Professional Documents
Culture Documents
Fluke - Troubleshooting Motor Ignitions
Fluke - Troubleshooting Motor Ignitions
Outboard Motor
Magneto Ignitions
Application Note
Coil
23
SERIES II MULTIMETER
Primary
Flywheel
Secondary
Introduction
10
20
OFF
30
40
300mV
A
PRESS
RANGE
AUTORANGE
TOUCH HOLD
1 SEC
10A
! 100V
300
mA
750V
FUSED
Breaker
Points
Condenser
Engine Block
Troubleshooting procedure
COM
23
Secondary
Primary
20
30
40
300mV
A
PRESS
RANGE
AUTORANGE
TOUCH HOLD
! 100V
300
mA
750V
FUSED
Breaker
Points
Condenser
Engine Block
SERIES II MULTIMETER
Secondary
k
10
20
OFF
30
40
300mV
A
PRESS
RANGE
AUTORANGE
TOUCH HOLD
1 SEC
10A
! 100V
750V
COM
Secondary
Coil
HV circuit repairs
1 SEC
10A
FUSED
10
OFF
SERIES II MULTIMETER
Flywheel
300
mA
2 Fluke Corporation
Coil
Primary
Primary
COM
Coil
10
20
OFF
SERIES II MULTIMETER
30
40
Flywheel
Primary
300mV
Secondary
23
A
PRESS
RANGE
AUTORANGE
TOUCH HOLD
1 SEC
10A
! 100V
300
mA
750V
COM
FUSED
Breaker
Points
Condenser
Engine
Block
Condenser test
Next check the condenser as
follows: Disconnect the condenser
lead, then place the multimeter in
the capacitance function and hold
one test lead to the capacitor case
and the other to the terminal. (See
Figure 5).
23
10
20
OFF
SERIES II MULTIMETER
30
40
300mV
A
PRESS
RANGE
AUTORANGE
TOUCH HOLD
1 SEC
10A
! 100V
300
mA
750V
COM
FUSED
Fluke Corporation 3
26
73
MULTIMETER
27 MULTIMETER
VAC
10
20
MIN
OFF
30
30
10
20
30
V
RANGE
40
V
300mV
CAT
HOLD
600V
600A
1000A
CAL
Hz 20kHz
V 1kHz
mV
REL
RANGE
HOLD H
MIN/MAX
MAX
Hz
RESET
MIN MAX
40
200 A
OFF
600 A
1000 A
200
OFF
mV
mV
200 V
600 V
OFF
mA/A
mA/A
PRESS
DC / AC
A ZERO
MANUAL RANGE
AUTORANGE
TOUCH HOLD
36 CLAMP METER
10A
V
40
mA
600V CAT
300
mA
FUSED
!
10A MAX
OFF
10A
FUSED
DC
!
1000V MAX
600V CAT
1000V CAT
COM
mA
A
COM
!
320 mA MAX
TRUE RMS
600V
COM
COM
Fluke 12B
Fluke 27
Touch Hold
Same features as
Fluke 73 Series III,
plus:
Rugged, overmolded
case
electrical test
Tough,
lead set with
silicone insulation
and alligator clip
True-rms ac voltage
AC/DC current with
ranges from 4.0 mA
to 10A
Lo Ohms
Fully sealed,
captures stable
readings
Auto and manual
ranging
Holster with FlexStand included
Volts ac and dc
Resistance
Diode test/
continuity beeper
AC/DC current with
ranges from 32 mA
to 10A
waterproof case
Hold
Touch
captures stable
readings
Volts, ohms, amps,
continuity, diode
test
Current with ranges
from 320 A to 10A
Fluke 36
ClampMeter
True-rms
responding
AC current to 600A
DC current to 1000A
AC and DC voltage
to 600 Volts
Max Hold
Continuity beeper