Antisol S: Concrete Curing Compound

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Product Data Sheet

Edition No. 03. 2005


Identification No. CC02
Antisol S

Antisol S

Construction

Concrete Curing Compound


Description

A ready to use aqueous solution of metallic silicates, incorporating penetrating


aids, designed for application to fresh concrete to inhibit evaporation of moisture,
increase the density and harden vertical or horizontal concrete surfaces. The
mechanism involves a microcrystalline seal through the formation of a course of
crystals in the upper layer of the concrete surface. Antisol S is chloride free.

Uses

Curing Compound
Antisol S may be applied to the horizontal surface of fresh concrete immediately
after bleed water has disappeared, or to vertical surfaces after stripping the
boxing to provide a moisture evaporation and assisting in complete hydration of
the cement.
Surface Hardening
Antisol S may be applied to green concrete to increase the density of the cured
surface thus improving its subsequent durability, abrasion resistance and
lessening any potential surface dusting problems.

Characteristics /
Advantages

n Can be used as a concrete curing system where subsequent


surface treatments or paints are to be applied.
n Clear, non-staining and non toxic thus suitable for water
retaining structure.
n Non-flammable and can be employed in place of solvent based
products.
n A concrete curing system which promotes strength, surface
hardness and durability and significantly reduced any subsequent dusting
problems.

Application

Vertical Surfaces
After striking shutters, dampen down the concrete thoroughly with fresh water allow the surface water to drain off then apply Antisol S either with standard
spray equipment or a lambs wool roller (spray application are preferred for full
coverage). Observe that the surface is fully wetted. Where a highly durable
abrasion resistant surface is required, i.e. in severe exposure conditions, apply a
further coat of Antisol S after 3 days. Where subsequent surfacing systems are
to be applied, allow 7 days before overlaying Antisol S.
Horizontal Surfaces
Apply Antisol S with spray equipment or a lambs wool roller immediately after
final trowelling when all bleed water has disappeared. Ensure full surfaces
wetting and in any case apply not less than the coverage specified below.
Earliest practical application after the concrte surfaces are ready to receive the
curing compound is recommended so as to obtain optimum performances from
the system. As a vertical surfaces, apply a second coat to maximize the benefits.

Coverage

Apply Antisol S to both vertical and horizontal surfaces at a rate of one litre per
5.5 square meters for the first application and 1 litre per 7 square meters for the
second application.

Antisol S 1/2

Construction

Technical Data
Form

Sodium Silicate

Appearance / Colour

Transparent

Density

1.1 + 0.005

Storage Condition

Free from frost and naked flame

Shelf Life

1 year when unopened

Packaging

210 ltr. drums

Architects Specifications for


Surface Curing Membrane

Concrete surfaces shall be protected from the rapid evaporation of mix water to
ensure maximum hydration of the cement content and elimination of surface
crazing due to differential drying. All concrete surfaces shall be treated with
silicate based surface curing compound such as Antisol S. The curing compound
shall be applied strictly in accordance with the manufacturers specification and
instruction for handling. The first application shall be applied immediately after
the surface water has disappeared and final trowelling has been completed. A
second coat shall be applied after 7 days.

Legal Notice

The information, and, in particular, the recommendations relating to the application and end-use of Sika
products, are given in good faith based on Sikas current knowledge and experience of the products when
properly stored, handled and applied under normal conditions in accordance with Sikas recommendations.
In practice, the differences in materials, substrates and actual site conditions are such that no warranty
in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal
relationship whatsoever, can be inferred either from this information, or from any written recommendations,
or from any other advice offered. The user of the product must test the products suitability for the intended
application and purpose. Sika reserves the right to change the properties of its products. The proprietary
rights of third parties must be observed. All orders are accepted subject to our current terms of sale and
delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product
concerned, copies of which will be supplied on request.

Sika Philippines, Inc.


Unit A & B
888 Marcos Alvarez, Ave.
Talon, Las Pias City 1747
Philippines

Tel.no.
: 800 1818
Fax. no
: 806 2378
www.sika.com.ph
Antisol S 2/2