Professional Documents
Culture Documents
Install Manual
Install Manual
Installation Manual
Model
KX-TDA30/KX-TDA100/KX-TDA200
SD Logo is
a trademark.
System Components
System Components Table for KX-TDA100/KX-TDA200
Model
Shelves
KX-TDA100
Basic Shelf
KX-TDA200
Basic Shelf
Trunk Cards
Extension Cards
Installation Manual
Description
KX-TDA0196
KX-TDA0180
KX-TDA0181
KX-TDA0182
KX-TDA0183
KX-TDA0184
KX-TDA0187
KX-TDA0188
KX-TDA0189
KX-TDA0193
KX-TDA0284
KX-TDA0288
KX-TDA0290CE/CJ
KX-TDA0290
KX-TDA0480
KX-TDA0484
KX-TDA0143
KX-TDA0144
KX-TDA0170
KX-TDA0171
KX-TDA0172
KX-TDA0173
KX-TDA0174
KX-TDA0175
Description
KX-TDA0161
KX-TDA0162
KX-TDA0166
KX-TDA0190
KX-TDA0191
KX-TDA0410
KX-TDA0103
KX-TDA0104
KX-TDA0108
KX-TDA0141CE
KX-TDA0141
KX-TDA0142CE
KX-TDA0142
KX-A229
KX-A258
KX-T30865
Doorphone
Description
Main Unit
KX-TDA30
Main Unit
Trunk Cards
KX-TDA3180
KX-TDA3183
KX-TDA3193
KX-TDA3280
KX-TDA3480
KX-TDA3171
KX-TDA3172
KX-TDA3173
KX-TDA3174
Extension Cards
Installation Manual
Description
KX-TDA3105
KX-TDA3161
KX-TDA3162
KX-TDA3166
KX-TDA3168
KX-TDA3191
KX-TDA3196
KX-TDA0141CE
KX-TDA0141
Additional AC Adaptor
KX-A228
KX-T30865
Doorphone
Note
The Hybrid IP-PBX does not support the following telephones:
The KX-T7090 headset can be connected to the KX-T7000, KX-T7200, KX-T7300, KX-T7400, and KX-T7500 (except for KXT7560/KX-T7565) series telephones.
Installation Manual
There are some optional service cards and features that are not available for certain
countries/areas. Consult your certified Panasonic dealer for detailed instructions.
The power supply capacity of the Hybrid IP-PBX may differ from the values described
in this manual depending on the model number. Please consult your dealer for
detailed information.
The KX-TDA100CN and KX-TDA200CN have a power supply unit (PSU-S and PSUM, respectively) pre-installed.
Installation Manual
4. Do not use this product near water, for example, near a bathtub, wash bowl, kitchen sink,
or laundry tub, in a wet basement, or near a swimming pool.
5. Do not place this product on an unstable cart, stand, or table. The product may fall,
causing serious damage to the product.
6. Slots and openings in the cabinet and the back or bottom are provided for ventilation; to
protect it from overheating, these openings must not be blocked or covered. The openings
should never be blocked by placing the product on a bed, sofa, rug, or other similar
surface. This product should never be placed near or over a radiator or other heat source.
This product should not be placed in a built-in installation unless proper ventilation is
provided.
7. This product should be operated only from the type of power source indicated on the
product label. If you are not sure of the type of power supply to your home, consult your
dealer or local power company.
8. This product is equipped with a 3-wire earthing type plug, a plug having a third (earthing)
pin. This plug will only fit into an earthing type power outlet. This is a safety feature. If you
are unable to insert the plug into the outlet, contact your electrician to replace your
obsolete outlet. Do not defeat the safety purpose of the earthing type plug.
9. Do not allow anything to rest on the power cord. Do not locate this product where the cord
will be abused by people walking on it.
10. Do not overload wall outlets and extension cords as this can result in the risk of fire or
electric shock.
11. Never push objects of any kind into this product through cabinet slots as they may touch
dangerous voltage points or short out parts that could result in a risk of fire or electric
shock. Never spill liquid of any kind on the product.
12. To reduce the risk of electric shock, do not disassemble this product, but take it to a
qualified person when some service or repair work is required. Opening or removing
covers may expose you to dangerous voltages or other risks. Incorrect reassembly can
cause electric shock when the appliance is subsequently used.
13. Unplug this product from the wall outlet and refer servicing to qualified service personnel
under the following conditions:
a)
b)
c)
d)
e) If the product has been dropped or the cabinet has been damaged.
Installation Manual
f)
14. Avoid using a telephone (other than a cordless type) during an electrical storm. There may
be a remote risk of electric shock from lightning.
15. Do not use the telephone to report a gas leak in the vicinity of the leak.
Installation Manual
Precaution
Keep the unit away from heating appliances and electrical noise generating devices such
as fluorescent lamps, motors and televisions. These noise sources can interfere with the
performance of the Hybrid IP-PBX.
This unit should be kept free of dust, moisture, high temperature (more than 40 C) and
vibration, and should not be exposed to direct sunlight.
Never attempt to insert wires, pins, etc. into the vents or other holes of this unit.
If there is any trouble, disconnect the unit from the telephone line. Plug an SLT into the
telephone line. If the telephone operates properly, do not reconnect the unit to the line until
the trouble has been repaired by an authorised Panasonic Factory Service Centre. If the
telephone does not operate properly, chances are that the trouble is in the telephone
network, and not in the Hybrid IP-PBX.
Do not use benzene, thinner, or the like, or any abrasive powder to clean the cabinet. Wipe
it with a soft cloth.
When the unit is working, the noise is less than 70 dB (A) according to DIN 45635 Part 19.
For users in Finland, Norway and Sweden only (KX-TDA100/KX-TDA200 only)
This unit may only be installed in a room or space with restricted access, and equipotential
bonding must be applied. For information on earthing, refer to "2.2.5 Frame Earth
Connection".
For users in New Zealand only
This equipment shall not be set to make automatic calls to the Telecom '111' Emergency
Service.
The grant of a Telepermit for any item of terminal equipment indicates only that Telecom
has accepted that the item complies with minimum conditions for connection to its
network. It indicates no endorsement of the product by Telecom, nor does it provide any
sort of warranty. Above all, it provides no assurance that any item will work correctly in all
respects with another item of Telepermitted equipment of a different make or model, nor
does it imply that any product is compatible with all of Telecom's network services.
This equipment is not capable, under all operating conditions, of correct operation at the
higher speeds for which it is designed. Telecom will accept no responsibility should
difficulties arise in such circumstances.
Some parameters required for compliance with Telecom's Telepermit requirements are
dependent on the equipment (PBX) associated with this modem. In order to operate within
the limits for compliance with Telecom's Specifications, the associated PBX equipment
shall be sent to ensure that modem calls are answered between 3 and 30 seconds of
receipt of ringing.
IMPORTANT NOTICE
Under power failure conditions, the wireless telephones may not operate. Please ensure
that a separate telephone, not dependent on local power, is available for emergency use
in emergencies.
For users in Australia only
No External TRC Terminal is provided due to an Internal Link between PE and TRC.
Installation Manual
WARNING
CAUTION
DANGER OF EXPLOSION EXISTS IF THE BATTERY IS INCORRECTLY REPLACED.
REPLACE THE BATTERY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED
BY THE BATTERY MANUFACTURER. DISPOSE OF USED BATTERIES ACCORDING
TO THE MANUFACTURERS INSTRUCTIONS.
The serial number of this product may be found on the label affixed to the
side of the unit. You should note the model number and the serial number
of this unit in the space provided and retain this book as a permanent
record of your purchase to aid in identification in the event of theft.
MODEL No.:
SERIAL No.:
Installation Manual
The KX-TDA30E, the KX-TDA30NE, the KX-TDA30GR, and the KX-TDA30CE are
designed to interwork with the:
Analogue Public Switched Telephone Network (PSTN) of a European country
Pan-European Integrated Services Digital Network (ISDN) using ISDN basic rate access
The KX-TDA100E/KX-TDA200E, the KX-TDA100NE/KX-TDA200NE, the KXTDA100GR/KX-TDA200GR, and the KX-TDA100CE/KX-TDA200CE are designed to
interwork with the:
Analogue Public Switched Telephone Network (PSTN) of a European country
Pan-European Integrated Services Digital Network (ISDN) using ISDN basic rate access
Pan-European Integrated Services Digital Network (ISDN) using ISDN primary rate
access
ONP 2048 kbit/s digital structured leased lines (D2048S)
We, Panasonic Communications Co., Ltd./Panasonic Communications Company (U.K.) Ltd., declare
that this equipment is in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
If you would like to receive a copy of the original Declaration of Conformity of our products which
relates to the R&TTE, please visit our web address:
http://doc.panasonic-tc.de
10
Installation Manual
Introduction
This Installation Manual is designed to serve as an overall technical reference for the
Panasonic Hybrid IP-PBX, KX-TDA30/KX-TDA100/KX-TDA200. It provides instructions for
installing the hardware, and programming the Hybrid IP-PBX using the KX-TDA30
Maintenance Console (for KX-TDA30) or the KX-TDA Maintenance Console (for KX-TDA100/
KX-TDA200).
Installation Manual
11
Trademarks
12
Installation Manual
If the plug contains a removable fuse cover, you must ensure that it is refitted when the fuse is
replaced. If you lose the fuse cover, the plug must not be used until a replacement cover is
obtained. A replacement fuse cover can be purchased from your local Panasonic Dealer.
IF THE FITTED MOULDED PLUG IS UNSUITABLE FOR THE SOCKET OUTLET IN YOUR
PREMISES, THEN THE FUSE SHOULD BE REMOVED AND THE PLUG CUT OFF AND
DISPOSED OF SAFELY. THERE IS A DANGER OF SEVERE ELECTRICAL SHOCK IF THE
CUT OFF PLUG IS INSERTED INTO ANY 13 AMP SOCKET.
If a new plug is to be fitted, please observe the wiring code as shown below. If in any doubt,
please consult a qualified electrician.
WARNING
THIS APPLIANCE MUST BE EARTHED.
IMPORTANT: The wires in this mains leads are coloured in accordance with the following
code:
Green-and-yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead of this apparatus may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows.
The wire that is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug
that is marked with the letter E or by the safety earth symbol
or coloured GREEN or
GREEN-AND-YELLOW.
The wire that is coloured BLUE must be connected to the terminal that is marked with the letter
N or coloured BLACK.
The wire that is coloured BROWN must be connected to the terminal that is marked with the
letter L or coloured RED.
Installation Manual
13
How to replace the fuse: Open the fuse compartment with a screwdriver and replace the fuse
and fuse cover.
This equipment should be used on PSTN lines requiring 2-wire Loop calling unguarded
clearing with Loop Disconnect or DTMF address signalling.
The equipment must be connected to direct exchange lines and a payphone should not be
connected as an extension.
999 and 112 can be dialled on the apparatus after accessing the Exchange line for the purpose
of making outgoing calls to the BT emergency (999) and (112) service.
During dialling, this apparatus may tinkle the bells of other telephones using the same line. This
is not a fault and we advise you not to call the Fault Repair Service.
14
Installation Manual
Table of Contents
<KX-TDA100/KX-TDA200>
1
1.1
1.1.1
1.2
1.2.1
1.2.2
1.3
1.3.1
1.4
1.4.1
1.4.2
1.4.3
2.1
2.1.1
2.2
2.2.1
2.2.2
2.2.3
2.2.4
2.2.5
2.2.6
2.2.7
2.2.8
2.2.9
2.2.10
2.2.11
2.2.12
2.2.13
2.2.14
2.3
2.3.1
2.3.2
2.3.3
2.4
2.4.1
2.4.2
2.4.3
2.4.4
2.4.5
2.4.6
2.4.7
2.4.8
2.4.9
Installation Manual
15
2.4.10
2.4.11
2.4.12
2.5
2.5.1
2.5.2
2.5.3
2.5.4
2.5.5
2.5.6
2.6
2.6.1
2.6.2
2.6.3
2.6.4
2.6.5
2.6.6
2.7
2.7.1
2.7.2
2.7.3
2.7.4
2.8
2.8.1
2.8.2
2.8.3
2.8.4
2.8.5
2.8.6
2.8.7
2.8.8
2.9
2.9.1
2.9.2
2.9.3
2.9.4
2.9.5
2.9.6
2.9.7
2.9.8
2.10
2.10.1
2.11
2.11.1
2.12
2.12.1
2.13
2.13.1
16
PRI23 Card.............................................................................................................. 98
IP-GW4 Card......................................................................................................... 101
IP-GW4E Card ...................................................................................................... 104
Installation of the Extension Cards KX-TDA100/KX-TDA200...................... 106
CSIF4 and CSIF8 Card ......................................................................................... 106
DHLC8 Card.......................................................................................................... 108
DLC8 Card ............................................................................................................ 111
DLC16 Card .......................................................................................................... 113
SLC8 Card............................................................................................................. 115
SLC16 and MSLC16 Cards................................................................................... 117
Installation of the Other Cards KX-TDA100/KX-TDA200 ............................. 119
OPB3 Card ............................................................................................................ 119
DPH4 Card ............................................................................................................ 120
DPH2 Card ............................................................................................................ 122
ECHO16 Card ....................................................................................................... 125
MSG4 Card ........................................................................................................... 126
CTI-LINK Card....................................................................................................... 127
Connection of Extensions KX-TDA100/KX-TDA200 .................................... 129
Maximum Cabling Distances of the Extension Wiring (Twisted Cable) ................. 129
Parallel Connection of the Extensions................................................................... 130
Digital EXtra Device Port (Digital XDP) Connection .............................................. 132
First Party Call Control CTI Connection ................................................................ 137
Connection of DECT Portable Stations KX-TDA100/KX-TDA200 ............... 138
Overview ............................................................................................................... 138
Procedure Overview.............................................................................................. 140
Site Planning ......................................................................................................... 142
Before Site Survey ................................................................................................ 146
Site Survey Using the KX-TCA255/KX-TD7590.................................................... 150
After Site Survey ................................................................................................... 154
Connecting a Cell Station to the Hybrid IP-PBX ................................................... 155
Wall Mounting........................................................................................................ 164
Connection of 2.4 GHz Portable Stations KX-TDA100/KX-TDA200 ............ 166
Overview ............................................................................................................... 166
Procedure Overview.............................................................................................. 168
Site Planning ......................................................................................................... 170
Before Site Survey ................................................................................................ 174
Site Survey ............................................................................................................ 176
After Site Survey ................................................................................................... 180
Connecting a Cell Station to the Hybrid IP-PBX ................................................... 181
Wall Mounting........................................................................................................ 189
Connection of Doorphones and Door Openers KX-TDA100/KX-TDA200 .. 191
Connection of Doorphones and Door Openers..................................................... 191
Connection of Peripherals KX-TDA100/KX-TDA200 .................................... 194
Connection of Peripherals ..................................................................................... 194
Power Failure Connections KX-TDA100/KX-TDA200................................... 198
Power Failure Connections.................................................................................... 198
Starting the Hybrid IP-PBX KX-TDA100/KX-TDA200 ................................... 202
Starting the Hybrid IP-PBX.................................................................................... 202
Installation Manual
3.1
3.1.1
3.2
3.2.1
3.3
3.3.1
3.3.2
3.3.3
3.3.4
4.1
4.1.1
4.1.2
4.1.3
4.1.4
4.1.5
<KX-TDA30>
5
5.1
5.1.1
5.2
5.2.1
5.2.2
5.3
5.3.1
5.4
5.4.1
5.4.2
5.4.3
6.1
6.1.1
6.2
6.2.1
6.2.2
6.2.3
6.2.4
6.2.5
6.2.6
6.2.7
6.2.8
6.2.9
6.2.10
6.2.11
Installation Manual
17
6.3
6.3.1
6.3.2
6.3.3
6.3.4
6.3.5
6.4
6.4.1
6.4.2
6.4.3
6.4.4
6.5
6.5.1
6.5.2
6.5.3
6.5.4
6.5.5
6.5.6
6.5.7
6.6
6.6.1
6.6.2
6.6.3
6.6.4
6.7
6.7.1
6.7.2
6.7.3
6.7.4
6.7.5
6.7.6
6.7.7
6.7.8
6.8
6.8.1
6.8.2
6.8.3
6.8.4
6.8.5
6.8.6
6.8.7
6.8.8
6.9
6.9.1
6.10
6.10.1
6.11
6.11.1
6.12
6.12.1
18
Installation Manual
7.1
7.1.1
7.2
7.2.1
7.3
7.3.1
7.3.2
7.3.3
7.3.4
8.1
8.1.1
8.1.2
8.1.3
8.1.4
8.1.5
Appendix...................................................................................... 421
9.1
9.1.1
9.1.2
Revision History...................................................................................................422
KX-TDA100/KX-TDA200: Version 1.1 ....................................................................422
KX-TDA30: Version 1.1 ..........................................................................................423
Installation Manual
19
20
Installation Manual
Section 1
System Outline KX-TDA100/KX-TDA200
Installation Manual
21
1.1
1.1.1
System Highlights
Networking Features
This Hybrid IP-PBX supports the following networking features:
TIE Line Service
A TIE line is a privately leased communication line between 2 or more PBXs, which
provides cost effective communications between company members at different locations.
Virtual Private Network (VPN)
VPN is a service provided by the telephone company. It uses an existing line as if it were
a private line.
QSIG Network
QSIG is a protocol which is based on ISDN (Q.931) and offers enhanced PBX features in
a private network.
Voice over Internet Protocol (VoIP) Network
The PBX can connect to another PBX via a private IP network. In this case, voice signals
are converted into IP packets and sent through this network.
22
Installation Manual
Installation Manual
23
1.2
1.2.1
Basic Shelf
The basic shelf contains an MPR card. For system expansion, optional service cards and a
power supply unit can be installed in the basic shelf.
KX-TDA100
KX-TDA200
24
Installation Manual
1.2.2
Private
IP Network
Hybrid IP-PBX
Router
PC
Batteries
Server PC
SLT
SLT
PC
Fax Machine
DPT
PC
Wireless Phone
APT
DSS Console
DPT
DSS Console
PC
Printer
ISDN Telephone
Doorphone & Door Opener
PS
CS
USB
KX-T7636/
KX-T7633
Pager/ Amplifier
Speaker
PC
Voice Processing
System
KX-T7600 DPT
KX-T7600 DPT
Installation Manual
25
Hybrid IP-PBX
LCOT4
(KX-TDA0183)
LCOT16
(KX-TDA0181)
Analogue
Trunk
Analogue
Trunk
Telephone
Company
E & M Line
ISDN BRI Line
(Digital Trunk)
T1 Line
(Digital Trunk)
E1 Line
(Digital Trunk)
Station Message
Detail Recording (SMDR)
PT-interface CS
DHLC8
(KX-TDA0170)
DSS
Console
PS
APT
DPT
DSS Console
DID8
(KX-TDA0182)
E&M8
(KX-TDA0184)
BRI8
(KX-TDA0288)
PRI30
(KX-TDA0290
CE/CJ)
PRI23
(KX-TDA0290)
IP-GW4
(KX-TDA0480)
Batteries
PC
CID8
(KX-TDA0193)
E1
(KX-TDA0188)
Router
KX-T7636/KX-T7633
CID/PAY8
(KX-TDA0189)
T1
(KX-TDA0187)
Private
IP Network
DPT
DLC8
(KX-TDA0171)
LCOT8
(KX-TDA0180)
BRI4
(KX-TDA0284)
ISDN PRI Line
(Digital Trunk)
DLC16
(KX-TDA0172)
IP-GW4E
(KX-TDA0484)
PSU-S/M/L*1
(KX-TDA0108/
KX-TDA0104/
KX-TDA0103)
MSLC16
(KX-TDA0175)
Voice
Processing
System
SLC8
(KX-TDA0173)
CSIF4
(KX-TDA0143)
SLT
Wireless Phone
Fax Machine
CSIF8
(KX-TDA0144)
CTI-LINK
(KX-TDA0410)
OPB3
(KX-TDA0190)
CS
PS
LAN
DPH4
(KX-TDA0161)
DPH2
(KX-TDA0162)
PC
Server PC*2
ECHO16
(KX-TDA0166)
MSG4
(KX-TDA0191)
MPR
(Installed by default)
MEC
(KX-TDA0105)
SLC16
(KX-TDA0174)
Server PC*2
RMT
(KX-TDA0196)
Amplifier
Pager/Speaker
Radio
PC
*1
*2
26
Mountable Equipment
The KX-TDA100CN and KX-TDA200CN have a power supply unit (PSU-S and PSU-M, respectively)
pre-installed.
Only 1 Server PC can be connected to the Hybrid IP-PBX. Two or more Server PCs cannot be used
simultaneously.
Installation Manual
1.3
Options KX-TDA100/KX-TDA200
1.3.1
Options
Maximum Quantity
Model No.
Model Name
Description
KX-TDA100 KX-TDA200
KX-TDA0105
Memory Expansion
Card (MEC)
KX-TDA0143
4 Cell Station
Interface Card
(CSIF4)
KX-TDA0144
8 Cell Station
Interface Card
(CSIF8)
KX-TDA0161
4-Port Doorphone
Card (DPH4)
KX-TDA0162
2-Port Doorphone
Card (German Type)
(DPH2)
KX-TDA0166
16-Channel Echo
Canceller Card
(ECHO16)
KX-TDA0170
KX-TDA0171
8-Port Digital
Extension Card
(DLC8)
KX-TDA0172
16-Port Digital
Extension Card
(DLC16)
KX-TDA0173
KX-TDA0174
Installation Manual
27
Maximum Quantity
Model No.
Model Name
Description
KX-TDA100 KX-TDA200
KX-TDA0175
KX-TDA0180
8-Port Analogue
Trunk Card (LCOT8)
KX-TDA0181
16-Port Analogue
16-port analogue trunk card with 4
Trunk Card (LCOT16) power failure transfer (PFT) ports.
KX-TDA0182
KX-TDA0183
4-Port Analogue
Trunk Card (LCOT4)
KX-TDA0184
KX-TDA0187
KX-TDA0188
KX-TDA0189
16
KX-TDA0190
KX-TDA0191
4-Channel Message
Card (MSG4)
KX-TDA0193
16
KX-TDA0196
KX-TDA0284
28
Installation Manual
Maximum Quantity
Model No.
Model Name
Description
KX-TDA100 KX-TDA200
KX-TDA0288
KX-TDA0290
KX-TDA0410
KX-TDA0480
4-Channel VoIP
Gateway Card (IPGW4)
KX-TDA0484
4-Channel VoIP
Gateway Card (IPGW4E)
KX-TDA0103
KX-TDA0104
KX-TDA0108
Installation Manual
29
1.4
Specifications KX-TDA100/KX-TDA200
1.4.1
General Description
Control Bus
Communication Bus
Switching
Non-blocking
Power Input
PSU-S
PSU-M
PSU-L
External Battery
7 years
Dialling
Trunk
Extension
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
1600
Operating
Environment
maximum
Temperature
0 C to 40 C
Humidity
10 % to 90 % (non-condensing)
Paging
30
Installation Manual
Internal
External
RS-232C
USB
Dimension
SLT
DPT
APT
PT-interface CS
KX-TDA100
KX-TDA200
KX-TDA100
Under 12 kg
KX-TDA200
Under 16 kg
Installation Manual
31
1.4.2
Characteristics
SLT: 600
Doorphone: 20
CS: 130
15 000
including set
; PT-interface CS: 65
minimum
1600
Hookswitch Flash/Recall
Timing Range
24 ms to 2032 ms
Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 10 W per 4 lines (BRI4)
4.5 W per 1 line, 20 W per 8 lines (BRI8)
Power Supply Method: Phantom Power Supply
600
10 000
32
Installation Manual
maximum
1.4.3
System Capacity
KX-TDA100
KX-TDA200
Trunk Card*1
Extension Card
Total
10
*1
One T1, E1, PRI30, PRI23, or IP-GW4 card counts as 2 cards. However, one IPGW4E card counts as 1 card.
Notes
For each card, the maximum number that can be installed in the Hybrid IP-PBX is
listed in "1.3.1 Options".
Any card that exceeds the capacity of the Hybrid IP-PBX will be ignored.
When the Hybrid IP-PBX starts up with an invalid configuration, some cards will be
ignored.
KX-TDA100
KX-TDA200
Without MEC
Card
With MEC
Card
Without MEC
Card
With MEC
Card
88
152
176
304
SLT and PT
64
128
128
256
SLT
64
64
128
128
PT
64
128
128
256
Telephone*1
CS
16
32
PS
128
128
Doorphone
16
Door Opener
16
64
128
64
128
256
128
Installation Manual
33
*1
A single "T1-OPX (Off Premise Extension) port" or "BRI/PRI extension port" is counted as a wired telephone.
Extension Card*1
MEC Figure
KX-T7560/KX-T7565 DPT
APT
DHLC8
SLC8
SLC16
16
MSLC16
16
CS (1 unit)
PT-interface CS (1 unit)
ISDN Extension
VPS (1 port)
*1
Only the extension cards that can support SLTs count for the MEC figures.
MEC Figure
48 units
48
SLC16
1 card
16
MSLC16
1 card
16
VPS
8 ports
Total
88
The total MEC figure is 88. As this exceeds 64, you need to install an MEC card for this
configuration.
34
Installation Manual
Extension Card*1
Load Figure
KX-T7560/KX-T7565 DPT
APT
DHLC8
SLC8
SLC16
16
MSLC16
16
CS (1 unit)
PT-interface CS (1 unit)
ISDN Extension
VPS (1 port)
*1
Only the extension cards that can support SLTs count for the load figures.
PSU Capability
Each PSU supports a different amount of load figures.
PSU Type
PSU-S*1
64
PSU-M*2
128
PSU-L*3
512
*1
*2
*3
Installation Manual
35
Load Figure
48 units
48
Other DPT
2 units
SLC16
1 card
16
MSLC16
1 card
16
VPS
8 ports
Total
96
The total load figure is 96. As this is between 64 and 128, you should install the PSU-M. But if
you expect expansion in the future, it may be better to install the PSU-L. There is no harm in
installing a PSU that is larger than is required for the current configuration.
36
Installation Manual
Section 2
Installation KX-TDA100/KX-TDA200
Installation Manual
37
2.1
2.1.1
Before Installation
Please read the following notes concerning installation and connection before installing the
Hybrid IP-PBX. Be sure to comply with applicable local regulations (e.g., law, guidelines).
3. Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Installation Precautions
This set is made for wall mounting (KX-TDA100/KX-TDA200) or floor standing (KX-TDA200
only). Avoid installing in the following places. (Doing so may result in malfunction, noise, or
discolouration.)
2. Sulphuric gases produced in areas where there are thermal springs, etc. may damage the
equipment or contacts.
3.
4.
5.
6.
7. Closer than 1.8 m to radios and televisions (both the Hybrid IP-PBX and PTs).
8. Do not obstruct the area around the Hybrid IP-PBX (for reasons of maintenance and
inspectionbe especially careful to allow at least 20 cm above and 10 cm at the sides of
the Hybrid IP-PBX for cooling).
Wiring Precautions
Be sure to follow these instructions when wiring.
1. Do not wire the telephone cable in parallel with an AC power source, computer, telex, etc.
If the cables are run near those wires, shield the cables with metal tubing or use shielded
cables and ground the shields.
38
Installation Manual
2. If cables are run on the floor, use protectors to prevent the wires from being stepped on.
Avoid wiring under carpets.
3. Avoid using the same power supply outlet for computers, telexes, and other office
equipment. Otherwise, the Hybrid IP-PBX operation may be interrupted by the inducted
noise from such equipment.
4. Please use 1-pair telephone wire for extension connection of (telephone) equipment such
as standard telephones, data terminals, answering machines, computers, Voice
Processing Systems, etc., except PTs (e.g., KX-T7600 series).
5. The power switch and battery switch of the Hybrid IP-PBX must be off during wiring. After
the wiring is completed, turn the power switch on.
8. The Hybrid IP-PBX is equipped with a 3-wire earthing type plug. This is a safety feature.
If you are unable to insert the plug into the outlet, contact your electrician to replace your
obsolete outlet. Do not defeat the purpose of the earthing-type plug.
Installation Manual
39
2.2
2.2.1
Unpacking
Unpack the box and check the items below:
KX-TDA100
KX-TDA200
Main Unit
Metal Bracket
Screw A
Screw B (Black)
Anchor Plug
SD Memory Card
*1
40
Installation Manual
2.2.2
Inside View
KX-TDA100
KX-TDA200
RS-232C Port
RS-232C Port
USB Port
USB Port
ALARM Indicator
RUN Indicator
ALARM Indicator
RUN Indicator
PSU Slot
Null Slot*
PSU Slot
Free Slots 1 to 10
Free Slots 1 to 5
Note
* Null slot is not available for any optional service card.
Installation Manual
41
2.2.3
Screw Cover
3. Slide the front cover to the right until it stops, then lift the front cover.
42
Installation Manual
Notes
For safety reasons, close the front cover and tighten the screw when the Hybrid IPPBX is in operation.
Do not forget to tighten the screw before securing the screw cover.
Installation Manual
43
2.2.4
Function
PSU Type
Current
PSU-S
(for KX-TDA100)
1.4 A
0.8 A
PSU-M
(for KX-TDA100/200)
2.5 A
1.4 A
PSU-L
(for KX-TDA200)
5.1 A
2.55 A
Input
Frequency
50 Hz or 60 Hz
PSU-S
PSU-M/PSU-L
Battery Switch
Battery Switch
Battery Connector
Battery Connector
Earth Terminal
Power Switch
Earth Terminal
AC Inlet
Power Switch
AC Inlet
For details about frame earth connection, refer to "2.2.5 Frame Earth Connection".
For details about backup batteries connection, refer to "2.2.6 Backup Batteries
Connection".
Safety Instructions
Each PSU complies with Safety Class 1 of IEC60950, EN60950, UL60950,
CAN/CSA-C22.2 No.60950, and AS/NZS60950; therefore a protective earth connection exists
between the mains outlet ground and the PSU case. To ensure the PBX chassis is safely
grounded, it is essential that the PSU case be securely fastened to the PBX chassis with the 4
screws provided with each PSU.
When installing or replacing PSU, basic safety precautions should always be followed to
reduce the risk of fire, electric shock and injury to persons, including the following:
44
Installation Manual
4. To protect the back board from static electricity, do not touch parts on the back board
in the main unit and PSU. To discharge static electricity, touch ground or wear an
earthing strap.
The following procedures are for installing or replacing a PSU only. Do not replace or
remove the PSU for any other purpose.
CAUTION
For safety reasons, do not touch parts in the PSU.
Guide Rail
Installation Manual
45
2. Push the release lever in the direction of the arrow, so that the PSU engages securely with
the connector on the back board.
Back Board
Release Lever
3. Turn the 4 screws clockwise, in the order indicated by the numbers 1 to 4, to fix the PSU.
3 2
Screws
4 1
46
Installation Manual
Screws
3. Pull the release lever in the direction of the arrow to disconnect the PSU from the back
board.
Back Board
Release Lever
New PSU
Current PSU
Installation Manual
47
2.2.5
Screw
supplied)*.
Earthing
wire
To earth
* For earthing wire, green-and-yellow insulation is required, and the cross-sectional area of
the conductor must be more than 0.75 mm2 or 18 AWG.
48
Installation Manual
2.2.6
Battery Switch
Battery Connector
OFF
Red
Black
Turn on the battery switch on the PSU only after the installation of the Hybrid IP-PBX is
finished and AC power is available.
For each backup battery, battery capacity of 28 Ah or below is recommended (otherwise,
the battery charge may not be maintained).
Make sure that the type and capacity of the 3 backup batteries are identical.
The Back-up Battery Cable should not be exposed to direct sunlight. Keep the Back-up
Battery Cable and the backup batteries away from heating appliances and fire. Place the
backup batteries in ventilated place.
For details about the backup batteries, refer to the manual intended for the batteries.
CAUTION
Installation Manual
49
2.2.7
Slot Condition
Card Type
Slot Type
KX-TDA100: Free Slots 1 to 5
KX-TDA200: Free Slots 1 to 10
Option Slot
MPR Slot
MPR Card
No
No
Yes
Trunk Cards
Yes
No
No
Extension Cards
Yes
No
No
OPB3 Card
Yes
Yes
No
CTI-LINK Card
Yes
Yes
No
CAUTION
To protect the back board from static electricity, do not touch parts on the back board in
the main unit and on the optional service cards. To discharge static electricity, touch
ground or wear an earthing strap.
Note
The optional service cards can be installed or removed while the DC power is supplied.
However, when installing or removing the MPR card, the DC power supply must be turned
off.
Guide Rail
50
Installation Manual
2. Holding the card as shown below, push the release lever in the direction of the arrow so
that the card engages securely with the connector on the back board.
Back Board
Release Lever
Screws
Note
Make sure the screws are tightened to earth the card securely.
Installation Manual
51
CAUTION
Failure to install the Blank Slot Cover may cause electromagnetic interferences.
52
Installation Manual
Note
For safety reasons, do not stretch, bend, or pinch the AC power cord.
Installation Manual
53
Screws
2. Pull the release lever in the direction of the arrow to disconnect the card from the back
board. Pull the card from the cabinet to remove it.
Back Board
Release Lever
54
Installation Manual
2.2.8
Types of Connectors
Connector Type
Pin Number
RJ11
1
4
Used for
DHLC8 (KX-TDA0170)
SLC8 (KX-TDA0173)
SLC16 (KX-TDA0174)
MSLC16 (KX-TDA0175)
LCOT8 (KX-TDA0180)
LCOT16 (KX-TDA0181)
LCOT4 (KX-TDA0183)
CSIF4 (KX-TDA0143)
CSIF8 (KX-TDA0144)
T1 (KX-TDA0187)
E1 (KX-TDA0188)
BRI4 (KX-TDA0284)
BRI8 (KX-TDA0288)
PRI30 (KX-TDA0290CE/CJ)
PRI23 (KX-TDA0290)
CTI-LINK (KX-TDA0410)
IP-GW4 (KX-TDA0480)
IP-GW4E (KX-TDA0484)
E1 (KX-TDA0188)
PRI30 (KX-TDA0290CE/CJ)
DHLC8 (KX-TDA0170)
DLC8 (KX-TDA0171)
DLC16 (KX-TDA0172)
SLC8 (KX-TDA0173)
SLC16 (KX-TDA0174)
MSLC16 (KX-TDA0175)
LCOT8 (KX-TDA0180)
LCOT16 (KX-TDA0181)
DID8 (KX-TDA0182)
LCOT4 (KX-TDA0183)
E&M8 (KX-TDA0184)
RJ45
8
BNC
1
2
Amphenol
Type A Type B
(Shielded twisted
pair cable)
50
25
26
Installation Manual
55
Connector Type
10-pin
8-pin
Terminal Terminal
Block
Block
Pin Number
1
1
10
Used for
DPH4 (KX-TDA0161)
DPH2 (KX-TDA0162)
IP-GW4 (KX-TDA0480)
Basic Shelf
MPR
MPR
RS-232C
6
USB
3
Mini Plug
2
4
56
Installation Manual
2.2.9
connecting T1, E1, PRI, and BRI cards using an RJ45 connector (except in Canada,
where the ferrite core is not necessarily required), or
5 cm
Installation Manual
57
Note
For every 4 cables, use 1 ferrite core; a ferrite core holds a maximum of 4 cables.
3 cm
If you need to open the ferrite core, use a flathead screwdriver to unlatch the case of the ferrite
core.
58
Installation Manual
Velcro
Tape
Velcro
Tape
Spring
Latch
Remove the
screw on the
optional service
card.
Spring
Latch
Installation Manual
59
60
LCOT4
RA
TA
RB
TB
RC
TC
RD
TD
Installation Manual
LCOT8
RA
TA
RB
TB
RC
TC
RD
TD
RE
TE
RF
TF
RG
TG
RH
TH
LCOT16
RA
TA
RB
TB
RC
TC
RD
TD
RE
TE
RF
TF
RG
TG
RH
TH
RI
TI
RJ
TJ
RK
TK
RL
TL
RM
TM
RN
TN
RO
TO
RP
TP
DID8
RA
TA
RB
TB
RC
TC
RD
TD
RE
TE
RF
TF
RG
TG
RH
TH
E&M8
TA
RA
T1A
R1A
EA
MA
SGA
SGB
TB
RB
T1B
R1B
EB
MB
TC
RC
T1C
R1C
EC
MC
TD
RD
T1D
R1D
ED
MD
TE
RE
T1E
R1E
EE
ME
TF
RF
T1F
R1F
EF
MF
TG
RG
T1G
R1G
EG
MG
TH
RH
T1H
R1H
EH
MH
DHLC8
RA
TA
D2A
D1A
RB
TB
D2B
D1B
RC
TC
D2C
D1C
RD
TD
D2D
D1D
RE
TE
D2E
D1E
RF
TF
D2F
D1F
RG
TG
D2G
D1G
RH
TH
D2H
D1H
DLC8
D2A
D1A
D2B
D1B
D2C
D1C
D2D
D1D
D2E
D1E
DLC16
D2A
D1A
D2B
D1B
D2C
D1C
D2D
D1D
D2E
D1E
D2F
D1F
D2G
D1G
D2H
D1H
D2I
D1I
D2J
D1J
D2K
D1K
D2L
D1L
D2M
D1M
D2N
D1N
D2O
D1O
D2P
D1P
MSLC16
RA
TA
RB
TB
RC
TC
RD
TD
RE
TE
RF
TF
RG
TG
RH
TH
RI
TI
RJ
TJ
RK
TK
RL
TL
RM
TM
RN
TN
RO
TO
RP
TP
SLC16
RA
TA
RB
TB
RC
TC
RD
TD
RE
TE
RF
TF
RG
TG
RH
TH
RI
TI
RJ
TJ
RK
TK
RL
TL
RM
TM
RN
TN
RO
TO
RP
TP
SLC8
RA
TA
RB
TB
RC
TC
RD
TD
RE
TE
RF
TF
D2F
D1F
RG
TG
D2G
D1G
RH
TH
D2H
D1H
1. Install 4 anchor plugs in the wall, using the metal bracket as a template. Fix the metal
bracket with 4 screws (A).
Anchor Plug
Wall
Hammer
Anchor Plug
Metal Bracket
6.5 mm
30 mm
TOP
TOP
Screw (A)
Screw (A)
Metal Bracket
Installation Manual
61
2. Hook the cabinet onto the metal bracket, making sure that the unit slides down and onto
the hooked parts of the metal bracket. Use 2 screws (B) to fix both sides of the cabinet.
TOP
Screw (B)
Notes
62
Installation Manual
Do not block the openings of the cabinet. Allow space of at least 20 cm above and 10
cm at the sides of the cabinet.
Make sure that the wall behind the cabinet is flat and free of obstacles, so that the
openings on the back of the cabinet will not be blocked.
Make sure that the wall behind the cabinet is not made of wood.
Be careful not to drop the cabinet.
1. Install 3 anchor plugs in the wall, using the metal bracket as a template. Fix the metal
bracket with 3 screws (A).
Anchor Plug
Hammer
Anchor Plug
Wall
6.5 mm
Metal Bracket
30 mm
TOP
Screw (A)
TOP
Screw (A)
Metal Bracket
Installation Manual
63
2. Hook the cabinet onto the metal bracket, making sure that the unit slides down and onto
the hooked parts of the metal bracket. Use 2 screws (B) to fix both sides of the cabinet.
TOP
Screw (B)
Notes
64
Installation Manual
Do not block the openings of the cabinet. Allow space of at least 20 cm above and 10
cm at the sides of the cabinet.
Make sure that the wall behind the cabinet is flat and free of obstacles, so that the
openings on the back of the cabinet will not be blocked.
Make sure that the wall behind the cabinet is not made of wood.
Be careful not to drop the cabinet.
Screw (A)
Metal Bracket
TOP
Screw (A)
Hammer
Anchor
Plug
Metal
Bracket
Anchor Plug
30 mm
Floor
6.5 mm
2. Remove the front cover of the cabinet (refer to "2.2.3 Opening/Closing the Front Cover").
Installation Manual
65
3. Lift the cabinet, attach it to the metal bracket, slide it backwards until it locks, and retain it
with 2 screws (B).
1
TOP
FRONT
Screws (B)
Metal Bracket
Notes
66
Installation Manual
Do not block the openings of the cabinet. Allow space of at least 20 cm above and 10
cm at the sides of the cabinet.
Make sure that the surface behind the cabinet is flat and free of obstacles, so that the
openings on the back of the cabinet will not be blocked.
Make sure that the surface behind the cabinet is not made of wood.
Be careful not to drop the cabinet.
4. Fix the front cover on the cabinet (refer to "2.2.3 Opening/Closing the Front Cover").
Installation Manual
67
KX-A207
TELESPIKE BLOK MODEL TSB (TRIPPE MFG. CO.)
SPIKE BLOK MODEL SK6-0 (TRIPPE MFG. CO.)
Krone 237A strips fitted with 14A/1 surge arrestors
Super MAX (PANAMAX)
MP1 (ITW LINK)
Installation
Trunk
Trunk
Trunk
Lightning
Protectors
Terminal
Board
Extn.
Hybrid
IP-PBX
Extn. Extn.
SLT
Earth
68
Installation Manual
PT
CS
Frame
Earth
Extn.: Extension line
Outside Installation
(Main Building)
Lightning Protectors
Trunk
(Another Building)
Trunk
Extn.
Terminal
Board
Extn.
Lightning
Protector
CS
Extn.
Extn.
SLT
Hybrid
IP-PBX
SLT
PT
PT
CS
Earth
Extn.: Extension Line
If you install an extension outside of the building, the following precautions are recommended:
Earthing
Wire
Hybrid
IP-PBX
(Underground)
Earth Rod
Installation Manual
69
2.
3.
4.
5.
Check obstructions.....None
Composition of the earth rod.....Metal
Depth of the earth rod.....More than 50 cm
Cross sectional area of the earthing wire.....More than 1.3 mm2
Notes
70
Installation Manual
2.3
2.3.1
MPR Card
Function
Contains the main processor for all processes, basic shelf main protocol, time switch (TSW)
control, detection of system clock alarm, basic shelf power down alarm, and watchdog timer
overflow. An MEC card and an RMT card can be mounted on the MPR card (refer to "2.3.2
MEC Card" and "2.3.3 RMT Card").
1
2
SD
CARD
LEDs
SD Memory Card
Slot Cover
Reset Button
System Initialise
Switch
SD
Memory
Card 3
SD
CARD
USB
BGM/MOH
Pager
4
SD
CARD
Notes
CAUTION
Use only the SD Memory Card included with the Hybrid IP-PBX.
The SD Memory Card contains software for all the processes of the Hybrid IP-PBX
and all the customer data. The SD Memory Card must be inserted before start up.
Installation Manual
71
Do not remove the SD Memory Card during the operation of the Hybrid IP-PBX.
Removing the SD Memory Card during operation may cause damage to the SD
Memory Card, or result in loss of data.
A LITHIUM BATTERY IS USED IN THE MPR CARD. THERE IS A RISK OF
EXPLOSION IF BATTERY IS REPLACED WITH THE INCORRECT TYPE. DISPOSE
OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
LED Indications
Indication
72
Colour
Description
OFF: Normal
ON: Alarm
SD ACCESS
ON: Accessing
Installation Manual
Green
2.3.2
MEC Card
Function
Memory expansion card for Broadcasting features and to double the number of DPTs, using
Digital XDP connection. To be mounted on the MPR card.
inside
Screw
MEC Card
Installation Manual
73
2.3.3
RMT Card
Function
Analogue modem card for remote communication with the Hybrid IP-PBX. V90 support. To be
mounted on the MPR card.
inside
Screw
RMT Card
74
Installation Manual
2.4
2.4.1
Function
LCOT4:
LCOT8:
4-port analogue trunk card with 2 power failure transfer (PFT) ports.
8-port analogue trunk card with 2 power failure transfer (PFT) ports. One CID8 or
CID/PAY8 card can be mounted on the LCOT8 card (refer to "2.4.3 CID/PAY8
Card" and "2.4.4 CID8 Card").
LCOT16: 16-port analogue trunk card with 4 power failure transfer (PFT) ports. A maximum
of 2 CID8 and CID/PAY8 cards can be mounted on the LCOT16 card (refer to
"2.4.3 CID/PAY8 Card" and "2.4.4 CID8 Card").
LED
Amphenol
To trunk
Installation Manual
75
Pin Assignments
Amphenol Connector
50
26
25
RA
Ring port 1
26
TA
Tip port 1
RB
Ring port 2
27
TB
Tip port 2
RC
Ring port 3
28
TC
Tip port 3
RD
Ring port 4
29
TD
Tip port 4
RE
Ring port 5
30
TE
Tip port 5
RF
Ring port 6
31
TF
Tip port 6
RG
Ring port 7
32
TG
Tip port 7
RH
Ring port 8
33
TH
Tip port 8
RI
Ring port 9
34
TI
Tip port 9
10
RJ
Ring port 10
35
TJ
Tip port 10
11
RK
Ring port 11
36
TK
Tip port 11
12
RL
Ring port 12
37
TL
Tip port 12
13
RM
Ring port 13
38
TM
Tip port 13
14
RN
Ring port 14
39
TN
Tip port 14
15
RO
Ring port 15
40
TO
Tip port 15
16
RP
Ring port 16
41
TP
Tip port 16
42- Reserved
50
17- Reserved
25
Notes
Pin assignments for the pins 5 to 8 and 30 to 33 are for the LCOT8 and LCOT16 card
only.
Pin assignments for the pins 9 to 16 and 34 to 41 are for the LCOT16 card only.
LED Indications
76
Indication
Colour
Description
CARD
STATUS
Green/
Red
Installation Manual
2.4.2
DID8 Card
Function
8-port DID trunk card.
LED
Amphenol
To DID line
Installation Manual
77
Pin Assignments
Amphenol Connector
50
26
25
RA
Ring port 1
26
TA
Tip port 1
RB
Ring port 2
27
TB
Tip port 2
RC
Ring port 3
28
TC
Tip port 3
RD
Ring port 4
29
TD
Tip port 4
RE
Ring port 5
30
TE
Tip port 5
RF
Ring port 6
31
TF
Tip port 6
RG
Ring port 7
32
TG
Tip port 7
RH
Ring port 8
33
TH
Tip port 8
925
Reserved
34- Reserved
50
LED Indications
78
Indication
Colour
Description
CARD
STATUS
Green/
Red
Installation Manual
2.4.3
CID/PAY8 Card
Function
8-port Caller ID signal type FSK/FSK (with Call Waiting Caller ID [Visual Caller ID])/DTMF, and
8 ports of Pay Tone Service (12 kHz/16 kHz). To be mounted on the LCOT8/LCOT16 cards.
OFF
ON
ON
SW2
SW2
Ports 09-16
CID/PAY8 Card
Screw
Ports 01-08
SW1
SW1
ON
ON
OFF
OFF
Type
Port Setting
DIP
Installation Manual
79
2.4.4
CID8 Card
Function
8-port Caller ID signal type FSK/FSK (with Call Waiting Caller ID [Visual Caller ID])/DTMF. To
be mounted on the LCOT8/LCOT16 cards.
inside
ON
SW2
CID8 Card
Screw
SW1
ON
OFF
Type
Port Setting
DIP
80
Installation Manual
2.4.5
E&M8 Card
Function
8-port E & M (TIE) trunk card. Type 5 support.
LED
Amphenol
Connect this optional service card to the trunk through terminal board from the E & M
(TIE) line; do not connect to the trunk directly.
To connect the Amphenol connector, refer to "2.2.10 Fastening Amphenol Type
Connector".
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "2.13.1
Starting the Hybrid IP-PBX".
Installation Manual
81
Pin Assignments
Amphenol Connector
50
26
82
25
TA
Tip port 1
26
RA
Ring port 1
T1A
Tip 1 port 1
27
R1A
Ring 1 port 1
EA
E line port 1
28
MA
M line port 1
SGA
SG line port 1
29
SGB
SG line port 2
TB
Tip port 2
30
RB
Ring port 2
T1B
Tip 1 port 2
31
R1B
Ring 1 port 2
EB
E line port 2
32
MB
M line port 2
TC
Tip port 3
33
RC
Ring port 3
T1C
Tip 1 port 3
34
R1C
Ring 1 port 3
10
EC
E line port 3
35
MC
M line port 3
11
TD
Tip port 4
36
RD
Ring port 4
12
T1D
Tip 1 port 4
37
R1D
Ring 1 port 4
13
ED
E line port 4
38
MD
M line port 4
14
TE
Tip port 5
39
RE
Ring port 5
15
T1E
Tip 1 port 5
40
R1E
Ring 1 port 5
16
EE
E line port 5
41
ME
M line port 5
17
TF
Tip port 6
42
RF
Ring port 6
18
T1F
Tip 1 port 6
43
R1F
Ring 1 port 6
19
EF
E line port 6
44
MF
M line port 6
20
TG
Tip port 7
45
RG
Ring port 7
21
T1G
Tip 1 port 7
46
R1G
Ring 1 port 7
22
EG
E line port 7
47
MG
M line port 7
23
TH
Tip port 8
48
RH
Ring port 8
24
T1H
Tip 1 port 8
49
R1H
Ring 1 port 8
25
EH
E line port 8
50
MH
M line port 8
Installation Manual
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
Installation Manual
83
2.4.6
T1 Card
Function
1-port T1 trunk card. EIA/TIA standard compliant.
LEDs
RJ45
To NT1 / Extension
When connecting this optional service card to the trunk, connect through NT1; do not
connect to the trunk directly.
When connecting the RJ45 connector, attach the included ferrite core (except in
Canada, where the ferrite core is not necessarily required). Refer to "2.2.9 Attaching
a Ferrite Core".
This optional service card can be used for either trunk or extension connection, by
setting the A/B switch or using the connector with appropriate pin assignments.
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "2.13.1
Starting the Hybrid IP-PBX".
CAUTION
T1 ports are SELV ports and should only be connected to SELV services.
Switch Settings
84
Switch
Type
A/B
Slide
Installation Manual
Pin Assignments
RJ45 Connector for Trunk Use
Level [V]
Function
RX+
(+)
RX-
(-)
Reserved
TX-
(-)
TX+
(+)
Level [V]
Function
TX-
(-)
TX+
(+)
Reserved
RX+
(+)
RX-
(-)
6-8 Reserved
6-8 Reserved
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
SYNC-ERR
Red
OFF: Normal
RAI
Red
OFF: Normal
AIS
Red
OFF: Normal
ON: Alarm
Installation Manual
85
Indication
Colour
Description
SYNC
Green
ON: Synchronised
Diameter
0.5 mm:
86
Installation Manual
Maximum Distance
Under 200 m
2.4.7
E1 Card
Function
1-port E1 trunk card. ITU-T standard compliant.
A
LEDs
B
RJ45
J308
OR
3
1 2
To NT1/Extension
For Frame
Ground Open
To NT1/Extension
For RJ45
For Frame
Ground Short
3
J309
OR
2 1
75
J309
OR
2 1
120
BNC (TX)
BNC (RX)
120
For BNC
3
1 2
75
In some countries/areas, this optional service card must not be connected to the
Public Switched Telephone Network.
When connecting this optional service card to the trunk, connect through NT1; do not
connect to the trunk directly.
Use only 1 type of connector (RJ45 or BNC) for connection; RJ45 and BNC cannot
be used simultaneously.
When connecting the RJ45 connector, attach the included ferrite core. Refer to "2.2.9
Attaching a Ferrite Core".
This optional service card can be used for either trunk or extension connection, by
setting the A/B switch or using the connector with appropriate pin assignments.
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "2.13.1
Starting the Hybrid IP-PBX".
CAUTION
E1 ports are SELV ports and should only be connected to SELV services.
Installation Manual
87
Switch Settings
Switch
Type
Termination
Slide
Select 120
used.
A/B
Slide
Frame Ground
Short
Short pin
J308 is for BNC (TX) outer conductor, and J309 is for BNC
(RX) outer conductor.
(default) or 75
Pin Assignments
RJ45 Connector for Trunk Use
No. Signal Name
Level [V]
Function
RX+
(+)
RX-
(-)
Reserved
TX-
(-)
TX+
(+)
Level [V]
Function
TX-
(-)
TX+
(+)
Reserved
RX+
(+)
RX-
(-)
6-8 Reserved
Level [V]
Function
TX+
(+)
TX-
(-)
6-8 Reserved
88
Installation Manual
Level [V]
Function
RX-
(-)
RX+
(+)
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
SYNC-ERR
Red
OFF: Normal
RAI
Red
OFF: Normal
AIS
Red
OFF: Normal
ON: Alarm
SYNC
Green
ON: Synchronised
Diameter
0.5 mm:
Maximum Distance
Under 200 m
Installation Manual
89
2.4.8
Function
BRI4: 4-port ISDN Basic Rate Interface card with 1 power failure transfer port. EURO-ISDN/
ETSI compliant.
BRI8: 8-port ISDN Basic Rate Interface card with 1 power failure transfer port. EURO-ISDN/
ETSI compliant.
LEDs
RJ45
(LINE 1 to LINE 8)
To NT1/ Extension
Notice
If the connected ISDN terminal has no external power source, make sure that the power
is supplied from the BRI4/BRI8 card by programming the Hybrid IP-PBX accordingly.
However, if there is an external power source to the terminal, make sure that there is no
power supplied to the terminal from the BRI4/BRI8 card. Failure to do so may cause
damage to the power supply circuit of the BRI4/BRI8 card or the terminal.
90
Installation Manual
Switch Settings
Switch
Type
A/B
Slide
Pin Assignments
RJ45 Connector for Trunk Use
Level [V]
Function
1-2 Reserved
TX1
(+)
Transmit data 1
RX2
(+)
Receive data 2
RX1
(-)
Receive data 1
TX2
(-)
Transmit data 2
7-8 Reserved
Level [V]
Function
1-2 Reserved
RX2
(+)
Receive data 2
TX1
(+)
Transmit data 1
TX2
(-)
Transmit data 2
RX1
(-)
Receive data 1
7-8 Reserved
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
Installation Manual
91
Indication
Colour
Description
LINE 8
LINE 7
LINE 6
LINE 5
LINE 4
LINE 3
LINE 2
LINE 1
Green
L2
Master
Clock
LED Pattern
OFF
OFF
OFF
1s
ON
OFF
OFF
1s
ON
ON
OFF
1s
ON
OFF
ON
1s
ON
ON
ON
1s
L1: ON (Synchronous)
L2: ON (Link established)/OFF (Link not established)
Master Clock: ON (Master)/OFF (Slave)
92
Installation Manual
Point-to-Point
TE
CAT 5: Under 150 m
TE 1
CAT 5: Under 500 m
TE 1
Point-to-Multipoint
TE 8
CAT 5: Under 50 m
Expansion
Point-to-Multipoint
TE 8
Installation Manual
93
2.4.9
PRI30 Card
Function
1-port ISDN Primary Rate Interface card (30B channels). EURO-ISDN/ETSI compliant.
LEDs
RJ45
To NT1 / Extension
To NT1/Extension
For RJ45
120
120
BNC (TX)
BNC (RX)
OR
For BNC
75
75
In some countries/areas, this optional service card must not be connected to the
Public Switched Telephone Network.
When connecting this optional service card to the trunk, connect through an NT1; do
not connect to the U interface of the trunk directly.
Use only 1 type of connector (RJ45 or BNC) for connection; RJ45 and BNC cannot
be used simultaneously.
When connecting the RJ45 connector, attach the included ferrite core. Refer to "2.2.9
Attaching a Ferrite Core".
This optional service card can be used for either trunk or extension connection, by
setting the A/B switch or using the connector with appropriate pin assignments.
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "2.13.1
Starting the Hybrid IP-PBX".
CAUTION
PRI ports are SELV ports and should only be connected to SELV services.
94
Installation Manual
Switch Settings
Switch
Type
Termination
Slide
Select 120
used.
A/B
Slide
(default) or 75
Pin Assignments
RJ45 Connector for Trunk Use
No. Signal Name
Level [V]
Function
RX+
(+)
RX-
(-)
Reserved
TX-
(-)
TX+
(+)
Level [V]
Function
TX-
(-)
TX+
(+)
Reserved
RX+
(+)
RX-
(-)
6-8 Reserved
Level [V]
Function
TX+
(+)
TX-
(-)
6-8 Reserved
Installation Manual
95
Level [V]
Function
RX-
(-)
RX+
(+)
LED Indications
96
Indication
Colour
Description
CARD
STATUS
Green/
Red
SYNC-ERR
Red
OFF: Normal
RAI
Red
OFF: Normal
AIS
Red
OFF: Normal
ON: Alarm
SYNC
Green
ON: Synchronised
D-LINK
Green
ON: Established
Installation Manual
Diameter
0.5 mm:
Maximum Distance
Under 200 m
Installation Manual
97
LEDs
RJ45
To NT1/ Extension
When connecting this optional service card to the trunk, connect through an NT1; do
not connect to the U interface of the trunk directly.
When connecting the RJ45 connector, attach the included ferrite core (except in
Canada, where the ferrite core is not necessarily required). Refer to "2.2.9 Attaching
a Ferrite Core".
This optional service card can be used for either trunk or extension connection, by
setting the A/B switch or using the connector with appropriate pin assignments.
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "2.13.1
Starting the Hybrid IP-PBX".
CAUTION
PRI ports are SELV ports and should only be connected to SELV services.
Switch Settings
98
Switch
Type
A/B
Slide
Installation Manual
Pin Assignments
RJ45 Connector for Trunk Use
Level [V]
Function
RX+
(+)
RX-
(-)
Reserved
TX-
(-)
TX+
(+)
Level [V]
Function
TX-
(-)
TX+
(+)
Reserved
RX+
(+)
RX-
(-)
6-8 Reserved
6-8 Reserved
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
SYNC-ERR
Red
OFF: Normal
RAI
Red
OFF: Normal
AIS
Red
OFF: Normal
ON: Alarm
Installation Manual
99
Indication
Colour
Description
SYNC
Green
ON: Synchronised
D-LINK
Green
ON: Established
Diameter
0.5 mm:
100
Installation Manual
Maximum Distance
Under 200 m
LEDs
RJ45 (10BASE-T)
To private IP network
Maximum length of the cable to be connected to this optional service card is 100 m.
The IP-GW4 card occupies the space of 2 free slots when it is installed in the Hybrid
IP-PBX.
For programming instructions and other information about the IP-GW4 card, refer to
the documentation for the IP-GW4 card. To programme the IP-GW4 card, use the PC
programming software designed for the IP-GW4 card.
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "2.13.1
Starting the Hybrid IP-PBX".
Installation Manual
101
Pin Assignments
RJ45 Connector (10BASE-T)
Function
TPO+
Transmit data+
TPO-
Transmit data-
TPI+
Receive data+
4-5 Reserved
TPI-
Receive data-
7-8 Reserved
LED Indications
102
Indication
Colour
Description
CARD
STATUS
Green/
Red
ONLINE
Green
ALARM
Red
Alarm indication
OFF: Normal
ON: Alarm
IAM BUSY
Green
LINK
Green
DATA
Green
COL
Green
Installation Manual
Indication
Colour
Description
SIOSEL
Green
Installation Manual
103
LEDs
RJ45
(10BASE-T/100BASE-TX)
To private IP network
Maximum length of the cable to be connected to this optional service card is 100 m.
The IP-GW4E card occupies the space of only 1 free slot when it is installed in the
Hybrid IP-PBX.
For programming instructions and other information about the IP-GW4E card, refer to
the documentation for the IP-GW4E card. To programme the IP-GW4E card, use the
web programming designed for the IP-GW4E card.
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "2.13.1
Starting the Hybrid IP-PBX".
Pin Assignments
RJ45 Connector (10BASE-T/100BASE-TX)
104
Installation Manual
Function
TPO+
Transmit data+
TPO-
Transmit data-
TPI+
Receive data+
4-5 Reserved
TPI-
Receive data-
7-8 Reserved
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
ONLINE
Green
ALARM
Red
Alarm indication
OFF: Normal
ON: Alarm
VoIP BUSY
Green
LINK
Green
DATA
Green
Installation Manual
105
2.5
2.5.1
Function
CSIF4: 4-port CS interface card for 4 CSs.
CSIF8: 8-port CS interface card for 8 CSs.
LED
RJ45
(LINE 1 to LINE 8)
To CS
106
Installation Manual
Pin Assignments
RJ45 Connector
Function
1-2 Reserved
D1
POWH
Power (High)
POWL
Power (Low)
D2
7-8 Reserved
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
Installation Manual
107
2.5.2
DHLC8 Card
Function
8-port digital hybrid extension card for DPTs, APTs, SLTs, DSS consoles, and PT-interface
CSs, with 2 power failure transfer (PFT) ports.
LED
Amphenol
To extensions
108
Installation Manual
Attach the included ferrite core to the cable. Refer to "2.2.9 Attaching a Ferrite Core".
To connect the Amphenol connector, refer to "2.2.10 Fastening Amphenol Type
Connector".
For details about power failure transfer, refer to "2.12.1 Power Failure Connections".
Pin Assignments
Amphenol Connector
50
26
25
RA
26
TA
D2A
27
D1A
Reserved
28
Reserved
RB
29
TB
D2B
30
D1B
Reserved
31
Reserved
RC
32
TC
D2C
33
D1C
Reserved
34
Reserved
10
RD
35
TD
11
D2D
36
D1D
12
Reserved
37
Reserved
13
RE
38
TE
14
D2E
39
D1E
15
Reserved
40
Reserved
16
RF
41
TF
17
D2F
42
D1F
18
Reserved
43
Reserved
19
RG
44
TG
20
D2G
45
D1G
21
Reserved
46
Reserved
22
RH
47
TH
23
D2H
48
D1H
49- Reserved
50
24- Reserved
25
Installation Manual
109
LED Indications
110
Indication
Colour
Description
CARD
STATUS
Green/
Orange/
Red
Installation Manual
2.5.3
DLC8 Card
Function
8-port digital extension card for DPTs, DSS consoles, and PT-interface CSs.
LED
Amphenol
To extensions
Attach the included ferrite core to the cable. Refer to "2.2.9 Attaching a Ferrite Core".
To connect the Amphenol connector, refer to "2.2.10 Fastening Amphenol Type
Connector".
Installation Manual
111
Pin Assignments
Amphenol Connector
50
26
25
Reserved
26
Reserved
D2A
27
D1A
3-4 Reserved
28- Reserved
29
30
6-7 Reserved
31- Reserved
32
D2C
33
910
Reserved
34- Reserved
35
11
D2D
36
12- Reserved
13
37- Reserved
38
14
39
15- Reserved
16
40- Reserved
41
17
42
18- Reserved
19
43- Reserved
44
20
45
21- Reserved
22
46- Reserved
47
23
48
49- Reserved
50
D2B
D2E
D2F
D2G
D2H
24- Reserved
25
D1B
D1C
D1D
D1E
D1F
D1G
D1H
LED Indications
112
Indication
Colour
Description
CARD
STATUS
Green/
Orange/
Red
Installation Manual
2.5.4
DLC16 Card
Function
16-port digital extension card for DPTs, DSS consoles, and PT-interface CSs.
LED
Amphenol
To extensions
Attach the included ferrite core to the cable. Refer to "2.2.9 Attaching a Ferrite Core".
To connect the Amphenol connector, refer to "2.2.10 Fastening Amphenol Type
Connector".
Installation Manual
113
Pin Assignments
Amphenol Connector
50
26
25
D2A
26
D1A
D2B
27
D1B
D2C
28
D1C
D2D
29
D1D
D2E
30
D1E
D2F
31
D1F
D2G
32
D1G
D2H
33
D1H
D2I
34
D1I
10
D2J
35
D1J
11
D2K
36
D1K
12
D2L
37
D1L
13
D2M
38
D1M
14
D2N
39
D1N
15
D2O
40
D1O
16
D2P
41
D1P
42- Reserved
50
17- Reserved
25
LED Indications
114
Indication
Colour
Description
CARD
STATUS
Green/
Orange/
Red
Installation Manual
2.5.5
SLC8 Card
Function
8-port extension card for SLTs with 2 power failure transfer (PFT) ports.
LED
Amphenol
To extensions
Attach the included ferrite core to the cable. Refer to "2.2.9 Attaching a Ferrite Core".
To connect the Amphenol connector, refer to "2.2.10 Fastening Amphenol Type
Connector".
For details about power failure transfer, refer to "2.12.1 Power Failure Connections".
Installation Manual
115
Pin Assignments
Amphenol Connector
50
26
25
Ring port 1
26
2-3 Reserved
27- Reserved
28
Ring port 2
29
Tip port 2
5-6 Reserved
30- Reserved
31
Ring port 3
32
Tip port 3
8-9 Reserved
33- Reserved
34
10
Ring port 4
35
Tip port 4
11- Reserved
12
36- Reserved
37
13
Ring port 5
38
Tip port 5
14- Reserved
15
39- Reserved
40
16
Ring port 6
41
Tip port 6
17- Reserved
18
43- Reserved
44
19
Ring port 7
44
Tip port 7
20- Reserved
21
45- Reserved
46
22
Ring port 8
47
Tip port 8
48- Reserved
50
RA
RB
RC
RD
RE
RF
RG
RH
23- Reserved
25
TA
TB
TC
TD
TE
TF
TG
TH
Tip port 1
LED Indications
116
Indication
Colour
Description
CARD
STATUS
Green/
Red
Installation Manual
2.5.6
Function
SLC16:
16-port extension card for SLTs with 4 power failure transfer (PFT) ports.
MSLC16: 16-port extension card for SLTs with Message Waiting Lamp control and 4 power
failure transfer (PFT) ports. Maximum power output of 160 V/90 V for Message
Waiting Lamp control.
LED
Amphenol
To extensions
Panasonic SLT with Message Waiting Lamp (e.g., KX-T7310) is recommended for
connection to the MSLC16 card.
Attach the included ferrite core to the cable. Refer to "2.2.9 Attaching a Ferrite Core".
To connect the Amphenol connector, refer to "2.2.10 Fastening Amphenol Type
Connector".
For details about power failure transfer, refer to "2.12.1 Power Failure Connections".
Installation Manual
117
Pin Assignments
Amphenol Connector
50
26
25
RA
Ring port 1
26
TA
Tip port 1
RB
Ring port 2
27
TB
Tip port 2
RC
Ring port 3
28
TC
Tip port 3
RD
Ring port 4
29
TD
Tip port 4
RE
Ring port 5
30
TE
Tip port 5
RF
Ring port 6
31
TF
Tip port 6
RG
Ring port 7
32
TG
Tip port 7
RH
Ring port 8
33
TH
Tip port 8
RI
Ring port 9
34
TI
Tip port 9
10
RJ
Ring port 10
35
TJ
Tip port 10
11
RK
Ring port 11
36
TK
Tip port 11
12
RL
Ring port 12
37
TL
Tip port 12
13
RM
Ring port 13
38
TM
Tip port 13
14
RN
Ring port 14
39
TN
Tip port 14
15
RO
Ring port 15
40
TO
Tip port 15
16
RP
Ring port 16
41
TP
Tip port 16
42- Reserved
50
17- Reserved
25
LED Indications
118
Indication
Colour
Description
CARD
STATUS
Green/
Red
Installation Manual
2.6
2.6.1
OPB3 Card
Function
Optional 3-slot base card for mounting a maximum of 3 option cards from the following:
DPH4 card
DPH2 card
ECHO16 card
MSG4 card
LED
CAUTION
A LITHIUM BATTERY IS USED IN OPB3 CARD. THERE IS A RISK OF EXPLOSION IF
BATTERY IS REPLACED WITH THE INCORRECT TYPE. DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS.
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
Installation Manual
119
2.6.2
DPH4 Card
Function
4-port doorphone card for 4 doorphones and 4 door openers. To be mounted on the OPB3
card.
OPB3 Card
DPH4 Card
8-pin
Screw
To doorphones
To door openers
10-pin
120
Installation Manual
Pin Assignments
8-pin Terminal Block
Function
DP4
Doorphone 4 transmit
com4
Doorphone 4 receive
DP3
Doorphone 3 transmit
com3
Doorphone 3 receive
DP2
Doorphone 2 transmit
com2
Doorphone 2 receive
DP1
Doorphone 1 transmit
com1
Doorphone 1 receive
10
Function
1-2 Reserved
OP4b
Door opener 4
OP4a
OP3b
Door opener 3
OP3a
OP2b
Door opener 2
OP2a
OP1b
Door opener 1
10
OP1a
Installation Manual
121
2.6.3
DPH2 Card
Function
2-port doorphone card for 2 German type doorphones and 2 door openers. To be mounted on
the OPB3 card.
OPB3 Card
DPH2 Card
8-pin
Screw
To doorphones/
door openers
10-pin
122
Installation Manual
Pin Assignments
8-pin Terminal Block
Function
Path_2b
Doorphone 2 transmit
Path_2a
Doorphone 2 receive
Call_2b
Call_2a
Path_1b
Doorphone 1 transmit
Path_1a
Doorphone 1 receive
Call_1b
Call_1a
10
Function
1-2 Reserved
OP2b
Door opener 2
OP2a
OP1b
Door opener 1
OP1a
DC2b
Doorphone control 2
DC2a
DC1b
Doorphone control 1
10
DC1a
Installation Manual
123
8
7
6
5
4
3
2
1
RT
Door
Opener 2
BL
Call_2b
L O U B
Call_2a
~0 V L O U B~12 V~8 V TO
Path_2a
Path_2b
DC2b
DC2a
OP2b
Doorphone 2
Adaptor
220 V~
Door
Opener 1
BL
Call_1a
10
9
8
7
6
5
4
3
2
1
L O U B
Call_1b
~0 V L O U B~12 V~8 V TO
Path_1a
Path_1b
DC1b
DC1a
OP1b
OP1a
Doorphone 1
Adaptor
220 V~
124
Installation Manual
BL: Light
RT: Call Button
OP: Door Opener Connection Terminal
DC: Doorphone Current Supply Control Terminal
Path: Doorphone Call Path
: Speaker
: Microphone
: Shield
2.6.4
ECHO16 Card
Function
16-channel card for echo cancellation during conferences. To be mounted on the OPB3 card.
OPB3 Card
inside
ECHO16 Card
Screw
Installation Manual
125
2.6.5
MSG4 Card
Function
4-channel message card. To be mounted on the OPB3 card.
OPB3 Card
inside
MSG4 Card
Screw
126
Installation Manual
2.6.6
CTI-LINK Card
Function
Ethernet card for CTI communication via 10BASE-T port. CSTA Phase 3 protocol compatible.
LEDs
RJ45 (10BASE-T)
To LAN/
Server PC
Maximum length of the cable to be connected to this optional service card is 100 m.
This optional service card can be connected to PCs on a LAN via a Server PC to
provide third party call control CTI.
The operating system of the PC or Server PC required for third party call control
depends on your CTI application software. For details, refer to the manual for your CTI
application software.
Pin Assignments
RJ45 Connector (10BASE-T)
Function
TPO+
Transmit data+
TPO-
Transmit data-
TPI+
Receive data+
4-5 Reserved
TPI-
Receive data-
7-8 Reserved
Installation Manual
127
LED Indications
Indication
Colour
Description
CARD
STATUS
Green/
Red
128
Installation Manual
Flashing: In communication
2.7
2.7.1
Maximum Distance
Under 222 m
Under 347 m
Under 500 m
Under 347 m
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 500 m
Under 720 m
Under 830 m
Under 720 m
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 140 m
Under 229 m
Under 360 m
Under 229 m
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 698 m
Under 1128 m
Under 1798 m
Under 1128 m
PT-interface
CS
DPT
APT
PT-interface CS
KX-T7600 Series
Other PT and
DSS Console
SLT
DSS Console
SLT
DHLC8 Card
MSLC16, SLC16, SLC8
Cards
DLC16, DLC8 Cards
"
Installation Manual
129
2.7.2
With APT
To DHLC8 card
Modular
T-Adaptor
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "T", "R", "D1",
and "D2".
APT
SLT
With DPT
Parallel mode or eXtra Device Port (XDP) mode can be selected through system programming.
If the XDP mode is enabled through system programming, parallel connection is not possible.
Refer to "1.10.9 Parallelled Telephone" and "2.1.1 Extension Port Configuration" in the Feature
Guide for further information.
DPT
130
Installation Manual
SLT
To DHLC8 card
2-conductor wiring cord
Connect pins "T" and "R".
DPT
SLT
To DHLC8 card
To SLT
To DHLC8 card
2-conductor wiring cord
Connect pins "T" and "R".
DPT
SLT
TO TEL
To DHLC8 card
To SLT
Installation Manual
131
2.7.3
To DHLC8 card
(for connection of SLT)
SLT
Master DPT
Slave DPT
TO MAIN UNIT
/ PABX
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
TO MAIN UNIT
/ PABX
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
Under 50 m
Master DPT
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
132
Installation Manual
Slave DPT
Master DPT
Slave DPT
SLT
TO TEL
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
TO MAIN UNIT
/ PABX
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
Under 50 m
TO TEL
Master DPT
To DLC8/DLC16 card
Slave DPT
To SLT
To DHLC8 card
(for connection of SLT)
Installation Manual
133
To DHLC8 card
(for connection of SLT)
SLT
Master DPT
Slave DPT
TO MAIN UNIT
/ PABX
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
TO MAIN UNIT
/ PABX
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
Under 50 m
Master DPT
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
134
Installation Manual
Slave DPT
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Master DPT
Slave DPT
SLT
TO DIGITAL
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
TO MAIN UNIT
/ PABX
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
Under 50 m
TO TEL
Master DPT
To DLC8/DLC16 card
Slave DPT
To SLT
To DHLC8 card
(for connection of SLT)
Installation Manual
135
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
Master DPT
Slave DPT
SLT
Back View of DPTs
TO MAIN UNIT
/ PABX
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
To slave DPT
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
136
Installation Manual
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
To SLT
Under 50 m
TO DIGITAL
TO TEL
To PC
USB Cable
USB Port
L
UL
2.7.4
USB Module
Notes
Installation Manual
137
2.8
2.8.1
Overview
The following equipment is required to connect the wireless system:
CSIF4 (KX-TDA0143)
One CSIF4 card supports up to 4 Cell Stations. Up to 2 CSIF4 cards can be
connected to the KX-TDA100, and up to 4 can be connected to the KX-TDA200.
CSIF8 (KX-TDA0144)
One CSIF8 card supports up to 8 Cell Stations. Up to 2 CSIF8 cards can be
connected to the KX-TDA100, and up to 4 can be connected to the KX-TDA200.
KX-TDA0141CE Using a DHLC/DLC Card
This unit determines the area covered by the wireless system. Up to 2 calls can be made
at the same time through each CS.
Note for users in Europe
This Cell Station Unit for DECT is for connection to a Panasonic PBX of a European
country.
RF Specification
Item
Description
Frequency Band
Number of Carriers
10*2
Carrier Spacing
1728 kHz
Bit Rate
1152 kbps
Carrier Multiplex
Frame Length
10 ms
Modulation Scheme
GFSK
Roll-off factor=0.5
138
Differential Coding
Voice CODEC
Installation Manual
Item
Transmission Output
*1
*2
Description
Average 10 mW
Peak 250 mW
The number may vary depending on the country/area. In Taiwan, it is 1880 MHz to 1895 MHz.
The number may vary depending on the country/area. In Taiwan, it is 8.
CAUTION
The CS should be kept free of dust, moisture, high temperature (more than 40 C),
low temperature (less than 0 C), vibration, and should not be exposed to direct
sunlight.
The CS should not be placed outdoors (use indoors).
The CS should not be placed near high voltage equipment.
The CS should not be placed on a metal object.
Do not use this wireless system near another high power cordless system such as
DECT or SS wireless.
Keep the distances listed below between equipment in order to prevent noise,
interference or the disconnection of a conversation. (The distance may vary
depending on the environment.)
Equipment
Distance
More than 1 m
Each PS
More than 2 m
Too many CSs in a small area can cause problems due to conflicts over which signal
channels each CS can use. Ideally, CSs should be a minimum of 25 m to 40 m apart.
However, the required distance between CSs may vary depending on the
environment of the installation site and conditions in which the wireless system is
used. Conduct the site survey to determine the appropriate distance.
Installation Manual
139
2.8.2
Procedure Overview
When connecting the wireless system, use extreme care to conduct a site survey. Site surveys
can be conducted using the KX-TCA255 or KX-TD7590 PS. Inadvertent site survey can result
in poor service area, frequent noise, and disconnection of calls.
Channel No.
Display example:
RADIO STRENGTH
<<< MEASURING >>>
0 to 9
RADIO STRENGTH
CH0 SLOT:06 SYNC
L:12 0000/0100
CS-ID:9005301234
Channel No.
Display example:
RADIO STRENGTH
<<< MEASURING >>>
0 to 9
b. By walking away from the CS with the PS, check the radio signal strength. The radio
signal strength weakens as you walk away from the CS.
c. Map the CS coverage area at radio signal strength levels "3" and "8".
d. Make sure that adjacent CS coverage areas overlap where the radio signal strength
level is "8" by at least 5 m.
140
Installation Manual
e. Make sure that the radio signal strength level is greater than "3" at any location within
the service area demanded by the user.
a. Return all DIP switches of each CS to the OFF position, and stop supplying power.
b. Turn off the PS.
5. Connect the CS and PS to the Hybrid IP-PBX and test the operation
Refer to "2.8.7 Connecting a Cell Station to the Hybrid IP-PBX".
Installation Manual
141
2.8.3
Site Planning
Choosing the best site for the CS requires careful planning and testing of essential areas. The
best location may not always be convenient for installation. Read the following information
before installing the unit.
CS
1. Reflection
Column
2. Diffraction
3. Penetration
142
The CS coverage area is affected more by the building materials and their thickness than
the number of obstacles.
Radio waves tend to be reflected or diffracted by conductive objects and rarely penetrate
them.
Radio waves tend to penetrate insulated objects and are rarely reflected by them.
Radio waves penetrate thin objects more than thick objects.
The table below shows the transmission tendency of radio waves when they reach objects
made from various materials.
Installation Manual
Object
Material
Transmission Tendency
Wall
Concrete
Ferroconcrete
Glass
Window
Glass with wire nets Radio waves can penetrate them, but tend to be
reflected.
Glass covered with
heat-resistant film
Floor
Ferroconcrete
Partition
Steel
Plywood, Glass
Ferroconcrete
Metal
Steel
Wood
Column
Cabinet
Installation Manual
143
CS Coverage Area
The example below shows the size of the coverage area of 1 CS if it is installed where there is
no obstacle.
Note
Radio signal strength levels are measured during the site survey (refer to "2.8.5 Site
Survey Using the KX-TCA255/KX-TD7590").
Coverage Area
Radio signal strength level is
greater than "3".
(About 50 m to 60 m)
B
B
Gray Zone:
Conversation will be
intermittent
Out of Service:
Cannot make/receive calls
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
a. Draw the coverage area around a CS. Extend the coverage area to 30 m to 60 m in
one direction, depending on the materials of the building structures and obstacles in
the installation site. Note that a CS cannot be installed outside a building.
144
Installation Manual
b. If 1 CS cannot cover the entire service area, install additional CSs as required.
Overlap the coverage areas of adjacent CSs.
Where CS coverage areas overlap, the PS will start call handover to the next CS if the
signal from one CS becomes weak. However, if a PS moves away from a CS and
there are no CSs available for handover, the PS may go out of range and the call could
be lost.
The coverage area of each CS will not extend as much it does where there is no
obstacle, because the radio signals will be weakened by separating walls. Therefore,
you will need 5 CSs to cover the entire room.
150 m
70 m
CS no. 1
CS no. 2
CS no. 5
CS no. 3
CS no. 4
Installation Manual
145
2.8.4
ABC
A:
C:
ABC
E:
GHI
B:
D:
DEF
F:
JKL
CS No.
CS ID No.
0 to 7
0 to 9 and A to F
Note
To clear the CS ID number assigned to the PS, follow the procedure below:
To clear one by one
CS No.
0 to 7
1
DEF
3
To the Desired CS No.
OR
146
Installation Manual
ABC
A:
F1
C:
F3
E:
B:
F2
D:
INT'
F:
CS No.
CS ID No.
0 to 7
0 to 9 and A to F
OK
Note
To clear the CS ID number assigned to the PS, follow the procedure below:
To clear one by one
CS No.
0 to 7
1
DEF
3
To the Desired CS No.
OR
Installation Manual
147
DIP Switch
OFF
ON
1
2
Channel Number Switch
3
4
5
6
Radio Signal
Test Switch
Channel 0
Notes
148
Installation Manual
To see the radio signal strength of more than 1 CS, a channel number must be set for
each CS.
If more than 1 CS is in Radio Signal Test mode, each CS must have a unique channel
number.
3. After setting the DIP switch, connect an AC adaptor or battery box to the CS using a power
supply adaptor.
Note for users in the United Kingdom
240 V AC must not be used on a building site. Instead of an AC adaptor, connect a
battery box to the CS.
Telephone Cord
Modular
4. Install the CS temporarily for the site survey. Install the CS at least 2 m above the floor,
keeping the antennas in the upright position.
Installation Manual
149
2.8.5
Channel No.
Previous or Next
0 to 9
Display example:
RADIO STRENGTH
CH0*1 SLOT:06*2 SYNC*3
L:12*4 0000/0100*5
CS-ID:9005301234
Log No.
0 to 9
Channel No.
Previous or Next
0 to 9
Display example:
RADIO STRENGTH
<<< MEASURING >>>
Log No.
0 to 9
Notes
*1: Channel number
*2: Slot number
*3: When a slot is synchronised, "SYNC" is displayed.
*4: Radio signal strength level
*5: Frame error (0000 to 9999)/Frame counter (0000 to 9999). Frame error indicates the
number of errors out of 10 000 radio signal receptions. An increased number of frame
errors indicates greater radio signal interference and more frequent noise during
conversation. The ideal number of frame error is "0000".
150
Installation Manual
CAUTION
Storing the scan data will clear all directory data.
2. Measure the radio signal strength by moving to and away from the CS.
a. Move to the CS until the point the radio signal strength level becomes "12".
b. Move away from the CS and identify the CS coverage area within which the radio
signal strength level is greater than "8". Draw the area on the map.
c. Move away from the CS and identify the CS coverage area within which the radio
signal strength level is greater than "3". Draw the area on the map.
PS
Channel no. 0
CH0
L:12
PS
CH0
L:08
PS
CH0
L:03
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
Installation Manual
151
3. Repeat the steps 1 and 2 for other CSs, and relocate the CSs when necessary.
a. Overlap adjacent CS coverage areas where the radio signal strength level is "8" by 5
m to 10 m.
Channel no. 0
5 m to 10 m
Channel no. 1
b. Overlap the CS coverage areas of at least 2 CSs at any location in the installation site.
Channel no. 0
Channel no. 1
Channel no. 2
Channel no. 3
c. Make sure that the radio signal strength level is greater than "3" at any location in the
service area demanded by the user.
Notes
152
Installation Manual
If a channel is set, the results of measurement for the 24 slots on the channel are
saved each time. If the same channel is set, the new results override the previous
ones. Therefore, a measurement of 10 channels 24 slots in total can be made.
If correct results cannot be obtained (e.g., there are many error counters), change the
location of the CS and repeat the site survey to select the best location.
Log No.
0 to 9
To go to other slots
To go to specific channel
Channel No.
Previous or Next
0 to 9
A a
Log No.
0 to 9
To go to other slots
To go to specific channel
Channel No.
Previous or Next
0 to 9
GHI
GHI
Installation Manual
153
2.8.6
OFF
1
2
3
4
5
6
154
Installation Manual
ON
2.8.7
CSIF8 Card
Port 1
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 444 m
Under 694 m
Under 1000 m
Under 694 m
Pin No.
1
2
3
4
Pin No.
1
2
3
4
5
6
7
8
Signal Name
D1
POWH
POWL
D2
Installation Manual
155
DHLC8 Card
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 222 m
Under 347 m
Under 500 m
Under 347 m
CS (RJ11)
Signal Name
D1
D2
Pin No.
1
2
3
4
DHLC/DLC card
(Amphenol)
Signal Name
D1
D2
156
Installation Manual
Connecting the CS
1. Connect the cable from the CSIF/DHLC/DLC card to the CS.
Modular
To CSIF/DHLC/DLC card
2. Pass the cable through the groove of the CS (in any direction depending on your
preference).
TO MAIN UNIT
/ PABX
To CSIF/DHLC/DLC card
Installation Manual
157
3. Wrap the cable once around the ferrite core. Then close the case of the ferrite core.
To CSIF card
Note
If you need to open the ferrite core, use a flathead screwdriver to unlatch the case of the
ferrite core.
158
Installation Manual
Registering the PS
The PS must be registered to the Hybrid IP-PBX before it can be used. Programming of both
the PS and Hybrid IP-PBX is required. A PT with multiline display (e.g., KX-T7636 6-line
display) is required for the Hybrid IP-PBX system programming.
Note
For details about system programming using a PT, refer to "2.3.2 PT Programming" and
"3.3 PT Programming" in the Feature Guide.
#
PROGRAM/
PAUSE
Programming No.
= 1234
3 digits
Note
means default value.
PS Registration
One PS can be registered to a maximum of 4 different Hybrid IP-PBXs.
[690]
ENTER
PS No.
Extn. No.
001 to 128
1 to 4 digits
ENTER
To the PS
operation
below
END
Press POWER
for 2 seconds.
Select
"Setting Handset".
Select
"Registration".
"Please wait".
Select
"Register H/set".
Select
"Base 14".
C.Tone
Installation Manual
159
Press POWER
for 5 seconds.
To register for the first time
SELECT
/
Select
"INITIAL SETTING".
OR
To re-register
If required
SELECT
/
Select
"PS-PROGRAM".
Select
"REGISTRATION".
/OK
SELECT
4 digits
SELECT
/
Select
"DECT-SYS1-4"
PIN for
PS Registration
/OK
C.Tone
4 digits
/
Choose
"ENABLE/DISABLE".
4 digits
DISABLE
/OK
ENABLE
/OK
4 digits
/
Press POWER
for 2 seconds.
/
Select
"Register H/set".
160
Installation Manual
Select
"Setting Handset".
/
Select
"Base 14".
/
Select
"Registration".
PIN for
PS Registration
4 digits
C.Tone
By default, the PIN for PS registration is "1234" for both the Hybrid IP-PBX and PS.
Therefore, the PS can be registered to the Hybrid IP-PBX without setting the PIN.
The PIN for PS registration will only be used when registering the PS to the Hybrid
IP-PBX. Therefore, even when there is more than 1 Hybrid IP-PBX with the same PIN
near the PS, the PS will not be linked to a different Hybrid IP-PBX during normal
operation after registration.
Setting the PIN for Hybrid IP-PBX
[692]
ENTER
END
ENTER
Press POWER
for 2 seconds.
Select
"Setting Handset".
Select
"Select Language".
Select
"Display Option".
Press POWER
for 5 seconds.
SELECT
Select
"DISPLAY SETTING".
SELECT
SELECT
/
Select
"LANGUAGE".
SELECT
/
Select the desired
language.
/
Press POWER
for 2 seconds.
Select
"Setting Handset".
Select "Select
Language".
Select
"Display Option".
Installation Manual
161
PS Termination
Confirm the following before cancelling the PS registration:
PS is turned on.
[691]
PS No.
001 to 128
ENTER
ENTER
YES
Press "CLEAR".
To the PS
operation
below
END
Press "YES".
Press POWER
for 2 seconds.
Select
"Setting Handset".
Select
"Registration".
Select
"Cancel Base".
Handset PIN
C.Tone
4 digits
Select
"Base 14".
Select
"YES".
SELECT
Press POWER
for 5 seconds.
If required
/
Select the
desired item.
Select "CANCEL
DECT-SYS".
4 digits
SELECT
SELECT
/OK
SELECT
C.Tone
Select "YES".
/
Press POWER
for 2 seconds.
Handset PIN
Select
"Cancel Base".
4 digits
Select the
desired item.
Installation Manual
Select
"Registration".
Select "YES".
162
Select
"Setting Handset".
C.Tone
Installation Manual
163
2.8.8
Wall Mounting
1. Place the reference for wall mounting (on the following page) on the wall to mark the 2
screw positions.
Make sure that the screw heads are at the same distance from the wall.
Install the screws perpendicular to the wall.
164
Installation Manual
71 mm
Note
When you print out this page, the distance on the paper output may deviate slightly from
the measurement indicated above.
Installation Manual
165
2.9
2.9.1
Overview
The following equipment is required to connect the wireless system:
CSIF4 (KX-TDA0143)
One CSIF4 card supports up to 4 Cell Stations. Up to 2 CSIF4 cards can be
connected to the KX-TDA100, and up to 4 can be connected to the KX-TDA200.
CSIF8 (KX-TDA0144)
One CSIF8 card supports up to 8 Cell Stations. Up to 2 CSIF8 cards can be
connected to the KX-TDA100, and up to 4 can be connected to the KX-TDA200.
KX-TDA0141 Using a DHLC/DLC Card
This unit determines the area covered by the wireless system. Up to 2 calls can be made
at the same time through each CS.
CAUTION
The CS should be kept free of dust, moisture, high temperature (more than 40 C),
low temperature (less than 0 C), vibration, and should not be exposed to direct
sunlight.
The CS should not be placed outdoors (use indoors).
The CS should not be placed near high voltage equipment.
The CS should not be placed on a metal object.
Systems using 2.4 GHz ISM (Industrial, Scientific and Medical) band may interfere
with the KX-TDA wireless system. Examples of such systems are cordless
telephones, wireless LAN, Home RF, microwave ovens and other ISM devices. These
systems may cause minor noise.
Keeping some distance between the equipment listed below may prevent
interference. (The distance may vary depending on the environment.)
Equipment
Distance
166
Installation Manual
CS and PS
More than 1 m
Each PS
More than 2 m
Equipment
Distance
CS and CS
More than 15 m
Please take into consideration the distance between the CSs when site planning.
Please consult a certified dealer for details.
However, the required distance between CSs may vary depending on the
environment of the installation site and conditions in which the wireless system is
used. Conduct the site survey to determine the appropriate distance.
Installation Manual
167
2.9.2
Procedure Overview
When connecting the wireless system, use extreme care to conduct a site survey. Inadvertent
site survey can result in poor service area, frequent noise, and disconnection of calls.
a. Assign a CS number to each CS by setting the DIP switches on the back of the CS.
b. Supply electricity to each CS using an AC adaptor or a battery box.
c. Install each CS temporarily as planned.
Notes
CS No.
CS NO.1 LEVEL:12
<< SEARCHING >>
SAVE:0123456789
1 to 9
CS No.
CS NO.1 LEVEL:12
<< SEARCHING >>
1 to 9
SAVE:0123456789
b. By walking away from the CS with the PS, check the radio signal strength. The radio
signal strength weakens as you walk away from the CS.
c. Map the CS coverage area at radio signal strength levels "3" and "8".
d. Make sure that adjacent CS coverage areas overlap where the radio signal strength
level is "8" by at least 5 m.
e. Make sure that the radio signal strength level is greater than "3" at any location within
the service area demanded by the user.
168
Installation Manual
a. Return all DIP switches of each CS to the OFF position, and stop supplying power.
b. Turn off the PS.
5. Connect the CS and PS to the Hybrid IP-PBX and test the operation
Refer to "2.9.7 Connecting a Cell Station to the Hybrid IP-PBX".
Installation Manual
169
2.9.3
Site Planning
Choosing the best site for the CS requires careful planning and testing of essential areas. The
best location may not always be convenient for installation. Read the following information
before installing the unit.
CS
1. Reflection
Column
2. Diffraction
3. Penetration
170
The CS coverage area is affected more by the building materials and their thickness than
the number of obstacles.
Radio waves tend to be reflected or diffracted by conductive objects and rarely penetrate
them.
Radio waves tend to penetrate insulated objects and are rarely reflected by them.
Radio waves penetrate thin objects more than thick objects.
The table below shows the transmission tendency of radio waves when they reach objects
made from various materials.
Installation Manual
Object
Material
Transmission Tendency
Wall
Concrete
Ferroconcrete
Glass
Window
Glass with wire nets Radio waves can penetrate them, but tend to be
reflected.
Glass covered with
heat-resistant film
Floor
Ferroconcrete
Partition
Steel
Plywood, Glass
Ferroconcrete
Metal
Steel
Wood
Column
Cabinet
Installation Manual
171
CS Coverage Area
The example below shows the size of the coverage area of 1 CS if it is installed where there is
no obstacle.
Note
Radio signal strength levels are measured during the site survey (refer to "2.9.5 Site
Survey").
Coverage Area
Radio signal strength level is
greater than "3".
(About 50 m to 60 m)
B
B
Gray Zone:
Conversation will be
intermittent
Out of Service:
Cannot make/receive calls
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
a. Draw the coverage area around a CS. Extend the coverage area to 30 m to 60 m in
one direction, depending on the materials of the building structures and obstacles in
the installation site. Note that a CS cannot be installed outside a building.
172
Installation Manual
b. If one CS cannot cover the entire service area, install additional CSs as required.
Overlap the coverage areas of adjacent CSs.
Where CS coverage areas overlap, the PS will start call handover to the next CS if the
signal from one CS becomes weak. However, if a PS moves away from a CS and
there are no CSs available for handover, the PS may go out of range and the call could
be lost.
If the signal from the CS fades, due to the structure of the building, there may be some
handover delay. The user will hear a range warning before handover in this case. This
also applies in the case of interference from 2.4 GHz apparatus.
The coverage area of each CS will not extend as much it does where there is no
obstacle, because the radio signals will be weakened by separating walls. Therefore,
you will need 5 CSs to cover the entire room.
150 m
70 m
CS no. 1
CS no. 2
CS no. 5
CS no. 3
CS no. 4
Installation Manual
173
2.9.4
DIP Switch
OFF
ON
1
2
CS Number Switch
3
4
5
6
CS no. 1
CS no. 3
CS no. 4
CS no. 5
CS no. 6
CS no. 7
CS no. 8
CS no. 9
Notes
174
CS no. 2
Radio Signal
Test Switch
Installation Manual
To see the radio signal strength of more than 1 CS, a CS number must be set for each
CS.
If more than 1 CS is in Radio Signal Test mode, each CS must have a unique CS
number.
3. After setting the DIP switch, connect an AC adaptor or battery box to the CS using a power
supply adaptor.
Telephone Cord
Modular
4. Install the CS temporarily for the site survey. Install the CS at least 2 m above the floor,
keeping the antennas in the upright position.
Installation Manual
175
2.9.5
Site Survey
The PS has a Radio Signal Test mode that monitors the state of the radio link to the CS. After
installing the CSs temporarily, set the PS to the Radio Signal Test mode and measure each CS
coverage area. Then, record the results on the map of the installation site.
CS No.
CS NO.1 LEVEL:12*1
<< SEARCHING >>
1 to 9
SAVE:0123456789*2
CS No.
1 to 9
CS NO.1 LEVEL:12*1
<< SEARCHING >>
SAVE:0123456789*2
Notes
*1: CS number and radio signal strength level.
*2: Scan data (test result) number. Empty memory space will be indicated by a number;
stored memory space will be indicated by a "-".
176
Installation Manual
2. Measure the radio signal strength by moving to and away from the CS.
a. Move to the CS until the point the radio signal strength level becomes "12".
b. Move away from the CS and identify the CS coverage area within which the radio
signal strength level is greater than "8". Draw the area on the map.
c. Move away from the CS and identify the CS coverage area within which the radio
signal strength level is greater than "3". Draw the area on the map.
PS
CS NO.1 LEVEL:12
CS no. 1
PS
CS NO.1 LEVEL:8
PS
CS NO.1 LEVEL:3
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
3. Repeat the steps 1 and 2 for other CSs, and relocate the CSs when necessary.
a. Overlap adjacent CS coverage areas where the radio signal strength level is "8" by 5
m to 10 m.
CS no. 1
5 m to 10 m
CS no. 2
Installation Manual
177
b. Overlap the CS coverage areas of at least 2 CSs at any location in the installation site.
CS no. 1
CS no. 2
CS no. 3
CS no. 4
c. Make sure that the radio signal strength level is greater than "3" at any location in the
service area demanded by the user.
Display example:
When there is scan data
NO.1
CS No.2 LEVEL: 9
When there is no scan data
NO.0
NOT SAVED
178
Installation Manual
Display example:
When there is scan data
NO.1
CS No.2 LEVEL: 9
Installation Manual
179
2.9.6
OFF
1
2
3
4
5
6
180
Installation Manual
ON
2.9.7
CSIF8 Card
Port 1
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 444 m
Under 694 m
Under 1000 m
Under 694 m
Pin No.
1
2
3
4
Pin No.
1
2
3
4
5
6
7
8
Signal Name
D1
POWH
POWL
D2
Installation Manual
181
DHLC8 Card
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 222 m
Under 347 m
Under 500 m
Under 347 m
CS (RJ11)
Signal Name
D1
D2
Pin No.
1
2
3
4
DHLC/DLC card
(Amphenol)
Signal Name
D1
D2
182
Installation Manual
Connecting the CS
1. Connect the cable from the CSIF/DHLC/DLC card to the CS.
Modular
To CSIF/DHLC/DLC card
2. Pass the cable through the groove of the CS (in any direction depending on your
preference).
TO MAIN UNIT
/ PABX
To CSIF/DHLC/DLC card
Installation Manual
183
Registering the PS
The PS must be registered to the Hybrid IP-PBX before it can be used. Programming of both
the PS and Hybrid IP-PBX is required. A PT with multiline display (e.g., KX-T7636 6-line
display) is required for the Hybrid IP-PBX system programming.
Note
For details about system programming using a PT, refer to "2.3.2 PT Programming" and
"3.3 PT Programming" in the Feature Guide.
#
PROGRAM/
PAUSE
Programming No.
= 1234
3 digits
Press POWER
for 2 seconds.
Select
"PS PROGRAM".
Select
"SYSTEM SET".
If required
4 digits
S1
SEL
Select
"PS PROGRAM".
If required
SEL
Select
"SYSTEM SETTING".
S1
ENTR
Note
means default value throughout this section.
184
Installation Manual
S1
PS Registration
[690]
ENTER
PS No.
Extn. No.
001 to 128
1 to 4 digits
ENTER
To the PS
operation
below
END
[ F3 ]
Press S2 repeatedly
to select the desired
language.
Press S3
for 2
seconds.
C.Tone
Press
POWER for
2 seconds.
F3
Press S2 repeatedly
to select the desired
language.
Press S3
for 2
seconds.
C.Tone
Press
POWER for
2 seconds.
C.Tone
Choose
"SYSTEM 14".
Select
"REGISTRATION".
S1
SEL
Choose
"SYSTEM 14".
C.Tone
S1
Installation Manual
185
Choose
"Enable/Disable".
Select
"SYSTEM LOCK".
4 digits
4 digits
ENABLE
DISABLE
C.Tone
Select
"SYSTEM LOCK".
SEL
SEL
CHNG
S1
S1
Choose
"Enable/Disable".
ENTR
ENABLE
S1
DISABLE
ENTR
C.Tone
S1
186
Installation Manual
4 digits
S1
4 digits
By default, the PIN for PS registration is "1234" for both the Hybrid IP-PBX and PS.
Therefore, the PS can be registered to the Hybrid IP-PBX without setting the PIN.
The PIN for PS registration will only be used when registering the PS to the Hybrid
IP-PBX. Therefore, even when there is more than 1 Hybrid IP-PBX with the same PIN
near the PS, the PS will not be linked to a different Hybrid IP-PBX during normal
operation after registration.
Setting the PIN for Hybrid IP-PBX
[692]
1 to 4 digits
1234
ENTER
END
C.Tone
1 to 4 digits
1234
S1
ENTR
C.Tone
S1
Installation Manual
187
PS Termination
Confirm the following before cancelling the PS registration:
PS is turned on.
[691]
PS No.
001 to 128
ENTER
ENTER
YES
To the PS
operation
below
END
Press "YES".
Select "YES".
Select the
desired item.
Select "DELETE
SYSTEM".
C.Tone
S1
SEL
Select the
desired item.
S1
Select "YES".
SEL
C.Tone
S1
188
Installation Manual
2.9.8
Wall Mounting
1. Place the reference for wall mounting (on the following page) on the wall to mark the 2
screw positions.
Make sure that the screw heads are at the same distance from the wall.
Install the screws perpendicular to the wall.
Installation Manual
189
71 mm
Note
When you print out this page, the distance on the paper output may deviate slightly from
the measurement indicated above.
190
Installation Manual
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 70 m
Under 113 m
Under 180 m
Under 113 m
Doorphone
Door Opener
Pan
ason
ic
Screw
Installation Manual
191
2. Pass the wires through the hole in the base cover, and attach the base cover to a wall
using 2 screws.
Screw
Note
Two kinds of screws are included with a KX-T30865. Please choose the appropriate kind
for your wall type.
: when a doorphone plate has been fixed to the wall
: when you wish to install the doorphone directly onto the wall
Connection
Use 8-pin and 10-pin terminal blocks (included with the card) for connection.
1. While pressing down on the hole at the top of the terminal block using a screwdriver, insert
the wire into the side hole as shown below. Repeat this procedure for other doorphones
and door openers.
Refer to "2.6.2 DPH4 Card" and "2.6.3 DPH2 Card" for pin assignments.
Doorphone
Door Opener
192
Installation Manual
2. Attach the terminal blocks to the connectors of the DPH4/DPH2 card on the Hybrid IPPBX.
To doorphones/
door openers
Installation Manual
193
PC Server PC
BGM/
Music on Hold
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 10 m
Under 10 m
Under 10 m
Under 10 m
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 10 m
Under 10 m
Under 10 m
Under 10 m
USB
Pager:
Amplifier/Speaker
Maximum Distance
Under 2 m
PC
RS-232C
Printer
BGM/MOH
The Hybrid IP-PBX provides Background Music and Music on Hold. Up to 2 external music
sources (e.g., user-supplied radios) can be connected to the Hybrid IP-PBX.
CAUTION
Wiring should be done carefully to prevent undue force being exerted on the plug.
Otherwise, music may intermittent.
External Music Jacks are SELV ports and should only be connected to approved
SELV devices, or in Australia, via the Line Isolation Unit with the Telecommunications
Compliance Label.
Note
When the Hybrid IP-PBX and external music sources are not connected to the same
earth, hum noise may be induced into Background Music and Music on Hold.
194
Installation Manual
Pager
Up to 2 paging devices (user-supplied) can be connected to the Hybrid IP-PBX.
CAUTION
External Paging Jacks are SELV ports and should only be connected to approved SELV
devices, or in Australia, via the Line Isolation Unit with the Telecommunications
Compliance Label.
Pin Assignments
Circuit Type
No.
6
Signal Name
Function
EIA
CCITT
RD (RXD)
Receive Data
BB
104
3
4
SD (TXD)
ER (DTR)
Transmit Data
Data Terminal Ready
BA
CD
103
108.2
5
6
SG
DR (DSR)
Signal Ground
Data Set Ready
AB
CC
102
107
7
8
RS (RTS)
CS (CTS)
Request To Send
Clear To Send
CA
CB
105
106
Connection Charts
For connecting a printer/PC with a 9-pin RS-232C connector
Hybrid IP-PBX
Printer/PC
Circuit Type
(EIA)
Signal
Name
Pin No.
Pin No.
Signal
Name
Circuit Type
(EIA)
BB
RD (RXD)
RD (RXD)
BB
BA
SD (TXD)
SD (TXD)
BA
CD
ER (DTR)
ER (DTR)
CD
AB
SG
SG
AB
CC
DR (DSR)
DR (DSR)
CC
CA
RS (RTS)
RS (RTS)
CA
CB
CS (CTS)
CS (CTS)
CB
Installation Manual
195
Hybrid IP-PBX
Printer/PC
Circuit Type
(EIA)
Signal
Name
Pin No.
Pin No.
Signal
Name
Circuit Type
(EIA)
BB
RD (RXD)
FG
AA
BA
SD (TXD)
RD (RXD)
BB
CD
ER (DTR)
SD (TXD)
BA
AB
SG
20
ER (DTR)
CD
CC
DR (DSR)
SG
AB
CA
RS (RTS)
CS (CTS)
CB
CB
CS (CTS)
DR (DSR)
CC
RS (RTS)
CF
RS-232C Signals
196
Installation Manual
Pin Assignments
No.
Signal Name
VBUS
USB D-
USB D+
GND
Installation Manual
197
Analogue trunk cards: LCOT16 (4 PFT ports), LCOT8 (2 PFT port), and LCOT4 (2
PFT port)
Extension cards: MSLC16 (4 PFT ports), SLC16 (4 PFT ports), DHLC8 (2 PFT port)
and SLC8 (2 PFT port)
To 1 analogue trunk card, connect only 1 extension card.
Note
By programming the Hybrid IP-PBX, a trunk conversation established during power failure
can be maintained even when the power returns and the connection is switched back to
the normal configuration from the Power Failure Connection. However, if no special
programming is performed, the connection will be dropped when power returns.
RJ11
R2
R1
T1
T2
T2
T1
R1
R2
Extension Card
(e.g., SLC8)
Trunk Card
(e.g., LCOT8)
To trunk
198
Installation Manual
To SLT
1
4
Function
R2
Ring port 2
R1
Ring port 1
T1
Tip port 1
T2
Tip port 2
1
4
Function
R4
Ring port 4
R3
Ring port 3
T3
Tip port 3
T4
Tip port 4
1
4
Function
T2
Tip port 2
T1
Tip port 1
R1
Ring port 1
R2
Ring port 2
1
4
Function
T4
Tip port 4
T3
Tip port 3
R3
Ring port 3
R4
Ring port 4
Installation Manual
199
RJ45
(LINE 2)
Set all DIP switches
at "ON" positions.
To ISDN extension
To NT1
RJ45
(LINE 1)
OFF
OFF
ON
ON
Switch Settings
Switch
Type
PFT Setting
DIP
200
Installation Manual
Level [V]
Function
1-2 Reserved
TX1
(+)
Transmit data 1
RX2
(+)
Receive data 2
RX1
(-)
Receive data 1
TX2
(-)
Transmit data 2
7-8 Reserved
Level [V]
Function
1-2 Reserved
RX2
(+)
Receive data 2
TX1
(+)
Transmit data 1
TX2
(-)
Transmit data 2
RX1
(-)
Receive data 1
7-8 Reserved
Installation Manual
201
SD Memory Card must be inserted in the SD Memory Card slot of the MPR card
before start up.
Before touching the System Initialise Switch and the Reset Button, discharge static
by touching ground or wearing an earthing strap.
Once you have started the Hybrid IP-PBX and if you unplug the Hybrid IP-PBX, do
not perform the following procedures to start the Hybrid IP-PBX again. Otherwise,
your programmed data is cleared. To restart the Hybrid IP-PBX, refer to "4.1.4 Using
the Reset Button".
The Hybrid IP-PBX will continue to be powered even if the power switch is turned
"OFF".
The power supply cord is used as the main disconnect device, ensure that the socketoutlet is located/installed near the equipment and is easily accessible.
RESET
SYSTEM
INITIALIZE
NORMAL
202
Installation Manual
2. Plug the AC power cord into the Hybrid IP-PBX and an AC outlet, and turn on the Hybrid
IP-PBX.
Note
For safety reasons, do not stretch, bend, or pinch the AC power cord.
To AC Outlet
3. Press the Reset Button with a pointed tool. (The RUN indicator will flash.)
4. While the RUN indicator is flashing (within about 10 s), return the System Initialise Switch
to the "NORMAL" position. Depending on the configuration, initialisation takes about 1 min
to 3 min. If successfully executed, the RUN indicator will stop flashing and be kept lit.
All data will be cleared, and the Hybrid IP-PBX as well as all optional service cards (except for
the IP-GW card) will be initialised to the default values. The DPTs should show the time as
01:00.
The data of the IP-GW card will not be initialised.
Notes
Use only the AC power cord included with the Hybrid IP-PBX for the PSU.
Use only the supplied AC power cord for the purpose of applying the EMC standard,
if the Hybrid IP-PBX is connected (Germany only).
LED Indications
Indication
Colour
Description
RUN
Green
ALARM
Red
Alarm indication
OFF: Normal
Installation Manual
203
204
Installation Manual
Section 3
Guide for the KX-TDA Maintenance Console
KX-TDA100/KX-TDA200
Installation Manual
205
3.1
Overview KX-TDA100/KX-TDA200
3.1.1
Overview
KX-TDA Maintenance Console is designed to serve as an overall system programming
reference for the Hybrid IP-PBX. To programme and administer the Hybrid IP-PBX by PC, you
need to install the KX-TDA Maintenance Console onto the PC.
This manual describes overview and installation of the KX-TDA Maintenance Console only.
KX-TDA Maintenance Console*1
Menu Bar
Programme Menu
*1
The contents and design of the software are subject to change without notice.
206
Installation Manual
3.2
Connection KX-TDA100/KX-TDA200
3.2.1
Connection
To USB Port
PC
To COM Port
PC
RS-232C Port
Note
For pin assignments and maximum cabling distance, refer to "2.11.1 Connection of
Peripherals".
RJ45
Switching Hub
To network port
PC
Note
For pin assignments and maximum cabling distance, refer to "2.6.6 CTI-LINK Card".
Installation Manual
207
Modem
To RS-232C port (25-pin)
External Modem
RS-232C Port
(9-pin)
Hybrid IP-PBX
Signal Name
Pin No.
Pin No.
Signal Name
SD (TXD)
RD (RXD)
RD (RXD)
SD (TXD)
DR (DSR)
ER (DTR)
ER (DTR)
20
DR (DSR)
After connecting the Hybrid IP-PBX and the external modem, set the power switch of the
external modem to "ON", then the external modem will be initialised with the default values.
The following AT command settings may be required for the modem:
The Data Terminal Equipment (DTE)/Modem flow control should be turned off.
208
Installation Manual
Use an RS-232C straight cable for connection between the Hybrid IP-PBX and
external modem.
An AT command (for initialisation, enabling automatic answer, etc.) can only be
programmed by KX-TDA Maintenance Console. "AT&F0E0V1X1S10=30S12=50" is
stored as the default value.
For more information about the AT command, refer to the external modem's
instructions.
3.3
3.3.1
System Requirements
Operating System
Password Security
A password is required to perform programming for security purposes. Do not disclose the
password. This will avoid unauthorised access and possible dial through fraud.
Warning to the Administrator regarding the system password
1. Please inform the customer of the importance of the password and the possible
dangers.
2. Please maintain the secrecy of the password. This will avoid unauthorised access and
possible dial through fraud.
5. If the system password is forgotten, you can examine the backup of the system
Installation Manual
209
2. a.
b.
c.
d.
e.
Notes
Date and Time of the Hybrid IP-PBX. The date and time set on the PC will be used.
Operator extension numbers. Operator extensions for all time modes (day/lunch/
break/night) can be assigned.
210
Installation Manual
Flexible Numbering type to pattern 1 or pattern 2. If pattern 1 (with ) is selected, " "
must prefix all feature numbers (except access numbers) when an extension user
wants to use a feature.
Operator call and Idle Line Access/ARS numbers (0 or 9). The feature numbers for
operator call and Idle Line Access/ARS can be selected.
Remote Maintenance Dial Number. Enter the complete telephone number of the PBX
(including the country code). When necessary, this number will be used to access the
PBX from a remote location for maintenance purposes.
Installation Manual
211
Notice
2. When the PBX is initialised, not all data is taken from the SD Memory Card. The data
for present status of extension FWD/DND buttons is taken from battery backup
memory in the PBX.
3. The PC will not perform any shutdown operation, or enter the power-saving system
standby mode while the KX-TDA Maintenance Console is connected to the Hybrid IPPBX. To perform either of the operations above, first close the connection to the
Hybrid IP-PBX.
CAUTION
Do not remove the SD Memory Card during access to it. Doing so will damage the system
data, and in the worst case, damage the SD Memory Card.
212
Installation Manual
3.3.2
Menu Bar
File
Connect
Tool
Utility
Diagnosis
File Transfer PC to PBX (SD Card)
File Transfer PBX (SD Card) to PC
SD Card File View and Load
SD Card File Delete
Message File Transfer PC to PBX
Message File Transfer PBX to PC
Error Log
T1/E1 Signaling Bit Monitor
T1/E1 Line Trace
ISDN/QSIG Protocol Trace
Digital Trunk Error Report
CS Information
PS Information
Timed Update
System Reset
Window
Help
Installation Manual
213
3.3.3
a. Double-click "Configuration".
b. Double-click "Slot".
a. Double-click "Configuration".
b. Double-click "Portable Station".
214
Installation Manual
3.3.4
3. a.
Installation Manual
215
216
Error Log
CS Information
PS Information
Timed Update
Installation Manual
System Reset
Reset by the Command
Installation Manual
217
218
Installation Manual
Section 4
Troubleshooting KX-TDA100/KX-TDA200
Installation Manual
219
4.1
Troubleshooting KX-TDA100/KX-TDA200
4.1.1
Installation
PROBLEM
PROBABLE CAUSE
Bad extension card.
SOLUTION
Exchange the card for a known working one.
Bad connection between the Take the telephone and plug it into the same
Hybrid IP-PBX and
extension port using a short telephone cord.
telephone.
If the telephone works, then the connection
between the Hybrid IP-PBX and the
telephone must be repaired.
A telephone with an A-A1
relay is connected.
Bad telephone.
Improper operation.
Alternate CallingRing/Voice
and Live Call Screening
(LCS) do not function as set
when using a Wireless Phone
(KX-T7880/KX-T7885/KXTD7894/KX-TD7895).
A major system error occurs See the error log using the KX-TDA
in the Hybrid IP-PBX.
Maintenance Console (refer to "4.1.5
Troubleshooting by Error Log").
220
Installation Manual
4.1.2
Connection
Connection between the Hybrid IP-PBX and a PT:
CAUSE
No
SOLUTION
D1
T
R
D2
Hybrid IP-PBX
Extension
CAUSE
SOLUTION
T
R
Hybrid IP-PBX
Yes
Extension
CAUSE
SOLUTION
T
R
Extension
Installation Manual
221
CAUSE
Trunk is connected to the T2/T1.
T2
R1
T1
R2
No
Trunk
Hybrid IP-PBX
222
Installation Manual
Hybrid IP-PBX
SOLUTION
Reconnect the trunk to
the T1/R1 or T2/R2 of the
telephone jack using
2-conductor wiring.
4.1.3
Operation
PROBLEM
PROBABLE CAUSE
SOLUTION
The HANDSET/
HEADSET selector is
set to the "HEADSET"
position.
A DPT or APT is
connected to the
extension port.
Originating an outside
call, call transfer, or
conference cannot be
performed.
The corresponding CO
button does not exist on
the PT.
Wrong Personal
Identification Number
(PIN) is registered to the
PS.
Register the PIN set to the Hybrid IPPBX into the PS.
CS is not connected
properly.
Installation Manual
223
PROBLEM
PROBABLE CAUSE
PS becomes out of
range.
Cannot make calls using
the PS.
SOLUTION
CS is not working.
224
Location of CS is not
good.
working.
PS is out of CS coverage
area.
Installation Manual
4.1.4
1. When the System Initialise Switch is set to "NORMAL", pressing the Reset Button
causes the following:
Camp-on is cleared.
2. When the System Initialise Switch is set to the "SYSTEM INITIALIZE" position, you
must press the Reset Button with caution, because all data stored in memory will be
cleared by the following operation: (1) pressing the Reset Button and then, (2) setting
the System Initialise Switch to the "NORMAL" position while the RUN indicator is
flashing (within approximately 10 s).
Operation
1. If the Hybrid IP-PBX does not operate properly:
a. Make sure that the System Initialise Switch is set to the "NORMAL" position.
b. Press the Reset Button.
RUN Indicator
Reset Button
RESET
SYSTEM
INITIALIZE
NORMAL
225
226
Installation Manual
4.1.5
Description
Item
Description
Date
Time
Level
Error Code
Installation Manual
227
Item
5
Sub Code
Description
Five-digit sub code (1XXYY)
1: Cabinet number
XX: Slot number
KX-TDA100: 00 to 06 (00: MPR slot; 01 to 05: Free slot; 06:
Option slot)
KX-TDA200: 00 to 11 (00: MPR slot; 01 to 10: Free slot; 11:
Option slot)
YY: Physical port number (01 to 16)
For OPB3 card, sub slot number + port number will be
displayed.
Sub slot 1: 11 to 14
Sub slot 2: 21 to 24
Sub slot 3: 31 to 34
Note
When there is no parameter for slot and physical port
number, XX and YY will be displayed as "00".
Example: Sub code for MPR card = 10000
228
Error Message
Installation Manual
When the errors "021", "091", "092", and "510" are logged: when the error
conditions are recovered
When other errors are logged: when the log for major or minor errors is cleared from
the KX-TDA Maintenance Console
LPR (Optional Service Card with Local Processor) Initial Self Diagnosis
Error Code
211
Error Message
Speech path
loop-back check
error
PROBABLE CAUSE
SOLUTION
212
Echo canceller
access error
214
215
Framer IC access
error
216
217
Erroneous recording of
messages
Installation Manual
229
Error Message
000*
MPR WDT
overflow
001
PROBABLE CAUSE
002
System Restart
010*
AC power down
011*
DC power down
SOLUTION
Reset Button is
pressed
Power failure
MPR card malfunction
Erroneous processing
of MPR card software
Software error due to
external factors
AC power down
Power supply circuit
(PSU, back board)
malfunction
Detection of over
current (short circuit on
optional service cards)
012*
230
MPR RAM
battery low
Installation Manual
Battery out
Error Code
Error Message
PROBABLE CAUSE
SOLUTION
014*
FAN Alarm
PSU-L malfunction
016
CS overload
Defective cable
CS malfunction
Optional service card
malfunction: CSIF
017
Defective cable
Defective ISDN
terminal equipment
Optional service card
malfunction: BRI
020*
SD file access
error
021*
SD Memory Card
disconnected
022
SD Memory Card
malfunction
Bad connection of SD
Memory Card
MPR card malfunction
SD Memory Card not
installed
Bad connection of SD
Memory Card
SD Memory Card
malfunction
MPR card malfunction
Note
Do not delete the "PMPR" file; it is the
programme file of the MPR card.
Installation Manual
231
Error Code
Error Message
PROBABLE CAUSE
023
024
System
initialization file
version error
025
Card initialization
file version error
026
027
028
System
initialization file
checksum error
029
Card initialization
file checksum
error
030
LCD file
checksum error
031*
032*
System
initialization file
not found
SOLUTION
033*
Card initialization
034*
035
036*
System
initialization file
access error
037*
Card initialization
file access error
038*
090
Over Card
Limitation
091*
PT connection
over
092*
CS connection
over
232
Installation Manual
Error Code
Error Message
PROBABLE CAUSE
200
201*
202*
203*
204*
205*
206
207
230*
Card
disconnected
SOLUTION
231
232
MPR-LPR
communication
error
233
234
235*
CS clock failure
Installation Manual
233
Error Code
Error Message
PROBABLE CAUSE
SOLUTION
250*
251
300*
301*
reception
302*
303*
Multiframe out of
synchronization
304*
Frame error
306
E1 Channel Block
failure
308
234
Installation Manual
connector; 75
when using BNC
connector
See if the corresponding optional
service card is installed properly
Replace the corresponding optional
service card
Check the connection between the CS
and CSIF card or DHLC/DLC card
Check the connection between the
network and PRI/BRI card
Check the connection between the
network and IP-GW card
LAN No Carrier
307
305*
connector; 75
when using BNC
connector
See if the corresponding optional
service card is installed properly
Replace the corresponding optional
service card
Detection of IP-GW
LAN Loop back Test
error
Error Code
Error Message
PROBABLE CAUSE
SOLUTION
309
Detection of IP-GW
Core data Link error
310*
Voice Processing
System malfunction
Ports defective on
optional service card:
DHLC, DLC
IP-GW H.323
Detection of IP-GW
H.323 Dummy Call
Test error
IP-GW
Gatekeeper Error
Detection of
Gatekeeper access
error
320
321
322
IP-GW
Gatekeeper
Registration Error
Gatekeeper
Registration is failed
323
IP-GW SDRAM
Failure
Detection of IP-GW
SDRAM error
324
IP-GW DPRAM
Failure
Detection of IP-GW
DPRAM error
325
Detection of IP-GW
LAN Chip failure
326
IP-GW Stop
370
371
IP-GW Rebooted
by Maintenance
Console
IP-GW is rebooted
from a remote
maintenance PC
IP-GW Rebooted
390
Digital signal
synchronization
established
Synchronisation of
digital line established
or restored
Installation Manual
235
Error Code
Error Message
PROBABLE CAUSE
SOLUTION
391
Data Link
established
Connection with PC
Phone/PC Console or
Voice Processing
System (DPT
Integration)
established or restored
392
393
LAN Carrier
detected
394
395
IP-GW
Gatekeeper Error
Cleared
Connection to the
Gatekeeper is
recovered
396
IP-GW Run
510*
SMDR disconnect
236
Installation Manual
Section 5
System Outline KX-TDA30
Installation Manual
237
5.1
5.1.1
System Highlights
Networking Features
This Hybrid IP-PBX supports the following networking features:
Virtual Private Network (VPN)
VPN is a service provided by the telephone company. It uses an existing line as if it were
a private line.
Voice over Internet Protocol (VoIP) Network
The PBX can connect to another PBX via a private IP network. In this case, voice signals
are converted into IP packets and sent through this network.
238
Installation Manual
Installation Manual
239
5.2
5.2.1
Main Unit
The main unit is equipped with 4 Super Hybrid Ports. For system expansion, optional service
cards can be installed, and an additional AC adaptor can also be connected.
Front Cover
240
Installation Manual
Main Board
Cable Cover
5.2.2
Private
IP Network
Hybrid IP-PBX
Router
Batteries
PC
Printer
Server PC
SLT
SLT
Fax Machine
Wireless Phone
PC
PC
DPT
APT
DSS Console
DPT
DSS Console
ISDN Telephone
CS
USB
KX-T7636/
KX-T7633
Pager/ Amplifier
Speaker
PC
Voice Processing
System
KX-T7600 DPT
KX-T7600 DPT
Installation Manual
241
Hybrid IP-PBX
Telephone
Company
Analogue
Trunk
LCOT4
(KX-TDA3180)
DLC8
(KX-TDA3172)
CID4
(KX-TDA3193)
DLC4
(KX-TDA3171)
DPT
KX-T7636/KX-T7633
LCOT2
(KX-TDA3183)
SLC8
(KX-TDA3174)
PT-interface CS
PC
DSS
Console
Voice
Processing
System
PS
SLC4
(KX-TDA3173)
BRI2
(KX-TDA3280)
DPH4
(KX-TDA3161)
IP-GW4
(KX-TDA3480)
Private
IP Network
DPH2
(KX-TDA3162)
SLT
Wireless Phone
Fax Machine
Router
MSG2
(KX-TDA3191)
Amplifier
Batteries
MEC
(KX-TDA3105)
RMT
(KX-TDA3196)
Pager/Speaker
Radio
ECHO8
(KX-TDA3166)
Server PC
AC Cord & AC Adaptor*1
Station Message
Detail Recording (SMDR)
EXT-CID
(KX-TDA3168)
APT
SLT
PC
DPT
DSS Console
Voice
Processing
System
PT-interface CS PS
Main Board
*1
*2
242
In addition to the supplied AC adaptor, an additional AC adaptor can be connected to the Hybrid IPPBX.
The Hybrid IP-PBX has 4 Super Hybrid Ports pre-installed.
Installation Manual
5.3
Options KX-TDA30
5.3.1
Options
Model No.
Model Name
Maximum
Quantity
Description
KX-TDA3105
KX-TDA3161
KX-TDA3162
KX-TDA3166
KX-TDA3168
KX-TDA3171
KX-TDA3172
KX-TDA3173
KX-TDA3174
KX-TDA3180
4-Port Analogue Trunk Card 4-port analogue trunk card with 2 power
(LCOT4)
failure transfer (PFT) ports.
KX-TDA3183
2-Port Analogue Trunk Card 2-port analogue trunk card with 2 power
(LCOT2)
failure transfer (PFT) ports.
KX-TDA3191
KX-TDA3193
Installation Manual
243
Model Name
KX-TDA3196
KX-TDA3280
KX-TDA3480
KX-A236
Additional AC Adaptor
244
Installation Manual
Description
Maximum
Quantity
Model No.
5.4
Specifications KX-TDA30
5.4.1
General Description
Switching
AC Adaptor
Non-blocking
AC Input
DC Output
40 V, 1.38 A (55.2 W)
DC Input
External Battery
7 years
Dialling
Trunk
Extension
Trunk
Extension
Paging Output
1 conductor jack
Connectors
DC IN 1: 40 V, 1.38 A (55.2 W)
DC IN 2: 40 V, 1.38 A (55.2 W)
1 conductor jack
External MOH
(Music on Hold)
Output
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
1600
Operating
Environment
Temperature
0 C to 40 C
Humidity
10 % to 90 % (non-condensing)
maximum
Music on Hold
Paging
Internal
External
Installation Manual
245
SLT
DPT
APT
PT-interface CS
DSS Console and Add-on Key Module 1-pair wire (D1, D2)
Dimension
Under 3.5 kg
246
Installation Manual
5.4.2
Characteristics
SLT: 600
Doorphone: 20
PT-interface CS: 65
15 000
including set
minimum
1600
Hookswitch Flash/Recall
Timing Range
24 ms to 2032 ms
Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 5 W per 2 lines
Power Supply Method: Phantom Power Supply
600
10 000
maximum
Installation Manual
247
5.4.3
System Capacity
Maximum Number
Trunk Line
12
VoIP Line
Without Additional AC
Adaptor
Without MEC Card
SLT
KX-T7600 series DPT and KXT7560/KX-T7565 DPT
24
Total 24
Total 24
Total 48
24
24
48
KX-T7560/KX-T7565 DPT
24
24
Total 4
Total 24
Other DPT
24
APT
CS
PS
28
28
4 ports (1 VPS)*1
4 ports (1 VPS)*1
VPS
SLT, PT, CS, and VPS
Total 28
Total 28
Total 52
Doorphone
Door Opener
Total 24
Total 48
USB Module
*1
A maximum of 4 ports (8 channels) of a single VPS can be connected to the Hybrid IP-PBX.
Note
Devices connected to the Hybrid IP-PBX that exceed the system capacity will not function.
248
Installation Manual
MEC Figure
KX-T7560/KX-T7565 DPT
APT
SLC4
SLC8
Extension Card*1
CS (1 unit)
VPS (1 port)
ISDN Telephone
*1
Only the extension cards that can support SLTs count for the MEC figures.
Calculation Example
Equipment Type
MEC Figure
16 units
16
SLC4
1 card
SLC8
1 card
VPS
4 ports
Total
32
The total MEC figure is 32. As this exceeds 28, you need to install an MEC card for this
configuration.
A total of more than 4 APTs and DPTs (except KX-T7600 series, KX-T7560/KX-T7565)
are connected.
Installation Manual
249
A total of more than 4 APTs and DPTs (except KX-T7600 series, KX-T7560/KX-T7565)
are connected.
Load Figure
KX-T7560/KX-T7565 DPT
APT
SLC4
SLC8
Extension Card*1
CS (1 unit)
VPS (1 port)
ISDN Telephone
*1
*2
1*2
Only the extension cards that can support SLTs count for the load figures.
If the connected ISDN telephone has an external power source, its load figure is 0.
AC Adaptor Capability
The following load figures can be supported.
Connected AC Adaptor
Supplied AC Adaptor only
Supplied AC Adaptor and Additional AC Adaptor
*1
250
If the load figure exceeds 96, it cannot be supported by the KX-TDA30. In this case, use the KX-TDA100 with MType Power Supply Unit (PSU-M), or the KX-TDA200 with either PSU-M or L-Type Power Supply Unit (PSU-L).
Installation Manual
Calculation Example
Equipment Type
Load Figure
4 units
16
CS
3 units
12
ISDN Telephone
5 units
Total
33
The total load figure is 33. As this exceeds 32, you need to connect an additional AC adaptor.
Installation Manual
251
252
Installation Manual
Section 6
Installation KX-TDA30
Installation Manual
253
6.1
6.1.1
Before Installation
Please read the following notes concerning installation and connection before installing the
Hybrid IP-PBX. Be sure to comply with applicable local regulations (e.g., law, guidelines).
3. Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Installation Precautions
This set is made for wall mounting. Avoid installing in the following places. (Doing so may result
in malfunction, noise, or discolouration.)
2. Sulphuric gases produced in areas where there are thermal springs, etc. may damage the
equipment or contacts.
3.
4.
5.
6.
7. Closer than 1.8 m to radios and televisions (both the Hybrid IP-PBX and PTs).
8. Do not obstruct the area around the Hybrid IP-PBX (for reasons of maintenance and
inspectionbe especially careful to allow at least 20 cm above and 10 cm at the sides of
the Hybrid IP-PBX for cooling).
Wiring Precautions
Be sure to follow these instructions when wiring.
1. Do not wire the telephone cable in parallel with an AC power source, computer, telex, etc.
If the cables are run near those wires, shield the cables with metal tubing or use shielded
cables and ground the shields.
2. If cables are run on the floor, use protectors to prevent the wires from being stepped on.
Avoid wiring under carpets.
254
Installation Manual
3. Avoid using the same power supply outlet for computers, telexes, and other office
equipment. Otherwise, the Hybrid IP-PBX operation may be interrupted by the inducted
noise from such equipment.
4. Please use 1-pair telephone wire for extension connection of (telephone) equipment such
as standard telephones, data terminals, answering machines, computers, Voice
Processing Systems, etc., except PTs (e.g., KX-T7600 series).
5. The power switch of the Hybrid IP-PBX must be off during wiring. After the wiring is
completed, turn the power switch on.
8. The Hybrid IP-PBX is equipped with a 3-wire earthing type plug. This is a safety feature.
If you are unable to insert the plug into the outlet, contact your electrician to replace your
obsolete outlet. Do not defeat the purpose of the earthing-type plug.
Installation Manual
255
6.2
6.2.1
Unpacking
Unpack the box and check the items below:
256
Main Unit
AC Cord
AC Adaptor
SD Memory Card
Main Strap
Installation Manual
6.2.2
SD Memory
Card Slot Cover
Reset Button
System Initialise
Switch
MOH port
Pager port
Earth Terminal
Battery Connector
DC IN 2
DC IN 1
Super Hybrid
Ports
RS-232C port
USB port
Power Switch
Installation Manual
257
6.2.3
Slide Button
Cable Cover
3. Holding the protrusions on both sides of the front cover, swing the cover open.
258
Installation Manual
Installation Manual
259
2. Attach the rear hooks on the cable cover to the main unit, then swing the cable cover
closed so that the front hooks fit in place.
Cable Cover
260
Installation Manual
6.2.4
LED
SD Memory Card
Slot Cover
SD Memory
Card
CAUTION
Use only the SD Memory Card included with the Hybrid IP-PBX.
The SD Memory Card contains software for all the processes of the Hybrid IP-PBX
and all the customer data. The SD Memory Card must be inserted before start up.
Do not remove the SD Memory Card during the operation of the Hybrid IP-PBX.
Removing the SD Memory Card during operation may cause damage to the SD
Memory Card, or result in loss of data.
LED Indications
Indication
Colour
Description
SD ACCESS
Green
ON: Accessing
Note
If you need to remove the SD Memory Card:
Installation Manual
261
6.2.5
Screw
supplied)*.
Earthing
wire
To earth
* For earthing wire, green-and-yellow insulation is required, and the cross-sectional area of
the conductor must be more than 0.75 mm2 or 18 AWG.
262
Installation Manual
6.2.6
Battery Connector
Back-up Battery Cable
Fuse
Power Switch
Red
Black
Turn on the power switch of the Hybrid IP-PBX only after the installation of the Hybrid IPPBX is finished and AC power is available.
For each backup battery, battery capacity of 14 Ah or below is recommended (otherwise,
the battery charge may not be maintained).
Make sure that the type and capacity of the 3 backup batteries are identical.
The Back-up Battery Cable should not be exposed to direct sunlight. Keep the Back-up
Battery Cable and the backup batteries away from heating appliances and fire. Place the
backup batteries in ventilated place.
For details about the backup batteries, refer to the manual intended for the batteries.
CAUTION
Installation Manual
263
6.2.7
Slot Position
11*1
10*1
04
07
09
03
06
08
02
05
01*2
*1
*2
Slots 10 and 11 accept only cards which do not have external ports. Therefore, these
slots do not have removable cover plates.
Slot 01 contains the pre-installed Super Hybrid Ports. No optional service card can be
installed.
Slot Restrictions
The following table shows the slot restrictions. "
service card.
Card
Type
Slot Number
Max
LCOT4
LCOT2
BRI2
DLC4
1*1
SLC4
IP-GW4
DLC8
2*2
SLC8
DPH4
1*3
DPH2
264
ECHO8
EXT-CID
MSG2
Installation Manual
02
03
04
05
06
07
08
09
10
11
*1
*2
*3
CAUTION
To protect the main board from static electricity, do not touch parts on the main board or
on the optional service cards. To discharge static electricity, touch ground or wear an
earthing strap.
Notes
When installing or removing the optional service cards, the power switch of the Hybrid
IP-PBX must be in the off position.
For each card, the maximum number that can be installed in the Hybrid IP-PBX is
listed in "5.3.1 Options".
Any card that exceeds the capacity of the Hybrid IP-PBX will be ignored.
When the Hybrid IP-PBX starts up with an invalid configuration, some cards will be
ignored.
CAUTION
For safety reasons, smooth the cut edges after removing the dummy cover plates.
Installation Manual
265
2. Position the card in the open slot, making sure that the tabs on the both sides of the card
fit into place. Then, holding the card firmly in place, lower the rear end so that the hole of
the card fits over the extension bolt.
1
2
Extension Bolt
CAUTION
When installing the optional service cards, do not put pressure on any parts of the main
board. Doing so may result in damage to the Hybrid IP-PBX.
3. Insert the new extension bolt (included with the card) into the hole on the card, and tighten
it to secure the card.
Extension Bolt
266
Installation Manual
4. Stick an appropriate optional card label (included) to the left side of the corresponding
card.
Note
Make sure to connect cables after installing the card in the Hybrid IP-PBX, not before.
Installation Manual
267
LED holder
268
Installation Manual
B. When installing a card in Slot 11, tighten the card using the screw included with the
card, instead of the extension bolt.
Screw
Installation Manual
269
Strap
270
Installation Manual
4. Attach the main strap (included with the Hybrid IP-PBX) to any of the 5 rails
depending on your preference.
2
1
Main Strap
Installation Manual
271
5. Bind all the connected cables together using the main strap, and then close the cable
cover. For how to close the cable cover, refer to "6.2.3 Opening/Closing the Covers".
Cable Cover
Main Strap
Notes
272
Installation Manual
2. Holding the protrusions of the card, pull the card in the direction of the arrows.
CAUTION
When removing the optional service cards, do not put pressure on any parts of the main
board. Doing so may result in damage to the Hybrid IP-PBX.
Installation Manual
273
6.2.8
Types of Connectors
Connector Type
Pin Number
Used for
RJ45
1
RJ11
4
10-pin
8-pin
Terminal Block Terminal Block
RS-232C
DPH4 (KX-TDA3161NE)
DPH2 (KX-TDA3162)
DLC4 (KX-TDA3171NE)
DLC8 (KX-TDA3172NE)
SLC4 (KX-TDA3173NE)
SLC8 (KX-TDA3174NE)
LCOT4 (KX-TDA3180NE)
LCOT2 (KX-TDA3183)
BRI2 (KX-TDA3280)
IP-GW4 (KX-TDA3480)
DPH4 (KX-TDA3161)
DLC4 (KX-TDA3171)
DLC8 (KX-TDA3172)
SLC4 (KX-TDA3173)
SLC8 (KX-TDA3174)
LCOT4 (KX-TDA3180)
DPH4 (KX-TDA3161)
DPH2 (KX-TDA3162)
Main Board
Main Board
10
USB
2
Mini Plug
+
-
*1
274
The KX-TDA30E, the KX-TDA30NE, and the KX-TDA30GR have the Super Hybrid Ports with RJ45 connectors.
Installation Manual
*2
Other models of the KX-TDA30 (other than the KX-TDA30E, the KX-TDA30NE, and the KX-TDA30GR) have the
Super Hybrid Ports with RJ11 connectors.
Installation Manual
275
6.2.9
130 mm
250 mm
Make sure that the screw heads are at the same distance from the wall.
Install the screws perpendicular to the wall.
Notes
276
Installation Manual
Do not block the openings of the cabinet. Allow space of at least 20 cm above and 10
cm at the sides of the cabinet.
Make sure that the wall behind the cabinet is flat and free of obstacles, so that the
openings on the back of the cabinet will not be blocked.
Be careful not to drop the cabinet.
1. Place the reference for wall mounting (on the last page of this manual) on the wall to mark
the 3 screw positions.
130 mm
250 mm
Anchor Plug
6.4 mm
29 mm
Installation Manual
277
Notes
278
Installation Manual
Do not block the openings of the cabinet. Allow space of at least 20 cm above and 10
cm at the sides of the cabinet.
Make sure that the wall behind the cabinet is flat and free of obstacles, so that the
openings on the back of the cabinet will not be blocked.
Be careful not to drop the cabinet.
110 mm
Make sure that the screw heads are at the same distance from the wall.
Install the screws perpendicular to the wall.
Note
Be careful not to drop the AC adaptor.
Installation Manual
279
1. Place the reference for wall mounting (on the following page) on the wall to mark the 2
screw positions.
110 mm
Anchor Plug
6.4 mm
29 mm
Note
Be careful not to drop the AC adaptor.
280
Installation Manual
110 mm
Note
When you print out this page, the distance on the paper output may deviate slightly from
the measurement indicated above.
Installation Manual
281
KX-A207
TELESPIKE BLOK MODEL TSB (TRIPPE MFG. CO.)
SPIKE BLOK MODEL SK6-0 (TRIPPE MFG. CO.)
Krone 237A strips fitted with 14A/1 surge arrestors
Super MAX (PANAMAX)
MP1 (ITW LINK)
Installation
Trunk
Trunk
Trunk
Lightning
Protectors
Terminal
Board
Extn.
Hybrid
IP-PBX
282
Installation Manual
PT
CS
Frame
Earth
Extn.: Extension line
Outside Installation
(Main Building)
Lightning Protectors
Trunk
(Another Building)
Trunk
SLT
Terminal
Board
Extn.
SLT
Hybrid
IP-PBX
Extn.
Extn.
Lightning
Protector
PT
CS
Extn.
PT
CS
Earth
Extn.: Extension Line
If you install an extension outside of the building, the following precautions are recommended:
Earthing
Wire
Hybrid
IP-PBX
(Underground)
Earth Rod
Installation Manual
283
2.
3.
4.
5.
Check obstructions.....None
Composition of the earth rod.....Metal
Depth of the earth rod.....More than 50 cm
Cross sectional area of the earthing wire.....More than 1.3 mm2
Notes
284
Installation Manual
6.3
6.3.1
LCOT4 Card
Function
4-port analogue trunk card with 2 power failure transfer (PFT) ports. One CID4 card can be
mounted on the LCOT4 card (refer to "6.3.3 CID4 Card").
PFT Port 2
PFT Port 1
RJ45
To trunk
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "6.12.1
Starting the Hybrid IP-PBX".
For details about power failure transfer, refer to "6.11.1 Power Failure Connections".
Pin Assignments
RJ45 Connector
TR
TR
16
Signal Name
Function
Ring
Tip
Reserved
Installation Manual
285
RJ11 Connector
TR
286
Installation Manual
Signal Name
Function
Ring
Tip
Reserved
6.3.2
LCOT2 Card
Function
2-port analogue trunk card with 2 power failure transfer (PFT) ports.
PFT Port 2
PFT Port 1
RJ45
To trunk
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "6.12.1
Starting the Hybrid IP-PBX".
For details about power failure transfer, refer to "6.11.1 Power Failure Connections".
Pin Assignments
RJ45 Connector
TR
TR
16
Signal Name
Function
Ring
Tip
Reserved
Installation Manual
287
6.3.3
CID4 Card
Function
4-port Caller ID signal type FSK/FSK (with Call Waiting Caller ID [Visual Caller ID])/DTMF. To
be mounted on the LCOT4 card.
CID4 Card
LCOT4 Card
288
Installation Manual
6.3.4
BRI2 Card
Function
2-port ISDN Basic Rate Interface card with 1 power failure transfer (PFT) port. EURO-ISDN/
ETSI compliant.
RJ45 (LINE 1)
RJ45 (LINE 2)
LED 1
LED 2
To NT1/Extension
OR
When connecting this optional service card to the trunk, connect through an NT1; do
not connect to the U interface of the trunk directly.
This optional service card has 100
of terminal resistance. For use in point to multipoint connection, the card must be placed at the end of the bus.
This optional service card can be used for either trunk or extension connection, by
setting the A/B switch or using the connector with appropriate pin assignments.
For details about power failure transfer, refer to "6.11.1 Power Failure Connections".
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "6.12.1
Starting the Hybrid IP-PBX".
Notice
If the connected ISDN terminal has no external power source, make sure that the power
is supplied from the BRI2 card by programming the Hybrid IP-PBX accordingly.
However, if there is an external power source to the terminal, make sure that there is no
power supplied to the terminal from the BRI2 card. Failure to do so may cause damage to
the power supply circuit of the BRI2 card or the terminal.
Switch Settings
Switch
Type
A/B
Slide
Installation Manual
289
Pin Assignments
RJ45 Connector for Trunk Use
TX1(+)
RX2(+)
RX1(-)
TX2(-)
Signal Name
Level [V]
Function
TX1
(+)
Transmit data 1
RX2
(+)
Receive data 2
RX1
(-)
Receive data 1
TX2
(-)
Transmit data 2
Reserved
Signal Name
Level [V]
Function
RX2
(+)
Receive data 2
TX1
(+)
Transmit data 1
TX2
(-)
Transmit data 2
RX1
(-)
Receive data 1
Reserved
RX2(+)
TX1(+)
TX2(-)
RX1(-)
LED Indications
Indication
Colour
Description
LINE 1
Green
LINE 2
Green
290
L1
L2
Master
Clock
OFF
OFF
OFF
1s
ON
OFF
OFF
1s
Installation Manual
LED Pattern
L1
L2
Master
Clock
LED Pattern
ON
ON
OFF
1s
ON
OFF
ON
1s
ON
ON
ON
1s
L1: ON (Synchronous)
L2: ON (Link established)/OFF (Link not established)
Master Clock: ON (Master)/OFF (Slave)
Point-to-Point
TE
CAT 5: Under 150 m
TE 1
CAT 5: Under 500 m
TE 1
Point-to-Multipoint
TE 8
CAT 5: Under 50 m
Expansion
Point-to-Multipoint
TE 8
Installation Manual
291
6.3.5
IP-GW4 Card
Function
4-channel VoIP gateway card. VoIP H.323 V.2, ITU-T G.729a, G.723.1 and G.711 compliant.
RJ45
LEDs
To private
IP network
Maximum length of the cable to be connected to this optional service card is 100 m.
For programming instructions and other information about the IP-GW4 card, refer to
the documentation for the IP-GW4 card.
To confirm the trunk connection, refer to "Confirming the Trunk Connection" in "6.12.1
Starting the Hybrid IP-PBX".
Pin Assignments
RJ45 Connector (10BASE-T/100BASE-TX)
Signal Name Input (I)/Output (O) Function
TPO+
TPOTPI+
TPI-
292
Installation Manual
TPO+
Transmit data+
TPO-
Transmit data-
TPI+
Receive data+
TPI-
Receive data-
Reserved
LED Indications
Indication
Colour
Description
ON LINE
Green
ALARM
Red
Alarm indication
ON: Alarm
OFF: Normal
LINK
Green
DATA
Green
Installation Manual
293
6.4
6.4.1
DLC4 Card
Function
4-port digital extension card for DPTs, DSS consoles, a Voice Processing System (VPS), and
PT-interface CSs.
RJ45
To extension
Pin Assignments
RJ45 Connector
D2 D1
D2 D1
294
Installation Manual
16
Signal Name
Function
D1
D2
Reserved
RJ11 Connector
D2
D1
Signal Name
Function
D1
D2
Reserved
Installation Manual
295
6.4.2
SLC4 Card
Function
4-port extension card for SLTs.
RJ45
To extension
Pin Assignments
RJ45 Connector
RT
RT
16
Signal Name
Function
Tip
Ring
Reserved
Signal Name
Function
Tip
Ring
Reserved
RJ11 Connector
RT
296
Installation Manual
6.4.3
DLC8 Card
Function
8-port digital extension card for DPTs, DSS consoles, a VPS, and PT-interface CSs.
RJ45
To extension
Pin Assignments
RJ45 Connector
D2 D1
D2 D1
D2 D1
D2 D1
16
17
24
25
32
Signal Name
Function
D1
D2
Reserved
Installation Manual
297
RJ11 Connector
298
Installation Manual
D2
D1
Signal Name
Function
D1
D2
Reserved
6.4.4
SLC8 Card
Function
8-port extension card for SLTs.
RJ45
To extension
Pin Assignments
RJ45 Connector
RT
RT
RT
16
17
RT
24
25
32
Signal Name
Function
Tip
Ring
Reserved
RJ11 Connector
RT
Signal Name
Function
Tip
Ring
Reserved
Installation Manual
299
6.5
6.5.1
DPH4 Card
Function
4-port doorphone card for 4 doorphones and 4 door openers.
10-pin
8-pin
To door openers
To doorphones
300
Installation Manual
Pin Assignments
RJ45 Connector
DP2
DP1
com1
com2
DP4
DP3
com3
com4
Signal Name
Function
DP2
Doorphone 2 transmit
DP1
Doorphone 1 transmit
com1
Doorphone 1 receive
com2
Doorphone 2 receive
DP4
Doorphone 4 transmit
DP3
Doorphone 3 transmit
com3
Doorphone 3 receive
com4
Doorphone 4 receive
Reserved
Signal Name
Function
DP2
Doorphone 2 transmit
DP1
Doorphone 1 transmit
com1
Doorphone 1 receive
com2
Doorphone 2 receive
DP4
Doorphone 4 transmit
DP3
Doorphone 3 transmit
com3
Doorphone 3 receive
com4
Doorphone 4 receive
Signal Name
Function
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
16
RJ11 Connector
DP2
DP1
com1
com2
DP4
DP3
com3
com4
Installation Manual
301
OP1b
OP1a
OP2b
OP2a
OP3b
OP3a
OP4b
OP4a
302
Installation Manual
10
Signal Name
Function
OP1b
Door opener 1
OP1a
OP2b
Door opener 2
OP2a
OP3b
Door opener 3
OP3a
OP4b
Door opener 4
OP4a
Reserved
6.5.2
DPH2 Card
Function
2-port doorphone card for 2 German type doorphones and 2 door openers.
RJ45
10-pin
8-pin
To doorphones/
door openers
Installation Manual
303
Pin Assignments
RJ45 Connector
OP1b
OP2b
OP1a
OP2a
Path_1b
Path_2b
Path_1a
Path_2a
Call_1b
Call_2b
Call_1a
Call_2a
DC1b
DC2b
DC1a
DC2a
16
Signal Name
Function
OP1b
Door opener 1
OP1a
Path_1b
Doorphone 1 transmit
Path_1a
Doorphone 1 receive
Call_1b
Call_1a
DC1b
Doorphone control 1
DC1a
OP2b
Door opener 2
OP2a
Path_2b
Doorphone 2 transmit
Path_2a
Doorphone 2 receive
Call_2b
Call_2a
DC2b
Doorphone control 2
DC2a
Signal Name
Function
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
304
Installation Manual
10
Signal Name
Function
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Installation Manual
305
6.5.3
ECHO8 Card
Function
8-channel card for echo cancellation during conferences.
306
Installation Manual
6.5.4
MSG2 Card
Function
2-channel message card.
Installation Manual
307
6.5.5
EXT-CID Card
Function
Sends Caller ID signals to extension ports.
308
Installation Manual
6.5.6
MEC Card
Function
Memory expansion card for Broadcasting features and to double the number of DPTs, using
Digital XDP connection. To be installed in the MEC slot.
MEC Card
MEC Slot
CAUTION
Make sure to insert the MEC card between the guide rails until it locks into the MEC slot.
Push the card firmly into place until you hear a clicking sound.
Installation Manual
309
310
Installation Manual
6.5.7
RMT Card
Function
Analogue modem card for remote communication with the Hybrid IP-PBX. V90 support. To be
installed in the RMT slot.
RMT Card
RMT Slot
CAUTION
Make sure to insert the RMT card between the guide rails until it locks into the RMT slot.
Push the card firmly into place until you hear a clicking sound.
Installation Manual
311
312
Installation Manual
6.6
6.6.1
Maximum Distance
Under 222 m
Under 347 m
Under 500 m
Under 347 m
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 500 m
Under 720 m
Under 830 m
Under 720 m
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 140 m
Under 229 m
Under 360 m
Under 229 m
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 698 m
Under 1128 m
Under 1798 m
Under 1128 m
PT-interface
CS
DPT
APT
PT-interface CS
KX-T7600 Series
Other PT and
DSS Console
SLT
DSS
Console
SLT
" indicates that the extension card or Super Hybrid Ports support the terminal.
Installation Manual
313
6.6.2
With APT
To a Super Hybrid Port
Modular
T-Adaptor
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "T", "R", "D1",
and "D2".
APT
SLT
With DPT
Parallel mode or eXtra Device Port (XDP) mode can be selected through system programming.
If the XDP mode is enabled through system programming, parallel connection is not possible.
Refer to "1.10.9 Parallelled Telephone" and "2.1.1 Extension Port Configuration" in the Feature
Guide for further information.
DPT
314
Installation Manual
SLT
SLT
DPT
TO MAIN UNIT
/ PABX
TO TEL
DPT
SLT
TO TEL
To SLT
Installation Manual
315
6.6.3
SLT
Master DPT
Slave DPT
TO MAIN UNIT
/ PABX
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
TO MAIN UNIT
/ PABX
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
Under 50 m
Master DPT
To DLC4/DLC8 card
To a Super Hybrid Port
(for connection of SLT)
316
Installation Manual
Slave DPT
Master DPT
Slave DPT
SLT
TO TEL
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
TO MAIN UNIT
/ PABX
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
Under 50 m
TO TEL
Master DPT
To DLC4/DLC8 card
Slave DPT
To SLT
Installation Manual
317
SLT
Master DPT
Slave DPT
TO MAIN UNIT
/ PABX
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
TO MAIN UNIT
/ PABX
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
Under 50 m
Master DPT
To DLC4/DLC8 card
To a Super Hybrid Port
(for connection of SLT)
318
Installation Manual
Slave DPT
To DLC4/DLC8 card
To a Super Hybrid Port
Master DPT
Slave DPT
SLT
TO DIGITAL
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
TO MAIN UNIT
/ PABX
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
Under 50 m
TO TEL
Master DPT
To DLC4/DLC8 card
Slave DPT
To SLT
Installation Manual
319
To DLC4/DLC8 card
To a Super Hybrid Port
4-conductor wiring cord
Connect pins "D1" and "D2".
Master DPT
Slave DPT
SLT
Back View of DPTs
TO MAIN UNIT
/ PABX
To DLC4/DLC8 card
To a Super Hybrid Port
(for connection of SLT)
To slave DPT
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
320
Installation Manual
Maximum Distance
Under 30 m
Under 50 m
Under 60 m
To SLT
Under 50 m
TO DIGITAL
TO TEL
To PC
USB Cable
USB Port
L
UL
6.6.4
USB Module
Notes
Installation Manual
321
6.7
6.7.1
Overview
The following equipment is required to connect the wireless system:
RF Specification
Item
Description
Frequency Band
Number of Carriers
10*2
Carrier Spacing
1728 kHz
Bit Rate
1152 kbps
Carrier Multiplex
Frame Length
10 ms
Modulation Scheme
GFSK
Roll-off factor=0.5
Differential Coding
Voice CODEC
Transmission Output
Average 10 mW
Peak 250 mW
*1
*2
The number may vary depending on the country/area. In Taiwan, it is 1880 MHz to 1895 MHz.
The number may vary depending on the country/area. In Taiwan, it is 8.
CAUTION
322
Installation Manual
The CS should be kept free of dust, moisture, high temperature (more than 40 C),
low temperature (less than 0 C), vibration, and should not be exposed to direct
sunlight.
Distance
More than 1 m
Each PS
More than 2 m
Too many CSs in a small area can cause problems due to conflicts over which signal
channels each CS can use. Ideally, CSs should be a minimum of 25 m to 40 m apart.
However, the required distance between CSs may vary depending on the
environment of the installation site and conditions in which the wireless system is
used. Conduct the site survey to determine the appropriate distance.
Installation Manual
323
6.7.2
Procedure Overview
When connecting the wireless system, use extreme care to conduct a site survey. Site surveys
can be conducted using the KX-TCA255 or KX-TD7590 PS. Inadvertent site survey can result
in poor service area, frequent noise, and disconnection of calls.
Channel No.
Display example:
RADIO STRENGTH
<<< MEASURING >>>
0 to 9
RADIO STRENGTH
CH0 SLOT:06 SYNC
L:12 0000/0100
CS-ID:9005301234
Channel No.
Display example:
RADIO STRENGTH
<<< MEASURING >>>
0 to 9
b. By walking away from the CS with the PS, check the radio signal strength. The radio
signal strength weakens as you walk away from the CS.
c. Map the CS coverage area at radio signal strength levels "3" and "8".
d. Make sure that adjacent CS coverage areas overlap where the radio signal strength
level is "8" by at least 5 m.
324
Installation Manual
e. Make sure that the radio signal strength level is greater than "3" at any location within
the service area demanded by the user.
a. Return all DIP switches of each CS to the OFF position, and stop supplying power.
b. Turn off the PS.
5. Connect the CS and PS to the Hybrid IP-PBX and test the operation
Refer to "6.7.7 Connecting a Cell Station to the Hybrid IP-PBX".
Installation Manual
325
6.7.3
Site Planning
Choosing the best site for the CS requires careful planning and testing of essential areas. The
best location may not always be convenient for installation. Read the following information
before installing the unit.
CS
1. Reflection
Column
2. Diffraction
3. Penetration
326
The CS coverage area is affected more by the building materials and their thickness than
the number of obstacles.
Radio waves tend to be reflected or diffracted by conductive objects and rarely penetrate
them.
Radio waves tend to penetrate insulated objects and are rarely reflected by them.
Radio waves penetrate thin objects more than thick objects.
The table below shows the transmission tendency of radio waves when they reach objects
made from various materials.
Installation Manual
Object
Material
Transmission Tendency
Wall
Concrete
Ferroconcrete
Glass
Window
Glass with wire nets Radio waves can penetrate them, but tend to be
reflected.
Glass covered with
heat-resistant film
Floor
Ferroconcrete
Partition
Steel
Plywood, Glass
Ferroconcrete
Metal
Steel
Wood
Column
Cabinet
Installation Manual
327
CS Coverage Area
The example below shows the size of the coverage area of 1 CS if it is installed where there is
no obstacle.
Note
Radio signal strength levels are measured during the site survey (refer to "6.7.5 Site
Survey Using the KX-TCA255/KX-TD7590").
Coverage Area
Radio signal strength level is
greater than "3".
(About 50 m to 60 m)
B
B
Gray Zone:
Conversation will be
intermittent
Out of Service:
Cannot make/receive calls
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
a. Draw the coverage area around a CS. Extend the coverage area to 30 m to 60 m in
one direction, depending on the materials of the building structures and obstacles in
the installation site. Note that a CS cannot be installed outside a building.
328
Installation Manual
b. If 1 CS cannot cover the entire service area, install additional CSs as required.
Overlap the coverage areas of adjacent CSs.
Where CS coverage areas overlap, the PS will start call handover to the next CS if the
signal from one CS becomes weak. However, if a PS moves away from a CS and
there are no CSs available for handover, the PS may go out of range and the call could
be lost.
The coverage area of each CS will not extend as much it does where there is no
obstacle, because the radio signals will be weakened by separating walls. Therefore,
you will need 5 CSs to cover the entire room.
150 m
70 m
CS no. 1
CS no. 2
CS no. 5
CS no. 3
CS no. 4
Installation Manual
329
6.7.4
ABC
A:
C:
ABC
E:
GHI
B:
D:
DEF
F:
JKL
CS No.
CS ID No.
0 to 7
0 to 9 and A to F
Note
To clear the CS ID number assigned to the PS, follow the procedure below:
To clear one by one
CS No.
0 to 7
1
DEF
3
To the Desired CS No.
OR
330
Installation Manual
ABC
A:
F1
C:
F3
E:
B:
F2
D:
INT'
F:
CS No.
CS ID No.
0 to 7
0 to 9 and A to F
OK
Note
To clear the CS ID number assigned to the PS, follow the procedure below:
To clear one by one
CS No.
0 to 7
1
DEF
3
To the Desired CS No.
OR
Installation Manual
331
DIP Switch
OFF
ON
1
2
Channel Number Switch
3
4
5
6
Radio Signal
Test Switch
Channel 0
Notes
332
Installation Manual
To see the radio signal strength of more than 1 CS, a channel number must be set for
each CS.
If more than 1 CS is in Radio Signal Test mode, each CS must have a unique channel
number.
3. After setting the DIP switch, connect an AC adaptor or battery box to the CS using a power
supply adaptor.
Note for users in the United Kingdom
240 V AC must not be used on a building site. Instead of an AC adaptor, connect a
battery box to the CS.
Telephone Cord
Modular
4. Install the CS temporarily for the site survey. Install the CS at least 2 m above the floor,
keeping the antennas in the upright position.
Installation Manual
333
6.7.5
Channel No.
Previous or Next
0 to 9
Display example:
RADIO STRENGTH
CH0*1 SLOT:06*2 SYNC*3
L:12*4 0000/0100*5
CS-ID:9005301234
Log No.
0 to 9
Channel No.
Previous or Next
0 to 9
Display example:
RADIO STRENGTH
<<< MEASURING >>>
Log No.
0 to 9
Notes
*1: Channel number
*2: Slot number
*3: When a slot is synchronised, "SYNC" is displayed.
*4: Radio signal strength level
*5: Frame error (0000 to 9999)/Frame counter (0000 to 9999). Frame error indicates the
number of errors out of 10 000 radio signal receptions. An increased number of frame
errors indicates greater radio signal interference and more frequent noise during
conversation. The ideal number of frame error is "0000".
CAUTION
Storing the scan data will clear all directory data.
334
Installation Manual
2. Measure the radio signal strength by moving to and away from the CS.
a. Move to the CS until the point the radio signal strength level becomes "12".
b. Move away from the CS and identify the CS coverage area within which the radio
signal strength level is greater than "8". Draw the area on the map.
c. Move away from the CS and identify the CS coverage area within which the radio
signal strength level is greater than "3". Draw the area on the map.
PS
Channel no. 0
CH0
L:12
PS
CH0
L:08
PS
CH0
L:03
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
3. Repeat the steps 1 and 2 for other CSs, and relocate the CSs when necessary.
a. Overlap adjacent CS coverage areas where the radio signal strength level is "8" by 5
m to 10 m.
Channel no. 0
5 m to 10 m
Channel no. 1
Installation Manual
335
b. Overlap the CS coverage areas of at least 2 CSs at any location in the installation site.
Channel no. 0
Channel no. 1
Channel no. 2
Channel no. 3
c. Make sure that the radio signal strength level is greater than "3" at any location in the
service area demanded by the user.
Notes
336
Installation Manual
If a channel is set, the results of measurement for the 24 slots on the channel are
saved each time. If the same channel is set, the new results override the previous
ones. Therefore, a measurement of 10 channels 24 slots in total can be made.
If correct results cannot be obtained (e.g., there are many error counters), change the
location of the CS and repeat the site survey to select the best location.
Log No.
0 to 9
To go to other slots
To go to specific channel
Channel No.
Previous or Next
0 to 9
A a
Log No.
0 to 9
To go to other slots
To go to specific channel
Channel No.
Previous or Next
0 to 9
GHI
GHI
Installation Manual
337
6.7.6
OFF
1
2
3
4
5
6
338
Installation Manual
ON
6.7.7
Maximum Distance
Under 222 m
Under 347 m
Under 500 m
Under 347 m
D2
D1
Pin No.
1
2
3
4
5
6
7
8
CS (RJ11)
Pin No.
1
2
3
4
Signal Name
D1
D2
CS (RJ11)
Pin No.
1
2
3
4
Signal Name
D1
D2
Installation Manual
339
Connecting the CS
1. Connect the cable from a Super Hybrid Port or the DLC4/DLC8 card to the CS.
Modular
To a Super Hybrid Port,
or DLC4/DLC8 card
2. Pass the cable through the groove of the CS (in any direction depending on your
preference).
TO MAIN UNIT
/ PABX
340
Installation Manual
Registering the PS
The PS must be registered to the Hybrid IP-PBX before it can be used. Programming of both
the PS and Hybrid IP-PBX is required. A PT with multiline display (e.g., KX-T7636 6-line
display) is required for the Hybrid IP-PBX system programming.
Note
For details about system programming using a PT, refer to "2.3.2 PT Programming" and
"3.3 PT Programming" in the Feature Guide.
#
PROGRAM/
PAUSE
Programming No.
= 1234
3 digits
Note
means default value.
PS Registration
One PS can be registered to a maximum of 4 different Hybrid IP-PBXs.
[690]
ENTER
PS No.
Extn. No.
001 to 028
1 to 4 digits
ENTER
To the PS
operation
below
END
Press POWER
for 2 seconds.
Select
"Setting Handset".
Select
"Registration".
"Please wait".
Select
"Register H/set".
Select
"Base 14".
C.Tone
Installation Manual
341
Press POWER
for 5 seconds.
To register for the first time
SELECT
/
Select
"INITIAL SETTING".
OR
To re-register
If required
SELECT
/
Select
"PS-PROGRAM".
Select
"REGISTRATION".
/OK
SELECT
4 digits
SELECT
/
Select
"DECT-SYS1-4"
PIN for
PS Registration
/OK
C.Tone
4 digits
/
Choose
"ENABLE/DISABLE".
4 digits
DISABLE
/OK
ENABLE
/OK
4 digits
/
Press POWER
for 2 seconds.
/
Select
"Register H/set".
342
Installation Manual
Select
"Setting Handset".
/
Select
"Base 14".
/
Select
"Registration".
PIN for
PS Registration
4 digits
C.Tone
By default, the PIN for PS registration is "1234" for both the Hybrid IP-PBX and PS.
Therefore, the PS can be registered to the Hybrid IP-PBX without setting the PIN.
The PIN for PS registration will only be used when registering the PS to the Hybrid
IP-PBX. Therefore, even when there is more than 1 Hybrid IP-PBX with the same PIN
near the PS, the PS will not be linked to a different Hybrid IP-PBX during normal
operation after registration.
Setting the PIN for Hybrid IP-PBX
[692]
ENTER
END
ENTER
Press POWER
for 2 seconds.
Select
"Setting Handset".
Select
"Select Language".
Select
"Display Option".
Press POWER
for 5 seconds.
SELECT
Select
"DISPLAY SETTING".
SELECT
SELECT
/
Select
"LANGUAGE".
SELECT
/
Select the desired
language.
/
Press POWER
for 2 seconds.
Select
"Setting Handset".
Select "Select
Language".
Select
"Display Option".
Installation Manual
343
PS Termination
Confirm the following before cancelling the PS registration:
PS is turned on.
[691]
PS No.
001 to 028
ENTER
ENTER
YES
Press "CLEAR".
To the PS
operation
below
END
Press "YES".
Press POWER
for 2 seconds.
Select
"Setting Handset".
Select
"Registration".
Select
"Cancel Base".
Handset PIN
C.Tone
4 digits
Select
"Base 14".
Select
"YES".
SELECT
Press POWER
for 5 seconds.
If required
/
Select the
desired item.
Select "CANCEL
DECT-SYS".
4 digits
SELECT
SELECT
/OK
SELECT
C.Tone
Select "YES".
/
Press POWER
for 2 seconds.
Handset PIN
Select
"Cancel Base".
4 digits
Select the
desired item.
Installation Manual
Select
"Registration".
Select "YES".
344
Select
"Setting Handset".
C.Tone
Installation Manual
345
6.7.8
Wall Mounting
1. Place the reference for wall mounting (on the following page) on the wall to mark the 2
screw positions.
Make sure that the screw heads are at the same distance from the wall.
Install the screws perpendicular to the wall.
346
Installation Manual
71 mm
Note
When you print out this page, the distance on the paper output may deviate slightly from
the measurement indicated above.
Installation Manual
347
6.8
6.8.1
Overview
The following equipment is required to connect the wireless system:
CAUTION
The CS should be kept free of dust, moisture, high temperature (more than 40 C),
low temperature (less than 0 C), vibration, and should not be exposed to direct
sunlight.
The CS should not be placed outdoors (use indoors).
The CS should not be placed near high voltage equipment.
The CS should not be placed on a metal object.
Systems using 2.4 GHz ISM (Industrial, Scientific and Medical) band may interfere
with the KX-TDA wireless system. Examples of such systems are cordless
telephones, wireless LAN, Home RF, microwave ovens and other ISM devices. These
systems may cause minor noise.
Keeping some distance between the equipment listed below may prevent
interference. (The distance may vary depending on the environment.)
Equipment
Distance
More than 1 m
Each PS
More than 2 m
CS and CS
More than 15 m
Please take into consideration the distance between the CSs when site planning.
Please consult a certified dealer for details.
However, the required distance between CSs may vary depending on the
environment of the installation site and conditions in which the wireless system is
used. Conduct the site survey to determine the appropriate distance.
348
Installation Manual
6.8.2
Procedure Overview
When connecting the wireless system, use extreme care to conduct a site survey. Inadvertent
site survey can result in poor service area, frequent noise, and disconnection of calls.
a. Assign a CS number to each CS by setting the DIP switches on the back of the CS.
b. Supply electricity to each CS using an AC adaptor or a battery box.
c. Install each CS temporarily as planned.
Notes
CS No.
CS NO.1 LEVEL:12
<< SEARCHING >>
SAVE:0123456789
1 to 9
CS No.
CS NO.1 LEVEL:12
<< SEARCHING >>
1 to 9
SAVE:0123456789
b. By walking away from the CS with the PS, check the radio signal strength. The radio
signal strength weakens as you walk away from the CS.
c. Map the CS coverage area at radio signal strength levels "3" and "8".
d. Make sure that adjacent CS coverage areas overlap where the radio signal strength
level is "8" by at least 5 m.
e. Make sure that the radio signal strength level is greater than "3" at any location within
the service area demanded by the user.
Installation Manual
349
a. Return all DIP switches of each CS to the OFF position, and stop supplying power.
b. Turn off the PS.
5. Connect the CS and PS to the Hybrid IP-PBX and test the operation
Refer to "6.8.7 Connecting a Cell Station to the Hybrid IP-PBX".
350
Installation Manual
6.8.3
Site Planning
Choosing the best site for the CS requires careful planning and testing of essential areas. The
best location may not always be convenient for installation. Read the following information
before installing the unit.
CS
1. Reflection
Column
2. Diffraction
3. Penetration
The CS coverage area is affected more by the building materials and their thickness than
the number of obstacles.
Radio waves tend to be reflected or diffracted by conductive objects and rarely penetrate
them.
Radio waves tend to penetrate insulated objects and are rarely reflected by them.
Radio waves penetrate thin objects more than thick objects.
The table below shows the transmission tendency of radio waves when they reach objects
made from various materials.
Installation Manual
351
Object
Material
Transmission Tendency
Wall
Concrete
Ferroconcrete
Glass
Window
Glass with wire nets Radio waves can penetrate them, but tend to be
reflected.
Glass covered with
heat-resistant film
Floor
Ferroconcrete
Partition
Steel
Plywood, Glass
Ferroconcrete
Metal
Steel
Wood
Column
Cabinet
352
Installation Manual
CS Coverage Area
The example below shows the size of the coverage area of 1 CS if it is installed where there is
no obstacle.
Note
Radio signal strength levels are measured during the site survey (refer to "6.8.5 Site
Survey").
Coverage Area
Radio signal strength level is
greater than "3".
(About 50 m to 60 m)
B
B
Gray Zone:
Conversation will be
intermittent
Out of Service:
Cannot make/receive calls
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
a. Draw the coverage area around a CS. Extend the coverage area to 30 m to 60 m in
one direction, depending on the materials of the building structures and obstacles in
the installation site. Note that a CS cannot be installed outside a building.
Installation Manual
353
b. If one CS cannot cover the entire service area, install additional CSs as required.
Overlap the coverage areas of adjacent CSs.
Where CS coverage areas overlap, the PS will start call handover to the next CS if the
signal from one CS becomes weak. However, if a PS moves away from a CS and
there are no CSs available for handover, the PS may go out of range and the call could
be lost.
If the signal from the CS fades, due to the structure of the building, there may be some
handover delay. The user will hear a range warning before handover in this case. This
also applies in the case of interference from 2.4 GHz apparatus.
The coverage area of each CS will not extend as much it does where there is no
obstacle, because the radio signals will be weakened by separating walls. Therefore,
you will need 5 CSs to cover the entire room.
150 m
70 m
CS no. 1
CS no. 2
CS no. 5
CS no. 3
354
Installation Manual
CS no. 4
6.8.4
DIP Switch
OFF
ON
1
2
CS Number Switch
3
4
5
6
CS no. 1
CS no. 2
CS no. 3
CS no. 4
Radio Signal
Test Switch
CS no. 5
CS no. 6
CS no. 7
CS no. 8
CS no. 9
Notes
To see the radio signal strength of more than 1 CS, a CS number must be set for each
CS.
If more than 1 CS is in Radio Signal Test mode, each CS must have a unique CS
number.
Installation Manual
355
3. After setting the DIP switch, connect an AC adaptor or battery box to the CS using a power
supply adaptor.
Telephone Cord
Modular
4. Install the CS temporarily for the site survey. Install the CS at least 2 m above the floor,
keeping the antennas in the upright position.
356
Installation Manual
6.8.5
Site Survey
The PS has a Radio Signal Test mode that monitors the state of the radio link to the CS. After
installing the CSs temporarily, set the PS to the Radio Signal Test mode and measure each CS
coverage area. Then, record the results on the map of the installation site.
CS No.
CS NO.1 LEVEL:12*1
<< SEARCHING >>
1 to 9
SAVE:0123456789*2
CS No.
1 to 9
CS NO.1 LEVEL:12*1
<< SEARCHING >>
SAVE:0123456789*2
Notes
*1: CS number and radio signal strength level.
*2: Scan data (test result) number. Empty memory space will be indicated by a number;
stored memory space will be indicated by a "-".
Installation Manual
357
2. Measure the radio signal strength by moving to and away from the CS.
a. Move to the CS until the point the radio signal strength level becomes "12".
b. Move away from the CS and identify the CS coverage area within which the radio
signal strength level is greater than "8". Draw the area on the map.
c. Move away from the CS and identify the CS coverage area within which the radio
signal strength level is greater than "3". Draw the area on the map.
PS
CS NO.1 LEVEL:12
CS no. 1
PS
CS NO.1 LEVEL:8
PS
CS NO.1 LEVEL:3
Out of range
Receives noise easily or disconnects
May receive noise
Good
Better
3. Repeat the steps 1 and 2 for other CSs, and relocate the CSs when necessary.
a. Overlap adjacent CS coverage areas where the radio signal strength level is "8" by 5
m to 10 m.
CS no. 1
358
Installation Manual
5 m to 10 m
CS no. 2
b. Overlap the CS coverage areas of at least 2 CSs at any location in the installation site.
CS no. 1
CS no. 2
CS no. 3
CS no. 4
c. Make sure that the radio signal strength level is greater than "3" at any location in the
service area demanded by the user.
Display example:
When there is scan data
NO.1
CS No.2 LEVEL: 9
When there is no scan data
NO.0
NOT SAVED
Display example:
When there is scan data
NO.1
CS No.2 LEVEL: 9
When there is no scan data
NO.0
NOT SAVED
Installation Manual
359
360
Installation Manual
6.8.6
OFF
ON
1
2
3
4
5
6
Installation Manual
361
6.8.7
Maximum Distance
Under 222 m
Under 347 m
Under 500 m
Under 347 m
D2
D1
Pin No.
1
2
3
4
5
6
7
8
CS (RJ11)
Pin No.
1
2
3
4
Signal Name
D1
D2
CS (RJ11)
Pin No.
1
2
3
4
Signal Name
D1
D2
362
Installation Manual
Connecting the CS
1. Connect the cable from a Super Hybrid Port or the DLC4/DLC8 card to the CS.
Modular
To a Super Hybrid Port,
or DLC4/DLC8 card
2. Pass the cable through the groove of the CS (in any direction depending on your
preference).
TO MAIN UNIT
/ PABX
Installation Manual
363
Registering the PS
The PS must be registered to the Hybrid IP-PBX before it can be used. Programming of both
the PS and Hybrid IP-PBX is required. A PT with multiline display (e.g., KX-T7636 6-line
display) is required for the Hybrid IP-PBX system programming.
Note
For details about system programming using a PT, refer to "2.3.2 PT Programming" and
"3.3 PT Programming" in the Feature Guide.
#
PROGRAM/
PAUSE
Programming No.
= 1234
3 digits
Press POWER
for 2 seconds.
Select
"PS PROGRAM".
Select
"SYSTEM SET".
If required
4 digits
S1
SEL
Select
"PS PROGRAM".
If required
SEL
Select
"SYSTEM SETTING".
S1
ENTR
Note
means default value throughout this section.
364
Installation Manual
S1
PS Registration
[690]
ENTER
PS No.
Extn. No.
001 to 028
1 to 4 digits
ENTER
To the PS
operation
below
END
[ F3 ]
Press S2 repeatedly
to select the desired
language.
Press S3
for 2
seconds.
C.Tone
Press
POWER for
2 seconds.
F3
Press S2 repeatedly
to select the desired
language.
Press S3
for 2
seconds.
C.Tone
Press
POWER for
2 seconds.
C.Tone
Choose
"SYSTEM 14".
Select
"REGISTRATION".
S1
SEL
Choose
"SYSTEM 14".
C.Tone
S1
Installation Manual
365
Choose
"Enable/Disable".
Select
"SYSTEM LOCK".
4 digits
4 digits
ENABLE
DISABLE
C.Tone
Select
"SYSTEM LOCK".
SEL
SEL
CHNG
S1
S1
Choose
"Enable/Disable".
ENTR
4 digits
S1
4 digits
ENABLE
S1
DISABLE
ENTR
C.Tone
S1
366
Installation Manual
By default, the PIN for PS registration is "1234" for both the Hybrid IP-PBX and PS.
Therefore, the PS can be registered to the Hybrid IP-PBX without setting the PIN.
The PIN for PS registration will only be used when registering the PS to the Hybrid
IP-PBX. Therefore, even when there is more than 1 Hybrid IP-PBX with the same PIN
near the PS, the PS will not be linked to a different Hybrid IP-PBX during normal
operation after registration.
Setting the PIN for Hybrid IP-PBX
[692]
1 to 4 digits
1234
ENTER
END
C.Tone
1 to 4 digits
1234
S1
ENTR
C.Tone
S1
Installation Manual
367
PS Termination
Confirm the following before cancelling the PS registration:
PS is turned on.
[691]
PS No.
001 to 028
ENTER
ENTER
YES
To the PS
operation
below
END
Press "YES".
Select "YES".
Select the
desired item.
Select "DELETE
SYSTEM".
C.Tone
S1
SEL
Select the
desired item.
S1
Select "YES".
SEL
C.Tone
S1
368
Installation Manual
6.8.8
Wall Mounting
1. Place the reference for wall mounting (on the following page) on the wall to mark the 2
screw positions.
Make sure that the screw heads are at the same distance from the wall.
Install the screws perpendicular to the wall.
Installation Manual
369
71 mm
Note
When you print out this page, the distance on the paper output may deviate slightly from
the measurement indicated above.
370
Installation Manual
6.9
6.9.1
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 70 m
Under 113 m
Under 180 m
Under 113 m
Doorphone
Door Opener
Pan
ason
ic
Screw
Installation Manual
371
2. Pass the wires through the hole in the base cover, and attach the base cover to a wall
using 2 screws.
Screw
To terminal box
Note
Two kinds of screws are included with KX-T30865. Please choose the appropriate kind for
your wall type.
: when a doorphone plate has been fixed to the wall
: when you wish to install the doorphone directly to the wall
To terminal box
372
Installation Manual
Terminal Box
(included with the card)
To doorphones
Pin Assignments for Terminal Box
com2
DP2
Reserved
Reserved
DP1
com1
Reserved
Reserved
com4
DP4
Reserved
Reserved
DP3
com3
Reserved
Reserved
Installation Manual
373
3. Cut and remove the appropriate parts from the cover depending on your preference.
4. Make sure to run the connected wires through the opening. Then, close the cover.
374
Installation Manual
5. Connect the terminal box to the DPH4 card in the Hybrid IP-PBX using the telephone line
cords included with the card.
To DPH4 card
To doorphones
Installation Manual
375
2. Connect the wires of doorphones 1 and 3 to the red and green screws on the terminal box.
3. Connect the wires of doorphones 2 and 4 to the yellow and black screws on the terminal
box.
To DPH4 card
Black
Green
Panasonic
Panasonic
Doorphone 3
Doorphone 4
Yellow
Red
Panasonic
Doorphone 1
376
Installation Manual
Black
Green
Panasonic
Doorphone 2
2. Connect the wires of door openers and doorphones to the terminal box.
For details about pin assignments for the DPH2 card, refer to "6.5.2 DPH2 Card".
Terminal Box
(included with the card)
To doorphones/door openers
Pin Assignments for Terminal Box
Call_1a
Path_1b
OP1a
OP1b
Path_1a
Call_1b
DC1a
DC1b
Call_2a
Path_2b
OP2a
OP2b
Path_2a
Call_2b
DC2a
DC2b
Installation Manual
377
3. Cut and remove the appropriate parts from the cover depending on your preference.
4. Make sure to run the connected wires through it. Then, close the cover.
378
Installation Manual
5. Connect the terminal box to the DPH2 card in the Hybrid IP-PBX using the telephone line
cords included with the card.
To DPH2 card
To doorphones/door openers
Installation Manual
379
1. While pressing down on the hole at the top of the terminal block using a screwdriver, insert
the wire into the side hole as shown below. Repeat this procedure for other door openers.
Refer to "6.5.1 DPH4 Card" for pin assignments.
Door Opener
2. Attach the terminal block to the connector of the DPH4 card in the Hybrid IP-PBX.
To door openers
380
Installation Manual
Maximum Distance
Under 10 m
Under 10 m
Under 10 m
Under 10 m
BGM/
Music on Hold
Cable
0.4 mm:
0.5 mm:
0.6 mm:
CAT 5:
Maximum Distance
Under 10 m
Under 10 m
Under 10 m
Under 10 m
Maximum Distance
Under 2 m
Maximum Distance
Under 5 m
Pager:
Amplifier/Speaker
PC
Printer
PC
BGM/MOH
The Hybrid IP-PBX provides Background Music and Music on Hold. Only 1 external music
source (e.g., a user-supplied radio) can be connected to the Hybrid IP-PBX.
CAUTION
Wiring should be done carefully to prevent undue force being exerted on the plug.
Otherwise, music may intermittent.
An External Music Jack is an SELV port and should only be connected to an approved
SELV device, or in Australia, via the Line Isolation Unit with the Telecommunications
Compliance Label.
Note
When the Hybrid IP-PBX and external music sources are not connected to the same
earth, hum noise may be induced into Background Music and Music on Hold.
Installation Manual
381
Pager
Only 1 paging device (user-supplied) can be connected to the Hybrid IP-PBX.
CAUTION
An External Paging Jack is an SELV port and should only be connected to an approved
SELV device, or in Australia, via the Line Isolation Unit with the Telecommunications
Compliance Label.
Pin Assignments
Circuit Type
No.
Signal Name
Function
EIA
CCITT
RD (RXD)
Receive Data
BB
104
3
4
SD (TXD)
ER (DTR)
Transmit Data
Data Terminal Ready
BA
CD
103
108.2
5
6
SG
DR (DSR)
Signal Ground
Data Set Ready
AB
CC
102
107
7
8
RS (RTS)
CS (CTS)
Request To Send
Clear To Send
CA
CB
105
106
Connection Charts
For connecting a printer/PC with a 9-pin RS-232C connector
Hybrid IP-PBX
382
Printer/PC
Circuit Type
(EIA)
Signal
Name
Pin No.
Pin No.
Signal
Name
Circuit Type
(EIA)
BB
RD (RXD)
RD (RXD)
BB
BA
SD (TXD)
SD (TXD)
BA
CD
ER (DTR)
ER (DTR)
CD
AB
SG
SG
AB
CC
DR (DSR)
DR (DSR)
CC
CA
RS (RTS)
RS (RTS)
CA
CB
CS (CTS)
CS (CTS)
CB
Installation Manual
Hybrid IP-PBX
Printer/PC
Circuit Type
(EIA)
Signal
Name
Pin No.
Pin No.
Signal
Name
Circuit Type
(EIA)
BB
RD (RXD)
FG
AA
BA
SD (TXD)
RD (RXD)
BB
CD
ER (DTR)
SD (TXD)
BA
AB
SG
20
ER (DTR)
CD
CC
DR (DSR)
SG
AB
CA
RS (RTS)
CS (CTS)
CB
CB
CS (CTS)
DR (DSR)
CC
RS (RTS)
CF
RS-232C Signals
Installation Manual
383
Pin Assignments
No.
384
Installation Manual
Signal Name
VBUS
USB D-
USB D+
GND
RJ45
(LINE 1)
To NT1
RJ45
(LINE 2)
To ISDN extension
ON
ON
123 4 567 8
OFF
1 234567 8
OFF
Installation Manual
385
Switch Settings
Switch
Type
PFT Setting
DIP
TX1(+)
RX2(+)
RX1(-)
TX2(-)
Signal Name
Level [V]
Function
TX1
(+)
Transmit data 1
RX2
(+)
Receive data 2
RX1
(-)
Receive data 1
TX2
(-)
Transmit data 2
Reserved
Signal Name
Level [V]
Function
RX2
(+)
Receive data 2
TX1
(+)
Transmit data 1
TX2
(-)
Transmit data 2
RX1
(-)
Receive data 1
Reserved
RX2(+)
TX1(+)
TX2(-)
RX1(-)
386
Installation Manual
SD Memory Card must be inserted in the SD Memory Card slot of the main board
before start up.
Before touching the System Initialise Switch and the Reset Button, discharge static
by touching ground or wearing an earthing strap.
Once you have started the Hybrid IP-PBX and if you unplug the Hybrid IP-PBX, do
not perform the following procedures to start the Hybrid IP-PBX again. Otherwise,
your programmed data is cleared. To restart the Hybrid IP-PBX, refer to "8.1.4 Using
the Reset Button".
The Hybrid IP-PBX will continue to be powered even if the power switch is turned
"OFF".
The power supply cord is used as the main disconnect device, ensure that the socketoutlet is located/installed near the equipment and is easily accessible.
RUN Indicator
ALARM Indicator
Reset Button
System Initialise Switch
Installation Manual
387
DC IN 1
DC Connector
1
2
AC Adaptor
Notes
DC Connector
DC IN 2
1
Additional
AC Adaptor
AC Adaptor
388
Installation Manual
3. Plug the AC cord into the AC adaptor, and then plug the other end into an AC outlet.
AC Adaptor
AC Cord
To AC outlet
Power Switch
Notes
For safety reasons, follow the procedures as indicated when turning on the Hybrid IPPBX.
For safety reasons, do not stretch, bend, or pinch the AC cord and the DC cable of
the AC adaptor.
5. Press the Reset Button with a pointed tool. (The RUN indicator will flash.)
6. While the RUN indicator is flashing (within about 10 s), return the System Initialise Switch
to the "NORMAL" position. Depending on the configuration, initialisation takes about 1 min
to 3 min. If successfully executed, the RUN indicator will stop flashing and be kept lit.
All data will be cleared, and the Hybrid IP-PBX as well as all optional service cards (except for
the IP-GW4 card) will be initialised to the default values. The DPTs should show the time as
01:00.
The data of the IP-GW4 card will not be initialised.
Note
Use the same types of AC adaptor and AC cord that are supplied with the Hybrid IP-PBX
only.
Installation Manual
389
LED Indications
Indication
Colour
Description
RUN
Green
ALARM
Red
Alarm indication
OFF: Normal
390
Installation Manual
Section 7
Guide for the KX-TDA30 Maintenance
Console KX-TDA30
Installation Manual
391
7.1
Overview KX-TDA30
7.1.1
Overview
KX-TDA30 Maintenance Console is designed to serve as an overall system programming
reference for the Hybrid IP-PBX. To programme and administer the Hybrid IP-PBX by PC, you
need to install the KX-TDA30 Maintenance Console onto the PC.
This manual describes overview and installation of the KX-TDA30 Maintenance Console only.
KX-TDA30 Maintenance Console*1
Menu Bar
Programme Menu
*1
The contents and design of the software are subject to change without notice.
392
Installation Manual
7.2
Connection KX-TDA30
7.2.1
Connection
RS-232C Port
To COM Port
PC
To USB Port
PC
USB Port
Note
For pin assignments and maximum cabling distance, refer to "6.10.1 Connection of
Peripherals".
Installation Manual
393
To RS-232C port
(25-pin)
Modem
External Modem
Signal Name
Pin No.
Pin No.
Signal Name
RD (RXD)
SD (TXD)
SD (TXD)
RD (RXD)
ER (DTR)
DR (DSR)
DR (DSR)
20
ER (DTR)
After connecting the Hybrid IP-PBX and the external modem, set the power switch of the
external modem to "ON", then the external modem will be initialised with the default values.
The following AT command settings may be required for the modem:
The Data Terminal Equipment (DTE)/Modem flow control should be turned off.
394
Installation Manual
Use an RS-232C straight cable for connection between the Hybrid IP-PBX and
external modem.
An AT command (for initialisation, enabling automatic answer, etc.) can only be
programmed by KX-TDA30 Maintenance Console. "AT&F0E0V1X1S10=30S12=50"
is stored as the default value.
For more information about the AT command, refer to the external modems
instructions.
7.3
7.3.1
System Requirements
Operating System
Password Security
A password is required to perform programming for security purposes. Do not disclose the
password. This will avoid unauthorised access and possible dial through fraud.
Warning to the Administrator regarding the system password
1. Please inform the customer of the importance of the password and the possible
dangers.
2. Please maintain the secrecy of the password. This will avoid unauthorised access and
possible dial through fraud.
5. If the system password is forgotten, you can examine the backup of the system
Installation Manual
395
2. a.
b.
c.
d.
e.
Notes
Date and Time of the Hybrid IP-PBX. The date and time set on the PC will be used.
Operator extension numbers. Operator extensions for all time modes (day/lunch/
break/night) can be assigned.
396
Installation Manual
Flexible Numbering type to pattern 1 or pattern 2. If pattern 1 (with ) is selected, " "
must prefix all feature numbers (except access numbers) when an extension user
wants to use a feature.
Operator call and Idle Line Access/ARS numbers (0 or 9). The feature numbers for
operator call and Idle Line Access/ARS can be selected.
Remote Maintenance Dial Number. Enter the complete telephone number of the PBX
(including the country code). When necessary, this number will be used to access the
PBX from a remote location for maintenance purposes.
Installation Manual
397
Notice
2. When the PBX is initialised, not all data is taken from the SD Memory Card. The data
for present status of extension FWD/DND buttons is taken from battery backup
memory in the PBX.
3. The PC will not perform any shutdown operation, or enter the power-saving system
standby mode while the KX-TDA30 Maintenance Console is connected to the Hybrid
IP-PBX. To perform either of the operations above, first close the connection to the
Hybrid IP-PBX.
CAUTION
Do not remove the SD Memory Card during access to it. Doing so will damage the system
data, and in the worst case, damage the SD Memory Card.
398
Installation Manual
7.3.2
Menu Bar
File
Connect
Tool
Utility
Diagnosis
File Transfer PC to PBX (SD Card)
File Transfer PBX (SD Card) to PC
SD Card File View and Load
SD Card File Delete
Message File Transfer PC to PBX
Message File Transfer PBX to PC
Error Log
ISDN/Qsig Protocol Trace
CS Information
PS Information
System Reset
Window
Help
Installation Manual
399
7.3.3
a. Double-click "Configuration".
b. Double-click "Slot".
a. Double-click "Configuration".
b. Double-click "Portable Station".
400
Installation Manual
7.3.4
3. a.
Installation Manual
401
402
Error Log
CS Information
PS Information
System Reset
Reset by the Command
Installation Manual
Section 8
Troubleshooting KX-TDA30
Installation Manual
403
8.1
Troubleshooting KX-TDA30
8.1.1
Installation
PROBLEM
PROBABLE CAUSE
Bad extension card.
SOLUTION
Exchange the card for a known working one.
Bad connection between the Take the telephone and plug it into the same
Hybrid IP-PBX and
extension port using a short telephone cord.
telephone.
If the telephone works, then the connection
between the Hybrid IP-PBX and the
telephone must be repaired.
A telephone with an A-A1
relay is connected.
Bad telephone.
Improper operation.
Alternate CallingRing/Voice
and Live Call Screening
(LCS) do not function as set
when using a Wireless Phone
(KX-T7880/KX-T7885/KXTD7894/KX-TD7895).
A major system error occurs See the error log using the KX-TDA30
in the Hybrid IP-PBX.
Maintenance Console (refer to "8.1.5
Troubleshooting by Error Log").
404
Installation Manual
8.1.2
Connection
Connection between the Hybrid IP-PBX and a PT:
CAUSE
No
SOLUTION
D1
T
R
D2
Hybrid IP-PBX
Extension
CAUSE
SOLUTION
T
R
Hybrid IP-PBX
Yes
Extension
CAUSE
SOLUTION
T
R
Extension
Installation Manual
405
CAUSE
Trunk is connected to the T2/T1.
T2
R1
T1
R2
No
Trunk
Hybrid IP-PBX
406
Installation Manual
Hybrid IP-PBX
SOLUTION
Reconnect the trunk to
the T1/R1 or T2/R2 of the
telephone jack using
2-conductor wiring.
8.1.3
Operation
PROBLEM
PROBABLE CAUSE
SOLUTION
The HANDSET/
HEADSET selector is
set to the "HEADSET"
position.
operate.
A DPT or APT is
connected to the
extension port.
Originating an outside
call, call transfer, or
conference cannot be
performed.
The corresponding CO
button does not exist on
the PT.
Wrong Personal
Identification Number
(PIN) is registered to the
PS.
Register the PIN set to the Hybrid IPPBX into the PS.
CS is not connected
properly.
PS becomes out of
range.
Cannot make calls using
the PS.
CS is not working.
Location of CS is not
good.
Installation Manual
407
PROBLEM
408
PROBABLE CAUSE
Installation Manual
SOLUTION
working.
PS is out of CS coverage
area.
It may take about 10 s
for CS to start up after
the status has been
changed to In Service.
8.1.4
1. When the System Initialise Switch is set to "NORMAL", pressing the Reset Button
causes the following:
Camp-on is cleared.
2. When the System Initialise Switch is set to the "SYSTEM INITIALIZE" position, you
must press the Reset Button with caution, because all data stored in memory will be
cleared by the following operation: (1) pressing the Reset Button and then, (2) setting
the System Initialise Switch to the "NORMAL" position while the RUN indicator is
flashing (within approximately 10 s).
Operation
1. If the Hybrid IP-PBX does not operate properly:
a. Make sure that the System Initialise Switch is set to the "NORMAL" position.
b. Press the Reset Button.
RUN Indicator
ALARM Indicator
Reset Button
System Initialise Switch
Installation Manual
409
410
Installation Manual
8.1.5
Description
Item
Description
Date
Time
Level
Error Code
Installation Manual
411
Item
5
Sub Code
Description
Five-digit sub code (1XXYY)
1: Cabinet number
XX: Slot number
00 to 11 (00: MPR; 01: Super hybrid ports; 02 to 11: Slots
for optional service cards)
YY: Physical port number (01 to 16)
For optional service cards that are installed in Slots 08 to
11, sub slot number + port number will be displayed.
Sub slot 1: 11 to 14
Note
When there is no parameter for slot and physical port
number, XX and YY will be displayed as "00".
Example: Sub code for MPR = 10000
412
Error Message
Installation Manual
When the errors "021", "091", "092", and "510" are logged: when the error
conditions are recovered
When other errors are logged: when the log for major or minor errors is cleared from
the KX-TDA30 Maintenance Console
Error Message
PROBABLE CAUSE
SOLUTION
212
Echo canceller
access error
215
Framer IC access
error
216
217
Error Message
PROBABLE CAUSE
000*
MPR WDT
overflow
001
SOLUTION
Installation Manual
413
Error Code
002
Error Message
System Restart
PROBABLE CAUSE
010
AC power down
SOLUTION
Reset Button is
pressed
Power failure
Main Board
malfunction
Erroneous processing
of Main Board software
Software error due to
external factors
AC power down
Bad connection or
breaking of AC cord
011
DC power down
AC power down
Power supply circuit
(Main Board)
malfunction
Detection of over
current (short circuit on
optional service cards)
012*
MPR RAM
battery low
Battery out
Main Board (MPR)
malfunction
013
Additional AC
power down
Additional AC power
down
Bad connection or
breaking of additional
AC cord
Defective cable
Defective ISDN
terminal equipment
Optional service card
malfunction: BRI
017
414
Installation Manual
Error Code
Error Message
PROBABLE CAUSE
SOLUTION
019
Additional AC
power on
Additional AC power on
Bad connection or
breaking of additional
AC cord
020*
SD file access
error
SD Memory Card
malfunction
Bad connection of SD
Memory Card
Main Board
malfunction
021*
SD Memory Card
disconnected
022
Installation Manual
415
Error Code
Error Message
PROBABLE CAUSE
023
024
System
initialization file
version error
025
Card initialization
file version error
026
027
028
System
initialization file
checksum error
029
Card initialization
file checksum
error
030
LCD file
checksum error
031*
032*
System
initialization file
not found
SOLUTION
033*
Card initialization
034*
035
036*
System
initialization file
access error
037*
Card initialization
file access error
038*
090
Over Card
Limitation
091*
PT connection
over
092*
CS connection
over
416
Installation Manual
Error Code
230*
Error Message
Card
disconnected
PROBABLE CAUSE
SOLUTION
234
251
305*
307
LAN No Carrier
308
Detection of IP-GW
LAN Loop back Test
error
309
Detection of IP-GW
Core data Link error
310*
Voice Processing
System malfunction
Ports defective on
optional service card:
DLC
Installation Manual
417
Error Code
320
321
Error Message
PROBABLE CAUSE
SOLUTION
IP-GW H.323
Detection of IP-GW
H.323 Dummy Call
Test error
IP-GW
Gatekeeper Error
Detection of
Gatekeeper access
error
322
IP-GW
Gatekeeper
Registration Error
Gatekeeper
Registration is failed
323
IP-GW SDRAM
Failure
Detection of IP-GW
SDRAM error
324
IP-GW DPRAM
Failure
Detection of IP-GW
DPRAM error
325
Detection of IP-GW
LAN Chip failure
IP-GW Rebooted
by Maintenance
Console
IP-GW is rebooted
from a remote
maintenance PC
371
IP-GW Rebooted
391
Data Link
established
Connection with PC
Phone/PC Console or
Voice Processing
System (DPT
Integration)
established or restored
392
393
LAN Carrier
detected
326
IP-GW Stop
370
418
Installation Manual
Error Code
Error Message
PROBABLE CAUSE
SOLUTION
394
395
IP-GW
Gatekeeper Error
Cleared
Connection to the
Gatekeeper is
recovered
396
IP-GW Run
510*
SMDR disconnect
Installation Manual
419
420
Installation Manual
Section 9
Appendix
Installation Manual
421
9.1
Revision History
9.1.1
New Options
KX-TDA0105
KX-TDA0182
KX-TDA0183
KX-TDA0484
KX-TDA0143
KX-TDA0141CE
2-Channel Cell Station Unit Using a DHLC/DLC Card (PTinterface CS) for DECT Portable Station
KX-TDA0141
2-Channel Cell Station Unit Using a DHLC/DLC Card (PTinterface CS) for 2.4 GHz Portable Station
New Contents
Changed Contents
422
Installation Manual
9.1.2
New Options
KX-TDA3183
KX-TDA3105
Changed Contents
Installation Manual
423
424
Installation Manual
Index
Installation Manual
425
Index
Numerics
16-Channel Echo Canceller Card (KX-TDA0166)
27, 125
16-Port Analogue Trunk Card (KX-TDA0181)
28, 75
16-Port Digital Extension Card (KX-TDA0172)
27, 113
16-Port Single Line Telephone Extension Card (KX-TDA0174)
27,
117
16-Port Single Line Telephone Extension with Message Lamp Card (KX28, 117
TDA0175)
2-Channel Message Card (KX-TDA3191)
243, 307
2-Port Analogue Trunk Card (KX-TDA3183)
243, 287
2-Port BRI Card (KX-TDA3280)
244, 289
2-Port Doorphone Card (German Type) (KX-TDA0162)
27, 122
2-Port Doorphone Card (German Type) (KX-TDA3162)
243, 303
4 Cell Station Interface Card (KX-TDA0143)
27, 106
4-Channel Message Card (KX-TDA0191)
28, 126
4-Channel VoIP Gateway Card (KX-TDA0480)
29, 101
4-Channel VoIP Gateway Card (KX-TDA0484)
29, 104
4-Channel VoIP Gateway Card (KX-TDA3480)
244, 292
4-Port Analogue Trunk Card (KX-TDA0183)
28, 75
4-Port Analogue Trunk Card (KX-TDA3180)
243, 285
4-Port BRI Card (KX-TDA0284)
28, 90
4-Port Caller ID Card (KX-TDA3193)
243, 288
4-Port Digital Extension Card (KX-TDA3171)
243, 294
4-Port Doorphone Card (KX-TDA0161)
27, 120
4-Port Doorphone Card (KX-TDA3161)
243, 300
4-Port Single Line Telephone Extension Card (KX-TDA3173)
243,
296
8 Cell Station Interface Card (KX-TDA0144)
27, 106
8-Channel Echo Canceller Card (KX-TDA3166)
243, 306
8-Port Analogue Trunk Card (KX-TDA0180)
28, 75
8-Port BRI Card (KX-TDA0288)
29, 90
8-Port Caller ID Card (KX-TDA0193)
28, 80
8-Port Caller ID/Pay Tone Card (KX-TDA0189)
28, 79
8-Port DID Card (KX-TDA0182)
28, 77
8-Port Digital Extension Card (KX-TDA0171)
27, 111
8-Port Digital Extension Card (KX-TDA3172)
243, 297
8-Port Digital Hybrid Extension Card (KX-TDA0170)
27, 108
8-Port E & M Trunk Card (KX-TDA0184)
28, 81
8-Port Single Line Telephone Extension Card (KX-TDA0173)
27,
115
8-Port Single Line Telephone Extension Card (KX-TDA3174)
243,
299
A
About the Other Manuals
11
AC Adaptor Capability
250
AC Adaptor Selection (With BRI Extension Port)
250
AC Adaptor Selection (Without BRI Extension Port)
249
Additional AC Adaptor (KX-A236)
244
After Site Survey
154, 180, 338, 361
Amphenol Connector Pin Assignment Chart
60
Appendix
421
Attaching a Ferrite Core
57
B
Backup Batteries Connection
49, 263
Basic Shelf
24
Basic System Construction KX-TDA100/KX-TDA200
Basic System Construction KX-TDA30
240
426
Installation Manual
24
Before Installation
38, 254
Before Installation KX-TDA100/KX-TDA200
38
Before Installation KX-TDA30
254
Before Site Survey
146, 174, 330, 355
BRI2 Card
289
BRI4 and BRI8 Cards
90
Built-in Small Call Centre Features
22, 238
C
Calculation Example
249, 251
Calculation Example (KX-TDA100)
34
Calculation Example (KX-TDA200)
36
Changed Contents
422, 423
Characteristics
32, 247
CID/PAY8 Card
79
CID4 Card
288
CID8 Card
80
Computer Telephony Integration (CTI) Features
22, 238
Confirming the Trunk Connection
204, 390
Connecting a Cell Station to the Hybrid IP-PBX
155, 181, 339,
362
Connection
207, 221, 393, 405
Connection of 2.4 GHz Portable Stations KX-TDA100/KX-TDA200
166
Connection of 2.4 GHz Portable Stations KX-TDA30
348
Connection of DECT Portable Stations KX-TDA100/KX-TDA200
138
Connection of DECT Portable Stations KX-TDA30
322
Connection of Doorphones and Door Openers KX-TDA100/KX191
TDA200
Connection of Doorphones and Door Openers KX-TDA30
371
Connection of Extensions KX-TDA100/KX-TDA200
129
Connection of Extensions KX-TDA30
313
Connection of Peripherals
194, 381
Connection of Peripherals KX-TDA100/KX-TDA200
194
Connection of Peripherals KX-TDA30
381
Connection KX-TDA100/KX-TDA200
207
Connection KX-TDA30
393
Construction of Basic Shelf
24
Construction of Main Unit
240
Covering the Blank Slots
52
CSIF4 and CSIF8 Card
106
CTI Link Card (KX-TDA0410)
29, 127
CTI-LINK Card
127
CTIFirst Party Call Control
137, 321
CTIThird Party Call Control
127, 197, 384
D
DHLC8 Card
108
DID8 Card
77
Digital EXtra Device Port (Digital XDP) Connection
132, 316
Digital XDP
132, 316
DLC16 Card
113
DLC4 Card
294
DLC8 Card
111, 297
Door Opener
120, 122, 191, 300, 303, 371
Doorphone
120, 122, 191, 300, 303, 371
DPH2 Card
122, 303
DPH4 Card
120, 300
Index
E&M8 Card
81
E1 Card
87
E-1 Trunk Card (KX-TDA0188)
28, 87
ECHO16 Card
125
ECHO8 Card
306
EXT-CID Card
308
Extension Caller ID Card (KX-TDA3168)
243, 308
EXtra Device Port (XDP) Mode
130, 132, 314, 316
F
Fastening Amphenol Type Connector
59
First Party Call Control CTI Connection
137, 321
Floor Standing (KX-TDA200 Only)
65
Frame Earth Connection
48, 262
G
General Description
30, 245
Guide for the KX-TDA Maintenance Console KX-TDA100/KXTDA200
205
Guide for the KX-TDA30 Maintenance Console KX-TDA30
391
H
Handling of the Cables
53, 270
Hybrid IP-PBX Configuration
214, 400
Hybrid IP-PBX Maintenance
215, 401
I
Installation of the Extension Cards KX-TDA100/KX-TDA200
106
Installation of the Extension Cards KX-TDA30
294
Installation of the Hybrid IP-PBX KX-TDA100/KX-TDA200
40
Installation of the Hybrid IP-PBX KX-TDA30
256
Installation of the KX-TDA Maintenance Console KX-TDA100/KXTDA200
209
Installation of the KX-TDA30 Maintenance Console
395
Installation of the Main Processing Card KX-TDA100/KX-TDA200
71
Installation of the Other Cards KX-TDA100/KX-TDA200
119
Installation of the Other Cards KX-TDA30
300
Installation of the SD Memory Card
261
Installation of the Trunk Cards KX-TDA100/KX-TDA200
75
Installation of the Trunk Cards KX-TDA30
285
Installation Precautions
38, 254
Installation KX-TDA100/KX-TDA200
37
Installation KX-TDA30
253
Installing and Starting the KX-TDA Maintenance Console
209
Installing and Starting the KX-TDA30 Maintenance Console
395
Installing the KX-TDA Maintenance Console and Selecting Appropriate
Country/Area Data
210
Installing the KX-TDA30 Maintenance Console and Selecting Appropri396
ate Country/Area Data
Installing/Removing the Optional Service Cards
50, 264
Installing/Replacing the Power Supply Unit
44
IP-GW4 Card
101, 292
IP-GW4E Card
104
Installation Manual
427
Index
LCOT2 Card
287
LCOT4 Card
285
LCOT4, LCOT8, and LCOT16 Cards
75
Lightning Protector Installation
68, 282
L-Type Power Supply Unit (KX-TDA0103)
29, 44
M
Main Unit
240
Maximum Cabling Distances of the Extension Wiring (Twisted Cable)
129, 313
Maximum Terminal Equipment
33, 248
Maximum Trunk and Extension Cards
33
Maximum Trunk and VoIP Line
248
MEC Card
73, 309
MEC Card Calculation
34, 249
Memory Expansion Card (KX-TDA0105)
27, 73
Memory Expansion Card (KX-TDA3105)
243, 309
MPR Card
71
MSG2 Card
307
MSG4 Card
126
M-Type Power Supply Unit (KX-TDA0104)
29, 44
N
Names and Locations
41, 257
Networking Features
22, 238
New Contents
422
New Options
422, 423
O
OPB3 Card
119
Opening/Closing the Covers
258
Opening/Closing the Front Cover
42
Operation
223, 407
Optional 3-Slot Base Card (KX-TDA0190)
28, 119
Options
27, 243
Options KX-TDA100/KX-TDA200
27
Options KX-TDA30
243
Overview
138, 166, 206, 322, 348, 392
Overview KX-TDA100/KX-TDA200
206
Overview KX-TDA30
392
P
Parallel Connection of the Extensions
130, 314
Parallel Mode
130, 132, 314, 316
Parallelled Telephone Features
23, 239
Password Security
209, 395
PC Phone/PC Console Features
23, 239
Portable Station (PS) Features
23, 239
Power Failure Connections
198, 385
Power Failure Connections KX-TDA100/KX-TDA200
Power Failure Connections KX-TDA30
385
Power Supply Unit Selection
35
PRI Card (PRI23) (KX-TDA0290)
29, 98
PRI Card (PRI30) (KX-TDA0290CE/CJ)
29, 94
PRI23 Card
98
PRI30 Card
94
Procedure Overview
140, 168, 324, 349
428
Installation Manual
S
Safety Installation Instructions
38, 254
Safety Instructions
44
SAFETY REQUIREMENTS
6
SD Memory Card
71, 261
Site Planning
142, 170, 326, 351
Site Survey
176, 357
Site Survey Using the KX-TCA255/KX-TD7590
150, 334
SLC16 and MSLC16 Cards
117
SLC4 Card
296
SLC8 Card
115, 299
Slot Position
264
Slot Restrictions
264
Specifications KX-TDA100/KX-TDA200
30
Specifications KX-TDA30
245
Starting the Hybrid IP-PBX
202, 387
Starting the Hybrid IP-PBX KX-TDA100/KX-TDA200
202
Starting the Hybrid IP-PBX KX-TDA30
387
Starting the KX-TDA Maintenance Console and Assigning the Basic
210
Items (Quick Setup)
Starting the KX-TDA30 Maintenance Console and Assigning the Basic
Items (Quick Setup)
396
Structure of the KX-TDA Maintenance Console
213
Structure of the KX-TDA30 Maintenance Console
399
S-Type Power Supply Unit (KX-TDA0108)
29, 44
System Capacity
33, 248
System Components Table for KX-TDA100/KX-TDA200
2
System Components Table for KX-TDA30
3
System Connection Diagram
25, 241
System Highlights
22, 238
System Highlights KX-TDA100/KX-TDA200
22
System Highlights KX-TDA30
238
System Outline KX-TDA100/KX-TDA200
21
System Outline KX-TDA30
237
198
T1 Card
84
T-1 Trunk Card (KX-TDA0187)
28, 84
The Structure of this Manual
11
Troubleshooting by Error Log
227, 411
Troubleshooting KX-TDA100/KX-TDA200
Troubleshooting KX-TDA30
403, 404
Turning off the Hybrid IP-PBX
390
Types of Connectors
55, 274
U
Unpacking
40, 256
Using a CSIF Card
155, 181
Using a DHLC/DLC Card
156, 182
219, 220
Index
V
Voice Mail Features
22, 238
W
Wall Mounting (AC Adaptor)
279
Wall Mounting (CS)
164, 189, 346, 369
Wall Mounting (KX-TDA100)
63
Wall Mounting (KX-TDA200)
61
Wall Mounting (KX-TDA30)
276
Wiring Precautions
38, 254
Installation Manual
429
Index
430
Installation Manual
Install a
screw here.
120 mm
Install a
screw here.
240 mm
250 mm
130 mm
65 mm
Copyright:
This manual is copyrighted by Panasonic Communications Co., Ltd. (PCC). You may print out this manual
solely for internal use with this model. Except above, you may not reproduce this manual in any form, in
whole or part, without the prior written consent of PCC.
2003 Panasonic Communications Co., Ltd. All Rights Reserved.
PSQX2633WA KK0103AH4034