Special Declaration
Copyright Inhemeter.All right reserved.
Sustainable product improvement is a policy in Shenzhen Inhemeter Co.,Ltd. Therefore, the
company reserves rights to change product operational details and specification. Contents of
this manual may be changed without notice. No part of the manual will be reproduced or
spread in any form or by any means for any purpose by any person or any other company
without permission in writing from Shenzhen Inhemeter Co., Ltd.
Trademark declaration
and other INHEMETER logos are trademarks of INHEMETER.
Other trademarks or registration trademarks mentioned in this document are possessed by
their respective owners.
VN:EKE201012-1
Index
Chapter1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
Executive Summary
What Is Keypad Prepayment Energy Meter
Applicable Standards on Keypad Prepayment Meters
STS Certifications Obtained by Inhemeter
Terminology
Technical Features
Categories of Inhe Keypad Prepayment Meter
Security Mechanism of Keypad Prepayment Meter
Basic Function of Products
Chapter2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
2.13
2.14
2.15
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
16
16
19
20
21
21
21
23
24
26
31
34
38
40
40
Technical Specification
Meter Shape Diagram
Meter Installation Diagram
Meter Installation Diagram
Wiring Diagram
Chapter4
1
2
3
5
7
8
10
12
14
Introduction
Technical Specification
Meter Shape Diagram
Meter Installation Diagram
Terminals
Wiring Diagram
Meter Active Metering Accuracy
Basic Characteristics
Measurement Function
Special Functions
LCD Display
Operation Detail
Communication Port
Safety Regulation
Installation
Chapter3
3.1
3.2
3.3
3.4
3.5
43
45
45
45
46
Introduction
Customer Interface Unit (CIU)
CIU Technical Parameters
Measurement and Control Unit (MCU)
MCU Technical Parameters
Single Phase Split Keypad Prepayment Meter
Three Phase Split Keypad Prepayment Meter
Three Phase Split Type Measurement Box
47
48
48
49
49
50
51
51
Chapter5
5.1 Introduction
5.2 Three Methods for Communication With MCU
5.3 Three Communication Modes With MCU
5.4 MCU Shape Drawing
5.5 MCU Installation Diagram
5.6 DIN Rail Mounting Diagram
5.7 MCU Terminals
5.8 MCU Typical Wiring Diagram
5.9 Characteristics
5.10 Single phase 2-wire/3-wire split type keypad prepayment energy meter
complying to ANSI
5.11 Single Phase ESKOM Keypad Prepayment Energy Meter
Chapter6
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
6.10
52
53
53
55
55
56
57
58
59
60
60
Introduction
SMARTvend Characteristic
SMARTvend Structure
SMARTvend Compatibility and Scalability
Diversified Power Vending Module
SMARTvend Functions
Consist of System
Consist of ISVA
Servers Applicable
System Characteristic
64
64
64
65
66
67
67
68
68
69
Chapter7
AMR/AMM of INHEMETER................................................................ 70
Chapter8
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
72
74
74
75
75
76
76
77
1
Chapter1
Token means a code consists of 20 digits of numbers, such as 2837 5872 3731 6854 3423.
Based on amount paid by the consumer, a unique token will be generated by Vending
Management system. Consumer need to input this token into meter through keypad on meter
to complete credit transfer process. (meter will decode the token within meter as per
communication protocol)
complete
system
frame
work
for
Prepayment
metering
system.
IEC62055consists of:
EC6205521
standardization structure
with STS standard (they also use standardized security module encryption algorithm) ,
therefore all prepayment meters manufactured by different meter manufacturers are
compatible with each others vending systems so long as the vending systems are also STS
certified.
As the only open prepayment metering system standard in the world, STS (Standard Transfer
Standard) has been widely accepted and adopted as prepayment metering system standard in
more than 70 countries. The arrangement of authorized access of STS technology (by STSA)
also assures safety and security of their application by Electricity Utilities.
As only prepayment meter products which obtain STS certification can ensure its compatibility
with other meter manufacturers STS certified prepayment metering system, Keypad
prepayment meter products of Shenzhen Inhemeter Co., Ltd. are also STS certified and the
manufacturers code is 37.
Inhe meters Keypad prepayment metering products also comply with following standards:
certification
ESKOM SCSSCAAA9
Africa
BS 5685
DIN 43857
1.5 Terminology
Shenzhen Inhemeter Co.,Ltd. | Terminology
1.5.1
MCU
MCU (Metering and control unit) for single/three phase integrated/split keypad prepayment
energy meter, installed outdoors, is the main body of meter. Its installation complies with meter
installation requirement and also supports Rs485 communication, infrared communication and
Power Line Carrier Wave Communication (PLC). MCU can have LCD display to display all
measured data such as accumulative kWh reading, history monthly kWh consumption, credit
charged, credit balance, load profile, warning/alarms and other data. Through different
communication means, MCU can also be programmed for it operation parameters or switching
tariffs under stepped multi-tariff arrangement.
1.5.2
CIU
CIU is customer interface unit used for single phase, three-phase split keypad prepaid energy
meter. It is installed indoor, which is convenient for user to learn meter operation parameters
and load pre-purchased energy(credit).
1.6.1
Feature of STS
STS is an open and secured transferring standard world wide and use IEC
62055-41 as the only intonation standard for prepayment system.
STS prepayment meter already installed and used by hundreds of Utilities world
wide.
Utility
can
purchase
products from
any
STS
certified
manufacturer or vending system supplier freely and need not worry security of the
system.
1.6.2
Multiple credit balance alarm (local warning, Short message service and email).
When remote charge fails, also support local keypad charging and infrared
communication.
1.6.3
Meter is installed in meter box, consumer can not and need not to touch meter.
Anti-tamper function.
AMR system and prepayment management system can be integrated into one
common purpose system.
Credit charge virtual token can be transferred with IC card, paper note, infrared
communication and PLC communication.
TOU tariff information and Stepped tariff information can be updated remotely.
1.6.4
meter, Three phase integrated type prepayment meter and Three phase
Split type prepayment meter.
11
POSpoint of sales
1.8.1
12
1.8.2
VUDKVending Unique Key, with VUDK unique vending key can be generated.
1.8.3
13
generation and security of keys. Generation and transferring process of all kinds of
keys (irrespective Vending system key or meter key) are all performed in encrypted
status, therefore. in any case, the contents of the key itself can not be interpreted
directly.
All the data are transferred in form of encrypted contents to prevent these contents
from being interpreted. Following principles of security and practical, the key is so
designed to facilitate operation and control of meter after the security requirement
is satisfied.
All the meters have unique key. With the help of above mentioned key
management flow, we can understand the distributed and related relation among
key, meter serial No., key version No., tariff index No., SGC and key type. these
relations ensured that one unique encryption key to one meter and as there is no
root encryption key present in vending system, security of the system will not be
threatened from root key side.
By using public key in meter manufacturing process and private key in meters
working status, as well as controlling meter working status key with SM which is
actively generating working status key with file provided by KMF, the system not
only successfully separated the security in meter manufacturing process and the
security in meter working status, but also successfully separated the meter
manufacturer and Utility. System security and safety is completely assured.
1.8.4
Security Certification
Product certified has already obtained certification from highest international
security certification authority.
STS system have used several encryption algorithms including DES3DES and
STA.
not only accurate measurement of energy, but also reliable control on electricity charge
collection. Inhemeters keypad prepayment meter products (including single and three phase
keypad prepayment meter, MCU CIU etc.) have following basic functions:
Event record functioncan record event such as terminal cover open, meter cover
open, power loss, phase loss, tariff change, meter date/time calibration, MD reset,
battery replacement and external magnetic influence.
Load control function provided, for different types of consumers, different load
control threshold can be programmed to control their consumption.
Visible/audible Low credit balance (in energy units/in monetary units) warning
signal provided, pre-warning and warning threshold credit balance level
programmable.
IP54 protection provided for outdoor use MCU and IP51 protection provided for
indoor use CIU.
Large size, wide visible angle, wide working temperature range LCD screen with
backlight
15 years life
STS certified
KEMA certified
15
Chapter2
2.1 Introduction
INHEMETER Single Phase Keypad Prepayment Energy Meter is for residential or commercial
use. It has been certified with STS (Standard Transfer Specification) regulation, and can
accept 20 digits STS code inputting. Adopts IEC62053, IEC62055 and IEC62056 standard,
and its design and production comply with ISO9001 standard.
Meter circuit design, structure design, choice of components and materials are made
according to allowable greater environment tolerance for reliable guarantee of lasting and
stable operation of meter. Metering components take shield protection measures in structure
design, which can resist interference of external DC and AC magnetic field, over-voltage and
high frequency electromagnetism field. Energy meter is with good electromagnetism
compatibility. These designs guarantee metering reliability and lasting stability, other
influences can be neglected and metering is highly reliable. Therefore, this meter do not need
to be calibrated during its whole life period.
Meter cover is made of fire retardant, flame resistant
and heat deformation resistant polycarbonate material.
The material is recyclable and friendly to environment.
Meter cover is double insulated and compliance with
IP54(IEC60529). Meter terminal is made of brass
material, and plated with nickel as tropical climate
energy meter. Terminal cover can be either short type
or extendable type, and fastened by a sealing screw.
Meanwhile, it can record events of opening terminal
cover after installation. Meter wiring complies with
DIN43857 and BS5685 standards.
The Meter can measure single phase two wire active AC electricity with frequency of 50Hz or
60Hz.
Specification
IEC 62052-11 2003
IEC 62053-21 2003
IEC 62055-31 2005
IEC 62055-41 2007
SANS 1524-1 2005
16
ESKOM SCSSCAAA9
Meter Type
active
electrical
power
can
be
computed
separately.
Anti-tamper function
(Optional)
STS manufacturer code
37
STS-154
220V (230V/240V)
Frequency
50Hz5Hz . 60Hz5Hz
Accuracy active
1.0
Nominal Current Ib
5A/10A
Starting current
20mA
30A,60A
/ 80A ,100A
90A
/120A
Meter constant
1600imp/kWh
2500A
LED
240V +20%
2.0
220V -30%
Max. tolerant over voltage
415V
(48 hours)
Current
5(30)A
5(60)A
Power consumption
@230V
17
Working environment
Operation temperature
-25+75
range
Storage and transport
-40+80
temperature range
Humidity requirement
Lightning protection
Communication port
1. Infrared communication
2. RS - 485 or RS - 232 (optional)
3. PLC
Meter reading interface: comply with ESKOM
SCSSCAAA9
Communication protocol
IEC62056-21 mode C
Baud rate: 2400bps
(option)
adopted.
In
this
case,
meter
becomes
1. columnar battery:
power (option)
1200mAh
18
2.3.2
19
20
2.5 Terminals
Unit: mm
Characteristics: pressure plate wiring mode is suitable for wires of different materials and diameters, and
it will not break the wire.
Power factor
Inhemeter Standard
0.02IbI< 0.05 Ib
1.5
1.0
0.05IbI< 0.10 Ib
1.5
1.0
0.10IbIImax
1.0
0.6
21
0.02IbI< 0.1Ib
0.1IbI< 0.2Ib
0.2IbIImax
0.5 lag
1.5
1.0
0.8 lead
1.5
1.0
0.5 lag
1.5
1.0
0.8 lead
1.5
1.0
0.5 lag
1.0
0.6
0.8 lead
1.0
0.6
Inhemeter single phase two wire energy meter active error range diagram
COS=0.5
22
3
4
5
interface
6
12-key keypad
2.8.1
10
Meter Panel
11
12
LCD display
13
Flash frequency of the red LED impulse light indicates instantaneous power load. The more
quickly it flashes, the higher the load is. Meanwhile, it can also be regarded as standard power
impulse output so as to check the accuracy of measurement.
Meter impulse constant is 1600imp/kWh, which means red LED flashes 1600 times when 1
kWh is used.
2.8.2
The green LED light indicates phase voltage (power grid is on). When the meter is connected
to power grid which is under normal power supply condition, the meter is in working status, the
green LED indicator light is on. When power is off or meter is not in working status, the green
LED indicator light is off.
2.8.3
The yellow LED light is the indication of meter abnormal status or alarm status. If the yellow
Shenzhen Inhemeter Co.,Ltd. | Basic Characteristics
23
LED light flashes or lights permanently, proper operation need to be carried out to solve the
problem otherwise it may influence energy consumption.
The yellow LED indicator light flashes: it means meter is in alarm status, for example balance
energy is less than alarm amount, power load exceeds limit, or meter is in abnormal status.
Proper action should be carried out according to information indicated on LCD display,
otherwise meter may cut off the power.
The yellow LED indicator lights permanently: it means power is cut off because balance
energy is zero, power load exceeds limit, or meter is in abnormal consumption status. Proper
action should be carried out according to information indicated on LCD display, for example,
recharge credit, reduce load, stop abnormal consumption.
2.8.4
The photoelectrical (infrared) communication port can be connected to portable device (HHU,
laptop, etc.) through a communication cable to read data from meter or set parameter for
meter. Communication protocol is compliance with model C in IEC62056-21.
2.8.5
12-key Keypad
The meter has a non-inductive, non-touch, silicon 12-key keypad, keypad is equipped with key
tone and Braille symbol. Token input and other actions can be operated on the keypad.
0-9 are 10 digits keys, which are used for inputting TOKEN code and short code. The other
two special keys are red
A.
enter key.
After inputting TOKEN code or short code, press Enter. If code is correct, purchased
kWh or credit will be entered into the meter and the meter will display corresponding
data item. Otherwise there will be alarm and corresponding wrong code indication on
LCD display.
B.
Press Enter key without inputting any code, scroll display data item can be checked
manually.
The meter can measure and save single phase two wire active energy. Measurement unit is
kWh. Measurement record is default as zero in factory. When accumulated active power
measurement reaches 999999.99kWh, the power record will return to zero again
automatically.
Both forward and reverse consumption will be added to active accumulated power.
Reverse consumption can be measured separately (optional).
Record and check(or download) daily (24 hours, 00:00---24:00) active energy of
recent 7 days.
Record and check(or download) monthly total active energy of recent 3 months
24
Active energy display method: 6+2 6 integrals and 2 decimals (factory default setting),
programmable setting is 7+1, 8+0 display modes.
2.9.2
DDZ1513 single phase keypad prepayment energy meter can measure, analyze and record
maximum demand, date and time of maximum demand within billing period.
Billing period is 1 month. The starting date of billing period is settable. setting range
is 1st-27th.
Demand measurement method is slide method. The slide is 1 minute, and cycle is 15
minutes.
2.9.3
It is programmable to choose
25
2.10
Special Functions
Note: If LCD indicated relay status does not match actual situation, it is possibly a malfunction,
please inform management department for servicing.
The meter is locked. The relay will reconnect automatically after locking. If locking time is deducted by
every second then remaining of locking time is displayed as unit of seconds, for example 150 seconds. If
deducted by every minute then remaining locking time is displayed as units of minute. When recovery
time is decreased to zero, the relay will reconnect.
27
This is a Optional function. If user power load is higher than load threshold (short code 015),
the meter will sound the alarm and yellow LED flashes. If user power load is higher than load
threshold and this situation lasts for 45 seconds, built-in relay will cut off power supply at the
45th second. The user need to manually press blue enter
button on keypad to
reconnect relay after 150 seconds of power off delay. If power load is still higher than threshold,
above process will be repeated. If continuous overload trip lasts 5 times within 30 minutes, the
meter will restore power supply after the delay of 45 minutes. The user can not manually
restore power supply during the delay.
28
bars remain only. User should recharge the meter in time. Power pre-warning threshold
amount and function can be set by inputting code: 4547 8xxxavailable set amount is
0kWh~999kWh.
will have two bars remain only. User need to press blue enter button on keypad
to reconnect power. Power warning threshold can be set by inputting code: 4547 9xxx
available set amount is 0kWh~999kWh.
Note: Power warning threshold amount must be less than pre-warning threshold amount. The
warning function will be shut off if power warning threshold amount or pre-warning threshold
amount is zero.
similar to battery power bar indication on mobile phone. Details can be found in the following
section.
29
month summary are configurable and is default as 24:00 of end day of the month.
The meter can save daily kWh consumption (00:00----24:00) of latest 7 days.
flashes,
and
lights permanently,
and
30
The meter will record reverse power event and turn on alarm light. On LCD
flashes alternately.
flashes alternately.
For following events, the meter can record latest 5 events with not only the date and
time of happening, but also related event data.
Recharge event (including recharging token code, TID code, recharge amount, time of
recharge)
2.11
LCD Display
DDZ1513 single phase keypad prepayment energy meter equipped with LCD display with
large screen, wide angle (120), wide temperature range and UV protection function. The
digit display is 8 bits (6 integrals and 2 decimals, or 7 integrals and 1 decimal, or 8 integrals
only). IEC62056 display code encoding, visualized reminding symbols, balance credit bar
indication, alarm/tip LED indication. LCD display is with backlight.
Digit size (height*width): 12X4.5mm
Power failure display function(optional)
Graphic symbol
Instructions
1.
2.
connect
2.
disconnect
31
Measurement unit
kWh: Active energy unit
kW: Active power unit
V: Voltage unit
A: Current unit
kVA: Apparent power unit
Unit of credit is amount of money.
coins symbol
Data area to indicate:
1.
2.
3.
2.
2.
2.
Normal working condition: built-in relay is connected, meter has certain amount of credits, kWh
32
consumption is displayed.
Meters measurement and records can be checked by following three methods:
Manual scroll display: press blue ENTER key manually to scroll display according to
configured items, sequence and time. Display duration of each item can be
programmed within 3~99 seconds. At most 20 items can be programmed in manual
scroll display (programmed by BCS). Manual scroll items will be displayed after
auto-scroll items, which means manual scroll items are: auto-scroll items + manual
scroll items (programmed by BCS).
Short code display: Specific item can be checked by inputting 3 digits of short code.
Display duration of each item is same with manual scroll display. LCD will return to
auto-scroll display after short code display.
4 bars
3 bars
2 bars
1 bar
Empty / flashing
Shape of balance credit bar depends on comparing result with warning and pre-warning
thresholds (kWh/amount).
Balance credit = 0
Bar is empty and frame flashes, relay disconnects and power is off (except for
over-draft, night/holidays). see diagram
33
Bar diagram can be used for power load indication (optional function),
Diagram means power load is higher than 100% of load threshold
Diagram means power load is higher than 75% of load threshold
Diagram means power load is higher than 50% of load threshold
Diagram means power load is higher than 25% of load threshold
Bar diagram can be used for estimated days of credit running out indication (optional
function),
Diagram means estimated days of credit running out are more than 30 days
Diagram means estimated days of credit running out are 15 days
Diagram means estimated days of credit running out are 10 days
Diagram means estimated days of credit running out are 5 days
Sad face
use electricity.
Operation incorrect, input TOKEN code is wrong and the meter
recharge is abnormal.
2.12
Operation Detail
Via 12-keys keypad users can input TOKEN code, passwords, short codes, and data codes
and TIKEN codes.
When digits are input via keypad, they will be displayed on LCD and move from the right to the
left. Every four digits will be separated by a dash. At the same time, number of digits will be
display on left top corner of the screen. While keyboard operation, all symbols not related to
inputting code will not be displayed. Below picture shows inputting procedure - 10 digits have
been entered.
Every digit enter will be accompanied with a key tone beep.
Red
to delete wrong digit. Every pressing can delete one digit from the right side of
screen.
Inputting interval of every two digits should not be more than 30 seconds, otherwise inputted
digits will be ignored and meter will return to normal display status.
34
Sound notification
Smile face
Sound notification
Sad face
35
Sound notification
Sad face
Sound notification
Smile face
Indicating Reject-1
Sound notification
Sad face
Note: Meter allows 3 times of false and retry when input one TOKEN. After 3 times TOKEN decoding
will be locked for a while, during which LCD indicates Reject-1 and PRd-Loc (period locked, for
example Loc-028 means period lock remains 28 seconds). Period locked will increase while times of
failure increases. But it will return to default when correct TOKEN is input after locking. This function will
prevent temper of random codes.
If the power is cut off because of terminal cover open, user has to go to apply for
tempering clearance TOKEN from Management Center. After inputting the TOKEN,
the meter will reconnect to power supply.
Note: While inputting tempering clearance TOKEN, other events logged in the
recorder will be cleared as well.
Load threshold can be changed by inputting load threshold TOKEN. If existing load
threshold is too low to meet users need, the user can apply to Management Center
for modifying load threshold. If applying is accepted, the Management Center will
generate a load threshold TOKEN. Meter load threshold will be revised by inputting
the load threshold TOKEN.
Pre-warning threshold can be configured by user-self: 4547 8xxx, the threshold can
be set between 0kWh~999kWh. There will be no pre-warning if set to zero.
Warning threshold can be configured by user-self: 4547 9xxx, the threshold can be
set between 0kWh~999kWh. There will be no warning if set to zero.
TOKEN
37
When test all functions (sequence of tests as per the list above), each item will take 2.5
seconds. While individual item test will take 5 seconds. The meter will return to normal
operation mode after test.
Retrieval of measuring data, computing data, recording data, setup parameter
and status, etc.
If short code is not exist, the data item is empty.
2.13
Communication Port
The meter has communication ports of photoelectric (infrared), RS485/232, ESKOM credit
reader port and twin cable communication port to CIU.
Notice: Its suggested that configuration should be done according to users requirement before meters
leave factory.
Accessory Name
Photoelectric communication cable
Instruction
Cable for communication between photoelectric port
and CMRI/HHU.
HHU TP900
CMRICMRI1010/CMRI1006
INHE AMI2010
39
2.14
Safety Regulation
The meter can be installed outdoor, indoor or in meter box. And its keypad, LCD, cover and
case are safe and insulated. But wiring security must be considered during installation incase
wires or terminals are left exposed.
2.15
Installation
Before installation, please make sure the appearance, seals, utility inspection notice
are complete. Meter should be installed on solid & fire resistant wall. Recommend
height is 1.4m~1.7m.
40
Wiring method should follow diagram printed in terminal cover. Copper wire/terminal
is recommended.
Insert wires by loosing the screws on terminal. Screws need to be fasten properly to
make sure security and good contact.
Close the terminal cover after wiring and seal the cover with sealing screw from
utility.
Fasten the wires tightly and always tidy them gently. Keep the meter clean from dust
and water etc.
Turn on the power supply and check meters working condition. Record data if it
works properly. Otherwise need re-check the installation and connection.
Handle with care to prevent dropping and bumping during installation.
Pay attention to operator and meter security during installation.
Notice: the meter adopts double circuits measurement method (anti-temper) which will measure both
phase and neutral lines and computing with the one of larger current only. Operator should make sure
the wiring and connection are correct during installation, so as to avoid repeated computations. Diagrams
of wiring are as follows:
Correct Installation
41
Incorrect Installation
Neutral line of B1,C1 and C2 are incorrect.
Error 1: Neutral incorrect. Extra kWh record. A=A+B1
Error 2: Neutral incorrect. Extra kWh record. C=C+C1+C2
Error 3: Neutral incorrect. Extra kWh record. C1= C1+C2
Correct: B, B1 and C2
42
Chapter3
Specification
Technical standard
Meter Type
43
Reactive energy
computation(optional)
37
Frequency
50Hz5Hz . 60Hz5Hz
1.0
/ 2.0
Reactive computation
2.0
/3.0
Nominal Current
Ib
5A
/10A
80A
/80A.100A
Starting current
20mA
Meter constant
400imp/kWh
accuracy
40mA
Keypad
or <10VA@230V
1.
Infrared communication
2.
3.
PLC
IEC62056-21 mode C
Baud rate: 2400bps
(option)
1: columnar battery:
(option)
unit: mm
45
Characteristics: pressure plate wiring mode is suitable for wires of different materials and diameters, and
it will not break the wire.
46
Chapter4
4.1 Introduction
INHEMETER Split Keypad Prepayment Energy Meter is civil or commercial used single-phase
multi-components keypad prepayment energy meter compliance with STS (Standard Transfer
Specification) regulation, which can accept 20 digits STS code inputting and pass STS test
certification. It includes two components:
INHEMETER split keypad prepayment energy meter adopt international IEC62053, IEC62055
and IEC62056 standard, and the design and production comply with ISO9001 standard.
Meter circuit design, structure design, choice of components and materials are made
according to allowable greater environment tolerance for reliable guarantee of lasting and
stable operation of meter. Metering components take shield protection measures in structure
design, which can resist interference of external DC and AC magnetic field, over-voltage and
high frequency electromagnetism field. Energy meter is with good electromagnetism
compatibility. These designs guarantee metering reliability and lasting stability, other
influences can be neglected and metering is highly reliable. Therefore, this meter does not
need to be calibrated during its whole life period.
Meter cover is made of fire retardant, flame resistant and heat deformation resistant
polycarbonate material. It can be recycled after the end of its life cycle to save environment.
MCU cover is double insulated and compliance with dust and watch protection standard IP54
(IEC60529). MCU terminal is made of brass material, and plated with nickel as tropical climate
energy meter. MCU terminal cover can be short or extended, and fastened by a sealing screw.
Meanwhile, it can record events of opening terminal cover after installation. MCU wiring
complies with DIN43857 and BS5685 standards.
Split keypad prepaid energy meter operation diagram:
47
DDZ1513-CIU-PLC
DDZ1513-CIU-RF
Communication types
Supply mode
Communication distance
Keyboard
Cable specification
2.5 mm2
Dimension
Communication types
Supply mode
Communication distance
200 meters
48
Keyboard
Cable specification
2.5 mm2
Dimension
Communication types
Supply mode
Communication distance
Keyboard
Cable specification
2.5 mm2
Dimension
DDZ1513-CIU-PLC
DDZ1513-CIU-RF
Specification
Single-phase two wire direct access type meter
Meter Type
49
separately.
Anti-tamper function
(Optional)
STS manufacturer code
37
STS-154
50Hz5Hz . 60Hz5Hz
Accuracy active
Single Phase:Class1.0
Class2.0
Class2.0
Nominal Current
Ib
5A/10A
Starting current
20mA
30A,60A
90A
Meter constant
Single phase:1600imp/kWh
/ 80A ,100A
120A
220V -30%
415+20%
display component
50
DDZ1513-CIU
DTZ1513-MCU-KBS
Measurement and Control Unit Customer Interface Unit
DDZ1513-CIU
DTZ1513-MCU-BS
Measurement and Control Unit Customer Interface Unit
DTZ1513-MCU-BOX
Measurement and Control Unit
DDZ1513-CIU
Customer Interface Unit
300/5A
500/5A
800/5A
1200/5A
51
Chapter5
5.1 Introduction
DIN rail mounted Single Phase Split Keypad Prepayment Energy Meter is civil or commercial
used single-phase multi-components keypad prepayment energy meter compliance with STS
(Standard Transfer Specification) regulation, which can accept 20 digits STS code inputting
and pass STS test certification. It includes two components:
A: MCUMeasurement and Control Unit. Split keypad prepayment energy meter MCU unit can
be installed outdoor, or in centralized meter box or on telegraph pole.
B: CIU: Customer Interface Unit. Split keypad prepayment energy meter CIU unit is installed
indoor, which is convenient for user to learn meter operation parameters and load
pre-purchased energy (credit). Inhemeter DIN rail mounted single phase split keypad
prepayment energy meter adopt international IEC62053, IEC62055 and IEC62056 standard,
and the design and production comply with ISO9001 standard.
DDZ1513-MCU-DIN is MCU without display component
DDZ1513-MCU-DIN-LCDS is MCU with display component
Meter circuit design, structure design, choice of components and materials are made
according to allowable greater environment tolerance for reliable guarantee of lasting and
stable operation of meter. Metering components take shield protection measures in structure
design, which can resist interference of external DC and AC magnetic field, over-voltage and
high frequency electromagnetism field. Energy meter is with good electromagnetism
compatibility. These designs guarantee metering reliability and lasting stability, other
influences can be neglected and metering is highly reliable. Therefore, this meter does not
need to be calibrated during its whole life period.
Meter cover is made of fire retardant, flame resistant and heat deformation resistant
polycarbonate material. It can be recycled after the end of its life cycle to save environment.
MCU cover is double insulated and compliance with dust and watch protection standard IP54
(IEC60529). MCU terminal is made of brass material, and plated with nickel as tropical climate
energy meter. MCU mounting complies with DIN VDE 0611-1 and EN60947-7-1 standards.
52
DIN rail mounted single phase split keypad prepaid energy meter operation diagram:
DDZ1513-CIU-CABLE
DDZ1513-CIU-PLC
DDZ1513-CIU-RF
MCU of DIN rail mounted single phase split keypad prepaid energy meter is installed outdoors.
Generally it can be installed in special metering box by fixing on DIN rail without mounting
screws.
53
DDS1513-CIU-PLC
DDS1513-CIU-RF
54
5.5 MCU
Installation Diagram
Unit: mm
55
56
57
58
5.9 Characteristics
MCU unit without display components
59
5.10
5.11
60
Shenzhen Inhemeter Co.,Ltd. | Single phase 2-wire/3-wire split type keypad prepayment energy
meter complying to ANSI
Shenzhen Inhemeter Co.,Ltd. | Single Phase ESKOM Keypad Prepayment Energy Meter
61
62
Shenzhen Inhemeter Co.,Ltd. | Single Phase ESKOM Keypad Prepayment Energy Meter
Shenzhen Inhemeter Co.,Ltd. | Single Phase ESKOM Keypad Prepayment Energy Meter
63
Chapter6
6.1 Introduction
SMARTvend: Inhemeter smart network power vending management system(Smart Vending
Anywhere) is introduced after years of experience of developing IC prepayment energy meter,
keypad prepayment energy meter, SMS prepayment energy meter power vending
management system and after-payment power vending management mode. It uses B/S and
C/S mixing network construction and network data is under centralized management. Value
added service, various power vending, 7*24 power vending anywhere can be realized by
co-operation with the bank, the network companies, etc. It is mainly used to manage energy
charge collection of utilities, companies, schools and etc, and plays important role in automatic
collection of energy charges and load control. Smart Vending Anywhere SystemSVASbrings
convenience, efficiency and security for users and thus simplifies the complexity of
management, reduces cost and improves revenue collection.
Various power vending methods available, i.e. vending through internet, ATM,
agent, scratch card.
Multi-station or single station management for vending points. Vending points can
be centralized for control and vending authorization.
Support all STS certified meter and IC card prepayment meter as well.
Users are given rights according to position which can be done to each control point
of each module.
Built-in third party data exchange port and can communicate with external
marketing and automatic meter reading system.
Desktop user-defined
Web Server: used for providing HTTP service to connect vending points of utility
company, and connection for bank payment collection, internet power vending,
vending agency, etc.
64
Data
Notice: Abovementioned server application can be grouped according to customer demand and
development condition. all service function operated in one server is supported as well.
Other Systems:
Other System port: payment collection through agents like network company,
telecommunication company or scratch card.
65
prepayment energy meter researched by Inhemeter, as well as STS keypad energy meter
made by different manufacturers. Meanwhile, it makes SMARTvend SVAS compatible with
prepayment energy meter with different type and different protocol, prepayment water meter,
prepayment hot water meter and gas meter by system third party extended interface base.
ATM: Users purchase electricity from ATM self-help equipment. Recharge will be
made by connecting with bank system after safety certificate. ATM will read the
card and print digit code.
POS, PDA recharge: Users enter network vending website by internet with
handhold computer for recharge (It can not recharge for IC prepayment energy
meter).
Agent vending: Banks or other agent vendors authorized by the utility provide
vending business for users.
Recharge hall: Integrated petty charges recharge hall provide electricity vending
business.
66
Scratch card: Telecom companies use their value added service to transfer the
recharge payment and give recharge instruction (It can not recharge for IC
prepayment energy meter).
SMS: Telecom companies use their value added service to transfer the recharge
payment, and after successful recharge transferring, recharge can be made by
SMS. It is applicable for SMS prepayment energy meter and STS keypad
prepayment energy meter (It can not recharge for IC prepayment energy meter).
keypad
prepaid
power
vending
management
system
(Smart
Vending
67
Anywhere)uses B/S and the C/S mixing network construction and network data is under
centralized management. Value added service and various power vending can be realized by
co-operation with the bank, the network companies, etc. INHEMETER Smart Vending
Anywhere (ISVA) brings convenience, efficiency and security for users and thus simplifies the
complexity of management, reduces cost and improves revenue collection.
Web Server: used for providing HTTP service to connect vending points of utility
company, and connection for bank payment collection, internet power vending,
vending agency, etc.
Data
Exchange
data exchange
Other System port: payment collection through agents like network company,
telecommunication company or scratch card.
68
6.10
System Characteristic
Various power vending methods available, i.e. vending through internet, ATM,
agent, scratch card.
Multi-station or single station management for vending points. Vending points can
be centralized for control and vending authorization.
Support all STS certified meter and IC card prepayment meter as well.
Users are given rights according to position which can be done to each control
point of each module.
Built-in third party data exchange port and can communicate with external
marketing and automatic meter reading system.
Desktop user-defined
MultiStatio
Single Station
69
Chapter7
AMR/AMM of INHEMETER
The Public Basic Energy/Resources Information Acquisition & Control Management System
(AMR/AMM) of INHEMETER Instrument Co., Ltd is a comprehensive AMR/AMM solution
which contains local data acquisition of electricity/water/gas meters, data transmission by
remote communications, data storage in system master station, data analysis and marketing
management. It provides energy/resources consumption data and control & management
methods to the public utilities of electricity, water and gas during their business applications, in
order to achieve rational resources distribution, reduce energy loss, improve energy/resources
utilization efficiency, save resources and protect environment, and maximize the social
benefits ultimately.
The Public Basic Energy/Resources Information Acquisition & Control Management System
(AMR/AMM) can effectively promote the utilities to realize their standardization and scientific
management in measurement, meter reading, control and charging mode etc. It can provide
accurate, real-time and reliable date from the source of users energy/resources consumption,
reflect customer demand quickly and enhance the utilities service level and their fast response
ability to market changes. In order to fulfill social responsibilities and respond to the energy
saving policies of Government, this system provides a strong technical support to implement
time-of-use tariff & stepped tariff of electricity/water/gas and adjust electricity/water/gas price
70
timely and effectively based on the changes in market of energy/resources supply and
demand.
The Public Basic Energy/Resources Information Acquisition& Control Management System
(AMR/AMM) of INHEMETER Instrument Co., Ltd is divided into the following three parts based
on
its
physical
structure:
System
Master
Station,
Communication
Channel,
and
Acquisition/Control Equipments of Utility Meters are the metering data acquisition terminals
and utility meters installed in the measurement/control sites of public basic energy/resources.
For the power industry, it includes mainly metering data acquisition terminals in power
plant/substation, special transformer acquisition terminals, public transformer acquisition
terminals, remote communication multi-function meters, data concentrators in low-voltage
transformer district as well as all the single-phase/three-phase watt-hour meters with function
of short-range communication. For water/gas industry, it includes mainly concentrators,
collectors as well as all the water/gas meters
71
72
73
74
Shenzhen Inhemeter Co.,Ltd. | Order List of DIN rail-mounting Single-phase Split Keypad Meter
75
76
Model
Name
Unit
diagram
Prepayment power
1
SMARTvend
vending management
system for IC card and
set
Keypad
Hand Held Unit
(HHU)
PSION TEKLOGIX
WORKABOUT PRO3
7527C-G2
2
(including meter
set
reading software)
Huaxia
PDA-2
(including meter
set
reading software)
Optical
3
communication
pcs
cable
TP-USB-IEC
Security Module
TSM210-USB
Magnetic card reader
YD-626
set
set
Bill printer
Desktop thermal
printer
SRP150
set
6
Desktop multi-stylus
printer
Portable printer
7
SRP270
set
SPP-R200BG
(with leather case and
set
battery
77
Contact with us
78