TRUEPOINT 6500

FACTORY ACCEPTANCE
TEST PROCEDURE

IMN-907006-E02

Factory Acceptance Test


Procedure

Factory Acceptance Test Procedure


IMN-907006-E02 Rev 03 APRIL 2010
This manual incorporates features and functions provided with the TRuepoint 6500 series radio equipment.

Copyright 2010 by Aviat Networks, Inc.


All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval
system, or translated into any language or computer language, in any form or by any means, electronic, magnetic,
optical, chemical, manual or otherwise, without the prior written permission of Aviat Networks Inc. To request
permission, contact techpubs@aviatnet.com.

Warranty
Aviat Networks makes no representation or warranties with respect to the contents hereof and specifically
disclaims any implied warranties or merchantability or fitness for any particular purpose. Further, Aviat Networks
reserves the right to revise this publication and to make changes from time to time in the content hereof without
obligation of Aviat Networks to notify any person of such revision or changes.

Safety Recommendations
The following safety recommendations must be considered to avoid injuries to persons and/or damage to the
equipment:
1.

Installation and Service Personnel: Installation and service must be carried out by authorized personnel who
have the technical training and experience necessary to be aware of any hazardous operations during
installation and service, and of measures to avoid any danger to themselves, to any other personnel, and to the
equipment.

2.

Access to the Equipment: Access to the equipment in use must be restricted to service personnel only.

3.

Safety Norms: Local safety regulations must be used if mandatory. Safety instructions in this document should
be used in addition to the local safety regulations. In the case of conflict between safety instructions stated in
this manual and those indicated in local regulations, mandatory local norms will prevail.

4.

Service Personnel Skill: Service personnel must have received adequate technical training on
telecommunications and in particular on the equipment this manual refers to.

Trademarks
All trademarks are the property of their respective owners.

ii

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Contact Information
Sales and Sales Support:
For sales information, contact one of the Aviat Networks headquarters, or find your regional sales office at http://
www.aviatnetworks.com/contact-us/sales/.
Corporate Headquarters
North Carolina, USA

International Headquarters
Singapore

Aviat Networks, Inc.

Aviat Networks (S) Pte. Ltd.

Research Triangle Park

17, Changi Business Park Central 1

637 Davis Drive

Honeywell Building, #04-01

Morrisville, North Carolina 27560

Singapore 486073

United States
Phone: + 1 919-767-3230

Phone: +65 6496 0900

Fax: + 1 919-767-3233

Fax: + 65 6496 0999

Customer Service:
For customer service, contact one of the regional Technical Help Desks listed below.
Americas Technical Help
Desk

EMEA Technical Help Desk

Asia Pacific Technical Help


Desk

Phone:+1 210 561 7400


Toll-free in Canada/US:
+1 800 227 8332
Fax: +1 210 561 7399

Phone:+44 1698 714 073

Phone:+63 45 599 5192

Fax: +44 1698 717 204

Fax: +63 45 599 5196

TAC.AM@aviatnet.com

TAC.EMEA@aviatnet.com

TAC.APAC@aviatnet.com

Or you can contact your local Aviat Networks office. Contact information is available on our website at:
www.aviatnetworks.com/contact-us/locations-worldwide/.

IMN-907006-E02 REV 03 APRIL 2010

iii

Product Compliance Notes


TRuepoint 6500 is a Class A product. In a domestic environment this product may cause interference in which
case the user may be required to take adequate measures. This equipment is intended to be used exclusively in
telecommunications centers.
TRuepoint 6500 is a point-to-point SDH digital transmission system, intended for use in
telecommunication networks.
For details of where the equipment is intended to be used, refer to the country matrix below. It
should be noted that a licence to operate this apparatus is likely to be necessary and the
appropriate regulatory administration should be contacted.
Aviat Networks intends to market this equipment where a cross (X) is shown.
Note:
The information contained in this document has been gathered from the relevant government authorities
and relates only to European countries participating in the R&TTE Directive.

X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X

Switzerland

X
X
X
X
X
X

X
X
X
X
X
X

United Kingdom

X
X

X
X
X
X
X
X

X
X

Spain

X
X
X
X
X
X

X
X

Sweden

X
X

X
X X
X X

X
X
X

X
X

X
X

X
X

X
X

X
X
X

X
X
X

X
X

Slovenia

X
X
X
X
X
X

Romania

X
X
X
X

X
X

Slovak Republic

X
X
X

Poland

Portugal

X X
X X

Norway

X X
X X
X X
X X
X
X X

Malta

X
X
X
X

X X
X X

Netherlands

X X
X X

Lithuania

X
X

Luxembourg

X
X

Italy

X
X

Latvia

Iceland

X X
X X

Ireland

Greece

Hungary

X
X

France

Germany

X
X
X
X
X
X

X
X

Finland

X
X
X
X

X
X
X
X
X
X
X
X
X

Estonia

X
X

Denmark

Cyprus

X
X

X
X

Czech Republic

X
X
X

Bulgaria

Austria

Belgium

4GHz (3,600 - 4,000MHz)


X
U4GHz (3,803.5 - 4,203.5MHz) X
5GHz (4,400 - 5,000MHz)
L6GHz ( 5,925 - 6,175MHz)
X
U6GHz (6,430 - 7,100MHz)
X
7GHz (7,125 - 7,725MHz)
X
8GHz (7,725 - 8,275MHz)
11GHz (10,700 - 11,700MHz)
13GHz (12,750 - 13,250MHz) X

X
X
X
X
X
X
X
X

X
X
X
X
X
X

X
X
X
X
X

European Union WEEE Directive


In accordance with the WEEE Directive (2002/96/EC), TRuepoint 6500 is marked with the following symbol:

This symbol indicates that this equipment should be collected separately for the purposes of recovery and/or
recycling. For information about collection and recycling of Aviat Networks see www.aviatnetworks.com/
products/compliance/weee/ or contact your local Aviat Networks sales office. If you purchased your
product via a distributor please contact the distributor for information regarding collection and recovery/recycling.
(WEEE is the acronym for Waste electrical and electronic equipment.)

European Union RoHS Directive


The RoHS Directive (2002/95/EC) was implemented on 1 July, 2006. TRuepoint 6500 meets the requirements of this
directive.

iv

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

RoHS Compliance: China


TRuepoint 6500 is compliant with Chinas RoHS requirements and in compliance with legislation introduced in
March 2007. All products display the date of manufacture.
Material Disclosure Table of Hazardous Substances or Element

IMN-907006-E02 REV 03 APRIL 2010

vi

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Declaration of Conformity, R&TTE Directive, 1999/5/EC

IMN-907006-E02 REV 03 APRIL 2010

vii

WARNING
Making adjustments and/or modifications to this equipment that are not in
accordance with the provisions of this instruction manual or other
supplementary documentation may result in personal injury or damage to
the equipment, and may void the equipment warranty.

AVERTISSEMENT
Tout rglage ou modification faits cet quipement hors du cadre dict
par ce guide dutilisation ou par toute autre documentation supplmentaire
pourraient causer des blessures ou endommager lquipement et peut
entraner lannulation de sa garantie.

WARNUNG
Die an diesen Gerten gemachte Einstellungen und/oder nderungen,
welche nicht gem dieser Bedienungsanleitung, oder gem anderen
zustzlichen Anleitungen, ausgefhrt werden, knnen Verletzungen oder
Materialschden zur Folge haben und eventuell die Garantie ungltig
machen.

ATENCIN
Llevar a cabo ajustamientos y/o modificaciones a este equipo, sin seguir
las instrucciones provistas por este manual u otro documento adicional,
podra resultar en lesiones a su persona o daos al equipo, y anular la
garanta de este ltimo.

viii

AVIAT NETWORKS

Table of Contents
FACTORY ACCEPTANCE TEST PROCEDURE

Factory Acceptance Test Items .............................................................................................................1


Related Manuals ...................................................................................................................................1
Test Instruments ...................................................................................................................................2
Factory Acceptance Test Procedure .....................................................................................................5
Transmitter Output Power Test ......................................................................................................5
Transmitter Spurious ......................................................................................................................7
Transmitter Local Frequency Test................................................................................................10
IF-IF Characteristics......................................................................................................................22
BER Characteristics Test ..............................................................................................................26
Baseband output waveform...........................................................................................................28
Radio Protection Switching (RPS) Test .........................................................................................30
Orderwire (OW) Transmission Test ...............................................................................................32
Housekeeping function test...........................................................................................................33
Rack Alarm Bus Function..............................................................................................................36
Visual inspection............................................................................................................................37
Stability Test of STM-1 Signal .......................................................................................................38

IMN-907006-E02 REV 03 APRIL 2010

ix

TABLE OF CONTENTS

AVIAT NETWORKS

Factory Acceptance Test


Procedure
Factory Acceptance Test Items
1.

Transmitter Output Power

2. Transmitter Spurious
3. Transmitter Local Frequency
4. IF-IF Characteristics
5. BER Characteristics
6. Baseband Output Waveform
7. Radio Protection Switching (RPS)
8. Orderwire (OW) Function
9. Housekeeping (HK) Function
10. Rack Alarm Bus Function
11. Visual Inspection
12. Stability test of STM-1 Signal
NOTE:
Unless otherwise specified, all specifications are defined by the
latest R&TTE requirement, Directive 1999/5/EC.

Related Manuals
TRuepoint 6500 Instruction Manual, IMN-907002-Exx
TRuepoint 6500 Installation & Maintenance Manual, IMN-907003-Exx
TRuepoint 6500 User Interface Manual, IMN-907004-Exx
TRuepoint 6500 Test Procedure, IMN-907005-Exx

IMN-907006-E02 REV 03 APRIL 2010

Test Instruments
Table 1-1 shows the test instruments necessary for performing the factory
acceptance test.
Legend For Table 1-1
Fa = Factory
OF = Occasionally Field
Fd = Field
L = Laboratory & Factory Certification
T = Troubleshooting
C = Commissioning & Installation
Table 1-1. Test Instrumentst

Item
#

Descrip.

Factory Selection

Key Specs.

Alternative
Manuft.

Loc.

App.

Fa &
OF

L, T

Manuft.

Model #

Signal
Generator

Agilent

AT8648B

100 KHz - 1
GHz, +10 to
-136 dBm
for
Reference
Signal

Power
meter with
sensor

Agilent

EPM-442A /
8481A /
8481D

+10 dBm,
Cover radio
operating
frequency, 4
- 13 GHz, as
required for
Tx Power
Output

Agilent

EPM-442A /
8481A /
8481D

Fa &
Fd

L, T

Frequency
counter

Advantest

R5372

Cover radio
operating
frequency, 4
- 13 GHz, as
required for
Tx & Rx
Frequency
Verification

Agilent

53181A

Fa &
Fd

C,
L, T

Noise Level
Meter

Anritsu

ML424A

100 Hz to 13
MHz, RMS
Detection for
64 Kbit/s
BER &
Continuity

Fa &
OF

L, T

Microwave
link
analyzer
(70MHz)

Anritsu

ME453M

Group Delay
and Phase

Fa &
OF

L, T

None

Model #

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Item
#

Descrip.

Factory Selection

Key Specs.

Alternative
Manuft.

Loc.

App.

Fa &
OF

L, T

Manuft.

Model #

Model #

PCM
Channel
Analyzer

Anritsu

MS371A1

64 Kbit/s &
Continuity

SDH STM-1
analyzer

Anritsu

MP1570A

ITU-T G.703
& G.957
Interface
and G.783
Format
Standards

Digital
Lightwave
or Sunrise
SDH

622M-A1B1
or
SSSDHC-STM
16J w/
SSTM-1-13IR
&
SSDHCJ-SCSM

Fa &
OF

C,
L, T

Spectrum
analyzer

Agilent

HP8565F

Cover radio
operating
frequency, 4
- 13 GHz, as
required for
TX Output
Spectrum
verification

Agilent

HP8563EC

Fa &
OF

L, T

Oscilloscope

Lecroy

Waverunner
6100A

Dual Trace,
2 GHz for
DADE & XPIC

Agilent or
Tektronix

Fa &
OF

L, T

10

Digital
Multi-meter

Fluke

175

DC Volts,
100 VDC for
Power
Supply, RSL/
Antenna
Alignment

Fa &
Fd

C,
L, T

11

Fixed
attenuator
(30 dB)

SMA
connectors,
30 dB, Cover
radio
operating
frequency, 4
- 13 GHz, as
required for
RSL,
Protection
Switching &
ATPS Setup

Agilent

11708A

Fa &
Fd

C,
L, T

12

Variable RF
attenuator
(0 to 80 dB)

SMA
connectors,
30 dB, Cover
radio
operating
frequency, 4
- 13 GHz, as
required

Agilent

G382A - 3,95
-5.84GHz

Fa &
Fd

C,
L, T

J382A - 5.3
-8.2GHz
H382A 7-10GHz
X382A - 8,2
-12.4GHz
P382A - 12.4
-18GHz

IMN-907006-E02 REV 03 APRIL 2010

Item
#

Descrip.

13

Variable RF
attenuator
Adapters (0
to 80 dB)

Factory Selection
Manuft.

Key Specs.

Model #

Alternative
Manuft.

Model #

Agilent

G281A - 3,95
-5.84GHz

Loc.

App.

Fa &
Fd

C,
L, T

Fa &
Fd

C,
L, T

J281A - 5.3
-8.2GHz
H281A 7-10GHz
X281C
opt013 - 8,2
-12.4GHz
P281C - 12.4
-18GHz
7-mm only

14

PC (for
WebLT
operation)

Any

e/w 10 or
100BT,
Microsoft
Internet
Explorer 6.0
or above

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Factory Acceptance Test Procedure


Transmitter Output Power Test
Test Type:
Station test
Test Objective:
To confirm that the output power of MSTU is within the
limit
Specifications:
TX output power:
+29 dBm or +32 dBm0.5 dB (ATPC: HIGH), +19 dBm
or +22 dBm0.5 dB (ATPC: LOW)
(+29/+19 dBm: Standard power model, +32/+22 dBm: High power model)
+ 29 dBm (ATPC: HIGH)/ +19 dBm (ATPC: LOW) for 11 GHz
+27 dBm (ATPC: HIGH)/ +17 dBm (ATPC: LOW) for 13 GHz
Measured at TX port on MSTU with modulated power.
Test instruments required:
Power meter with sensor (EPM-442A+8481A or equivalent)
Fixed attenuator (30 dB) or equivalent.
PC (for WebLT)
Test set-up:
Set up the test circuit as shown in Figure 1-1
Figure 1-1. Transmitter Output Power Measurement
ADPT

Power
Sensor

RF
Attenuator

Power
Meter

S MA Coaxial Connector

TX

RX

SD

TX port: Transmi tter output


RX: port: Main RX inp ut
SD p ort: S D RX input

MSTU Ada ptor

IMN-907006-E02 REV 03 APRIL 2010

TX Output Power Measurement Procedure:


1.

Turn off the circuit power breaker on MSTU.

2. Remove the TX OUT cable.


3. Connect power meter to the SMA connector marked with TX.
If the maximum range of the power meter is less than the rated output power level
of MSTU, insert fixed and calibrated attenuator between the TX output and the
power meter.
4. Turn on the circuit power breaker on MSTU.
5. Set the TX output power to HIGH.
6. Read the power meter indication.
7. Set the TX output power to LOW.
8. Read the power meter indication.
NOTE:
TX output power is specified at the MSTU output port, and the
measured value at the MSTU Adapter should be converted by the
following equation.
TX output power = Measured value + MSTU Adapter loss
Table 1-2. MSTU Adapter Loss for Calculation

Frequency Band (GHz)

TX (dB)

RX (dB)

SD RX (dB)

4G Type 1 (4G)

0.4

0.55

0.6

4G Type 2 (U4G)

0.4

0.55

0.6

5G Type 1 (5G)

0.45

0.65

0.7

L6G Type 1 (L6G)

0.55

0.75

0.8

U6G Type 1 (U6G)

0.55

0.8

0.85

7G Type 1/2 (L7G)

0.6

0.85

0.9

7G Type 5/7 (U7G)

0.65

0.85

0.95

7G Type 4 (W7G)

0.65

0.85

0.9

7G Type 8 (M7G)

0.6

0.85

0.9

8G Type 1 (L8G)

0.7

0.9

0.95

8G Type 2 (K8G)

0.7

0.9

0.95

11G Type 1/2 (11G)

0.8

1.1

13G Type 1 (13G)

0.82

1.18

1.25

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Transmitter Spurious
Test Type:
Test Objective:
limit.
Specifications:

Station test
To confirm that the TX output spurious is within the

Frequency Band

Frequency Range

Specification

Out of Band

30 MHz - 21.2 GHz

-60 dBm

21.2 GHz - 40 GHz

-30 dBm

TX side half band

-60 dBm

RX side half band

-90 dBm2

In band

1. ft +/- 100 MHz is not included. (ft is the MSTU transmission frequency.)
2. This specification is described in the current TR6500 data format while
this value is not specified in the latest R&TTE requirement. This value is
not measured in the actual TR6500 factory testing at present. However,
this value is guaranteed at the design verification level.

Test instruments Required:


Spectrum analyzer (HP8565F or equivalent)
Fixed attenuator (30 dB)
PC (for WebLT)
Test set-up:
Set up the test circuit as shown in Figure 1-2

IMN-907006-E02 REV 03 APRIL 2010

Figure 1-2. Transmitter Spurious Measurement set up

SD
RX
TX

DUP

ADP T

DUP

A DP T

BPF
BPF
BPF

BPF
BPF
BPF

BPF
BPF
BPF

BPF
BPF
BPF

Variable
RF

MSTU (M7)

MSTU(M6 )

MS TU (M5 )

MSTU (M4)

MSTU(M3 )

MS TU (M2 )

MSTU (M1)

MSTU(PR T)

HK2
HK1
OCC I NTF
BS W(M 7)
B SW(M6)
BSW(M5)
BS W(M 4)
B SW(M3)
BSW(M2)
BS W(M 1)
TCU Y
TCU X

SV
EC U1
EC U2

NF B

C on ne cto rs

TERM

Reference Point A
Spectrum Analyzer

Power
Meter
Power Sensor

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Test Procedure
1.

Turn off all circuit power breakers on MSTU.

2. Connect the spectrum analyzer to the duplexer (DUP) output port through the
30-dB high power fixed RF attenuator.
3. Turn on the circuit power breaker of MSTU to be measured.
4. Set the transmitter output signal to CW (Carrier Wave) to stop modulation with
WebLT.
5. Set the RF level of the Reference Point A to 0dBm with the variable attenuator.
6. Set the 0dBm reference line to the upper part of the spectrum analyzer.
7. Check the level of spurious displayed on the screen of the spectrum analyzer.
8. Restore the connections.
Figure 1-3. Spectrum analyzer screen

IMN-907006-E02 REV 03 APRIL 2010

Transmitter Local Frequency Test


Test Type:
Station test
Test Objective:
To ensure the TX local carrier frequency at TX LO MON
on MSTU
Specifications:
Tolerance: Within 10 ppm
Tolerable frequency deviation is shown in Table 1-8.
Test instrument required:
Frequency counter (R5372 or equivalent)
Test set-up:
Set up the test circuit as shown in Figure 1-4.
Figure 1-4. Transmitter Local Frequency measurement

Frequency
Counter

10

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Test Procedure
1.

Preparation for measurement


a.

Warm up the frequency counter at least 30 minutes before measurement.

b.

The BAND SELECT SW on the frequency counter shall be set to the


appropriate RF frequency range.

2. Set up the test circuit as shown in Figure 1-4.


3. Record the Transmit Local frequency and calculate its tolerance using the following
formula.
Tolerance (kHz) = (Measured frequency - Specified TX LO frequency)
4. Compare the results with the following tables.

Tolerable Frequency Deviation for Specified RF bands (64QAM)


Table 1-3. 4 GHz Type 1 (4G), 64QAM - 155.52 Mbps System
RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

3620

2776

27.76

3660

2816

28.16

3700

2856

28.56

3740

2896

28.96

3780

2936

29.36

3820

2976

29.76

3860

3016

30.16

3940

3096

30.96

3980

3136

31.36

4020

3176

31.76

4060

3216

32.16

4100

3256

32.56

4140

3896

32.96

4180

3336

33.36

Table 1-4. 5 GHz Type 1 (5G), 64QAM - 155.52 Mbps System


RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

4430

3586

35.86

4470

3626

36.26

4510

3666

36.66

4550

3706

37.06

4590

3746

37.46

IMN-907006-E02 REV 03 APRIL 2010

11

RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

4630

3786

37.86

4670

3826

38.26

4730

3886

38.86

4770

3926

39.26

4810

3966

39.66

4850

4006

40.06

4890

4046

40.46

4930

4086

40.86

4970

4126

41.26

Table 1-5. U6 GHz Type 1 (U6G), 64QAM - 155.52 Mbps System

12

RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

6460

5616

56.16

6500

5656

56.56

6540

5696

56.96

6580

5736

57.36

6620

5776

57.76

6660

5816

58.16

6700

5856

58.56

6740

5896

58.96

6800

5956

59.56

6840

5996

59.96

6880

6036

60.36

6920

6076

60.76

6960

6116

61.16

7000

6156

61.56

7040

6196

61.96

7080

6236

62.36

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Table 1-6. 11 GHz Type 1 (11G), 64QAM - 155.52 Mbps

System(Recommends 1.1 Main pattern)

RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

10,715

9871

98.71

10,755

9911

99.11

10,795

9951

99.51

10,835

9991

99.91

10,875

10,031

100.31

10,915

10,071

100.71

10,955

10,111

101.11

10,995

10,151

101.51

11,035

10,191

101.91

10

11,075

10,231

102.31

11

11,115

10,271

102.71

12

11,155

10,311

103.11

11,245

10,401

104.01

11,285

10,441

104.41

11,325

10,481

104.81

11,365

10,521

105.21

11,405

10,561

105.61

11,445

10,601

106.01

11,485

10,641

106.41

11,525

10,681

106.81

11,565

10,721

107.21

10

11,605

10,761

107.61

11

11,645

10,801

108.01

12

11,685

10,841

108.41

IMN-907006-E02 REV 03 APRIL 2010

13

Table 1-7. 11 GHz Type 2 (11G A2), 64QAM - 155.52 Mbps

System(Recommends 1.2 Second option)

14

RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

10,735

9891

98.91

10,775

9931

99.31

10,815

9971

99.71

10,855

10,011

100.11

10,895

10,051

100.51

10,935

10,091

100.91

10,975

10,131

101.31

11,015

10,171

101.71

11,055

10,211

102.11

10

11,095

10,251

102.51

11

11,135

10,291

102.91

12

11,155

10,331

103.31

11,225

10,421

104.21

11,265

10,461

104.61

11,305

10,501

105.01

11,345

10,541

105.41

11,385

10,581

105.81

11,425

10,621

106.21

11,465

10,661

106.61

11,505

10,701

107.01

11,545

10,741

107.41

10

11,585

10,781

107.81

11

11,625

10,821

108.21

12

11,665

10,861

108.61

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Tolerable Frequency Deviation for Specified RF bands (128QAM)


Table 1-8. 4 GHz Type 2 (U4G), 128QAM - 155.52 Mbps System
RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

3824.5

2980.5

29.805

3853.5

3009.5

30.095

3882.5

3038.5

30.385

3911.5

3067.5

30.675

3940.5

3096.5

30.965

3969.5

3125.5

31.255

4037.5

3193.5

31.935

4066.5

3222.5

32.225

4095.5

3251.5

32.515

4124.5

3280.5

32.805

4153.5

3309.5

33.095

4182.5

3338.5

33.385

Table 1-9. L6 GHz Type 1 (L6G), 128QAM - 155.52 Mbps System


RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

5945.20

5101.20

51.0120

5974.85

5130.85

51.3085

6004.50

5160.50

51.6050

6034.15

5190.15

51.9015

6063.80

5219.80

52.1980

6093.45

5249.45

52.4945

6123.10

5279.10

52.7910

6152.75

5308.75

53.0875

6197.24

5353.24

53.5324

6226.89

5382.89

53.8289

6256.54

5412.54

54.1254

6286.19

5442.19

54.4219

6315.84

5471.84

54.7184

6345.49

5501.49

55.0149

6375.14

5531.14

55.3114

6404.79

5560.79

55.6079

IMN-907006-E02 REV 03 APRIL 2010

15

Table 1-10. 7 GHz Type 1 (L7G), 128QAM - 155.52 Mbps System


RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

7135

6291

62.91

7163

6319

63.19

7191

6347

63.47

7219

6375

63.75

7247

6403

64.03

7296

6452

64.52

7324

6480

64.80

7352

6508

65.08

7380

6536

65.36

7408

6564

65.64

Table 1-11. 7 GHz Type 2 (L7G), 128QAM - 155.52 Mbps System

16

RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

7142

6298

62.98

7170

6326

63.26

7198

6354

63.54

7226

6382

63.82

7254

6410

64.10

7296

6452

64.52

7324

6480

64.80

7352

6508

65.08

7380

6536

65.36

7408

6564

65.64

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Table 1-12. 7 GHz Type 4 (W7G), 128QAM - 155.52 Mbps System


RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

1l

7121

6277

62.77

2l

7149

6305

63.05

3l

7177

6333

63.33

4l

7205

6361

63.61

5l

7233

6389

63.89

1l

7317

6473

64.73

2l

7345

6501

65.01

3l

7373

6529

65.29

4l

7401

6557

65.57

5l

7429

6585

65.85

1h

7457

6613

66.13

2h

7485

6641

66.41

3h

7513

6669

66.69

4h

7541

6697

66.97

5h

7569

6725

67.25

1h

7625

6781

67.81

2h

7653

6809

68.09

3h

7681

6837

68.37

4h

7709

6865

68.65

5h

7737

6893

68.93

IMN-907006-E02 REV 03 APRIL 2010

17

Table 1-13. 7 GHz Type 5 (U7G), 128QAM - 155.52 Mbps System


RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

7442

6598

65.98

7470

6626

66.26

7498

6654

66.54

7526

6682

66.82

7554

6710

67.10

7596

6752

67.52

7624

6780

67.80

7652

6808

68.08

7680

6836

68.36

7708

6864

68.64

Table 1-14. 7 GHz Type 7, 128QAM - 155.52 MBPS System

18

RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

7442

6598

65.98

7470

6626

66.26

7498

6654

66.54

7526

6682

66.82

7554

6710

67.10

7603

6759

67.59

7631

6787

67.87

7659

6815

68.15

7687

6843

68.43

7715

6871

68.71

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Table 1-15. 7 GHz Type 8 (M7G), 128QAM - 155.52 Mbps System


RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

7267

6423

64.23

7295

6451

64.51

7323

6479

64.79

7351

6507

65.07

7379

6535

65.35

7428

6584

65.84

7456

6612

66.12

7484

6640

66.40

7512

6668

66.68

7540

6696

66.96

Table 1-16. 8 GHz Type 1 (L8G), 128QAM - 155.52 Mbps System


RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

7747.70

6903.70

69.0370

7777.35

6933.35

69.3335

7807.00

6963.00

69.6300

7836.65

6992.65

69.9265

7866.30

7022.30

70.2230

7895.95

7051.95

70.5195

7925.60

7081.60

70.8160

7955.25

7111.23

71.1125

8059.02

7215.02

72.1502

8088.67

7244.67

72.4467

8118.32

7274.32

72.7432

8147.97

7303.97

73.0397

8177.62

7333.62

73.3362

8207.27

7363.27

73.6327

8236.92

7392.92

73.9292

8266.57

7422.57

74.2257

IMN-907006-E02 REV 03 APRIL 2010

19

Table 1-17. 8 GHz Type 2 (K8G), 128QAM - 155.52 Mbps System

20

RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

7926

7082

70.82

7954

7110

71.10

7982

7138

71.38

8010

7166

71.66

8038

7194

71.94

8066

7222

72.22

8094

7250

72.50

8122

7278

72.78

8192

7348

73.48

8220

7376

73.76

8248

7404

74.04

8276

7432

74.32

8304

7460

74.60

8332

7488

74.88

8360

7516

75.16

8388

7544

75.44

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Table 1-18. 13 GHz Type 1 (13G), 128QAM - 155.52 Mbps System


RF CH No.

RF Frequency (MHz)

LO Frequency (MHz)

Tolerance (kHz

12,765

11,921

119.21

12,793

11,949

119.49

12,821

11,977

119.77

12,849

12,005

120.05

12,877

12,033

120.33

12,905

12,061

120.61

12,933

12,089

120.89

12,961

12,117

121.17

13,031

12,187

121.87

13,059

12,215

122.15

13,087

12,243

122.43

13,115

12,271

122.71

13,143

12,299

122.99

13,171

12,327

123.27

13,199

12,355

123.55

13,227

12,383

123.83

IMN-907006-E02 REV 03 APRIL 2010

21

IF-IF Characteristics
Test Type:
Hop test (Diagnostic only)
Test Objective:
This test is intended to measure the IF-IF characteristics
of 64/128 QAM radio equipment.
Test Instruments Required:
Microwave link analyzer (ME435KM or equivalent)
Variable RF attenuator
PC (for WebLT)
Specifications:
IF-IF Amplitude/Group Delay Specifications
Equipment

Amplitude

Group Delay Frequency Range

4G T1/5G T1/U6 T1/11G T1


or T2 64 QAM

< 2.0 dB

< 15 ns

70 MHz +/- 14.0MHz

4G T2/L6 T1/7G T1 or T2/


7G T8/7G T5/8G T1 or T2/
13G T1 128 QAM

< 2.0 dB

< 15 ns

70 MHz +/- 12.0 MHz

Test set-up:

22

See Figure 1-5

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Figure 1-5. IF - IF Test set up

ATT
Variab le RF attenuator

Near END

Far END

70M IN

Microwave
Link Analyzer
(R)

Microwave
Link Analyzer
(T)

XPIC OUT

IMN-907006-E02 REV 03 APRIL 2010

23

Test Procedure
If Space Diversity system is applied, this test should be done for both MN receiver and
SD receiver independently.
1.

Change the status of RSPI to IS-MT (In Service Maintenance state) by WebLT for
both the near-end and far-end station.

2. Remove the SD RX RF input cable.


3. Operate the FMSR (Frequency Measurement) command to the near-end station.
4. Set Microwave Link Analyzer for IF-IF test.
5. Connect OUTPUT of Microwave Link Analyzer to 70M INPUT port on MSTU of the
far-end station.
6. Connect XPIC OUT of MSTU to INPUT of Microwave link analyzer.
7. Set ITEM NO rotary switch on MSTU of near-end station to B.
8. Set RX RF GAIN to adjust MN 70M OUT level to 10 dBm +/-1 dB.
9. Set the RX IF GAIN to adjust XPIC OUT level to 10 dBm +/- 1 dB.
10. Measure the amplitude response characteristics.
11. Measure the group delay characteristics in the same manner.
12. Replace the SD RX RF input cable and remove the MAIN RX RF cable.
13. Measure the amplitude response characteristics and group delay characteristics for
the SD receiver in the same manner.
14. Release the FMSR (Frequency Measurement).
15. Change the status of RSPI to IS (In Service) state by WebLT for both the near-end
and far-end station.
16. Repeat item 1 through item 15 for all RF channels.
Table 1-19. Set up Data for IF-IF Tests
Link Analyzer TX Settings

TR6500 Settings

Baseband Frequency

250 kHz

TX side

ALC

OFF1

Deviation

250 kHz

RX side

AGC

OFF1

Sweep width

14.0 MHz

EPS

OFF1

IF Frequency

70.0 MHz

IF Level

-10.0 dBm

1. These are set by FMSR command automatically.

24

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Figure 1-6. Amplitude and Group Delay Characteristics

SLD MRK: 14.00 MHz


IF:
10 dBm
FM:
250 kHz rms, BF: 250 kHz

Y1

Y2

Marker

Y1: IF AMPL: 0.5 dB/div

IMN-907006-E02 REV 03 APRIL 2010

Marker

Y2: DELAY: 2 ns/div

25

BER Characteristics Test


Test Type:
Hop test
Test Objective:
To measure the BER Characteristics of STM-1 working
channels
Specifications:
For 64 QAM:
BER=10-3 or better at RSL= -74.5dBm
BER=10-6 or better at RSL= -70.5dBm
Note: RSL is 1 dB higher for the 11 GHz band.
For 128 QAM:
BER=10-3 or better at RSL= -72.0dBm
BER=10-6 or better at RSL= -68.0dBm
Note: RSL is 0.5 dB higher for the 8 GHz (L8GHz/K8GHz) band and 2.5 dB higher for
the 13 GHz band.
Test instruments required:
STM-1 analyzer (MP1570A or equivalent)
Power Meter with sensor (EPM-442A+8481D or equivalent
PC (for Web LT)
Test set-up:
Shown in Figure 1-7

Test Procedure
1.

Set up the test circuit as shown in Figure 1-7.

2. Provisioning: IS (In-Service) for all units


3. Calibrate the RF variable attenuator (considering loss of adapter) so as to set the
RSL.
NOTE:
RX receiving power is specified at the MSTU input port, and the
measured value should be converted by the MSTU adaptor loss.
Refer to Table 1-2 for the MSTU adaptor loss.
4. Measure the BER and confirm that the measured BER is met to the specifications.
5. In the case of the measurement of the Protection channel, turn off all circuit
breakers on the Main channels MSTU in order to switch the STM-1 signal path to
the protection channel.
6. In the case of the measurement of the Main channel, turn off the circuit breaker on
the Protection channels MSTU in order to prevent an unexpected switching
operation.

26

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Figure 1-7. BER Test Set-Up


ATT
Variab le RF attenuator

SD
RX
TX

DUP

ADPT

D UP

AD PT

B PF
B PF
B PF

BPF
BPF
BPF

B PF
B PF
B PF

BPF
BPF
BPF

SD
RX
TX

DU P

AD PT

DUP

ADPT

BP F
BP F
BP F

BPF
BPF
BPF

BP F
BP F
BP F

B PF
B PF
B PF

M STU(M7)

MS TU(M6)

MS TU(M 5)

MS TU(M 4)

MST U(M3)

M STU(M2)

MS TU(M1)

MS TU(P RT)

HK2
HK1

BSW( M7 )
BSW(M 6)

OCC INT F

BSW(M 5)
BSW( M4 )
BSW(M 3)

BSW( M2 )
BSW(M 1)
T CU Y
TCU X

H K2
HK1

MST U(M7)

O CC INT F
BSW( M7 )

M STU(M6)

MS TU(M5)

BSW(M 6)
BSW( M5 )
BSW(M 4)

T CU Y
TCU X

BSW(M 3)
BSW( M2 )

BSW(M 1)

MS TU(M 4)

MS TU(M 3)

M ST U(M2)

M STU(M1)

MS TU(PRT)

STM-1 Analyzer

Power
Sensor

Power Meter

STM-1 Analyzer

SV

SV
E CU1
E CU2

NFB

E CU1
E CU2

N FB

Connectors

T ERM

Connectors

TERM

BSW
HK2
HK 1
TCU2
TCU1
OCC INTF
BSW(M7)
B SW(M6)
BSW(M5)
BSW(M4)
B SW(M3)
BS W( M2 )
BSW(M1)

155M
CMI IN

SV
ECU1

SDH
Ana lyzer

155M
CMI OUT

NFB
WS IN

Connectors

TERM

WS OUT
WS IN
WS OUT

IMN-907006-E02 REV 03 APRIL 2010

27

Baseband output waveform


Test Type:
Hop test
Test Objective:
To measure the baseband output waveform of STM-1
working channels
Specifications:
Within the masks mentioned in ITU-T G703.
Test instruments required:
STM-1 analyzer (MP1570A or equivalent)
Oscilloscope (WaveRunner 6100A or equivalent)
Variable RF attenuator
Test set-up:
Shown in Figure 1-8

Test Procedure
1.

Set up the test circuit as shown in Figure 1-8

2. Provisioning: IS (In-Service) for all units


3. Measure the baseband output waveform.

28

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Figure 1-8. Baseband output waveform test set-up


ATT
Variable RF attenuator

SD
RX
TX

DUP

ADPT

D UP

AD PT

B PF
B PF
B PF

BPF
BPF
BPF

B PF
B PF
B PF

BPF
BPF
BPF

SD
RX
TX

AD PT

DUP

ADPT

BP F
BP F
BP F

BPF
BPF
BPF

BP F
BP F
BP F

B PF
B PF
B PF

M STU(M7)

MS TU(M6)

MS TU(M 5)

MS TU(M 4)

MST U(M3)

HK2
HK1

OCC INT F
BSW( M7 )
BSW(M 6)

BSW(M 5)
BSW( M4 )

BSW(M 3)

T CU Y
TCU X

BSW( M2 )
BSW(M 1)

M STU(M2)

MS TU(M1)

H K2
HK1

O CC INT F
BSW( M7 )
BSW(M 6)

BSW( M5 )
BSW(M 4)
BSW(M 3)
BSW( M2 )

T CU Y
TCU X

BSW(M 1)

MS TU(P RT)

MST U(M7)

M STU(M6)

MS TU(M5)

MS TU(M 4)

MS TU(M 3)

M ST U(M2)

M STU(M1)

MS TU(PRT)

SV

DU P

SV

E CU1
E CU2

NFB

Connectors

STM-1 Analyzer

T ERM

E CU1
E CU2

N FB

Connec tors

TERM

Oscilloscop e

BSW
HK2
HK 1
TCU2
TCU1
OCC INTF
BSW(M7)
B SW(M6)
BSW(M5)
BSW(M4)
B SW(M3)
BS W( M2 )
BSW(M1)

155M
CMI IN

SV
ECU1

SDH
Ana lyzer

155M
CMI OUT

NFB
WS I N

Connectors

TERM

WS OUT
WS I N
WS OUT

IMN-907006-E02 REV 03 APRIL 2010

29

Radio Protection Switching (RPS) Test


Test Type:
Hop test
Test Objective:
To check for correct operation of the Radio Protection
Switch function
Specification:
Ensure RPS operation for the corresponding condition as
follows:
1) Automatic changeover and reversion
2) Manual changeover and reversion
Test instruments required:
STM-1 analyzer (MP1570A or equivalent)
Variable RF attenuator (ATT)
PC (for WebLT)
Test set-up:
Shown in Figure 1-9

Test Procedure
1.

Remove the cables of RF IN for MN and SD RX.

2. Insert the variable RF attenuator (ATT) between RF INPUT of MN RX and RF


OUTPUT of RX BPF for BRU.
3. Configure the test set-up as shown in Figure 1-9.
4. Prior to commencement of testing, confirm that the transmission path is error-free
condition. (5 minutes test).
5. Increase the attenuation of the ATT slowly and confirm with WebLT that the radio
protection switching by USW has been completed.
6. Confirm that there is not error in the data measured with SDH Analyzer.
7. Decrease the attenuation of the ATT slowly and confirm with WebLT that the radio
protection switching has been restored.
8. Confirm that there is not error in the data measured with SDH Analyzer.
9. Repeat steps 3 thru 8 for the other Work channels (if fitted).
10. Through WebLT, perform a manual switching by USW for WORK 1.
11. Confirm that there is not error in the data measured with SDH Analyzer.
12. Release the manual switch.
13. Confirm the switch reversion and error free.
14. Repeat steps 10 thru 13 for all Work bearers (if fitted).

30

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Figure 1-9. Radio Protection Switching Test Set-Up


ATT
Variable RF attenuator
SD
RX
TX

DUP

ADPT

D UP

AD PT

B PF
B PF
B PF

BPF
BPF
BPF

B PF
B PF
B PF

BPF
BPF
BPF

SD
RX
TX

DU P

AD PT

DUP

ADPT

BP F
BP F
BP F

BPF
BPF
BPF

BP F
BP F
BP F

B PF
B PF
B PF

M STU(M7)

MS TU(M6)

MS TU(M 5)

MS TU(M 4)

MST U(M3)

M STU(M2)

MS TU(M1)

MS TU(P RT)

MST U(M7)

M STU(M6)

MS TU(M5)

MS TU(M 4)

MS TU(M 3)

M ST U(M2)

M STU(M1)

MS TU(PRT)

HK2
HK1
OCC INT F

BSW( M7 )
BSW(M 6)
BSW(M 5)
BSW( M4 )

T CU Y
TCU X

BSW(M 3)
BSW( M2 )
BSW(M 1)

H K2
HK1
O CC INT F
BSW( M7 )

BSW(M 6)
BSW( M5 )
BSW(M 4)

BSW(M 3)
BSW( M2 )

T CU Y
TCU X

BSW(M 1)

SV

RF Variable
Attenuator

SV

E CU1
E CU2

NFB

E CU1
E CU2

N FB

Connectors

T ERM

Connectors

TERM

STM-1
Analyzer

STM-1
Analyzer

BSW
HK 2
HK1
TCU2
TCU1
OCC INTF
BS W(M7)
BSW(M6)
BSW(M5)
B SW(M4)
BS W( M3 )
BSW(M2)
BSW(M1)

155M
CMI IN

SV
ECU1

S DH
Analyzer

155M
CMI OUT

NFB
WS IN

Connectors

TERM

WS OUT
WS IN
WS OUT

IMN-907006-E02 REV 03 APRIL 2010

31

Orderwire (OW) Transmission Test


Test Type:
Section test
Test Objective:
To check the functionality of the order wire (OW)
operation
Specifications:
The talking with order-wire is feasible by both E1 and E2
independently
Test instruments required:
Telephone set
Variable RF attenuator
PC (for WebLT)
Test set-up:
Set up the test circuits as shown in Figure 1-10.
Figure 1-10. OW Function Test
Attenuator
V a ATT
r ia b le A T T
Variable RF atte nuator

TELEPHONE
set

TELEPHONE
set

STM-1(CM1)

OU

OU

OU

OU

STM-1(CM1) IN

STM-1(CM1) IN
STM-1 Analyzer

STM-1 Analyzer
M1

M2

BSW unit
SCSU

32

STM-1(CM1)

M1

M2
BSW unit

SCSU

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Test Procedure
1.

Set up the test circuit as shown in Figure 1-10.

2. Call the station by the pressing of the station number.


To call an individual station, dial #1234 (1234: An example of the station number).
To call all stations in a group, dial #12**.(12: An example of the group number).
3. Confirm that the talking with order-wire is possible by both E1 and E2
independently.

Housekeeping function test


Test Type:
Hop test
Test Objective:
To check the functionality of the housekeeping function
Specifications:
The monitoring and remote control is feasible through
WebLT
Test Instruments Required:
Multi-meter (FLUKE 175 or equivalent)
PC (for WebLT)
Test set-up:
Shown in Figure 1-11 and Figure 1-12

Test procedure
1.

DI (Data Input: the monitoring function)


a.

Close the DI input port.

b.

Confirm that this monitoring information can be monitored with WebLT.

2. DO (Data Output: the remote control function)


a.

Select the remote control item and execute it with WebLT.

b.

Confirm that this DO port is closed.

Figure 1-11. Housekeeping Test (1/2)

SV for GP1/GP2

HK 1
CN34

W eb LT

IMN-907006-E02 REV 03 APRIL 2010

33

Figure 1-12. Housekeeping Function Test (2/2)


HK 1 (CN34)

DI
DI-1
DI-2
Photo
coup ler

DI-3
Ph oto
coup ler

Photo
coupler

Open/Close

DI-8

Photo
coupler

HK common ground

DO
DO-1C
Relay

DO-1N
DO-2C

Relay

DO-2N
DO-3C

Relay

Mult -meter

DO-3N
DO-4C
DO-4N

Relay

34

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Table 1-20. Connector PIN assignment for HK 1 (CN34)


PIN
No.

Description

Remarks

Pin
No.

Description

Remarks

19
37

18

36

17

35

16

34

15

33

14

DO-4C

Housekeeping OUT-4C

32

DO-4N

Housekeeping OUT-4N

13

DO-3C

Housekeeping OUT-3C

31

DO-3N

Housekeeping OUT-3N

12

DO-2C

Housekeeping OUT-2C

30

DO-2N

Housekeeping OUT-2N

11

DO-1C

Housekeeping OUT-1C

29

DO-1N

Housekeeping OUT-1N

10

HK-Common

HK Common Ground

28

HK-Common

HK Common Ground

SDA SG

Signal Ground for


Monitor

27

SD AGC

SD AGC monitor (W1)

26

AGC SG

Signal Ground for


Monitor

25

AGC MON

AGC monitor (W1)

24

DI-7

Housekeeping IN-7

23

DI-8

Housekeeping IN-8

DI-5

Housekeeping IN-5

22

DI-6

Housekeeping IN-6

DI-3

Housekeeping IN-3

21

DI-4

Housekeeping IN-4

DI-1

Housekeeping IN-1

20

DI-2

Housekeeping IN-2

FG

Frame Ground

IMN-907006-E02 REV 03 APRIL 2010

35

Rack Alarm Bus Function


Test Type:
Station test
Test Objective:
To check the functionality of the alarm information
output function
Specifications:
The relay contact to output the alarm information should
be closed at the alarm condition.
Test Instruments Required:
Multi-meter (FLUKE 175 or equivalent)
PC (for WebLT)

Test procedure
1.

Generate any alarm.


(NE ALM/RCI LED on SV unit lights in red when generated any alarm.)

2. Confirm contact closure with the multi-meter.


3. Apply closure to the ACO (Alarm Cut Off) input and confirm the ACO activation.
(ACO activation is that the alarm sound generated with the buzzer in the SV unit is
stopped. Relay contact remains closed.)
Figure 1-13. Rack Alarm Bus Test
TR6500 Radio Equipment

Rack Alarm Bus Output

NE ALM-N
NE ALM-C
Multi-mete r

+
Frame Ground
RL

AC O IN
Photo
Coupler

COMMON
V

SG

Equ ipme nt Type


N+1

36

CN n umb er

Re ma rk

CN 31

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Table 1-21. Rack Alarm Bus Pin Assignments and Interface Logic
Pin No.

Item

Description

Alarm Status

Power Down
Status

FG

Frame Ground

Common

Alarm common

12

NE ALM-C

NE Alarm (C)

CLOSE

OPEN

13

NE ALM-N

NE Alarm (N)

CLOSE

OPEN

14

ACO IN

Alarm Cut Off In

Cut off = CLOSE

15

ACO IN

ACO Ground

Cut off = CLOSE

2
3
4
5
6
7
8
9
10
11

Visual inspection
Test Type:
Test Objective:
implemented or not.

Station test
To check whether the required units and cables are being
To check whether the painting and finish are good or not

Test Procedure:
1.

Confirm that units and interconnecting cable have been installed in accordance
with the contract documentation.

2. Confirm that the painting and finish are good.

IMN-907006-E02 REV 03 APRIL 2010

37

Stability Test of STM-1 Signal


Test Type:

Hop test
To confirm that the STM-1 Signal output of the
TRuepoint 6500 radio equipment is error-free.
Specifications:
Error-free
Test Instrument Required:
STM-1 analyzer (MP1570A or equivalent)
Variable RF attenuator

Test Objective:

Test Procedure
1.

Perform the set up as shown in Figure 1-14 and Figure 1-15.

2. The data is measured for a continuous period of 12 hours.


Figure 1-14. Stability Test of STM-1 Signal

STM-1
Analyzer

STM-1

W-1 (GO)
W-2 (GO)
W-3 (GO)

LOOP BACK

LOOP BACK
W-1 (RTN)
W-2 (RTN)

W-3 (RTN)
STM-1

38

AVIAT NETWORKS

FACTORY ACCEPTANCE TEST PROCEDURE

Figure 1-15. Stability Test Set up


ATT
Variable RF attenuator

SD
RX
TX

DUP

ADPT

DUP

BPF
BPF
BPF

BP F
BP F
BP F

BP F
BP F
BP F

ADPT

SD
RX
TX

D UP

ADPT

D UP

B PF
B PF
B PF

B PF
B PF
B PF

B PF
B PF
B PF

M S TU(M 3)

MS TU(M2)

M S TU(M 1)

MS TU(P RT )

MS TU(M3)

MS TU(M2)

MS TU(M1)

M S TU(P RT)

SV

HK1

BSW (M 3)

TCU X

BSW(M 2)
BSW( M1 )

HK1

BSW( M3 )

T CU X

BSW( M 2)
BSW (M 1)

SDH
Analyzer

ADPT

SV
NF B

Connect ors

SDH Analyzer

N FB

TERM

Connec tors

T ERM

W3

W3

O
UT

O
UT

OU
T

OU
T

O
UT

OU
T

- (CMI)
STM-1

- (CMI)
STM-1

BSW

SCSU

IMN-907006-E02 REV 03 APRIL 2010

BSW

SCSU

39

40

AVIAT NETWORKS

IMN-907006-E02

WWW.AVIATNETWORKS.COM