Professional Documents
Culture Documents
DV DLH Er-Gb 4800135 0706
DV DLH Er-Gb 4800135 0706
DV DLH Er-Gb 4800135 0706
DV
DLH
ER
Technical Description
Fan range DV 30
The fans of the range DV 30, for horizontal discharge, are suitable
for discharging slightly polluted but not aggressive air or vapours
from - 20C to app. + 40C. The rectangular casing, made of
galvanised sheet steel, has two opposite mounted discharge outlets
protected from the weather with an aerodynamically shaped grille,
which provide for horizontally directed, swirl-free air discharge.
All roof fans are equipped with an isolator switch ready for
connection.
Motors
Well tried and tested integral drive motors are used. Noise-tested,
maintenance-free deep-groove ball bearings give the motor long
life. To avoid overheating, every motor is equipped with thermal
contacts. This thermal protection has to be effective in operation
in order to enable the user to claim for warranty in the case of
break down. Please follow the instructions of the wiring diagram
for connecting the thermal contacts correctly.
Roof
fan
type DV
Voltage
V
Flow
rate
Vmax m/h
30-22-2E
30-22-4E
30-25-2E
30-25-4E
230
230
230
230
Speed
min-1
Max.
absorbed
power kW
Full load
current
A
1step
680
445
1250
800
2370
1400
2020
1390
0,11
0,04
0,16
0,06
0,46
0,17
0,68
0,28
E1-16
E1-16
E1-16
E1-16
40-28-4/4 3x400Y
40-28-4E
230
40-28-6E
230
40-31-4/4 3x400Y
40-31-4E
230
40-31-6E
230
1730/1570
1690
1120
2440/2010
2550
1670
1420/1260
1380
910
1340/1070
1420
920
0,13/0,09
0,16
0,08
0,19/0,13
0,23
0,12
0,40/0,16
0,76
0,34
0,43/0,22
1,2
0,54
56-35-4/4
56-35-4E
56-35-6E
56-40-4/4
56-40-6/6
56-40-4E
56-40-6E
56-45-4/4
56-45-6/6
56-45-4E
56-45-6E
3x400Y
230
230
3x400Y
3x400Y
230
230
3x400Y
3x400Y
230
230
3470/2910
3470
2380
4830/4250
3100/2520
4340
3100
6800/6130
4190/3060
6450
4150
1340/1080
1340
930
1400/1190
890/690
1220
890
1420/1250
860/600
1330
850
0,35/0,22
0,40
0,15
0,58/0,44
0,22/0,13
0,52
0,20
0,95/0,76
0,30/0,17
0,95
0,31
71-50-4/4
71-50-6/6
71-50-4E
71-50-6E
71-56-4/4
71-56-6/6
3x400Y
3x400Y
230
230
3x400Y
3x400Y
9150/7740 1350/1100
6250/5430
930/780
8660
1260
6100
900
12580/9950 1270/960
8990/7790
920/770
Control units*
Sound
Wiring Weight
25steppower
diagram
step
step
less LWA Vmax dB No.
kg
-
E5-1
E5-1
E5-1
E5-1
ES-3
ES-3
ES-3
ES-3
72
64
77
66
507
507
507
507
5,5
5,0
6,5
6,0
D1
DS
E1-16
E1-16 E2-6
D1
DS
E1-16
E1-16 E2-6
D5-1
E5-1
E5-1
D5-1
E5-1
E5-1
ES-3
ES-3
ES-3
ES-3
71/68
70
59
71/66
72
61
515
508
508
515
508
508
23
22
22
23
23
23
0,75/0,39
1,9
0,72
1,35/0,74
0,55/0,23
2,3
0,91
2,30/1,30
0,67/0,32
4,4
1,4
D1
E1-16
E1-16
D1
D1
E1-16
D1
D1
E1-16
DS
DS
DS
DS
DS
-
D5-1
E5-3
E5-1
D5-3
D5-1
E5-3
E5-1
D5-7
D5-1
E5-7
E5-1
ES-3
ES-3
ES-3
ES-3
77/72
77
67
80/77
69/63
77
69
83/80
70/62
82
70
515
508
508
515
515
509
508
515
515
509
508
35
35
35
40
37
40
37
44
44
44
44
1,60/1,05
0,52/0,38
1,45
0,54
2,40/1,46
0,82/0,59
3,20/1,80
1,30/0,69
6,3
2,6
4,30/2,4
2,10/1,1
D1
D1
D1
D1
DS
DS
DS
DS
D5-7
D5-3
E5-7
E5-3
D5-12
D5-7
85/80
75/71
84
75
86/80
78/74
515
515
509
509
516
515
73
64
72
64
82
71
900/700
880/680
870
650
950/480
1,30/0,88
2,50/1,50
3,4
1,6
4,4/0,7
2,9/1,7
5,0/2,8
6,5
3,3
8,7/2,6
D1
D1
D1
-
DS
DS
-
D5-7
D5-12
D5-7
-
81/76
85/79
86
78
88/70
515
516
502
534
551
119
139
140
135
166
125-80-6 * 3x400
125-80-8 3x400
945
660
960/480
940
5,2
2,0
5,5/0,85
8,8
10,2
4,4
11,0/3,3
16,4
D1
-
D5-12
-
90
81
90/72
94
549
537
551
549
215
206
215
238
125-80-6/12 3x400YY/Y
24800
17600
24800/12470
125-90-6 * 3x400Y
* Fan not speed controlled
34550
General instructions
Safety Guards
All roof extract fans are supplied with a discharge-side mesh safety guard in accordance
with DIN EN 294. The inlet side is not fitted with a standard guard, because it is normal
practice to attach other system parts to the side. However, if the unit is installed in such
a way that accidental contact with the impeller is possible, an additional inlet guard has to
be fitted acc. to DIN EN 294! The fans may only be put into operation if all necessary
protection devices are fitted and made effective (see maintenance instructions)! The
safety guards are to be executed acc. to DIN EN 292 1, chapter 3.22 Separating safety
devices and DIN EN 292 2, chapter 4 Technical protection measures.
Safety instructions
Transport, fitting, electrical connection, start up, and maintenance are to be executed
following to the instructions given with the manual and by respecting the actual standards,
guide lines, and safety rules.
Performance data
The performance curves are obtained using an inlet side test chamber in accordance with
DIN 24 163-2 Fans, performance tests, standard test equipment. The performance grids
show the effective pressure increase pfa (Pressure increase obtained from the fan in
free-field conditions) as a function of the flow volume VL.
Reference media density: 1 = 1.15 kg/m. The roof fans comply with the tolerances of
Class 2 of DIN 24 166 Fans, Technical Specifications.
Sound Data
Measurement and evaluation of noise levels are in accordance with DIN 45 635 - 38
Sound measurements on machines; fans. In the technical data the A-weighted sound
power level at maximum flow rate is given.
The computer aided data collection and evaluation enables to obtain highly reliable data
precision. In the curves the emission value of the A-sound-power level LWA is given,
having the same value for intake (LWA3) as for the discharge (LWA8).
For more exact calculations when determining the required attenuation, the sound power
level in the octave bands is important.
LWoct 3/8= LWA + LWrel 3/8
The relative sound power levels for inlet and discharge sides, at various duty points, can be
read from the corresponding tables.
Because conditions in the operating environment are usually far from ideal for
measurement and can vary greatly, a determination of the A-sound-pressure level at any
distance is only possible with great uncertainty.
30
dB
a
b
20
10
m 10
LPA LWA L
The diagram on the left side supplies the correction value L in function of the distance
r from the fan centre. Under ideal conditions, with a clear hemisphere of sound
propagation, curve a is valid. However, curve b is recommended for practical estimates.
The calculation of the intake sound-power level is only possible if the exact noise
parameters of the connected room are known (see VDI 2081!).
Due to turbulences generated by the back draught damper the sound data for intake and
discharge may increase by app. 3 dB at discharge when a damper is fitted.
It is recommended to provide a duct section between fan and damper because under this
configuration the indicated pressure drops are applicable.
If the damper is directly fitted to the fan higher pressure losses have to be expected.
Flow
rate
Vmax m/h
680
445
1250
800
V
230
230
230
230
Speed
Absorbed
power
max kW
0,11
0,04
0,16
0,06
min-1
2370
1400
2020
1390
Control units*
25step
step
E5-1
E5-1
E5-1
E5-1
1step
E1-16
E1-16
E1-16
E1-16
Pa
74
DV 30-25-2E 1
DV 30-25-4E 2
78
DV 30-22-2E 1
DV 30-22-4E 2
dB
dB
400
Full load
current
A
0,46
0,17
0,68
0,28
L WA
LW
Pa
Voltage
Performance Data DV 30
500
350
73
300
400
76
250
70
300
1
62
100
2 5
9
50
72
64
0
100
200
300
0
0,05
Flow rate V
400
600
500
0,15
0,1
*
m/h
150
70
200
72
200 67
74
2 63
100
77
66
0
200
400
600
0
0,1
Flow rate V
m/s
*
1200 m/h
1000
800
0,3
0,2
m/s
12
18
22
Pressure loss
Pressure loss pA through silencer upstand, at flow rates of
750
900
Silencer upstand
ZDS..-0028
22
30
Intake(LWrel3 = LWoct3 - LWA3 )
Relative sound power level LWrel3 at mid frequencies fm
Duty point 6 3
DV 30-22
0,3 Vmax
9
0,6 Vmax
9
Vmax
7
DV 30-25
0,3 Vmax
9
0,6 Vmax
9
Vmax
7
20
15 dB
1000
m/h
40 Pa
Hz
Duty point
63
125 250
500
Hz
9
7
4
5
4
2
-2
-2
-1
-11
-10
-9
-18
-16
-12
-22
-20
-16
-31
-28
-22
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
-7
-7
-11
-3
-4
-5
0
-2
-4
-3
-3
-4
-6
-6
-5
-7
-7
-7
-14
-13
-12
-24
-23
-21
dB
dB
dB
9
7
4
5
4
2
-2
-2
-1
-11
-10
-9
-18
-16
-12
-22
-20
-16
-31
-28
-22
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
-7
-7
-11
-3
-4
-5
0
-2
-4
-3
-3
-4
-6
-6
-5
-7
-7
-7
-14
-13
-12
-24
-23
-21
dB
dB
dB
Dimensions DV 30
Mains lead
DV 30-22
97
6M6
330
25
ZBU 01-0028-18
Connecting plate
ZDS 20-0028
Silencer upstand
278
245
183
250
ZBS 20-0031
Flat roof
295
245
upstand
97
21
M6
341
DV 30-25
M6
6
410
Mains lead
ZBU 01-0028-22
Connecting plate
229
6M6
6M6
190
M
6
115
765
300
610
213
259
518
518
518
ZBS 23-0031
Flat roof upstand high
ZDS 09-0028-#
Silencer upstand for inclined roof
278
245
278
245
ZKF 01-0180
Intake flexible connection
67
ZKF 13-0225
Intake flexible connection
67
190
183
213
233
229
259
279
150
518
ZBS 09-0031-#
Upstand fr inclined roof
ZKF 01-0180
Mating flange
M
6
278
245
150
150
67
ZKF 13-0225
Mating flange
67
183
213
233
229
259
279
M
6
150
ZBS 11-0031
Soaker sheet (for corrugated roof)
ZLK 03-0225
Automatic back draught
damper
67
229
259
279
M
6
290
920
Flow
rate
Vmax m/h
1730/1570
1690
1120
2440/2010
2550
1670
Speed
min-1
1420/1260
1380
910
1340/1070
1420
920
Pa
A
=6
200 6
8
9d
Full load
current
A
0,40/0,16
0,76
0,34
0,43/0,22
1,2
0,54
DV 40-31-4/4 1 2
DV 40-31-4E 3
DV 40-31-6E 4
240
65
40
400
800
0
0,1
0,2
Flow rate V
1200
0,3
1600
2000
0,4
0,5
72
71
0
0,1
Flow rate V
66
62
71
70
68
59
80
69
50
57
70
67
61
61
68
120
65
53
160
3
2
100 5
7
67
62
68
150
200 6
6
64
Control units*
125step step
step
D1
DS
D5-1
E1-16
E5-1
E1-16 E2-6
E5-1
D1
DS
D5-1
E1-16
E5-1
E1-16 E2-6
E5-1
Pa
280 LWA =
72
dB
71
DV 40-28-4/4 1 2
DV 40-28-4E 3
DV 40-28-6E 4
67
Absorbed
power
max kW
0,13/0,09
0,16
0,08
0,19/0,13
0,23
0,12
LW
Performance Data DV 40
2400
0,6
0,7
m/h
m/s
15
22
20
13
14 dB
13
19
23
21
15 dB
Pressure loss
Pressure loss pA through silencer upstand, at flow rates of
1500
2000
3000
Silencer upstand
ZDS..-0040
25
40
100
4000
m/h
170
Pa
63
Hz
Duty point
63
125 250
500
Hz
12
11
4
13
10
11
0
-1
-1
-6
-5
-5
-10
-7
-7
-11
-9
-10
-18
-15
-17
-32
-29
-30
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
5
-4
-9
0
-3
-2
-1
-3
-2
-5
-4
-4
-5
-5
-5
-6
-7
-7
-13
-13
-13
-22
-22
-25
dB
dB
dB
13
8
2
14
13
12
-2
-3
-3
-6
-6
-5
-11
-10
-8
-12
-11
-11
-16
-16
-16
-29
-28
-28
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
3
-5
-10
2
1
1
0
-1
-1
-5
-5
-4
-6
-6
-5
-7
-7
-7
-13
-12
-12
-20
-21
-22
dB
dB
dB
Dimensions DV 40
Mains lead
ZDH 20-0250
Discharge silencer
138
410
28
6
M6
6
M6
440
671
12
626
ZBS 20-0040
Flat roof upstand
ZKK 20-0040
Intermediate piece
395
330
ZBU 01-0040-25
Connecting plate
256
M10
6M6
11.5
330
386
400
710
286
618
M
10
ZDS 20-0040
Silencer upstand
378
330
650
270
ZBS 23-0040
Flat roof upstand high
ZKE 11-0250
Intake flexible connection
67
378
330
618
256
286
306
ZDS 09-0040-#
Silencer upstand for inclined roof
378
330
618
535
270
ZBS 09-0040-#
Upstand for inclined roof
378
330
67
150
256
286
306
ZBS 11-0040
Soaker sheet (for corrugated
roof)
67
256
286
306
ZLK 21-0250
Damper with actuator
7
207
185
M
10
319
# = inclination up to 45 possible
within 5 steps. Indicate inclination
with type when ordering ZBS 090031-05 (od. 10, 15, 20, 25, 30, 35,
40, 45)
When using damper ZLK and
upstand silencer ZDS the damper
has to be fitted by using a plate
ZBU below silencer upstand.
When fitting damper to fan an
intermediate piece ZKK must be
added.
ZLK 01-0250
Automatic back draught
damper
180
10
150
340
618
150
M
10
150
ZKF 11-0250
Mating flange
920
256
286
306
Voltage
Flow
rate
Vmax m/h
3470/2910
3470
2380
4830/4250
3100/2520
4340
3100
6800/6130
4190/3060
6450
4150
V
3x400Y
230
230
3x400Y
3x400Y
230
230
3x400Y
3x400Y
230
230
Speed
min-1
1340/1080
1340
930
1400/1190
890/690
1220
890
1420/1250
860/600
1330
850
Pa
350 L
W
=7
Full load
current
A
0,75/0,39
1,9
0,72
1,35/0,74
0,55/0,23
2,3
0,91
2,30/1,30
0,67/0,32
4,4
1,4
1step
D1
E1-16
E1-16
D1
D1
E1-16
D1
D1
E1-16
Control units*
25step
step
DS
D5-1
E5-3
E5-1
DS
D5-3
DS
D5-1
E5-3
E5-1
DS
D5-7
DS
D5-1
E5-7
E5-1
4d
LW
70
69
64
50
200 67
80
1 2
3 4
5
3
80
79
70
61
77
65
0,6
0,8
4000
m/h
1,2 m/s
1,0
2000
0,6
3000
0,8
70
62
4000
1,0
1,2
5000
1,4
6000 m/h
1,6
15
22
20
13
14 dB
12
18
21
20
15 dB
Pressure loss
Pressure loss pA through silencer upstand, at flow rates of
3000
4000
6000
Silencer upstand
ZDS..-0056
25
42
80
83
82
80
Attenuation values
Average
Values
Discharge silencer
ZDH 20-0355 11 dB
Silencer upstand
ZDS..-0056 16 dB
300
0,4
3000
2000
0,4
74
0,2
0,2
76
1000
0
80
63
0
78
400
1000
77
DV 56-45-4/4
DV 56-45-6/6
DV 56-45-4E
DV 56-45-6E
LW
A =8
2 dB
81
56
100
Flow rate V
Pa
56
62
61
Flow rate V
200
5
2
77
70
70
69
77
72
67
1000
0,1 0,2
74
100
500
74
75
74
61
1 2
3 4
5
3
77
150
100
dB
300
65
65
500
DV 56-40-4/4
DV 56-40-6/6
DV 56-40-4E
DV 56-40-6E
75
70
200
= 79
400 7
6
Pa
DV 56-35-4/4 1 2
DV 56-35-4E 1
DV 56-35-6E 3
300
250
Absorbed
power
max kW
0,35/0,22
0,40
0,15
0,58/0,44
0,22/0,13
0,52
0,20
0,95/0,76
0,30/0,17
0,95
0,31
Performance Data DV 56
m/s
8000
m/h
160
Pa
Flow rate V
Intake(LWrel3 = LWoct3 - LWA3 )
Relative sound power level LWrel3 at
Duty point 6 3 125 250 500
DV 56-35
0,3 Vmax
16 12
1
-3
0,6 Vmax
11 11
1
-3
Vmax
8
11
1
-2
DV 56-40
0,3 Vmax
12 12
1
-3
0,6 Vmax
11 11
0
-4
Vmax
7
10
1
-3
DV 56-45
0,3 Vmax
1 2 1 3 -1
-6
0,6 Vmax
5
13
0
-6
Vmax
1
13
0
-5
10
mid frequencies fm
1000 2000 4000 8000
Hz
Hz
-11
-10
-10
-15
-11
-11
-19
-16
-19
-28
-26
-25
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
4
-3
-6
1
-1
0
-1
-3
-3
-4
-4
-4
-4
-5
-5
-8
-6
-6
-12
-12
-15
-21
-20
-21
dB
dB
dB
-10
-8
-8
-15
-12
-12
-18
-16
-19
-28
-24
-20
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
5
0
-4
2
1
1
0
-1
0
-4
-5
-4
-4
-5
-5
-9
-7
-8
-13
-11
-12
-19
-18
-15
dB
dB
dB
-11
-11
-11
-15
-14
-14
-19
-16
-19
-27
-25
-20
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
5
-2
-6
3
2
2
-1
0
0
-4
-5
-4
-5
-6
-5
-9
-8
-8
-12
-10
-13
-17
-17
-15
dB
dB
dB
Dimensions DV 56
Mains lead
DV 56
ZDH 20-0355
Discharge silencer
192
600
39
5
M8
8
M8
600
881
12
836
ZBS 20-0056
Flat roof upstand
ZKK 20-056
Intermediate piece
555
450
ZBU 01-0056-35
Connecting plate
361
M10
8M8
11.5
450
546
560
870
395
778
M
10
ZDS 20-0056
Silencer upstand
538
450
ZKE 11-0355
Intake flexible connection
430
800
ZBS 23-0056
Flat roof upstand high
89.5
538
450
361
395
421
778
ZDS 09-0056-#
Silencer upstand for inclined roof
778
538
450
ZBS 09-0056-#
Upstand for inclined roof
ZKF 11-0355
Mating flange
89.5
430
538
450
361
395
421
150
150
150
150
ZLK 01-0355
Automatic back draught
damper
236
205
M
10
10
89.5
361
395
421
ZBS 11-0056
Soaker sheet (for corrugated
roof)
M
10
420
# = inclination up to 45 possible
within 5 steps. Indicate inclination
with type when ordering ZBS 09- ZLK 21-0355
0031-05 (od. 10, 15, 20, 25, 30, 35, Automatic back draught
damper
40, 45)
When using damper ZLK and upstand
258
9.5
silencer ZDS the damper has to be
fitted by using a plate ZBU below
silencer upstand.
361
When fitting damper to fan an
395
421
intermediate piece ZKK must be
added.
920
11
Voltage
Flow
Speed
rate
Vmax m/h
min-1
9150/7740 1350/1100
6250/5430
930/780
8660
1260
6100
900
12580/9950 1270/960
8990/7790
920/770
V
3x400Y
3x400Y
230
230
3x400Y
3x400Y
Pa
700
WA
82
=8
4d
Absorbed
power
max kW
1,60/1,05
0,52/0,38
1,45
0,54
2,40/1,46
0,82/0,59
DV 71-50-4/4
DV 71-50-6/6
DV 71-50-4E
DV 71-50-6E
Performance Data DV 71
Full load
current
A
3,20/1,80
1,30/0,69
6,3
2,6
4,30/2,4
2,10/1,1
Pa
1 2
3 4
5
6
700
DV 71-56-4/4 1 2
DV 71-56-6/6 3 4
80
500
77
65
67
200
79
68
300
73
72
73
100
83
70
80
69
2
82
73
400 78
Available pressure pfa
74
74
100
m/s
86
m/h
80
78
85
84
80
75
75
71
74
6d
79
79
79
400
=8
600
500
200
LW
600
300
Control units*
Sound Wiring Weight
25steppower diagram
step
step
less LWA Vmax dB No.
kg
DS
D5-7
85/80
515
73
DS
D5-3
75/71
515
64
E5-7
84
509
72
E5-3
75
509
64
DS
D5-12
86/80
516
82
DS
D5-7
78/74
515
71
1step
D1
D1
D1
D1
2000
4000
6000
8000 10000 12000 m/h
0
0,5
2,5
3,0
2,0
1,5
1,0
m/s
Flow rate V
15
21
20
16
17 dB
13
20
25
22
17 dB
Pressure loss
Pressure loss pA through silencer upstand, at flow rates of
5000
8000
10000
Silencer upstand
ZDS..-0071
25
60
95
Intake(LWrel3 = LWoct3 - LWA3 )
Relative sound power level LWrel3 at mid frequencies fm
Duty point
DV 71-50
0,3 Vmax
0,6 Vmax
Vmax
DV 71-56
0,3 Vmax
0,6 Vmax
Vmax
12
63
12000
m/h
110
Pa
Hz
Duty point
63
125 250
500
Hz
15
11
7
9
7
6
2
1
1
-3
-3
-3
-9
-8
-8
-13
-11
-11
-14
-12
-12
-19
-15
-12
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
6
1
-2
5
5
4
1
0
1
-4
-5
-3
-5
-6
-6
-9
-8
-10
-12
-10
-12
-18
-16
-14
dB
dB
dB
13
7
4
9
9
9
4
4
3
-3
-4
-3
-9
-8
-8
-14
-12
-12
-15
-14
-14
-22
-18
-15
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
8
-1
-4
5
7
6
0
-1
-1
-4
-4
-3
-5
-5
-5
-9
-8
-9
-13
-11
-14
-19
-18
-16
dB
dB
dB
Dimensions DV 71
Mains lead
DV 71
ZDH 20-0450
Discharge silencer
222
740
48
M8
6
M8
750
1103
14
1016
ZBS 20-0071
Flat roof upstand
ZKK 20-0071
Intermediate piece
705
590
ZBU 01-0071-45
Connecting plate
M12
453
6M8
14
590
700
487
710
1020
988
M
12
ZDS 20-0071
Silencer upstand
688
590
ZKE 11-0450
Intake flexible connection
580
650
ZBS 23-0071
Flat roof upstand high
69.5
688
590
988
453
487
513
ZDS 09-0071-#
Silencer upstand for inclined roof
688
590
988
ZBS 09-0071-#
Upstand for inclined roof
ZKF 11-0450
Mating flange
69.5
580
688
590
453
487
513
150
150
ZLK 01-0450
Automatic back draught
damper
69.5
M
10
12
150
150
453
487
513
M
10
560
# = inclination up to 45 possible
within 5 steps. Indicate inclination
with type when ordering ZBS 09- ZLK 21-0450
0031-05 (od. 10, 15, 20, 25, 30, 35, Damper with actuator
40, 45)
300
When using damper ZLK and upstand
9.5
silencer ZDS the damper has to be
fitted by using a plate ZBU below
silencer upstand.
453
487
When fitting damper to fan an
513
intermediate piece ZKK must be
added.
282
ZBS 11-0071
Soaker sheet (for corrugated
roof)
1400
13
Absorbed
power
max kW
1,30/0,88
2,50/1,50
3,4
1,6
4,4/0,7
Performance Data DV 90
Full load
current
A
2,9/1,7
5,0/2,8
6,5
3,3
8,7/2,6
Pa
DV 90-63-6/6 1 2
= 81
Control units*
Sound Wiring Weight
25steppower diagram
step
step
less LWA Vmax dB No.
kg
DS
D5-7
81/76
515
119
DS
D5-12
85/79
516
139
86
502
140
D5-7
78
534
135
88/70
551
166
1step
D1
D1
D1
-
LW
dB
=8
DV 90-71-6/6 1 2
4d
500
400
78
75
74
79
400
300
200
78
200
72
100
73
82
300
69
76
100
Flow rate V
4000
6000
8000
10000
2,5
2,0
1,5
1,0
Pa
m/s
Flow rate V
m/h
m/s
DV 90-75-6
1
2
DV 90-75-8
DV 90-75-6/12 3 4
LW
=
90
700
12000 m/h
3,0
85
2000
0,5
79
81
76
dB
88
600
87
500
Attenuation values
Average
Values
Discharge silencer
ZDH 20-0560 11 dB
Silencer upstand
ZDS..-090 15 dB
86
84
300
77
200 72
76
69 4
69
100
1,0
Flow rate V
8000
2,0
12000
3,0
16000
4,0
86
4000
0
20000 m/h
6,0 m/s
5,0
14
13
17
18
18
17 dB
11
17
21
19
13 dB
Pressure loss
Pressure loss pA through silencer upstand, at flow rates of
10000
15000
20000
Silencer upstand
ZDS..-0090
20
40
80
88
70
78
80
400
85
30000
m/h
180
Pa
Hz
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
9
9
6
7
8
7
-2
-1
-1
-1
-3
-1
-6
-6
-7
-10
-8
-9
-14
-12
-13
-21
-21
-24
dB
dB
dB
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
8
10
7
9
9
9
-3
-3
-2
-2
-3
-2
-7
-6
-7
-9
-9
-9
-13
-12
-13
-18
-18
-19
dB
dB
dB
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
8
9
12
4
2
6
-1
-3
0
-5
-5
-4
-8
-7
-7
-8
-7
-8
-8
-8
-12
-12
-14
-17
dB
dB
dB
Hz
Dimensions DV 90
DV 90-63 / DV 90-71
ZDH 20-0560
Discharge silencer
Mains lead
1183
317
DV 90-75
Mains lead
0
M1
8
75
1
M1
8
60
M10
945
1388
317
14
14
1556
ZBS 01-0090
Flat roof upstand
ZBU 01-0090-56
Connecting plate
ZKK 20-0090
Intermediate piece
895
750
569
M12
ZBU 01-0090-71
Connecting plate
8M10
715
8M10
14
750
886
900
1210
605
751
1178
1178
M
12
ZDS 20-0090
Silencer upstand
878
750
ZKE 11-0560
Intake flexible connection
770
900
ZBS 23-0090
Flat roof upstand high
811.5
811.5
878
750
569
605
639
1178
ZDS 09-0090-#
Silencer upstand for inclined roof
878
750
1178
ZBS 09-0090-#
Upstand for inclined roof
ZKE 11-0710
Intake flexible connection
715
751
785
ZKF 11-0710
Mating flange
ZKF 11-0560
Mating flange
811.5
811.5
770
569
605
639
878
750
150
150
10
ZLK 01-0560
Automatic back draught
damper
811.5
ZLK 01-0710
Automatic back draught
damper
811.5
M
12
150
150
715
751
785
569
605
639
10
ZLK 21-0710
Damper with actuator
437
415
11.5
300
720
# = inclination up to 45 possible
within 5 steps. Indicate inclination
with type when ordering ZBS 09- ZLK 21-0560
0031-05 (od. 10, 15, 20, 25, 30, 35, Damper with actuator
40, 45)
When using damper ZLK and upstand
360
11.5
silencer ZDS the damper has to be
fitted by using a plate ZBU below
silencer upstand.
569
When fitting damper to fan an
605
639
intermediate piece ZKK must be
added.
343
ZBS 11-0090
Soaker sheet (for corrugated
roof)
715
751
785
719
751
785
1400
15
Flow
rate
Vmax m/h
24800
17600
125-80-6/12 3x400YY/Y
24800/12470
125-90-6 * 3x400Y
34550
Speed
min-1
945
660
960/480
940
Absorbed
power
max kW
5,2
2,0
5,5/0,85
8,8
Full load
current
A
10,2
4,4
11,0/3,3
16,4
1step
D1
-
Control units*
Sound Wiring Weight
25steppower diagram
step
step
less LWA Vmax dB No.
kg
90
549
215
D5-12
81
537
206
90/72
551
215
94
549
238
Pa
LWA = 9
Pa
DV 125-80-6
1
2
DV 125-80-8
DV 125-80-6/12 1 3
1 dB
700
900
LWA = 9
DV 125-90-6 1
4 dB
800
85
600
500
600
400 82
400
87
76
2
91
500
300
300
200 73
67
200
100
15000
4,0
20000
m/h
6,0 m/s
5,0
100
94
90
5000
10000
0
2,0
3,0
1,0
Flow rate V
81
72
88
700
13
17
18
18
17 dB
14
20
25
23
11 dB
Pressure loss
Pressure loss pA through silencer upstand, at flow rates of
17000
20000
25000
30000
Silencer upstand
ZDS..-0125
20
30
40
65
Intake(LWrel3 = LWoct3 - LWA3 )
Relative sound power level LWrel3 at mid frequencies fm
Duty point
DV 125-80
0,3 Vmax
0,6 Vmax
Vmax
DV 125-90
0,3 Vmax
0,6 Vmax
Vmax
16
63
40000
m/h
110
Pa
Hz
Duty point
63
125 250
500
Hz
15
13
10
7
7
7
3
3
4
-4
-4
-4
-6
-7
-8
-11
-11
-11
-13
-12
-12
-20
-19
-19
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
8
10
7
9
9
9
-3
-3
-2
-2
-3
-2
-7
-6
-7
-9
-9
-9
-13
-12
-13
-18
-18
-19
dB
dB
dB
15
13
10
7
7
7
3
3
4
-4
-4
-4
-6
-7
-8
-11
-11
-11
-13
-12
-12
-20
-19
-19
dB
dB
dB
0,3 Vmax
0,6 Vmax
Vmax
8
10
7
9
9
9
-3
-3
-2
-2
-3
-2
-7
-6
-7
-9
-9
-9
-13
-12
-13
-18
-18
-19
dB
dB
dB
Dimensions DV 125
Mains lead
DV 125
ZDH 20-0710
Discharge silencer
445
1183
75
1
0
M1
8
M10
1270
1769
14
1556
ZBS 20-0125
Flat roof upstand
ZKK 20-0125
Intermediate piece
1205
1050
ZBU 01-0125-71
Connecting plate
715
M12
8M10
14
1050
1235
751
1210
1520
1500
M
12
ZDS 20-0125
Silencer upstand
1226
1050
ZKE 11-0710
Intake flexible connection
1117
ZBS 23-0125
Flat roof upstand high
811.5
1226
1050
1526
715
751
785
ZDS 09-0125-#
Silencer upstand for inclined roof
1226
1050
1526
ZKF 11-0710
Mating flange
1117
ZBS 09-0125-#
Upstand for inclined roof
811.5
1226
1050
715
751
785
150
150
150
150
ZLK 01-0710
Automatic back draught
damper
M
10
811.5
715
751
785
415
300
# = inclination up to 45 possible
within 5 steps. Indicate inclination
with type when ordering ZBS 09- ZLK 21-0710
0031-05 (od. 10, 15, 20, 25, 30, 35, Damper with actuator
40, 45)
When using damper ZLK and upstand
437
silencer ZDS the damper has to be
11.5
fitted by using a plate ZBU below
silencer upstand.
When fitting damper to fan an
719
751
intermediate piece ZKK must be
785
added.
17
Type
Main Control
Voltage voltage
Max.
rating
Max.
Current
Weight Protection
Type
D1
400 V
230 V
3 kW
0,9 kg
IP 54
D1
105
170
135
DS
400 V
230 V
4 kW
0,9 kg
IP 54
DS
105
170
135
D5-1
400 V
230 V
1A
4,5 kg
IP 40
D5-1
150
200
175
D5-3
400 V
230 V
2A
7,0 kg
IP 20
D5-3
230
310
185
D5-7
400 V
230 V
4A
9,0 kg
IP 20
D5-7
230
310
185
D5-12
400 V
230 V
7A
19,0 kg
IP 20
D5-12
230
310
185
E5-1
230 V
1,5 A
1,0 kg
IP 40
E5-1
105
170
135
E5-3
230 V
3A
4,0 kg
IP 40
E5-3
150
200
175
Technical Data:
Dimensions:
Type
Voltage
max. Current
Weight
Protection
Type
ES-3
230 V
2,5 A
0,6 kg
IP 44
ES-3
80
65
Technical Data:
Dimensions:
Type
Voltage
max. Current
Weight
Protection
Type
E2-6
230 V
6A
0,15 kg
IP 54
ES-3
80
77
1
2
18
2-step-switch
2-step-switch DS
For star/delta winding
On/Off Switch D1
For single speed operation
Room thermostat
U1
W2
11
V1
U2
PE
W1
V2
12
U1
W2
11
V1
U2
PE
W1
V2
12
0
1
2
12 11 10 9 8 7 6 5 4 3 2 1
U1 V1 W1 W2 U2 V2 TK TK R1 R2 5 PE
230V; 50Hz
L1 N PE
F1
3,15A
F1
3,15A
U1 V1 W1
S1
L1
L2
L3
S1
R2
14
K1
2 4 6 10 8 12
13
0 1
V1
R2
K1
L1
L2
L3
Isolator switch
DV-30-2/2e
Isolator switch
DV-40-4/4e
L1
L2
L3
N
PE
5-step-switch
E5-1, E5-3
Fan motor
with thermo-contact
11
W2 U2 V2
12
U1 V1 W1
21 A1
22 A2
Jumper as
per motor
nameplate
to the outside
Fan motor
11 12 CZ2 U1Z1CU2 PE
PE N
L1 R1 R2 PE N VM
PE
11
K1
S1
H2
F1
10 12
Control
10 12 Thermo-contacts
8 6
2 6
Step-less controller
ES-3 (phase cutting)
L1
N
PE
PE N L1 L2 L3 TK TK PE U1 V1 W1 R2 R1
2
4
L1
L2
L3
N
PE
5-step-switch
D5-1, D5-3, D5-7, D5-12
L1
L2
L3
N
PE
4
8
2,5A
0 5 4 3 2 1
S1
H1
0 5 4 3 2 1
23
24
7
3
9
5
1
4
5
4
3
2
1
400 V
280 V
230 V
180 V
140 V
1
2
3
4
5
140 V
180 V
230 V
280 V
400 V
T1
0
0
16
13
17
21
15
19
(11)
(12)
1
2
(7)
(3)
(9)
(5)
(1)
(4)
11
9
7
5
3
4
5
4
3
2
1
0
230 V
160 V
145 V
130 V
105 V
L L 1 NN
T1
T2
1
* Remove jumper if room thermostat is connected
non-controlled connection
controlled connenction
Phase
T
T
L3
L1
L2
HiS
HiS
HiO
HiO
PE
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
white
white
grey
red
orange
black
blue
brown
green-yellow
T
T
V2
U2
W2
W1
V1
U1
PE
L1
brown
black
brown
HiS
HiS
HiO
HiO
PE
Motor
-circuit 400 V
502
blue
blue
green-yellow
Z
U2
U1
PE
Motor
capacitor
17-09-04
507
19
L1
N
HiS
HiS
HiO
black
blue
T
T
L1
N
HiS
HiS
HiO
HiO
PE
orange
Z2
Z1
U2
brown
U1
green-yellow
PE
PE
Mains isolator switch
Motor
cpacitor
L3
L2
L1
HiS
HiS 21
HiO 23
HiO
PE
2
4
6
8
10
12
14
16
18
white
white
grey
red
orange
black
blue
brown
green-yellow
T
T
V2
U2
W2
W1
V1
U1
22
24
T
T
L3
L2
L1
HiS
HiS
HiO
HiO
PE
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
21
23
22
24
white
white
grey
red
orange
black
blue
brown
green-yellow
T
T
V2
U2
W2
W1
V1
U1
Motor
515
1
3
5
7
9
11
2
4
6
8
10
12
13
15
14
16
Mains Isolator
white
white
grey
red
orange
black
blue
brown
green-yellow
white
white
grey
red
orange
black
blue
brown
green-yellow
T
4
T
6
V2
U2
W2
W1 12
V1 10
U1 8
PE
Motor
Y-Connection 400 V
Motor
Connection 230 V
527
-connection
400V
T
T
20
isolator switch
Motor
=green/yellow
U1-V1-W1 = brown
W2-U2-V2 = blue
T
= white
17-09-04
Motor
capacitor
509
17-09-04
T
T
1
3
5
7
9
11
13
15
17
L3
L1
L2
HiS
HiS 21
HiO 23
HiO
PE
2
4
6
8
10
12
14
16
18
22
24
white
white
grey
red
orange
black
blue
brown
green-yellow
T
T
V2
U2
W2
W1
V1
U1
T
T
L3
L1
L2
HiS
HiS
HiO
HiO
PE
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
21
23
22
24
white
white
grey
red
orange
black
blue
brown
green-yellow
T
T
V2
U2
W2
W1
V1
U1
Motor
21-09-04
516
T
T
L2
L1
L3
HiS
HiS
HiO
HiO
PE
1
3
5
7
9
11
2
4
6
8
10
12
13
15
14
16
white (grey)
white
T
T
black
blue
brown
green-yellow
W1
V2
V1
U2
U1
W2
PE
Motor
-connection
400V
17-09-04
537
U1
W2
V1
U2
W1
V2
PE
black
Z1
blue
U2
brown
U1
green-yellow
PE
T
T
V2
U2
W2
W1
V1
U1
PE
05-08-02
Mains
14
16
T
T
Z2
17-09-04
T
T
L2
L1
L3
HiS
HiS
HiO
HiO
PE
13
15
white
white
orange
508
1
3
5
7
9
11
13
15
17
2
4
6
8
10
T
T
1
3
5
7
9
white
HiO
549
T
T
3
5
L3
L1
L2
HiS
HiS
HiO
HiO
PE
13
15
17
22
21
23
24
Mains
lower speed
T
T
L3
L1
L2
HiS
HiS
HiO
HiO
PE
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
21
23
22
24
white
white, pink
blue
blue
blue
brown
brown
brown
green-yellow
T
T
2W
2V
2U
1W
1V
1U
PE
Motor
17-09-04
551
The control unit DigiPro is a system for controlling and monitoring a ventilation installation.
DigiPro is fully set and ready for connection.
The smallest unit is equipped with a manual control panel and a second part serving as master
controller.
These components are connected by bus (eBus) in a 2-wire technology.
There up to 32 units can be integrated in the same bus-system (with always one master or group
unit).
2 master units are available for the control and monitoring of exhaust fans and other units
equipped with a 230V or 400V fan motor, 2-speed or continuous speed variation.
Description
The handling of the unit is simple. The control parameters are set making it ready for connection
and operation.
There is no programming necessary.
If communication with mobile phone is required an ISDN-interface can be added.
In case of operational troubles messages can be mailed to the phone, fax or to a PC, providing a
constant monitoring of the ventilation installation.
Further on a LON-Interface is available for integrating it into a LON-field-bus-system thus
overcoming system limits in a building.
Stylish casing made of cast aluminium; fitted outside fan unit
Integrated isolator switch
Input: 4 x trouble messages
Output: 1 relay connection 230VH, Relay exit potential free, 1 analogue output
Power electronics for motor speed control
Integrated motor temperature monitoring
Address can be set with DIP-switch
Short motor circuit recognition
Radio noise suppression integrated (230V~ execution)
2-wire bus for system integration
Standart functions
Signal in
(analogue)
Command in/out
(digital)
Command continuous
(anal)
Filter control
Free
Damper open/close
Fire detection
Free
Free
thermo-contact
Technical Data
Protection:
Feed voltage; Rating FAE:
Feed voltage; Rating FAZ:
Sourrounding conditions:
Storage temperature:
Operation altitude:
Wire section for tapping:
Input digital:
Output digital:
Output analogue:
Motor connection to FAE:
motor connection to FAZ:
Feed fuses:
Dimensions L x B x H:
Remark:
IP54
230V~ 10% / 50 Hz / 2,2kW
400V~ 10% / 50 Hz / 2,2kW
Temperature: -20 bis +50C
Air humidity 0 bis 95%
-25 bis + 65C
max. 2000m
max. 2,5mm (coloured plugs coded)
4x 24V=
1x relay 230V~ /2A / AC3
1x 0..10V DC
0-230V~ / 50Hz / max. 11,5A / continuous speed control,
max. 2,2kW for common motor ctrl.
400V~ / 50Hz / max. 3x6,5A / 2-speed control,
max. 2,2kW for common motor control.
10/16 A (not included)
33,7 cm x 21,7 cm x 12,2 cm
Exhaust air management (e.g. under- or over pressure, exhaust air in function of supply air or
parallel operation with supply air) is only possible in connection with a master unit of a supply
air fan. An independent control with DigiPro is not possible.
21
Sample Specification
with swirl free horizontally directed discharge, for maximum gas medium temperatures
up to +40C.
Stylish casing and base frame with inlet cone, manufactured from galvanised sheet steel.
Inlet flange in accordance with DIN 24 155- 2.
Discharge outlets protected from the weather with an aerodynamically shaped grille.
Centrifugal impeller with backward curved blades, mounted on the rotor of a variable
speed integral external rotor motor, protected to IP 44.
Motor protection is through direct switching of thermo-contacts in the motor winding,
supplied ready to connect.
Dynamically balanced, installed vibration free, totally maintenance free.
Fan type
Flow rate
Pressure increase
Temp. of gas medium
Speed
Shaft power
Max. absorbed current
voltage/ frequency
A-Sound power level
Weight
Dimensions
22
DV
V
pfa
t
n
max. P1
max. I
U/f
LWA
G
=
=
=
=
=
=
=
=
=
=
=
...........................
........................... m/h
........................... Pa
........................... C
........................... 1/min
........................... kW
........................... A
........................... V / Hz
........................... dB
........................... kg
........................... mm
Summary ...................................................................................................................Page
Roof Ventilation Hoods DLH
Product review .......................................................................................................................... 24
Dimensions................................................................................................................................. 24
Pressure drops Intake - exhaust ............................................................................................ 24
Dimensions of accessories ..................................................................................................... 25
Smoke Extract Fans ER
Product review .......................................................................................................................... 26
Summary data sheet ................................................................................................................ 27
Gerneral instructions ...................................................................................................... 28 - 29
RDM 56/57-25.. - Performances / Dimensions ........................................................ 30 / 31
RDM 56/57-35.. - Performances / Dimensions ....................................................... 32 - 33
RDM 56/57-45.. - Performances / Dimensions ....................................................... 34 - 35
RDM 56/57-56.. - Performances / Dimensions ....................................................... 36 - 37
RDM 56/57-71.. - Performances / Dimensions ........................................................ 38 - 39
RDM 56/57-90.. - Performances / Dimensions ....................................................... 40 - 41
Isolator switch ........................................................................................................................... 42
Dimensions of accessories ..................................................................................................... 43
Sample specification ................................................................................................................ 44
23
Description
Dimensions
e
c
a
DLH 40
671
440
440
32
6M6
330
12
286
DLH 56
881
523
600
32
8M8
450
12
395
DLH 71
1103
648
750
32
6M8
590
14
487
DLH 90
1388
822
940
40
8M10
750
14
605
DLH 125
1769
933
1270
65
8M10 1050 14
751
12
90
DL
H
DL
H
56
71
DL
H
Pressure loss pA
DL
H
40
DL
H
12
DL
H
71
56
90
DL
H
DL
H
DL
H
40
DL
H
100
Pressure loss pA
100
1000
Pa
1000
Pa
10
1000
Flow rate V
10000
m/h
10
1000
Flow rate V
10000
m/h
Dimensions accessories
a
b
ZBS 200040
0056
0071
0090
0125
f
a1
d
24
a
395
555
705
895
1205
a1
400
560
710
900
1210
b
330
450
590
750
1050
d
710
870
1020
1210
1520
f
M10
M10
M12
M12
M12
kg
8
10
16
25
34
b1
ZBS 230040
0056
0071
0090
0125
a
378
538
688
878
1226
b
330
450
590
750
1050
b1
650
800
900
900
900
d1
618
778
988
1178
1526
f
M10
M10
M12
M12
M12
kg
12
14
20
32
40
d1
d11
a
b
ZBS 090040-#
0056-#
0071-#
0090-#
0125-#
a
378
538
688
878
1226
b
330
450
590
750
1050
d11
618
778
988
1178
1526
f
M10
M10
M12
M12
M12
g
250
250
250
250
250
h
150
150
150
150
150
kg
5
6
9
13
18
# = inclination up to 45 possible within 5 steps. Indicate inclination with type when ordering
ZBS 09-0031-05 (od. 10, 15, 20, 25, 30, 35, 40, 45)
b
330
450
450
750
c
200
200
200
200
d
920
920
1400
1400
f
M10
M10
M12
M12
g
1600
1600
2000
2000
h
322
400
560
715
ZBS 110040
0056
0071
0090
DLH
DLH
DLH
DLH
DLH
40
56
71
90
125
ZKE
11-0250
11-0355
11-0450
11-0560
11-0710
DLH
DLH
DLH
DLH
DLH
40
56
71
90
125
ZKF
11-0250
11-0355
11-0450
11-0560
11-0710
DLH
DLH
DLH
DLH
DLH
40
56
71
90
125
ZLK
21-0250
21-0355
21-0450
21-0560
21-0710
zd
a
b
c
zd
a
b
c
d4
a
b
c
a
256
361
453
569
715
a
256
361
453
569
715
a
256
361
453
569
715
b
286
395
487
605
751
b
286
395
487
605
751
b
286
395
487
605
751
c
306
421
513
639
785
c
306
421
513
639
785
c
306
421
513
639
785
d4
88
88
88
88
88
e
240
240
240
240
300
z x d
6 x 7
8 x 9,5
6 x 9,5
8 x 11,5
8 x 11,5
e
25
30
30
35
35
f
185
237
282
343
415
z x d
6 x 7
8 x 9,5
6 x 9,5
8 x 11,5
8 x 11,5
k
207
258
300
360
437
z x d
6 x 7
8 x 9,5
6 x 9,5
8 x 11,5
8 x 11,5
25
Description
26
Flow
rate
Available
pressure
Voltage
Speed
Motor
rating
Rated
current
Weight
Isolator
switch
RDM 56/57-
m/h
Pa
1/min
kW
kg
ESH 23
2528-2D-11
3.300
950
230/400 /Y
2845
1.10
4.15/2.40
39
0055-32
2531-4D-10
2.200
270
230/400 /Y
1395
0.55
2.51/1.45
35
0055-32
3535-4D-10
3.370
320
230/400 /Y
1395
0.55
2.51/1.45
44
0055-32
3540-4D-10
4.700
440
230/400 /Y
1395
0.55
2.51/1.45
50
0055-32
3545-4D-13
5.750
570
230/400 /Y
1410
1.1
4.6/2.65
55
0055-32
3545-HD-10
3.700 /1.900
215/50
400 Y/YY
935/425
0.3/0.075
1.0/0.44
55
0075-62
4550-4D-16
9.450
650
230/400 /Y
1420
2.20
8.50/4.90
87
0055-32
4550-HD-14
6.200 /3.000
280/70
400 Y/YY
965/460
0.55/0.12
2.0/0.88
82
0075-62
4556-4D-17
11.400
800
230/400 /Y
1420
3.0
11.1/6.4
100
0055-32
4556-6D-13
7.300
320
230/400 /Y
915
0.75
3.65/2.1
94
0055-32
4556-HD-16
7.300/3.750
320/100
400 Y/YY
940/460
1.1/0.18
2.85/1.09
103
0075-62
5663-6D-16
11.900
470
230/400 /Y
925
1.5
6.75/3.9
181
0055-32
5663-HD-19
11.900/5.900
470/130
400 Y/YY
955/450
1.8/0.45
5.1/2.0
199
0075-62
5671-6D-21
14.500
620
230/400 /Y
950
12.5/7.2
190
0055-32
5671-HD-24
14.500/7.400
620/160
400 Y/YY
965/480
3.3/0.7
6.8/2.5
216
0075-62
7180-6D-24
25.000
780
400/690 /Y
950
5.5
12.8/7.4
288
0075-62
7180-8D-21
18.800
440
230/400 /Y
700
2.2
9.9/5.7
300
0055-32
7180-HD-28
25.000/12.000
780/180
400 Y/YY
975/485
6.2/1.3
12.5/4.1
348
0075-62
7190-6D-28
33.500
980
230/400 /Y
960
9.0
19.4/11.2
297
0110-62
7190-HD-26
33.500/15.800
980/240
400 Y/YY
975/485
9.0/2.0
18.5/6.2
390
0110-62
9090-4D-31
51.900
2000
400/690 /Y
1460
22
41.5/24.1
590
0220-62
9090-ID-34
57.200/38.200
2.200/1.000
400 Y/Y
1470/980
26/9.5
49.0/20.0
640
0300-62
9090-GD-34
57.200/28.800
2.200/590
400 Y/YY
1470/732
28/7.5
52.0/20.5
640
0300-62
27
Important Remarks
Safety Guards
All roof extract fans are supplied with a discharge-side mesh safety guard in accordance
with DIN EN 294. The inlet side is not fitted with a standard guard, because it is normal
practice to connect other system parts to this end. However, if the unit is installed in
such a way that accidental contact with the impeller is possible, an additional inlet
guard has to be fitted acc. to DIN EN 294! The fans may only be put into operation if
all necessary protection devices are fitted and made effective (see maintenance
instructions)! The safety guards are to be executed acc. to DIN EN 292 1, chapter 3.22
Separating safety devices and DIN EN 292 2, chapter 4 Technical protection measures.
Safety instructions
Transport, fitting, electrical connection, start up, and maintenance are to be executed
following the instructions given in the manual and by respecting the actual standards,
guide lines, and safety rules. Please take care of the special heat protected
cable lead when installing smoke extract fans.
Performance data
The performance curves are obtained using an inlet side test chamber in accordance with
DIN 24 163-2 Fans, performance tests, standard test equipment. The performance grids
show the effective pressure increase pfa (Pressure increase obtained from the fan in
free-field conditions) as a function of the flow volume VL.
Reference media density: 1 = 1.15 kg/m. The roof fans comply with the tolerances of
Class 2 of DIN 24 166 Fans, Technical Specifications.
28
Important Remarks
Measurement and evaluation of noise levels are in accordance with DIN 45 635 - 38
Sound measurements on machines; fans. In the technical data the A-weighted sound
power level at maximum flow rate is given.
The computer aided data collection and evaluation enables to obtain highly reliable data
precision. In the curves the emission value of the A-sound-power level LWA is given,
having the same value for intake (LWA3) as for the discharge (LWA8).
For more exact calculations when determining the required attenuation, the sound power
level in the octave bands is important.
LWoct 3/8= LWA + LWrel 3/8
The relative sound power levels for inlet and discharge sides, at various duty points, can be
read from the corresponding tables.
Calculation of the sound pressure level Because conditions in the operating environment are usually far from ideal for
measurement and can vary greatly, a determination of the A-sound-pressure level at any
distance is only possible with great uncertainty.
LPA LWA L
The diagram below supplies the correction value L in function of the distance r from
the fan centre. Under ideal conditions, with a clear hemisphere of sound propagation,
curve a is valid. However, curve b is recommended for practical estimates. The
calculation of the intake sound-power level is only possible if the exact noise parameters
of the connected room are known (see VDI 2081!).
30
dB
a
b
20
10
m 10
29
Technical Data
Smoke extract
fan ER
RDM 56/572528-2D-11
Flow
rate
m/h
3.300
Available
pressure
Pa
950
Voltage
Speed
V
230/400 /Y
2531-4D-10
2.200
270
230/400 /Y
Pa
LW
A=8
8d
RDM 50-2528-2D-11
= Vopt
Rated
current
A
4.15/2.40
Weights
1/min
2845
Motor
rating
kW
1.10
kg
39
Isolator
switch
ESH 23
0055-32
1395
0.55
2.51/1.45
35
0055-32
Pa
280
RDM 50-2531-4D-10
= Vopt
800
LW
A=
72
240
600
dB
200
86
160
500
0
0,1
0,2
Flow rate V
1000
0,3
1500
0,4
2000
0,5
0,6
2500
0,7
3000 m/h
0,8
m/s
200
88
120
87
400
80
40
500
0
0,1
Flow rate V
1000
0,2
0,3
1500
0,4
2000
0,5
m/h
0,6 m/s
In the curves the A-weighted sound power level is LWA (=LWA3 =LWA8) acc. to DIN 45635-38.
Reference media density: 1 = 1.15 kg/m.
Intake
Relative sound power level LWrel3 at octave mid frequencies fm
Discharge
Relative sound power level LWrel3 at octave mid frequencies fm
30
Hz
dB
dB
dB
Hz
dB
dB
dB
500
-2
-3
-2
Hz
dB
dB
dB
500
-3
-3
-3
Hz
dB
dB
dB
Dimensions
Dimensions
600
559
6
28
330
32
440
440
ZBS 03-0040
(600C)
12
6xM6
ZBS 20-0040
For RDM56 only, when connected to duct
395
330
283
283
395
330
400
710
350
710
10
10
6x7
Inlet guard
ZSG 04-0250
130
67
256
286
306
25
378
330
270
115
650
256
286
306
115
618
340
6x7
M
10
Mating flange
ZKF 11-0250 (600C)
256
286
306
31
Technical Data
Smoke extract
fan ER
RDM 56/573535-4D-10
Flow
rate
m/h
3.370
Available
pressure
Pa
320
Voltage
Speed
V
230/400 /Y
3540-4D-10
3545-4D-13
4.700
5.750
440
570
3545-HD-10
3.700 /1.900
215/50
Pa
300
Rated
current
A
2.51/1.45
Weights
1/min
1395
Motor
rating
kW
0.55
kg
44
Isolator
switch
ESH 23
0055-32
230/400 /Y
230/400 /Y
1395
1410
0.55
1.1
2.51/1.45
4.6/2.65
50
55
0055-32
0055-32
400 Y/YY
935/425
0.3/0.075
1.0/0.44
55
0075-62
Pa
RDM 50-3535-4D-10
= Vopt
LW
A = 74
dB
450
400
250
RDM 50-3540-4D-10
= Vopt
LW
A=
79
dB
350
72
300
200
73
150
100
50
75
500
1000
0
0,1 0,2 0,3
Flow rate V
2500
1500
2000
0,4 0,5 0,6 0,7
250
3000 m/h
0,8
m/s
200
150
100
50
0
1000
0
0,2
2000
3000
0,8
0,6
0,4
m/h
4000
1,2 m/s
1,0
Flow rate V
Pa
L
W
A=
500
85
RDM 50-3545-4D-13 1
RDM 50-3545-HD-10 2 3
= Vopt
dB
1
400
82
82
72
200
70
100
71
83
72
300
1000
0
2000
0,5
3000
4000
5000
1,0
m/h
1,5 m/s
Flow rate V
Intake
Relative sound power level LWrel3 at octave mid frequencies fm
Discharge
Relative sound power level LWrel3 at octave mid frequencies fm
32
Hz
dB
dB
dB
Hz
dB
dB
dB
Hz
dB
dB
dB
Hz
dB
dB
dB
Dimensions
Dimensions
770
709
5
39
450
32
600
ZBS 03-0056
(600C)
600
12
ZBS 20-0056
For RDM56 only, when connected to duct
555
450
283
283
555
450
510
870
560
870
10
89.5
361
395
421
361
395
421
8x9,5
30
Mating flange
ZKF 11-0355 (600C)
10
Inlet guard
ZSG 04-0355
8x9,5
130
8xM8
361
395
421
538
450
430
800
115
115
500
10
778
M
33
Technical Data
Smoke extract
fan ER
RDM 56/574550-4D-16
Flow
rate
m/h
9.450
Available
pressure
Pa
650
Voltage
Speed
V
230/400 /Y
4550-HD-14
4556-4D-17
6.200 /3.000
11.400
280/70
800
4556-6D-13
4556-HD-16
7.300
7.300/3.750
320
320/100
Pa
LW
A=8
7
600
Rated
current
A
8.50/4.90
Weights
1/min
1420
Motor
rating
kW
2.20
kg
87
Isolator
switch
ESH 23
0055-32
400 Y/YY
230/400 /Y
965/460
1420
0.55/0.12
3.0
2.0/0.88
11.1/6.4
82
100
0075-62
0055-32
230/400 /Y
400 Y/YY
915
940/460
0.75
1.1/0.18
3.65/2.1
2.85/1.09
94
103
0055-32
0075-62
Pa
dB
1
500
LW
A=
94
dB
800
700
85
RDM 50-4556-4D-17 1
RDM 50-4556-6D-13 2
RDM 50-4556-HD-16 2 3
= Vopt
1
600
400
90
87
75
74
200
74
100
57
3 56
Flow rate V
4000
1,0
6000
8000
2,0
m/h
m/s
79
200
63
100
3 6
1
2000
0
4000
1,0
91
2000
82
300
80
88
75
57
400
62
300
500
6000
8000
2,0
10000
3,0
m/h
m/s
Flow rate V
Intake
Relative sound power level LWrel3 at octave mid frequencies fm
Discharge
Relative sound power level LWrel3 at octave mid frequencies fm
34
Hz
dB
dB
dB
Hz
dB
dB
dB
500
-4
-5
-4
Hz
dB
dB
dB
500
-4
-4
-3
Hz
dB
dB
dB
Dimensions
Dimensions
985
794
7
48
590
32
750
ZBS 03-0071
(600C)
750
14
ZBS 20-0071
For RDM56 only , when connected to duct
705
590
283
283
705
590
660
1020
710
1020
12
12
Inlet guard
ZSG 04-0450
6x9,5
130
69.5
453
487
513
453
487
513
6x9,5
30
Mating flange
ZKF 11-0450 (600C)
6xM8
453
487
513
688
590
580
900
115
115
650
12
988
35
Technical Data
Smoke extract
fan ER
RDM 56/575663-6D-16
Flow
rate
m/h
11.900
Available
pressure
Pa
470
Voltage
Speed
V
230/400 /Y
5663-HD-19
5671-6D-21
11.900/5.900
14.500
470/130
620
5671-HD-24
14.500/7.400
620/160
Pa
450
LW
A=
8
3d
Rated
current
A
6.75/3.9
Weights
1/min
925
Motor
rating
kW
1.5
kg
181
Isolator
switch
ESH 23
0055-32
400 Y/YY
230/400 /Y
955/450
950
1.8/0.45
3
5.1/2.0
12.5/7.2
199
190
0075-62
0055-32
400 Y/YY
965/480
3.3/0.7
6.8/2.5
216
0075-62
Pa
RDM 50-5663-6D-16 1
RDM 50-5663-HD-19 1 2
= Vopt
400
600
350
RDM 50-5671-6D-21 1
RDM 50-5671-HD-24 1 2
= Vopt
LW
A=
89
dB
1
500
81
88
300
400
200
150
65
100
63
50
83
65
250
2000
0
Flow rate V
4000
1,0
6000
8000
10000
2,0
3,0
m/h
m/h
300
200
71
69
100
88
70
0
2000
4000
6000
0
1,0
Flow rate V
8000
2,0
10000 12000
m/h
3,0
m/s
Intake
Relative sound power level LWrel3 at octave mid frequencies fm
Discharge
Relative sound power level LWrel3 at octave mid frequencies fm
36
Hz
dB
dB
dB
500
-3
-4
-4
Hz
dB
dB
dB
Dimensions
Dimensions
1225
1004
5
60
750
40
940
ZBS 03-0090
(600C)
940
14
ZBS 20-0090
For RDM56 only , when connected to duct
895
750
283
283
895
750
850
D1210
900
1210
12
811.5
569
605
639
569
605
639
8x11,5
35
Mating flange
ZKF 11-0560 (600C)
12
Inlet guard
ZSG 04-0560
8x11,5
130
8xM10
569
605
639
115
878
750
115
900
770
840
12
1178
37
Technical Data
Smoke extract
fan ER
RDM 56/577180-6D-24
Flow
rate
m/h
25.000
Available
pressure
Pa
780
Voltage
Speed
V
400/690 /Y
7180-8D-21
7180-HD-28
18.800
25.000/12.000
440
780/180
7190-6D-28
7190-HD-26
33.500
33.500/15.800
980
980/240
Pa
800
LW
A=
92
700
Rated
current
A
12.8/7.4
Weights
1/min
950
Motor
rating
kW
5.5
kg
288
Isolator
switch
ESH 23
0075-62
230/400 /Y
400 Y/YY
700
975/485
2.2
6.2/1.3
9.9/5.7
12.5/4.1
300
348
0055-32
0075-62
230/400 /Y
400 Y/YY
960
975/485
9.0
9.0/2.0
19.4/11.2
18.5/6.2
297
390
0110-62
0110-62
Pa
RDM 50-7180-6D-24 1
RDM 50-7180-8D-21 2
RDM 50-7180-HD-28 1 3
= Vopt
dB
900
500
500
400
90
82
300
83
3 7
0
93
93
600
84
100
700
89
73
RDM 50-7190-6D-28 1
RDM 50-7190-HD-26 1 2
= Vopt
800
200
4d
600
400
LW
A=
9
300
77
200
75
100
10000
1
2
Flow rate V
15000
4
20000
6
25000
m/h
m/s
77
0
5000
0
10000 15000
1
2
Flow rate V
94
5000
0
91
84
72
20000
5
25000
7
30000 m/h
8
9 m/s
Intake
Relative sound power level LWrel3 at octave mid frequencies fm
Discharge
Relative sound power level LWrel3 at octave mid frequencies fm
38
Hz
dB
dB
dB
Hz
dB
dB
dB
500
-4
-4
-3
Hz
dB
dB
dB
500
-3
-3
-3
Hz
dB
dB
dB
Dimensions
Dimensions
1625
1304
1
75
1050
65
1270
ZBS 03-0125
(600C)
1270
14
ZBS 20-0125
For RDM56 only , when connected to duct
1205
1050
283
283
1205
1050
1160
1520
1210
1520
12
12
Inlet guard
ZSG 04-0710
8x11,5
130
811.5
715
751
785
715
751
785
8x11,5
35
Mating flange
ZKF 11-0710 (600C)
8xM10
715
751
785
115
1226
1050
115
900
1117
1190
12
1526
39
Technical Data
Smoke extract
fan ER
RDM 56/579090-4D-31
Flow
rate
m/h
51.900
Available
pressure
Pa
2000
Voltage
Speed
V
400/690 /Y
9090-ID-34
9090-GD-34
57.200/38.200
57.200/28.800
2.200/1.000
2.200/590
400 Y/Y
400 Y/YY
Pa
2200
LW
A=
11
1d
10
2000
9
1800
Rated
current
A
41.5/24.1
Weights
1/min
1460
Motor
rating
kW
22
kg
590
Isolator
switch
ESH 23
0220-62
1470/980
1470/732
26/9.5
28/7.5
49.0/20.0
52.0/20.5
640
640
0300-62
0300-62
RDM 50-9090-4D-31 2
RDM 50-9090-ID-34 1 3
RDM 50-9090-GD-34 1 4
= Vopt
B
1
1600
1400
10
10 9
7
1200
101
800
600
94
400
0
11
8
10
99
10
4 92
93
94
10000
0
2,5
Flow rate V
20000
5
30000
7,5
10
40000
10
50000
12,5
1
11
200
10
1000
m/h
m/s
Intake
Relative sound power level LWrel3 at octave mid frequencies fm
Discharge
Relative sound power level LWrel3 at octave mid frequencies fm
RDM 56/57-9090
4-poles
Duty point 6 3 125
0.5Vopt 1 5
11
Vopt
11
13
Vmax
7
14
6-poles
Duty point 6 3 125
0.5Vopt 1 5
11
Vopt
11
13
Vmax
7
14
RDM 56/57-9090
4-poles
Duty point 6 3 125
0.5V opt
2
4
V opt
1
4
Vmax
-3
4
6-poles
Duty point 6 3 125
0.5V opt
2
4
V opt
1
4
Vmax
-3
4
40
250
1
-1
3
Hz
dB
dB
dB
250
1
-1
3
Hz
dB
dB
dB
250
1
0
0
500
-4
-4
-3
Hz
dB
dB
dB
250
1
0
0
500
-4
-4
-3
Hz
dB
dB
dB
Dimensions
Dimensions
1800
1275
4
93
1050
65
1276
1276
14
283
283
1205
1050
1160
1520
1160
1520
12
12
12x11,5
130
12xM10
Mating flange
ZKF 11-0900 (600C)
12x11,5
35
898
934
968
898
934
968
Inlet guard
ZSG 04-0900
1211.5
898
934
968
41
KL
L3
1L1
L1
1L2
L2
1L3
HiS
Isolator switches
W2 U2 V2
KL
KL KL U1 V1 W1
1T1 black
1T2 blue
1T3 brown
green /yellow
KL
KL
W2
U2
1L1
1L2
V2
KL KL U1 V1 W1
1T1 black
1T2 blue
1T3 brown
green /yellow
L1
L2
HiS
HiS
13
14
HiS
HiO
21
22
HiO
HiO
HiO
PE
PE
517
1L1
1L2
HiO
HiO
2L1
2L2
2L3
14
13
L3
L1
L2
HiS
21
HiS
HiO
22
HiO
PE
Mains Y
2L1
2L2
1T1 grey
1T2 red
1T3 white
2T1 black
2T2 blue
2L3
2T3 brown
13
14
21
22
42
13
14
21
22
W2 U2 V2
U1 V1 W1
HiS
HiO
22
HiO
green /yellow
PE
green /yellow
Mains
Mains Y
L3
L1
L2
W2 U2 V2
U1 V1 W1
Motor Y/
isolator switch
isolator switch
Motor Y/
543
L3
L1
L2
HiS
HiS
HiO
HiO
PE
Mains
higher speed
KL
KL
HiS
HiS
HiO
HiO
PE
518
2L1
2L2
2L3
14
13
21
22
Mains
L3
L1
L2
HiS
HiS
HiO
HiO
PE
1L1 1T1 2W
1L2 1T2 2V
1L3 1T3 2U
2L1 2T1 1W
2L2 2T2 1V
2L3 2T3 1U
13
21
KL
KL
2U 2V 2W
1U 1V 1W
14
22
green /yellow
Motor Y/YY
544
Mains
lower speed
2L3
21
KL
L3 2L1
L1 2L2
L2 2L3
HiS 14
HiS 13
HiO 21
HiO 22
PE
2T1 W1
2T2 V1
2T3 U1
KL
KL
KL
green / yellow
PE
Mains
L1
L2
HiS
1L1
1L2
1L3
1L3
L1
L2
HiS
HiS
14
13
2L1
2L2
L3
KL
L3
2L3
Motor Y
1L3
1L3
2L1
2L2
L3
1T1 V2
1T2 U2
1T3 W2
1L1
1L2
KL
KL
KL
KL
KL
KL
KL
L3
L1
L2
1L1
1L2
1L3
2U 2V 2W
1U 1V 1W
14
22
green /yellow
isolator switch
Motor Y/YY
519
HiS
HiS
HiO
HIO
PE
14
13
21
22
Mains
lower speed
L3
L1
L2
HiS
HiS
HiO
HIO
PE
1L1
1L2
1L3
2L1
2L2
2L3
13
21
KL
KL
1T1 2W
1T2 2V
1T3 2U
2T1 1W
2T2 1V
2T3 1U
KL
KL
2U 2V 2W
1U 1V 1W
14
22
green /yellow
Motor
545
ESH 23
0055-32
0075-62
0110-62
0220-62
0300-62
A
85
100
100
145
200
B
120
190
190
250
300
C
90
93
93
107
172
D
107
110
110
124
222
Dimensions Accessories
Execution
Clear grey plastic casing (ESH 23-0300-62 in sheet steel) for fitting on the wall. Protection IP 66.
Black handle for positions 0" and I. Cover coupling with integrated locking device.
Clear tapping arrangement. Every switch is equipped with a wiring diagram.
Function
The isolator switch is installed for isolating the smoke extract fan from the mains safely on site
in case of checking, cleaning, or maintenance works. So accidents by uncontrolled switching on
can be avoided and service operations will be eased.
Every isolator switch is provided with potential free contacts (1 open, 1 closed)
Execution
Robust coated sheet steel casing, protection IP 66, (when cooling fan and air filter IP 43) are
integrated. Surrounding temperature up to +40C.
Signals and buttons arranged on the front door.
Function
The switch panel will fulfil the following task in case of fire:
bridge the motor protection
start the fan into highest possible speed (e.g. 2 speed motor)
The switch panel is made for reaction to a signal coming from the optical smoke detector EBS 02.
A button is provided for manual start from the panel.
80
The optical smoke detector recognizes early smouldering as well as open fire with smoke generation.
It is working following the principle of scattered light. Light emitter end sensor are placed in the
sample chamber in a way that the emitter beam cannot directly hit the sensor. Only the light
scattered by smoke (Tyndall-effect) reaches the sensor and generates an electrical signal. The
electronic evaluation system of EBS 02 controls the smoke measuring chamber additionally with
regard to if dust deposit may false the signal. Strong dirt accumulation or a failure in function
are optically shown by EBS 02. A long range alarm threshold value check assures that a sufficiently
wide opening between basic signal and alarm signal will be maintained, until the maximum dirt
accumulation is reached. The alarm threshold signal is set acc. to EN 54-7. An additional
temperature sensor generates an alarm when a temperature above 70C is reached. A relay
contact will inside opens at alarm or current failure.
Execution
The smoke detector is of protection class IP 42acc. to DIN VDE 0470 and equipped with a LED
light signalising operational readiness.
The smoke detector EBS 02 may exclusively be connected to the electronic switch panel EBG.
Fitting base for simple surface mounting of the optical smoke detector EBS 02. Designed for dry
rooms and for the maximum cable diameter of 9 mm. Weight app. 45 g.
33
33
59,5
33
80
4,5
3,7
125
The manual switch ESH 31 is made for starting the smoke extract installation by hand. The actual
state of operation is indicated.
Execution
The manual switch ESH 31 is made for being surface mounted. The casing made of plastic has an
orange colour. Protection class IP 20.
The unit is equipped with 2 buttons, switching voltage 24V, switching current 1A.
38
43
Pcs.
Single price
Total price
RDM 56-2528 ./. 9090, suitable for maximum temperatures up to 400 C - 120 minutes.
RDM 57-2528 ./. 9090, suitable for maximum temperatures up to 600 C - 120 minutes.
Smoke extract fan
Air discharge vertical and swirl free. Tested and certified acc. to EN 12101-3 and certified by DIBt
under the codes Z-78.1-26/Z-78.1-27.
Stylish and fully closed casing made of aluminium.
Feed cable from the front and protected by a tube.
Fixing bracket for isolator switch or connection box to be fixed at the base frame.
Base frame for upstand fitting with wide overhung for integrating isolating material on roof.
Discharge to be protected against weather by integrated back draught dampers closing at standstill
of the fan.
Centrifugal impeller with backward curved blades made of steel, welded and coated.
All mechanically stressed parts made of galvanized sheet steel, motor separated from air stream
and cooled by outside air. Motor cabinet additionally thermally isolated.
The roof fans comply with the tolerances of Class 2 of DIN 24 166 Fans, Technical Specifications.
Fan type
................................................................
Flow rate
........................................................................... m3/h
Pressure increase
........................................................................... Pa
........................................................................... C
Speed
........................................................................... 1/min
Motor rating
........................................................................... kW
Voltage/frequency
........................................................................... V/Hz
........................................................................... dB
Weight
........................................................................... kg
Dimensions
........................................................................... mm
Wolf GmbH, Postfach 1380, D-84048 Mainburg, Tel.: 087 51 / 74-0, Fax: 087 51 / 74-1600, Internet: www.wolf-heiztechnik.de
44
Part no.: 48 00 135
07/06
GB
subject to modifications
Manual switch