Professional Documents
Culture Documents
SMSC Usb
SMSC Usb
SMSC Usb
18
SMSC USB 2.0 Analog Routing
Guidelines
General Description
This application note discusses the fundamental Layout practices that should be used for the Analog portion
(RTERM, USB+/-, FS+/-, RBIAS, XTAL1, XTAL2) of the SMSC USB 2.0 products to alleviate problems with EMI, and
USB Signal integrity.
SMSC AN 9.18
Rev. 07/09/2002
PRELIMINARY
80 Arkay Drive
Hauppauge, NY 11788
(631) 435-6000
FAX (631) 273-3123
SMSC AN 9.18
Page 2
PRELIMINARY
Rev. 07/09/2002
The XTAL and USB I/O buffers on the USB 2.0 products are powered from the VDDA/ VSSA analog power rail. For
the reason discussed previously the crystal circuit (XTAL lines, Crystal, Filter capacitors), USB+/-, and FS+/- should
be referenced to this same analog ground.
Furthermore, it is suggested that the XTAL and USB signals are separated by at least 50 mils as quickly as possible
after breaking out of the chip, thus minimizing the area for cross talk to occur.
Here are some guidelines, which have been used on the SMSC evaluation platform:
Analog ground should be tied to Digital Ground through a "Moating" technique, or through a resistor, to isolate analog
and digital loop currents. Avoid any digital signals encroaching on or crossing the analog ground plane as well as any
analog signals crossing or encroaching on the Digital Ground plane.
(See Figure 1).
Signals that should be referenced to the Analog Ground plane are:
RBIAS
RTERM
XTAL1
XTAL2
USB +/FS +/USB+/- and FS+/- should be routed to have a differential impedance of 90 ohms. This can be accomplished with a
7.5 mil trace and a 7.5 mil space on a 4.5 mil FR4 dielectric.
7.5
mil
0.7 mil
7.5
mil
Trace
7.5
mil
Trace
Dielectric
4.5
mil
Gnd Plane
SMSC AN 9.18
Page 3
PRELIMINARY
Rev. 07/09/2002
Ground Moating
XTAL Lines
USB FS Termination
Resistors
USB Analog
ground plane
Digital
ground plane
USB Lines
SMSC AN 9.18
Page 4
PRELIMINARY
Rev. 07/09/2002
Connect directly to USB silicon USB +/- and route through termination resistors (value
recommended by SMSC specification) to FS +/-
USBVCC :
Connected to +5V plane. (Recommended to use a Ferrite Bead to connect to any local voltage)
USBGND :
Shield GND :
Connected as a chassis ground. If a metal enclosure is used connect to that, if only plastic is used
for any enclosure leave unconnected
Conclusion
Following the guidelines in this application note will ensure a reduction in EMI, and increased Signal integrity for the
analog portion of any SMSC USB 2.0 chip.
Note that this application note serves only as a general set of guidelines that should be followed when using an
SMSC USB 2.0 chip. Specific customer requirements may both create new guidelines, which must be followed,
and/or force specific rules dictated here to be broken.
SMSC AN 9.18
Page 5
PRELIMINARY
Rev. 07/09/2002