXXG
HPAC3080AC_XXXXG
HPAC3100AC_XXXXG
HPAC3150AC_XXXXG
HPAC3200AC_XXXXG
Psat / PLinear
47.0 (50) / 44.0 (25)
49.0 (80) / 46.0 (40)
50.0 (100) / 47.0 (50)
52.0 (158) / 49.0 (80)
53.0 (200) / 50.0 (100)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
HPAC3050AC_XXXXG
HPAC3080AC_XXXXG
HPAC3100AC_XXXXG
HPAC3150AC_XXXXG
HPAC3200AC_XXXXG
90 to 265
47 to 63
Psat / PLinear
500 / 425
590 / 470
630 / 500
1030 / 820
1100 / 880
Tx Band
Rx Band
-75
-150
dBW/4 KHz
dBW/4 KHz
W
W
W
W
W
Note 1: PLinear = maxiumum output power at which third order internal products = -25 dBc.
Output Power
Typical, Psat
Guaranteed minimum, PLinear 1
Power Requirements
Line Voltage
Line Frequency
Line Power (typical)
NOTES
LIMITS
UNITS
Frequency selection F
Frequency selection D
Frequency selection A
7.10 to 7.40
7.70 to 8.40
7.90 to 8.40
GHz
GHz
GHz
HPAX3050AC_XXXXG
HPAX3080AC_XXXXG
HPAX3100AC_XXXXG
HPAX3150AC_XXXXG
HPAX3200AC_XXXXG
Psat / PLinear
47.0 (50) / 44.0 (25)
49.0 (80) / 46.0 (40)
50.0 (100) / 47.0 (50)
52.0 (158) / 49.0 (80)
53.0 (200) / 50.0 (100)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
HPAX3050AC_XXXXG
HPAX3080AC_XXXXG
HPAX3100AC_XXXXG
HPAX3150AC_XXXXG
HPAX3200AC_XXXXG
90 to 265
47 to 63
Psat / PLinear
520 / 440
610 / 490
650 / 520
1050 / 840
1120 / 900
VAC
Hz
W
W
W
W
W
Insertion Loss
-0.35
dB
Tx Band
-75
dBW/4 kHz
-85
-150
dBW/4 KHz
dBW/4 KHz
Note 1: PLinear = maxiumum output power at which third order internal products = -25 dBc.
2 OF 8
Output Power
Typical, Psat
Guaranteed minimum, PLinear 1
Power Requirements
Line Voltage
Line Frequency
Line Power (typical)
NOTES
LIMITS
UNITS
Frequency selection F
Frequency selection B
Frequency selection A
Frequency selection C
Frequency selection D
12.75 to 13.25
13.75 to 14.50
14.00 to 14.50
14.50 to 14.70
15.10 to 15.40
GHz
GHz
GHz
GHz
GHz
HPAK3040AC_XXXXG
HPAK3050AC_XXXXG
HPAK3080AC_XXXXG
HPAK3100AC_XXXXG
Psat / PLinear
46.0 (40) / 43.0 (20)
47.0 (50) / 44.0 (25)
49.0 (80) / 46.0 (40)
50.0 (100) / 47.0 (50)
dBm (W)
dBm (W)
dBm (W)
dBm (W)
HPAK3040AC_XXXXG
HPAK3050AC_XXXXG
HPAK3080AC_XXXXG
HPAK3100AC_XXXXG
Receive Band Noise Power Density2
90 to 265
47 to 63
Psat / PLinear
480 / 385
510 / 410
730 / 585
780 / 625
VAC
Hz
- 155
dBW / 4 KHz
W
W
W
W
Note 1: PLinear = maxiumum output power at which third order internal products = -25 dBc.
Note 2: All Ku-Band SSPAs are fitted with a receive band reject bulkhead filter, standard. An optional pressure window is available.
3 OF 8
NOTES
LIMITS
UNITS
range
full band (C-, X-, Ku-Band units)
full band (S-Band units)
full band (Extended C-Band, Extended Ku-Band units)
per 40 MHz (C-, X-, Ku-band units)
per 10 MHz (S-Band)
-40 C to +55 C
0.1 dB resolution
55-75
1.0
0.75
1.5
0.3
0.3
1.5
20
dB
dB
dB
dB
dB/40 MHz
dB/10 MHz
dB
dB
-25
AM/PM Conversion
@ rated PLinear
1.0
Spurious
Harmonics (SSPA only)
@ rated PLinear
@ rated PLinear
-65
-50
1.30:1
1.50:1
Input/Output VSWR
Noise Figure
dBc
o
/dB
dBc
dBc
10
dB
Group Delay
(per 40 MHz segment)
Linear
Parabolic
Ripple
0.01
0.003
1.0
ns/MHz
ns/MHz2
ns p-p
TX Band
-75
dBW/4 KHz
-110
-120
-130
-135
-140
-140
-140
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
-90
-100
-110
-120
-125
-130
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
Range
Accuracy
dB
dBm
4 OF 8
Frequency Band
IF Input
LO Frequency
RF Output
Gain Change
Standard C-Band
4.900 GHz
0-4 dB
Extended C-Band
4.900 GHz
0-4 dB
Standard X-Band
6.950 GHz
0-2 dB
Ku
Ku-Band Sub-Band A
13.050 GHz
0-2 dB
Ku
Ku-Band Sub-Band B
12.800 GHz
0-2 dB
Ku
Ku-Band Sub-Band F
11.800 GHz
0-2 dB
Spurious
NOTES
LIMITS
UNITS
Nominal setting
full band (C-, X-, Ku-bands)
full band (Extended C-, Ku-bands)
per 40 MHz (C-, X-, Ku-bands)
75
2.0
2.5
0.5
20
55 - 75
1.5
dB
dB
dB
dB/40 MHz
dB
dB
dB
Absolute max.
-30
-60
-70
-80
-90
-90
C-band (typ.)
-60
-80
-80
-85
-120
-125
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
-50
-40
-50
-30
dBc
dBc
dBc
dBm
dB
Noise Figure
At 75 dB gain setting
20
Input VSWR
L-Band
1.5 : 1
Reference accuracy @ 25 C
Reference Stability over Temperature (-20 to +85 C)
1 10-8
3 10-8
5 OF 8
RF OUT
J2
M&C
J4
RF OUT
J2
SSPA
STATUS
LINK
J5
RF IN
J1
SWITCH
J6
MODEL: XXXXXXXXXXXX
S/N: XXXX
J8
AUX
PWR
SAMPLE
J3
AC IN
J7
P/N: LXXXXXX-X
NOTES
LIMITS
UNITS/DETAILS
inches
mm
24.5 (11.2)
19.6 (8.9)
lbs. (kg)
lbs. (kg)
Paint
RF Input
RF Output - Ku-Band
RF Output - C-Band
RF Output - X-Band
RF Output Sample
Line Power
Monitor and Control
Link Port
Redundancy Switch Port
Auxiliary +15VDC LNB Power (500 mA)
Type N
WR75 Waveguide
WR137 Waveguide
WR112 Waveguide
Type N
3-pin MS-type
32-pin MS-type
6-pin MS type
6-pin MS-type
8-pin MS-type
Female
Grooved flange (PBR-120)
CPR137G flange (PDR-70)
CPR112G flange (PDR-84)
Female
Plug
Socket
Socket
Socket
Socket
Ambient
-40 to +60
Finish
Connectors
Operating Temperature
Relative Humidity
Condensing
100
100
CFM
IP54
Audible Noise
69
Cooling System
Altitude
Shock
Vibration
6 OF 8
dBA
The RCP2-1000-MINI is a Remote Control Panel for the Mini Compact Outdoor SSPA. It
requires 1RU of cabinet space and provides a similar local interface as exists on Teledyne
Paradise Datacom Indoor Rack Mount amplifiers. Reference specification sheet 209728.
The controller communicates with the outdoor amplifier via a RS485 link. The controller then
provides a wide range of interface capability including Ethernet communications. The following communication links are available at the Remote Control Panel:
The Universal Handheld Controller (RCH-1000) is a versatile device used to interface with a
variety of Teledyne Paradise Datacom amplifiers, including Compact Outdoor SSPA, Mini
Compact Outdoor SSPA, or H-Series High Power Outdoor SSPA. Reference specification
sheet 211667.
The device is housed in a ruggedized
enclosure that is environmentally sealed to
IP65 levels. This allows the Universal
Handheld Controller (RCH-1000) to be used
in most outdoor environments. The rugged
construction of the device enclosure provides
protection from impact and vibration.
This device allows the operator to adjust the attenuation of the connected unit, and control the
mute/unmute selection, as well as monitor the status, conditions and settings of the connected unit via a serial RS-485 connection. Fault conditions and other events are tracked in the
controllers internal log.
7 OF 8
X X
G
GaN Designator
Band
G = GaN Device
C = C-Band
X = X-Band
K = Ku-Band
Configuration Modifier 3
X = Standard
A = Side Mount AC Input
D = 48 VDC Input
F = Side Mount 48 VDC Input
Configuration Modifier 2
X = Standard
M = MS-Connector Covers
R1 = Receive Band Reject Filter
U1 = MS-Connector Covers &
Transmit Band Filter
1
X-Band only.
Configuration Modifier 1
X = Standard
System Configuration
X = Standalone
Block Up Converter
A = None (RF Input)
M = Internal Reference BUC
P = External Reference BUC
Package
C = Standard Mini Compact Outdoor
Example: A standalone 80W Standard Ku-Band Mini Compact Outdoor unit with an optional
internal reference BUC and MS-Connector covers is part number: HPAK3080ACMXXMXG