Professional Documents
Culture Documents
Hawke Catalogue PDF
Hawke Catalogue PDF
Over the past 45 years, Hawke has built a world-wide reputation in the Hazardous Area and Hostile Environment markets,
with an innovative range of cable connection, termination and barrier products.
The underlying philosophy behind our Corporate Strategy has been a recognition of the fundamental principle that our
products are concerned with safety, in an environment where failure can have catastrophic consequences to human life, the
environment, expensive plant and valuable production - and in situations where the replacement of faulty components is often
difficult.
This philosophy requires an enthusiastic participation in the development of new Safety Standards and Codes of Practice, and a
product development programme which embraces these, together with advances in cable construction and materials. It
requires that our products should be easy to select and install, because these activities are not only expensive but also affect
the safety of the assembly. It requires that we provide informed technical advice, that our staff and customers are thoroughly
trained, and that we have quality systems and a manufacturing plant which ensure Zero Defects. It means that we must
transcend the mere requirements of having the "appropriate certification" and that we exceed the undemanding requirement
that products be "fit for purpose" - whose purpose?
All the products we make (from Fire Barrier Transit systems to Fieldbus Power Supply systems) have a common underlying
theme, which forms the basis of our Product Development Strategy :Safety, Integrity and Inspectability
Versatility and ease of product selection
Quality and Reliability
Ease and speed of use
Lowest lifetime cost solutions
Product Development is an ongoing process, in which Hawke continues to invest heavily, and the cable glands described within
are the culmination of a particularly concentrated effort over recent years.
An example from our new range of cable glands illustrate these principles :The new rear sealing system not only meets the new ATEX Directive, but also uses a unique clamping system, giving
higher retention forces than any other similar product on the market. It uses a new thermoset elastomer compound
which provides superb resistance to high and low temperatures, to the ageing effects of Oxygen and Ozone, and
Compression Set. It has the added benefit of being halogen-free, with low smoke and fume emission . . . . but, above all,
it is safe.The system has the versatility to seal the entire range of cable sizes that can be accommodated by a
particular entry size, without the need for special outer seals.This makes the cable gland easier and quicker to use,
with less likelihood of an installer using the wrong seal. It also means easier product selection, and fewer items for our
distributors to keep in stock, which should in turn mean improved stock availability.The cable acceptance range is
marked on the rear nut, affording easier inspectability.
As a company, we have all the obvious targets in terms of On-Time Delivery and Customer Service, Zero Defects, Investment
in Manufacturing Facilities, and in the Training and Development of our People - and we perform to World-Class Standards,
but . . . .
Smarter products
www.ehawke.com
Contents
Page No.
Cable Gland Selection Chart
4-6
7 - 20
21 - 27
28 - 32
33 - 37
38
39 - 66
39
39
39 - 43
39
40
40
41
41
42
42
42
43
43 - 44
44
45 - 48
45
46
48
Smarter products
www.ehawke.com
International
2
Contents
Page No.
6.0 Apparatus Marking - CENELEC and IEC (Group II)
6.1 Additional ATEX Marking
6.2 Additional CE Marking
48 - 49
48
49
7.0 CE Marking
7.1 EMC, Electromagnetic Compatibility Directive
7.2 Low Voltage Directive
49
49
49
8.0 Certification/Listing/Approvals
49
50 - 56
51
51
51
51
53
54
54
54
55
56
56 - 61
56
57
57
57
58
60
60
61
62 - 65
Smarter products
www.ehawke.com
International
3
Pictorial View
Colour
Coded Cable Gland
Catalogue
Type
Page No.
501/421
10
11
12
501/423
501/453/RAC
15
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
ATEX
EExd IIC/EExe II
II 2 GD
501/453/UNIV
Zone 1, 2, 21 & 22
PSG 553/RAC
ICG 623
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
ATEX
EExd IIC/EExe II
II 2 GD
ICG 653/UNIV
Zone 1, 2, 21 & 22
ATEX
EExd IIC/EExe II
II 2 GD
ICG 653/UNIV/L
Zone 1, 2, 21 & 22
16
Smarter products
www.ehawke.com
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
ATEX
EExd IIC/EExe II
501/453/RAC/L
II 2 GD
Zone 1, 2, 21 & 22
13
14
Certification
501/414
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
Certification
Options
Application/Cable Type
Ingress
Protection
Sealing
Indoor/outdoor
Non-armoured cable
IP66/67/68
Deluge
Outer cable
sheath seal
Indoor/outdoor
Non-armoured cable
Two outer
IP66/67/68
cable sheath seals
Deluge
Indoor/outdoor
Armoured/braided cable with
inner and outer sheath
Indoor/outdoor
Armoured/braided cable with
inner lead sheath and
outer sheath
Indoor/outdoor
Armoured/braided cable with
inner and outer sheath
IP66/67/68
Deluge
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
IEC
Indoor/outdoor
IP66/67/68
Armoured/braided cable with
(Deluge
inner (optional) and outer sheath option)
Inner (diaphragm)
and outer
cable sheath seals
Individual
conductor seal
and outer
cable sheath seal
Indoor/outdoor
Non-armoured cable
Indoor/outdoor
Inner (compound)
IP66/67/68
Armoured/braided cable with
and outer
Deluge
inner (optional) and outer sheath
cable sheath seals
Indoor/outdoor
Armoured/braided cable with
inner lead sheath and
outer sheath
Indoor/outdoor
Non-armoured cable,
conduit system
Inner (compound)
seal, lead sheath
IP66/67/68
electrical bond
Deluge
and outer
cable sheath seal
IP66/67/68
Deluge
Outer cable
sheath seal
International
4
Pictorial View
Colour
Coded Cable Gland
Catalogue
Type
Page No.
17
SB 474
18
19
CSB 656
501/453
ICG 653
153
Sizes G, H & J
351/RAC
20
Certification
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
ATEX
EExe II
II 2 GD
Zone 1, 2, 21 & 22
EN 50262
21
121
22
123
23
150/RAC
24
151/RAC
25
153/RAC
26
153/RAC/L
27
114
Smarter products
www.ehawke.com
EN 50262
BS 6121
EN 50262
EN 50262
EN 50262
EN 50262
Certification
Options
IEC
IEC
IEC
Application/Cable Type
Ingress
Protection
Sealing
Indoor/outdoor
Individual conductors,
conduit system
IP66/67/68
Deluge
Indoor/outdoor
Individual conductors,
conduit system
Individual
IP66/67/68
conductor
Deluge
(compound) seal
Indoor/outdoor
Armoured/braided cable with
inner and outer sheath
Individual
conductor
seal
IEC
Indoor/outdoor
Armoured/braided cable with
inner (optional) and outer sheath
IP66
(Deluge
option)
Outer cable
sheath seal
IEC
Indoor/outdoor
Non-armoured cable
IP66/67/68
Deluge
Outer cable
sheath seal
IEC
Indoor/outdoor
Non-armoured cable
Two outer
IP66/67/68
cable sheath seals
Deluge
IEC
Dry Indoor/outdoor
Armoured/braided cable with
inner (optional) and outer sheath
IEC
Indoor/outdoor
Armoured/braided cable with
inner (optional) and
outer sheath
IP66
(Deluge
option)
Outer cable
sheath seal
IEC
Indoor/outdoor
Armoured/braided cable
with inner and outer
cable sheath
IP66/67
(Deluge
option)
Inner (diaphragm)
and outer
cable sheath seal
IP66/67
(Deluge
option)
Inner seal/lead
sheath electrical
bond and outer
cable sheath seal
IP66/67/68
Deluge
Outer cable
sheath seal
IEC
IEC
Indoor/outdoor
Armoured/braided cable with
inner lead sheath and
outer sheath
Indoor/outdoor
Non-armoured cable,
conduit system
International
5
Pictorial View
Colour
Coded Cable Gland
Catalogue
Type
Page No.
28
701
Certification
Certification
Options
UL/cUL
UL 514B
Application/Cable Type
Ingress
Protection
Sealing
Indoor/outdoor
Type MC and Teck cables
IP66/67/68
Deluge
Outer cable
jacket seal
Indoor/outdoor
Type MC and Teck cables
IP66/67/68
Deluge
Inner (compound)
and outer cable
jacket seals
29
711
30
710
31
753
32
755
33 - 36
Accessories
33 - 36
Accessories
33 - 36
Accessories
37
Adaptors/
Reducers
38
UL/cUL
Class 1 Division 2
Groups
A, B, C & D
Indoor/outdoor
Armored Marine
Shipboard cable
Indoor/outdoor
Armored/braided cable with
inner (option) and outer jacket
UL/cUL
Class 1 Division 1
Groups
A, B, C & D
UL/cUL
Class 1 Division 2
Groups
A, B, C & D
ATEX
EExd IIC/EExe II
II 2 GD
Zone 1, 2, 21 & 22
Indoor/outdoor
Non-armored cable
Indoor/outdoor
IP66/67/68
Deluge
IEC
Cable Gland
Variations
& Options
Smarter products
www.ehawke.com
UL/cUL
Class 1 Division 1
Groups
A, B, C & D
International
6
ATEX
15.0mm
'G' Approx
Metric
Entry
'B'
Entry Thread
Function
Provides a high pullout resistant seal onto
the cables outer sheath.
When used in increased safety applications,
this cable gland may be used with braided
cable where the braid and the cables outer
sheath pass into the enclosure.
The braid must be suitably terminated
into the enclosure.
H
J
Technical Data
Smarter products
www.ehawke.com
Entry Thread
Size
Size
Ref.
Metric NPT
*
Os M20
"
"
O M20
A
M20
"
M25
B
"
M32
C
1"
C2 M40 1"
2"
D
M50
E
M63 2"
3"
M75
F
G
M80
'G'
Hexagon
Dimensions
38
39
38
41
43
42
58
53
56
56
56
56
Across Across
Flats Corners
24.0
27.7
24.0
27.7
34.6
30.0
41.6
36.0
46.0
53.1
55.0
63.5
75.1
65.0
92.4
80.0
95.0 109.6
106.4 123.0
115.0 132.8
127.0 146.7
International
7
ATEX
15.0mm
'G' Approx
Metric
Entry
'B'
Entry Thread
Size
Ref.
Os
O
A
Function
B
C
C2
D
E
F
G
H
J
Smarter products
www.ehawke.com
Metric NPT
*
M20
"
M20
"
M20
M25
M32
M40
M50
M63
M75
M80
M90
M100
"
"
1"
1"
2"
2"
3"
3"
4"
'G'
67
68
64
69
72
73
100
98
100
Hexagon
Dimensions
Across Across
Flats Corners
24.0
27.7
24.0
27.7
34.6
30.0
36.0
46.0
41.6
53.1
55.0
65.0
80.0
95.0
106.4
100
100 115.0
100 127.0
63.5
75.1
92.4
109.6
123.0
132.8
146.7
Technical Data
Entry Thread
Size
International
8
ATEX
15.0mm
'G' Approx
'B'
Entry Thread
Armour/Braid
'C'
'A'
Metric
Entry
Technical Data
Smarter products
www.ehawke.com
'G'
81
81
83
95
98
105
133
126
134
Hexagon
Dimensions
Across Across
Flats Corners
24.0
27.7
24.0
27.7
30.0
34.6
41.6
36.0
46.0
53.1
55.0
63.5
65.0
75.1
80.0
92.4
95.0
109.6
121 106.4
121 115.0
121 127.0
123.0
132.8
146.7
International
9
ATEX
15.0mm
'B'
Entry Thread
Armour/Braid
'C'
Lead Sheath
Bond
'A'
Metric
Entry
'G' Approx
Application
Outdoor or Indoor use.
For use with single wire
armoured 'W', wire braided 'X'
and steel tape armoured 'Z'
cables with a lead inner sheath.
See technical section of catalogue
for installation rules and regulations
Function
Technical Data
Flameproof EExd IIC and Increased
Safety EExe II.
II 2 GD
BASEEFA Certificate No.
BAS 01 ATEX 2072X. Fos sizes O - F.
BASEEFA Certificate No.
BAS 01 ATEX 2296X. For sizes G - J.
Suitable for use in Zone 1, Zone 2
Zone 21 and Zone 22.
Suitable for use in Gas Groups
IIA, IIB and IIC.
Construction and test standards
EN 50014, EN 50018, EN 50019
and EN 50281-1-1.
IEC 60079-0, IEC 60079-1 and
IEC 60079-7.
IP66, IP67 and IP68 ingress
protection
to IEC 60529, EN 60529 and
NEMA 4X.
Operating temperature range
-60C to +80C as standard.
M20
M25
M32
M40
M50
M63
M75
"
7.5
-
8.5
-
"
" 13.0 16.7
1" 19.0 22.5
1" 25.0 28.5
2" 31.5 40.3
2" 42.0 52.0
3" 54.5 63.8
8.5
11.0
15.5
22.0
27.5
39.0
51.0
10.8
15.4
21.2
28.0
34.8
46.5
58.3
9.5 16.0
12.5 20.5
16.9 26.0
22.0 33.0
28.0 41.0
36.0 52.6
46.0 65.3
57.0 78.0
'G'
Across Across
Flats Corners
Orientation Orientation
2
1
0.9/1.25
0.9/1.25
1.25/1.6
1.6/2.0
1.6/2.0
1.8/2.5
1.8/2.5
1.8/2.5
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/1.0
0/1.0
0/1.0
#
#
#
#
#
#
Hexagon
Dimensions
81
83
95
98
105
133
126
134
24.0
30.0
36.0
46.0
55.0
65.0
80.0
95.0
27.7
34.6
41.6
53.1
63.5
75.1
92.4
109.6
G
H
J
M80
59.9
M90 3" 68.9
M100 4" 79.4
68.5
73.1
87.1
75.0 89.5
75.0 89.5
88.0 104.5
121 106.4
121 115.0
121 127.0
123.0
132.8
146.7
Smarter products
www.ehawke.com
M20
'C'
Armour/Braid
International
10
ATEX
'G' Approx
15.0mm
Armour/Braid
'C'
'B'
Entry Thread
Diaphragm
Seal
Deluge
Boot
'A'
Metric
Entry
Entry Thread
Inner Sheath
Size
Size
'A'
Ref.
NPT
Min. Max.
Metric
*
Os M20
8.1
" 3.0
" 7.5 11.9
O M20
A M20 " 9.4 14.3
" 12.1 20.2
B M25
1"
17.6 26.5
C M32
1"
M40
23.1 32.5
C2
2"
D M50
28.9 44.4
E M63 2" 39.9 56.3
3" 50.5 68.2
F M75
Function
Max.
5.5
9.5
12.5
16.9
22.0
28.0
36.0
46.0
57.0
12.0
16.0
20.5
26.0
33.0
41.0
52.6
65.3
78.0
Orientation Orientation
2
1
0.9/1.25
0.9/1.25
0.9/1.25
1.25/1.6
1.6/2.0
1.6/2.0
1.8/2.5
1.8/2.5
1.8/2.5
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/1.0
0/1.0
0/1.0
'G'
Hexagon
Dimensions
Across Across
Flats Corners
87 24.0
27.7
87
24.0
27.7
34.6
89 30.0
41.6
100 36.0
103 46.0
53.1
55.0
63.5
110
75.1
133 65.0
92.4
134 80.0
140 95.0 109.6
Larger cable glands available in 501/453 design as shown below. See page 19
G
H
J
M80
67.0
M90 3" 67.0
M100 4" 75.0
73.0
77.6
91.6
75.0 89.5
75.0 89.5
88.0 104.5
#
#
#
#
121
121
121
106.4
123.0
115.0
127.0
132.8
146.7
Technical Data
Smarter products
www.ehawke.com
International
11
ATEX
15.0mm
'G' Approx
Armour/Braid
'C'
Metric
Entry
'B'
Entry Thread
Function
Technical Data
'G'
Hexagon
Dimensions
Across Across
Flats Corners
34.6
88 30.0
41.6
99 36.0
53.1
101 46.0
Maximum No.
of Cores
1.5
2.5
4.0
6.0
10.0
7
4
3
A&B
-
A&B
-
B&C
-
C
B
-
C
B
No.1
1.5
No.1
2.5
No.2
4.0
No.2
6.0
No.3
10.0
Smarter products
www.ehawke.com
International
12
ATEX
15.0mm
'G' Approx
Inspectable
Compound
'B'
'D'
Entry Thread
'E'
Metric
Entry
Function
Provides a barrier seal between the individual
insulated cores within the cable and prevent
entry of the products of an explosion into
the cable.
Assembly of the cable gland compresses
and distributes the compound evenly to
effect a barrier seal at the point of entry
into the enclosure.
The compound chamber may be
seperated from the compound to
ensure that the chamber has been
effectively filled.
Provides a high pullout resistance and
low smoke and fume, zero halogen
seal onto the cables outer sheath.
Os
O
A
B
C
C2
D
E
F
Entry Thread
Size
Metric NPT
*
M20
M20
M20
M25
M32
M40
M50
M63
M75
Max.
Over
Cores
Max.
Inner
Sheath
8.0
8.9
11.0
16.2
21.9
1"
1" 26.3
37.1
2"
2" 47.8
59.0
3"
8.0
10.0
12.5
18.4
24.7
29.7
41.7
"
"
"
"
No.
Of
Cores
6
6
10
21
42
60
80
53.5 100
66.2 120
Min. Max.
Min.
Max.
3.0
7.5
11.0
13.0
19.0
25.0
8.5
9.5
15.5
22.0
27.5
39.0
48.5
13.4
15.4
21.2
28.0
34.8
46.5
58.3
8.0
11.9
14.3
20.2
26.5
32.5
31.5 44.4
42.5 56.3
54.5 68.2
Hexagon
Dimensions
'G'
Across Across
Flats Corners
69
69
69
71
77
78
95
96
98
24.0
24.0
30.0
36.0
46.0
55.0
65.0
80.0
95.0
27.7
27.7
34.6
41.6
53.1
63.5
75.1
92.4
109.6
Technical Data
Flameproof EExd and Increased Safety EExe.
II 2 GD
BASEEFA Certificate No. BAS 01 ATEX 2079X.
Suitable for use in Zone 1, Zone 2,
Zone 21 and Zone 22.
Suitable for use in Gas Groups IIA, IIB and IIC.
Smarter products
www.ehawke.com
International
13
ATEX
15.0mm
Armour/Braid
'C'
'B'
'E'
Entry Thread
Deluge
Boot
'D'
Metric
Entry
'G' Approx
Inspectable
Compound
Function
Provides a barrier seal between the individual
insulated cores within the cable and prevent
entry of the products of an explosion into
the cable.
Assembly of the cable gland compresses
and distributes the compound evenly to
effect a barrier seal at the point of entry
into the enclosure.
The compound chamber may be seperated
from the compound to ensure that the
chamber has been effectively filled.
Provides armour clamping, using one
clamping arrangement for all armour/braid
types ' W', 'X' and 'Z'.
Provides an outer deluge seal to prevent
moisture ingress to the cable armour/braid.
Provides a high pullout resistance and low
smoke and fume, zero halogen seal onto
the cables outer sheath.
M20
M20
M20
M25
M32
M40
"
"
"
"
1"
1"
M50
M63
M75
2"
8.9
8.9
11.0
16.2
21.9
26.3
37.1
10.0
10.0
12.5
18.4
24.7
29.7
41.7
6
6
10
21
42
60
80
5.5
9.5
12.5
16.9
22.0
28.0
36.0
46.0
57.0
12.0 0.9/1.25
16.0 0.9/1.25
20.5 0.9/1.25
26.0 1.25/1.6
33.0 1.6/2.0
41.0 1.6/2.0
52.6 1.8/2.5
65.3 1.8/2.5
78.0 1.8/2.5
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/1.0
0/1.0
0/1.0
24.0
24.0
30.0
36.0
46.0
55.0
65.0
27.7
27.7
34.6
41.6
53.1
63.5
75.1
133 80.0
140 95.0
92.4
109.6
133 106.4
133 115.0
132 127.0
123.0
132.8
146.7
87
87
89
100
103
110
133
Larger cable glands available in ICG 653 design as shown below. See page 19
G
H
J
M80
62.8 74.0 140
M90 3" 70.9 83.0 160
M100 4" 80.3 93.0 180
Technical Data
75.0
75.0
88.0
89.5
89.5
104.5
#
#
#
#
#
#
Smarter products
www.ehawke.com
International
14
ATEX
'G' Approx
15.0mm
'B'
'E'
Entry Thread
Inspectable
Compound
'D'
Metric
Entry
Application
Function
75.0
88.0
Technical Data
Flameproof EExd IIC and Increased
Safety EExe II.
II 2 GD
BASEEFA Certificate No. BAS 01 ATEX 2080X.
For sizes Os - F.
BASEEFA Certificate No. BAS 01 ATEX 2297X.
For sizes G - J.
Suitable for use in Zone 1, Zone 2
Zone 21 and Zone 22.
Suitable for use in Gas Groups IIA, IIB and IIC.
Construction and test standards
EN 50014, EN 50018, EN 50019
and EN 50281-1-1.
IEC 60079-0, IEC 60079-1 and IEC 60079-7.
IP66, IP67 and IP68 ingress protection
to IEC 60529, EN 60529 and NEMA 4X.
DTS01 deluge protection certified by ITS.
Operating temperature range
-60C to +80C as standard.
89.5
104.5
#
#
#
#
'G'
Hexagon
Dimensions
Across Across
Flats Corners
65.0
27.7
27.7
34.6
41.6
53.1
63.5
75.1
133 80.0
140 95.0
92.4
109.6
133 106.4
133 115.0
132 127.0
123.0
132.8
146.7
87
87
89
100
103
110
133
24.0
24.0
30.0
36.0
46.0
55.0
Smarter products
www.ehawke.com
International
15
ATEX
15.0mm
'G' Approx
'B'
Male
Entry Thread
Female
Entry Thread
Metric
Entry
Size
Ref.
A
B
C
C2
D
E
Function
Provides a seal onto cables
outer sheath.
Provides female running coupler for
conduit entry.
www.ehawke.com
M50
M63
M75
" M20
" M25
1" M32
1" M40
2" M50
2" M63
3" M75
11.0
13.0
19.0
25.0
31.5
14.3
20.2
26.5
32.5
44.4
42.5 56.3
54.5 68.2
8.5
9.5
15.5
22.0
27.5
39.0
48.5
13.4
15.4
21.2
28.0
34.8
46.5
58.3
Across Across
Flats Corners
34.6
69 30.0
61 36.0
41.6
77 46.0
53.1
79 55.0
63.5
105 65.0
75.1
105 80.0
92.4
107 95.0 109.6
Smarter products
M20
M25
M32
M40
'G'
Hexagon
Dimensions
Technical Data
International
16
ATEX
15.0mm
'G' Approx
Metric
Entry
Female
Entry Thread
Male
Entry Thread
Male Entry
Thread Size
Metric NPT
*
M20
"
M25
"
M32
1"
Female Entry
Thread Size
NPT
*
-
Metric
M20
M25
M32
'G'
69
61
77
Hexagon
Dimensions
Across
Across
Flats
Corners
30.0
34.6
41.6
36.0
46.0
53.1
Function
Maximum No.
of Cores
1.5
2.5
4.0
6.0
10.0
7
4
3
A&B
-
A&B
-
B&C
-
C
B
-
C
B
No.1
1.5
No.1
2.5
No.2
4.0
No.2
6.0
No.3
10.0
Technical Data
Punch Tool
Ordering Example
e.g. Punch Tool Number 1.
Smarter products
www.ehawke.com
International
17
ATEX
15.0mm
Female
Entry Thread
Inspectable
Compound
'D'
Male
Entry Thread
'E'
Metric
Entry
'G' Approx
Function
www.ehawke.com
Max.
Inner
Sheath
No.
Of
Cores
10
21
42
60
80
100
120
140
160
180
Max.
Over
Cores
'G'
Hexagon
Dimensions
Across
Flats
Across
Corners
30.0
36.0
46.0
55.0
65.0
80.0
95.0
106.4
115.0
127.0
34.6
41.6
53.1
63.5
75.1
92.4
109.6
123.0
132.8
146.7
56
58
58
64
64
64
68
70
70
70
Smarter products
A
B
C
C2
D
E
F
G
H
J
Inner Sheath/
Cores
Max.
'D'
'E'
Technical Data
Size
Ref.
International
18
ATEX
501/453
ICG 653 and
153
Oversize, G, H & J
Cable Glands
Flameproof / Increased Safety and
Industrial general purpose
501/453 Flameproof / Increased Safety
15.0mm
'G' Approx
Armour/Braid
'C'
Metric NPT
G
H
J
'B'
'A'
Metric
Entry
Entry Thread
Min.
67.0
M80
M90 3" 67.0
M100 4" 75.0
Max.
Min.
Max.
'G'
Braid
#
#
#
121
121
121
'G' Approx
Inspectable
Compound
Armour/Braid
'C'
'G'
'B'
'D'
'E'
Entry Thread
G
H
J
M80
M90
#
#
#
89.5
89.5
104.5
121
121
121
'A'
Metric
Entry
Entry Thread
'G' Approx
Armour/Braid
'C'
G
H
J
'B'
15.0mm
67.0
M80
M90 3" 67.0
M100 4" 75.0
#
#
#
'G'
121
121
121
Smarter products
www.ehawke.com
International
19
ATEX
15.0mm
'G' Approx
Armour/Braid
'C'
'B'
Entry Thread
'A'
Metric
Entry
Increased Safety
Application
Size
Ref.
Os
O
A
B
C
C2
D
E
Function
Provides armour clamping using one
clamping arrangement for all
armour/braid types 'W', 'X' and 'Z'.
Deluge protection option available.
Provides a high pullout resistance and low
smoke and fume, zero halogen seal onto
the cables outer sheath.
F
G
H
J
Smarter products
www.ehawke.com
Max.
Orientation
1
Orientation
2
5.5
9.5
12.5
16.9
22.0
28.0
36.0
46.0
57.0
12.0
16.0
20.5
26.0
33.0
41.0
52.6
65.3
0.9/1.25
0.9/1.25
0.9/1.25
1.25/1.6
1.6/2.0
1.6/2.0
1.8/2.5
1.8/2.5
1.8/2.5
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/1.0
0/1.0
0/1.0
78.0
Hexagon
Dimensions
'G'
Across Across
Flats Corners
81 24.0
27.7
81
24.0
27.7
34.6
83 30.0
41.6
95 36.0
98 46.0
53.1
63.5
105 55.0
75.1
133 65.0
92.4
126 80.0
134 95.0 109.6
Technical Data
Entry Thread
Inner Sheath
Size
'A'
Max.
Metric NPT
*
M20
8.0
"
M20
"
11.9
14.3
M20 "
M25 "
20.2
M32
26.5
1"
M40 1"
32.5
2"
44.4
M50
M63 2"
56.3
3"
M75
68.2
M80
M90 3"
M100 4"
72.0
80.0
90.0
75.0 89.5
75.0 89.5
88.0 104.5
#
#
#
#
#
#
121
121
121
106.4
123.0
115.0
127.0
132.8
146.7
International
20
15.0mm
'G' Approx
Metric
Entry
'B'
Entry Thread
Function
Provides a high pullout resistance seal
onto the cables outer sheath.
Technical Data
Construction and test standards
EN 50262. BS 6121 Part 1. Type A2.
IP66, IP67 and IP68 ingress protection to
IEC 60529 and EN60529.
DTS01 deluge protection certified by ITS.
Operating temperature range
-60C to +80C as standard.
Entry Thread
Size
Metric NPT
*
M20
"
M20
"
M20
M25
M32
M40
M50
M63
M75
M80
"
"
1"
1"
2"
2"
3"
-
M90 3"
M100 4"
'G'
Hexagon
Dimensions
38
39
38
41
43
42
58
53
56
56
56
56
Across Across
Flats Corners
24.0
27.7
24.0
27.7
34.6
30.0
41.6
36.0
46.0
53.1
55.0
63.5
75.1
65.0
92.4
80.0
95.0 109.6
106.4 123.0
115.0 132.8
127.0 146.7
Cable Gland
Ordering Examples
Cable Gland Type/Size/Thread
e.g. 121/C/M32
121/C/1" NPT
Cable Gland with Alternative Seal (S)
e.g. 121/C/M32/S
121/C/1" NPT/S
Smarter products
www.ehawke.com
International
21
15.0mm
'G' Approx
Metric
Entry
'B'
Entry Thread
Size
Ref.
Os
O
A
B
C
C2
D
E
Function
Provides a high pullout resistant seal onto
the cables outer sheath at two independent
sealing points.
F
G
H
J
Technical Data
Construction and test standards
EN 50262. BS 6121 Part 1. Type A2.
IP66, IP67 and IP68 ingress protection to
IEC 60529 and EN 60529.
DTS01 deluge protection certified by ITS.
Additional deluge protection seal also available.
Operating temperature range
-60C to +80C as standard.
Entry Thread
Size
Metric NPT
*
M20
"
M20
"
M20
M25
M32
M40
M50
M63
M75
M80
"
"
1"
1"
2"
2"
3"
-
M90 3"
M100 4" 75.0
91.6
'G'
Hexagon
Dimensions
67
68
64
69
72
73
100
98
100
100
100
100
Across Across
Flats Corners
24.0
27.7
24.0
27.7
34.6
30.0
41.6
36.0
46.0
53.1
55.0
63.5
75.1
65.0
92.4
80.0
95.0 109.6
106.4 123.0
115.0 132.8
127.0 146.7
Cable Gland
Ordering Examples
Cable Gland Type/Size/Thread
e.g. 123/C/M32
123/C/1" NPT
Cable Gland with Alternative Seal (S)
e.g. 123/C/M32/S
123/C/1" NPT/S
Smarter products
www.ehawke.com
International
22
'G' Approx
Entry Thread
Armour/Braid
'C'
'A'
Metric
Entry
'B'
15.0mm
Function
Provides armour clamping using one
clamping arrangement for all
armour/braid types 'W', 'X' and 'Z'.
Technical Data
Construction and test standards
BS 6121 Part1.
Type BW, BX and BZ.
'G'
Hexagon
Dimensions
46.8
46.8
50.1
54.5
63.7
65.3
68.9
71.5
Across Across
Flats Corners
24.0
27.7
34.6
30.0
41.6
36.0
46.0
53.1
55.0
63.5
75.1
65.0
92.4
80.0
95.0 109.6
Cable Gland
Ordering Examples
Cable Gland Type/Size/Thread
e.g. 150/RAC/C/M32
150/RAC/C/1" NPT
Smarter products
www.ehawke.com
International
23
ATEX
15.0mm
'G' Approx
Armour/Braid
'C'
'B'
Entry Thread
'A'
Metric
Entry
Function
Provides armour clamping using one
clamping arrangement for all
armour/braid types 'W', 'X' and 'Z'.
Deluge protection option available.
Provides a high pullout resistance and low
smoke and fume, zero halogen seal onto
the cables outer sheath.
Technical Data
Size
Ref.
Os
O
A
B
C
C2
D
E
F
Entry Thread
Inner Sheath
Size
'A'
Max.
Metric NPT
*
M20
8.0
"
M20
"
11.9
14.3
M20 "
M25 "
20.2
M32
26.5
1"
M40 1"
32.5
2"
44.4
M50
M63 2"
56.3
3"
M75
68.2
Max.
Orientation
1
Orientation
2
5.5
9.5
12.5
16.9
22.0
28.0
36.0
46.0
57.0
12.0
16.0
20.5
26.0
33.0
41.0
52.6
65.3
0.9/1.25
0.9/1.25
0.9/1.25
1.25/1.6
1.6/2.0
1.6/2.0
1.8/2.5
1.8/2.5
1.8/2.5
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/1.0
0/1.0
0/1.0
78.0
'G'
Hexagon
Dimensions
Across Across
Flats Corners
81 24.0
27.7
81
24.0
27.7
34.6
83 30.0
41.6
95 36.0
98 46.0
53.1
63.5
105 55.0
75.1
133 65.0
92.4
126 80.0
134 95.0 109.6
G
H
J
M80
M90 3"
M100 4"
72.0
80.0
90.0
75.0 89.5
75.0 89.5
88.0 104.5
#
#
#
#
#
#
121
121
121
106.4
123.0
115.0
127.0
132.8
146.7
Smarter products
www.ehawke.com
International
24
15.0mm
Armour/Braid
'C'
Diaphragm
Seal
'B'
'A'
Entry Thread
Metric
Entry
'G' Approx
Function
Provides armour clamping using one
clamping arrangement for all
armour/braid types 'W', 'X' and 'Z'.
Provides a diaphragm seal on the cables
inner sheath. A diaphragm seal will not
damage cable that has 'cold flow'
characteristics.
Deluge protection option available.
Provides a high pullout resistance and
low smoke and fume, zero halogen seal
onto the cables outer sheath.
Technical Data
Construction and test standards
EN 50262. BS 6121 Part1.
Type E1W, E1X and E1Z.
IP66 and IP67 ingress protection to
IEC 60529, EN60529 and NEMA 4X.
Operating temperature range
-60C to +80C as standard.
'G'
Hexagon
Dimensions
Across Across
Flats Corners
81
24.0
27.7
81
24.0
27.7
34.6
30.0
83
41.6
95
36.0
98
46.0
53.1
63.5
105 55.0
75.1
133 65.0
92.4
126 80.0
109.6
134 95.0
Larger cable glands available in 153 design as shown below. See page 19
G
H
J
M80
67.0
M90 3" 67.0
M100 4" 75.0
73.0
77.6
91.6
75.0
75.0
88.0
89.5
89.5
104.5
#
#
#
#
#
#
121
121
121
106.4
123.0
115.0
127.0
132.8
146.7
Cable Gland
Ordering Examples
Cable Gland Type/Size/Thread
e.g. 153/RAC/C/M32
153/RAC/C/1" NPT
Smarter products
www.ehawke.com
International
25
15.0mm
Armour/Braid
'C'
'B'
Entry Thread
'G' Approx
Lead Sheath
Bond
'A'
Metric
Entry
Application
Outdoor or Indoor use.
For use with single wire
armoured 'W', wire braided 'X'
and steel tape armoured 'Z'
cables with a lead inner
sheath.
Function
M20
M20
M25
M32
M40
"
7.5
-
8.5
-
"
" 13.0 16.7
1" 19.0 22.5
1" 25.0 28.5
2" 31.5 40.3
2" 42.0 52.0
3" 54.5 63.8
8.5
11.0
15.5
22.0
27.5
39.0
51.0
10.8
15.4
21.2
28.0
34.8
46.5
58.3
9.5 16.0
12.5 20.5
16.9 26.0
22.0 33.0
28.0 41.0
36.0 52.6
46.0 65.3
57.0 78.0
Technical Data
Construction and test standards
EN 50262. BS 6121 Part1.
Type E2W, E2X and E2Z.
IP66 and IP67 ingress protection to
IEC 60529, EN60529 and NEMA 4X.
Operating temperature range
-60C to +80C as standard.
0.9/1.25
0.9/1.25
1.25/1.6
1.6/2.0
1.6/2.0
1.8/2.5
1.8/2.5
1.8/2.5
0/0.7
0/0.7
0/0.7
0/0.7
0/0.7
0/1.0
0/1.0
0/1.0
#
#
#
#
#
#
81
83
95
98
105
133
126
134
24.0
30.0
36.0
46.0
55.0
65.0
80.0
95.0
121 106.4
121 115.0
121 127.0
27.7
34.6
41.6
53.1
63.5
75.1
92.4
109.6
123.0
132.8
146.7
Cable Gland
Ordering Example
Smarter products
www.ehawke.com
International
26
15.0mm
'G' Approx
'B'
Male
Entry Thread
Female
Entry Thread
Metric
Entry
Function
Provides a seal onto cables
outer sheath.
Provides female running coupler for
conduit entry.
Technical Data
" M20
" M25
1" M32
1" M40
2" M50
2" M63
3" M75
11.0
13.0
19.0
25.0
31.5
14.3
20.2
26.5
32.5
44.4
42.5 56.3
54.5 68.2
8.5
9.5
15.5
22.0
27.5
39.0
48.5
13.4
15.4
21.2
28.0
34.8
46.5
58.3
'G'
Hexagon
Dimensions
69
61
77
79
105
105
107
Across Across
Flats Corners
34.6
30.0
41.6
36.0
46.0
53.1
55.0
63.5
75.1
65.0
92.4
80.0
95.0 109.6
Cable Gland
Ordering Examples
Smarter products
www.ehawke.com
International
27
'G' Approx
Armor Stop
Deluge
Boot
Armor Grounding
Device
'B'
'E'
Entry Thread
Nickel Plated
Hub
Function
Provides superior 360 armor
grounding device.
Provides an outer deluge seal to prevent
moisture ingress to the cable armor.
Provides a high pullout resistance and low
smoke and fume, zero halogen seal onto the
cables outer sheath.
Entry
Cable Acceptance Details
Hexagon
Size Thread Armor Sheath Outer Sheath
Dimensions
'G'
'E'
'B'
Ref. Size
Across Across
NPT
Max.
Min.
Max.
Min.
Flats Corners
*
"
A
0.41" 0.64"
0.49" 0.81" 3.59" 1.18" 1.36"
B
"
0.49" 0.93"
0.66" 1.02" 4.02" 1.42" 1.64"
C
1"
0.85" 1.23"
0.87" 1.30" 4.25" 1.81" 2.09"
1.17"
1.10" 1.61" 4.49" 2.17" 2.50"
1.59"
C2
1"
2"
1.37" 1.96"
1.34" 2.07" 5.39" 2.56" 2.96"
D
1.76" 2.55"
1.81" 2.57" 5.39" 3.15" 3.64"
E
2"
F
2.29" 2.98"
2.24" 3.07" 5.67" 3.74" 4.31"
3"
* Metric entry threads are also available. Please ask for details.
Assembly instruction data sheet No. A.I. 315. For sizes A to F.
Assembly instruction data sheet No. A.I. 342. For size H.
Alternative thread sizes available. See page 38
Accessories includinglocknuts, sealing washers, shakeproof washers, shrouds,
adaptors and reducers available. See pages 33 - 37
Technical Data
Cable Gland
Ordering Example
Smarter products
www.ehawke.com
International
28
'G' Approx
Compound
Armor Grounding
Device
'B'
Entry Thread
'E'
Deluge
Boot
'D'
Nickel Plated
Hub
Explosion Proof
Application
Outdoor or Indoor use.
For use with continuous corrugated aluminum,
interlocked aluminum and interlocked steel,
Metal Clad (MC) and Teck type cables.
See technical section of catalogue for
installation rules and regulations.
Function
Provides superior 360 armor
grounding device.
Provides a barrier seal between the individual
insulated cores within the cable and prevent
entry of the products of an explosion into
the cable.
Assembly of the cable gland compresses
and distributes the compound evenly to
effect a barrier seal at the point of entry
into the enclosure.
Provides an outer deluge seal to prevent
moisture ingress to the cable armor.
Provides a high pullout resistance and low
smoke and fume, zero halogen seal onto
the cables outer sheath.
Entry
Thread
Size
Size
Ref.
NPT
*
A
B
C
C2
D
E
F
"
0.43"
" 0.64"
1" 0.86"
1" 1.04"
2" 1.46"
2" 1.88"
2.32"
3"
0.41"
0.49"
0.85"
1.17"
1.37"
1.76"
2.29"
0.64" 10
0.93" 21
1.23" 42
1.59" 60
1.96" 80
2.55" 100
2.98" 120
'G'
Hexagon
Dimensions
Across Across
Flats Corners
1.18"
1.42"
1.81"
2.17"
2.56"
3.15"
3.74"
1.36"
1.64"
2.09"
2.50"
2.96"
3.64"
4.31"
Cable Gland
Ordering Example
Technical Data
Smarter products
www.ehawke.com
International
29
'G' Approx
Compound
'B'
'E'
Entry Thread
'D'
Explosion Proof
Application
Function
Entry
Thread
Size
Size
Ref.
NPT
*
Os
O
A
B
C
C2
D
E
F
"
"
"
"
1"
1"
2"
2"
3"
'G'
3.19"
3.19"
3.27"
3.43"
3.62"
3.90"
4.45"
4.61"
4.72"
Over
Cores
Sheath
Cores
0.35"
0.35"
0.43"
0.64"
0.86"
1.04"
1.46"
1.88"
2.32"
0.39"
0.39"
0.49"
0.72"
0.97"
1.16"
1.64"
2.11"
2.61"
6
6
10
21
42
60
80
100
120
0.22"
0.37"
0.49"
0.66"
0.87"
1.10"
1.34"
1.81"
2.24"
0.47"
0.63"
0.81"
1.02"
1.30"
1.61"
2.07"
2.57"
3.07"
Hexagon
Dimensions
Across Across
Flats Corners
0.94"
0.94"
1.18"
1.42"
1.81"
2.17"
2.56"
3.15"
3.74"
1.09"
1.09"
1.36"
1.64"
2.09"
2.50"
2.96"
3.64"
4.31"
* Metric entry threads are also available. Please ask for details.
Two part sealing compound and assembly instructions are supplied
with the cable gland.
Assembly instruction data sheet No. A.I. 316. For sizes Os to F.
Assembly instruction data sheet No. A.I. 337. For size H.
Alternative thread sizes available. See page 38
Accessories such as locknuts, sealing washers, shakeproof washers, shrouds,
adaptors and reducers available. See pages 33 - 37
Cable Gland
Ordering Example
Technical Data
Smarter products
www.ehawke.com
International
30
'G' Approx
Armor/Braid
'C'
Compound
'B'
'D'
Entry Thread
'E'
Nickel Plated
Hub
Explosion Proof
Application
Outdoor or indoor use.
For use with armored marine shipboard
jacketed or non-jacketed cable.
See technical section of catalogue for
installation rules and regulations.
Hexagon
Dimensions
'G'
Across Across
Flats Corners
Sheath
Function
Provides a barrier seal between the
individual insulated cores within the
cable and prevent entry of the products
of an explosion into the cable.
Assembly of the cable gland compresses
and distributes the compound evenly to
effect a barrier seal at the point of entry
into the enclosure.
Deluge protection option available.
Provides a high pullout resistance and low
smoke and fume, zero halogen seal onto
the cables outer sheath.
Technical Data
Os
O
A
B
C
C2
D
E
F
0.22"
0.37"
0.49"
0.66"
0.87"
1.10"
1.42"
1.81"
2.24"
0.47"
0.63"
0.81"
1.02"
1.30"
1.61"
2.07"
2.57"
3.07"
0.008"/0.013"
0.008"/0.013"
0.008"/0.013"
0.008"/0.013"
0.008"/0.013"
0.008"/0.013"
0.008"/0.013"
0.008"/0.013"
0.008"/0.013"
3.19"
3.19"
3.27"
3.43"
3.62"
3.90"
4.45"
4.61"
4.72"
0.94"
0.94"
1.18"
1.42"
1.81"
2.17"
2.56"
3.15"
3.74"
1.09"
1.09"
1.36"
1.64"
2.09"
2.50"
2.96"
3.64"
4.31"
Cable Gland
Ordering Example
Smarter products
www.ehawke.com
International
31
'G' Approx
Compound
Armor/Braid
'C'
'B'
'D'
Entry Thread
'E'
Nickel Plated
Hub
Explosion Proof
Application
Technical Data
'G'
3.19"
3.19"
3.27"
3.43"
3.62"
3.90"
4.45"
4.61"
4.72"
Hexagon
Dimensions
Across Across
Flats Corners
0.94" 1.09"
0.94" 1.09"
1.18" 1.36"
1.42" 1.64"
1.81" 2.09"
2.17" 2.50"
2.56" 2.96"
3.15" 3.64"
3.74" 4.31"
Cable Gland
Ordering Example
Smarter products
www.ehawke.com
International
32
Sealing
Washers
Metric
NPT * #
Size
Cable
Gland
Cable
Gland
Ref.
Size 'V'
Size 'V'
'Pips'
O
A
B
C
C2
D
E
F
G
H
J
'V'
Application
SEALING WASHER
SELECTION TABLE
M20
M20
M25
M32
M40
M50
M63
M75
M80
M90
M100
"
"
"
1"
1"
2"
2"
3"
3"
4"
'U'
Function
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
Ordering Examples
'V'
Serrated Washer
SERRATED WASHER
SELECTION TABLE
'U'
Metric
NPT *
Size
Ref. Cable Gland Cable Gland
Size 'V'
Size 'V'
O
A
B
C
C2
D
E
F
'V'
Application
Outdoor or Indoor use.
For use on cable gland entry threads.
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
Ordering Examples
www.ehawke.com
"
"
"
1"
1"
2"
2"
3"
'U'
Function
Smarter products
M20
M20
M25
M32
M40
M50
M63
M75
Serrated Washer/Size/Thread
e.g. Serrated Washer/B/M25
Serrated Waher/B/" NPT
International
33
Earth Tags
and
Locknuts
Earth Tags
'Z'
'X'
'W'
'Y'
'
'U
'V'
Function
'Y'
'W'
'X'
'Z'
13.8
18.6
22.2
25.4
32.6
41.4
47.6
57.5
62.5
67.5
7.0
10.5
12.2
13.6
13.5
13.5
13.5
14.0
14.0
14.0
39.6
45.5
52.0
59.6
78.9
87.6
93.7
128.0
128.0
128.0
33.1
36.5
40.9
44.2
58.1
66.8
72.9
104.0
104.0
104.0
1.6
1.6
1.6
1.6
1.6
1.6
1.6
3.0
3.0
3.0
Ordering Example
Earth Tag /Size/Thread
'Y
'
'X'
'Z'
Function
Smarter products
www.ehawke.com
'V'
NPT
Across Across
Flats Corners
'X'
'Y'
'Z'
30.0
36.0
46.0
55.0
65.0
80.0
95.0
127.0
127.0
139.7
33.6
40.3
51.5
61.6
72.8
89.6
107.0
143.0
143.0
158.0
4.7
6.4
6.4
6.4
6.4
6.4
6.4
9.0
9.0
9.0
Ordering Example
Locknut /Size/Thread
e.g. Locknut/B/M25
International
34
Cable Gland
Accessories
PVC Shrouds
PVC SHROUD
TABLE
LSFZH SHROUD
TABLE
Size Ref.
Size Ref.
O/Os
A
B
C
C2
D
E
F
G
H
J
O/Os
A
B
C
C2
D
E
F
LSFZH Shrouds
Ordering Examples
Shroud Type/Size
Application
Insulated Adaptor
SELECTION TABLE
Across Flats
Female
Thread
'Z'
Male
Entry Thread
Male Thread
15.0mm
Metric Entry
50mm
Application
Technical Data
Smarter products
www.ehawke.com
Size
Ref.
Thread Type
Female
Thread
'Z'
Bore
Hexagon
Dimensions
Across Across
Metric NPT
Metric
Flats Corners
*
34.6
A
M20
"
14.3 30.0
M20
41.6
M25
20.2 36.0
B
"
M25
M32
53.1
M32
C
1"
26.5 46.0
M40
M40
C2
1"
63.5
32.5 55.0
2"
75.1
D
44.5 65.0
M50
M50
92.4
E
M63 2"
56.3 80.0
M63
3"
M75
68.3 95.0 109.6
F
M75
All dimensions in millimetres (except*).
Exd IIC.
Suitable for use in Zone 1 and Zone 2.
Suitable for use in Gas Groups IIA, IIB and IIC.
378 Certification and Approval
BASEEFA Certificate No. Ex 813167U.
EExe II.
Suitable for use in Zone 1 and Zone 2.
178 Industrial
Ordering Example
International
35
ATEX
Stopping
Plugs
Type 475 and 477 Flameproof
'V'
Function
Thread Size
Metric
NPT
x 1.5p
M20
"
M25
"
M32
1"
1"
M40
M50
2"
M63
2"
M75
3"
Hex. Key
Across Flats
Size 'V'
10.0
10.0
14.0
14.0
17.0
17.0
19.0
'V'
Function
Hex. Key
Across Flats
Size 'V'
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
Hex. Key
Metric
x 1.5p
Across Flats
Size 'V'
10.1
10.1
M20
M25
'V'
Function
Smarter products
www.ehawke.com
Ingress Protection
To meet with IP66 and IP67, the stopping plugs must be
fitted perpendicular to the equipment face in a suitably
sized threaded or plain hole and the equipment face must
be smooth. Plain holes must be no larger than 0.7mm
above the major diameter of the stopping plug thread and
the plug must be held in place with a locknut.
An optional locking washer may also be fitted.
To the best of our knowledge the information
contained in this brochure, is accurate at the
time of going to print and the company reserves
the right to improve or modify any product
illustrated without notification. The company is
unable to accept liability for any inaccuracies,
errors or omissions that may exist. It is the
customer's responsibility to ensure that the
product is suitable for their application.
Technical Data
Flameproof EExd IIC
II 2 GD IP66.
BASEEFA Certificate No. BAS 01 ATEX 2244X.
Technical Data
Ingress Protection
To meet with IP66 and IP67, the stopping plugs must be fitted
perpendicular to the equipment face in a suitably sized threaded
or plain hole and the equipment face must be smooth. Plain
holes must be no larger than 0.7mm above the major diameter
of the stopping plug thread and the plug must be held in place
with a locknut. An optional locking washer may also be fitted.
Technical Data
Increased Safety EExe II
II 2 GD IP66.
BASEEFA Certificate No. BAS 01 ATEX 2104U.
International
36
ATEX
Adaptors and
Reducers
Type 476 & 376
Adaptor
Reducer
Adaptor
Male Thread
Reducer
Metric
NPT
"
"
1"
1" 1"
2"
2"
3"
M16
M20
Metric
M25
M32
M40
M50
Female Thread
M63
M75
"
"
NPT *
1"
1"
1"
2"
2"
3"
All Metric entry threads are 1.5mm pitch medium fit.
+ Alternative entry thread types and sizes available.
Application/Function
Smarter products
www.ehawke.com
Technical Data
ATEX Adaptor/Reducer
Ordering Examples
International
37
Cable Gland
Variations
and Options
NPT Threads
Metric
NPT
O
A
B
C
C2
D
E
F
M16
M16
-
"
1"
1"
1"
1"
2"
2"
GLAND TYPE
Diaphragm Inner Seal
Size
Compression Inner Seal
Ref.
No Innner Seal
D
E
F
42.3
54.3
65.3
N/A
N/A
65.3
Ordering Example
Orientation 1
Orientation 2
0.8 - 1.0
0.8 - 1.0
0.9 - 1.25
1.2 - 1.6
1.2 - 1.6
1.45 - 1.8
1.45 - 1.8
1.45 - 1.8
0.4 - 0.8
0.4 - 0.8
0.5 - 0.9
0.6 - 1.2
0.6 - 1.2
1.0 - 1.45
1.0 - 1.45
1.0 - 1.45
Smarter products
www.ehawke.com
International
38
Technical Data
The intent of this section of the catalogue is to identify important features that may be useful in the selection and installation
of explosion protected electrical equipment.
There are numerous different regulations, codes, guidelines and standards for the design, installation and maintenance of
electrical and non-electrical systems for use in potentially explosive atmospheres. The type of operational facility, geographic
location, operator practice, local and national legislation, authority having jurisdiction etc. will determine many of the design and
installation rules permitted. A fixed or floating petroleum facility located offshore, for example, would not be designed or
classified in the same manner as an onshore petrochemical facility.
1.0
2.0
3.0
Area Classification
Area classification is the division of a facility into three-dimensional hazardous areas and non-hazardous areas
and the sub-division of the hazardous area into 'Zones'.
Hazardous areas may be sub-divided into three Zones as follows: -
An area in which an explosive atmosphere is constantly present, or present for long periods.
(Rough Guide: More than 1,000 hours / year)
Zone 1
Zone 2
An area in which an explosive atmosphere is not likely to occur in normal operation and if it
occurs, it will exist only for a short time.
(Rough Guide: Less than 10 hours / year)
Smarter products
www.ehawke.com
39
Technical Data
Combustible Dusts
Zone 20
Zone 21
Zone 22
An area in which combustible dust, as a cloud, is present continuously or frequently, during normal
operation, in sufficient quantity to be capable of producing an explosive concentration of
combustible dust in a mixture with air
An area, in which combustible dust, as a cloud, is occasionally present during normal operation, in a
sufficient quantity to be capable of producing an explosive concentration of combustible dust in a
mixture with air.
An area, in which combustible dust, as a cloud, may occur infrequently and persist for only a short
period, or in which accumulations of layers of combustible dust may give rise to an explosive
concentration of combustible dust in mixture with air.
For further information on the classification of hazardous areas, see: IEC 60079-10
IEC 61241-3
(Proposed Change
to IEC 61241-10)
IEC 60079-10
PR EN 50281-3
Institute of Petroleum - Model Code of Safe Practice in the Petroleum Industry, Part 15: Area Classification
Code for Petroleum Installations, IP 15
3.2
Classification Society
A Classification Society may also enforce requirements for the design and installation of facilities. These
requirements, which are in addition to statutory requirements, may influence the design and installation of the
electrical systems. Classification Societies include ABS, DNV and Lloyds Register.
3.3
Smarter products
www.ehawke.com
40
Technical Data
3.4
3.5
Temperature class of
electrical apparatus
T1
450C
>450C
T2
300C
>300C
T3
200C
>200C
T4
135C
>135C
T5
100C
>100C
T6
85C
>85C
If the marking of the electrical apparatus does not include an ambient temperature range, the apparatus is only for use
within an ambient temperature range from -20C to +40C.
For further information regarding data for flammable gases and vapours, see PD IEC 60079-20.
Smarter products
www.ehawke.com
41
Technical Data
3.6
3.7
IIB or IIC
IIC
3.8
IEC
EN 50014
General Requirements
IEC 60079-0
General Requirements
EN 50015
IEC 60079-6
EN 50016
Pressurisation 'p'
IEC 60079-2
Pressurisation 'p'
EN 50017
IEC 60079-5
EN 50018
IEC 60079-1
EN 50019
IEC 60079-7
EN 50020
IEC 60079-11
EN 50021
IEC 60079-15
EN 50028
Encapsulation 'm'
IEC 60079-18
Encapsulation 'm'
Smarter products
www.ehawke.com
42
Technical Data
3.9
4.0
Smarter products
www.ehawke.com
43
Technical Data
The Directive classifies equipment into eight categories depending on the equipment's area of use: -
4.1
Category M1
equipment intended for mining use and is required to remain functional in the presence of an
explosive atmosphere.
Category M2
equipment intended for mining use but is intended to be de-energised in the event of an
explosive atmosphere.
Category 1G
Category 2G
Category 3G
Category 1D
Category 2D
Category 2D
Smarter products
www.ehawke.com
44
Technical Data
5.1
The IEC and CELELEC installation standards, IEC 60079-14 and EN 60079-14 address "cold flow" in Clause 9.1.3.
Smarter products
www.ehawke.com
45
Technical Data
5.2
Hawke
ICG 653/UNIV
Cable Gland
The first and most important criterion is that the thermoplastic, thermosetting or elastomeric cable is
substantially compact and circular, has extruded bedding and the fillers, if any, are non-hygroscopic. Should the
cable not meet with any of these criteria, a barrier cable gland, e.g. a Hawke ICG 653 Universal cable gland
that incorporates compound filled seals around the cables individual conductors or other equivalent sealing
arrangements must be used. The reason being is that the products of an explosion within the equipment may
enter into the cable through its voids or interstices and cause ignition of the potentially explosive atmosphere
surrounding the cable or inside the equipment the cable is connected to.
Cable glands may also be designed, tested and certified for use with a particular cable construction type e.g.
for use with trace heating flat form cable types. The cable gland approval certificates, if applicable, will refer to
the appropriate cable type description.
Cable glands may also be designed for use with a particular cable construction and be tested and certified
with the equipment. Reference to these cable gland types will be given in the equipment approval certification
documents, if applicable.
The IEC and CENELEC design, selection and installation standards, IEC 60079-14 and EN 60079-14 offers
guidance on the selection of flameproof cable gland types.
Where cables enter flameproof equipment directly, they should comply with the following: -
a)
Application:
an enclosure in Zone 1 or 2, Group IIA or IIB that contains terminals only or an enclosure that does
not contain equipment with an ignition source such as arcing or sparking devices (e.g. relays, contactors,
etc) or equipment that in normal operation will not cause temperatures that can cause ignition.
b)
Application:
an enclosure in Zone 1 or 2, Group IIC with an enclosure volume greater than 2-litres, that contains
terminals only or an enclosure that does not contain equipment with an ignition source such as arcing
or sparking devices (e.g. relays, contactors, etc) or equipment that in normal operation will not cause
temperatures that can cause ignition.
Smarter products
www.ehawke.com
46
Technical Data
c)
Application:
an enclosure that contains equipment with an ignition source such as arcing or sparking devices (e.g.
relays, contactors, etc) or equipment that in normal operation will cause temperatures that can cause
ignition in Zone 2, gas group IIA or IIB
d)
Application:
an enclosure that contains equipment with an ignition source such as arcing or sparking devices (e.g.
relays, contactors, etc) or equipment that in normal operation will cause temperatures that can cause
ignition in Zone 1, gas group IIA or IIB and an enclosure volume less than 2-litres.
e)
Application:
an enclosure that contains equipment with an ignition source such as arcing or sparking devices (e.g.
relays, contactors, etc) or equipment that in normal operation will cause temperatures that can cause
ignition in Zone 1, gas group IIA or IIB and an enclosure volume greater than 2-litres.
f)
Application:
an enclosure that contains equipment with an ignition source such as arcing or sparking devices (e.g.
relays, contactors, etc) or equipment that in normal operation will cause temperatures that can cause
ignition in Zone 1 or 2, gas group IIC.
Exceptions:
Cable gland types specified in the equipment documentation and incorporating sealing devices appropriate
to the cables used.
Cable gland types tested and certified with a particular cable construction type
Smarter products
www.ehawke.com
47
Technical Data
6.0
Manufacturers
name or registered
trademark
HAWKE
Manufacturers type
identification, e.g.
catalogue number
Year of
certification
BAS
01
Ex
2070
Certificate
number
II
T6 Tamb -60+80 oC
The group of
the electrical
apparatus
U
Name or mark of
certificate testing
station
6.1
Equipment certificate
issued by an EEC
approved body
501/453/UNIV/B/M25
Smarter products
www.ehawke.com
48
Technical Data
6.2
Additional CE Marking
The CE conformity marking must consist of the initials
the notified body responsible for production control.
Example:
0600
7.0
CE Marking
The CE Marking is intended to facilitate the free movement of products within the European Union. By affixing CE
marking to products, the manufacturer is making a legal declaration that the product meets with the appropriate
requirements of all relevant European Directives. CE marking only applies to products within the scope of the
Directives. It should not be applied to products if they are outside the scope of the Directives.
7.1
7.2
8.0
Smarter products
www.ehawke.com
49
Technical Data
9.0
Second Number
First Number
Non-protected
Protected against
vertically falling
water drops
Protected against
vertically falling
water drops when
enclosure tilted up
to 15
Protected against
solid foreign
objects of 2.5mm
diameter and
greater
Protected against
spraying water
Protected against
solid foreign
objects of 1.0mm
diameter and
greater
Protected against
splashing water
Dust-protected
Protected against
water jets
Dust-tight
No ingress of dust
Protected against
powered water
jets
Protected against
the effects of
temporary
immersion in water
Protected against
the effects of
continuous
immersion in water
Non-protected
Protected against
objects of 50mm
diameter and
greater
Protected against
solid foreign
objects of 12.5mm
diameter and
greater
1
50
2
12.5
15cm min.
15M
Smarter products
www.ehawke.com
50
Technical Data
7.0 CE Marking
The protection of the enclosure and the equipment inside against external influences or conditions, such as:
mechanical impacts, corrosion, corrosive solvents, solar radiation, icing moisture (e.g. produced by condensation), and
explosive atmospheres, are matters that should be dealt with by the relevant product Standard.
There are additional and supplementary optional letters to the above coding; these designators are A, B, C & D and H,
M, S & W, and further information can be found in the relevant Standard(s).
9.1
Testing includes: Energising the equipment (where appropriate) for 60 minutes prior to the deluge test, then interrupting
the electrical power at the start of the deluge test and resuming after 60 minutes until the completion of
the deluge test.
Carrying out insulation resistance testing before and after pre-conditioning and after the deluge test,
where applicable.
Carrying out pre-conditioning by exposure to vibration and thermal ageing at 90% relative humidity and
at a temperature 20k above the equipments maximum service temperature and/or at least 80C of any
appropriate seals.
Carrying out deluge test using a deluge chamber fitted with deluge nozzles that apply a salt water
solution deluge pressure within the range of 3.5 bar to 4.5 bar at a water temperature in the range of
5C to 10C for 3-hours.
Area Classification
Area classification is the division of a facility into a two or three-dimensional hazardous location, a nonhazardous location and the sub-division of the hazardous location into 'Divisions' or 'Zones'.
Hazardous (classified) locations may be sub-divided as follows: -
Smarter products
www.ehawke.com
51
Technical Data
In the United States of America, hazardous (classified) locations are sub-divided into three Zones or two
Divisions, as follows: -
Division 2:
Where ignitable concentrations of flammable
gases, vapors or liquids are not likely to exist
under normal operating conditions
Zone 2:
Where ignitable concentrations of flammable
gases, vapors or liquids are not likely to exist
under normal operating conditions.
Division 1:
Where ignitable concentrations of flammable
gases, vapors or liquids can exist all of the time or
some time under normal operating conditions.
Division 2:
Where ignitable concentrations of combustible
dusts are not likely to exist under normal
operating conditions
Smarter products
www.ehawke.com
52
Technical Data
11.2
NEC, NFPA 70
NFPA 30
NFPA 497
NFPA 499
ANSI/API RP500
ANSI/API RP 505
Intrinsically safe equipment listed for use in Class I, Division 1, locations for the same gas or a permitted by
Section 505-7(d) of the NEC, and with suitable temperature rating is permitted in Class I, Zone 0 locations.
Equipment approved for use in Class I, Division 1 or listed for use in Class I, Zone 0 locations for the same
gas, or as permitted by Section 505-7(d) of the NEC, and with a suitable temperature rating is permitted in
Class I, Zone 1 locations.
Equipment approved for use in Class I, Division 1 or Division 2 locations for the same gas, or as permitted by
Section 505-7(d) of the NEC, and with a suitable temperature rating is permitted in Class I, Zone 2 locations.
Equipment listed as classified for use in Class I locations is not necessarily acceptable for Class II locations as
it may not be dust-tight or operate at a safe temperature with a dust covering.
Smarter products
www.ehawke.com
53
Technical Data
11.3
Maximun surface
temperature of
electrical apparatus
Ignition temperature
of gas or vapour
T1
450C
>450C
T2
300C
>300C
T2A
280C
>280C
T2B
260C
>260C
T2C
230C
>230C
T2D
215C
>215C
T3
200C
>200C
T3A
180C
>180C
T3B
165C
>165C
T3C
160C
>160C
T4
135C
>135C
T4A
120C
>120C
T5
100C
>100C
T6
85C
>85C
Temperature class of
electrical apparatus
Low ambient conditions require special consideration. Explosion proof of dust ignition proof equipment may
not be suitable for use at temperatures lower than -25C (-13F) unless they are identified for low
temperature service. Unless the equipment is marked otherwise, it is for use only in an ambient temperature
range of -25C (-13F) to +40C (+104F).
Equipment that is approved for Class I and Class II should be marked with the maximum safe operating
temperature.
For information regarding data for flammable gases and vapors, see NFPA 497 and NFPA 325.
11.4
11.5
Smarter products
www.ehawke.com
54
Technical Data
11.6
Dust Group
E
(typical atmospheres containing
combustible metal dusts)
F
(typical atmospheres containing
coal dusts)
G
(typical atmospheres containing
grain dusts)
Non-incendive Electrical Equipment for use in Class I and II, Division 2 and Class
III, Divisions 1 and 2 Hazardous (Classified) Locations.
ANSI / UL 913
Intrinsically Safe Apparatus and Associated Apparatus for use in Class I, II and III,
Division 1, Hazardous Locations.
ANSI / UL 698
ANSI / UL 2225
UL 1604
Electrical Equipment for use in Class I and II, Division 2 and Class III Hazardous
(Classified) Locations.
ANSI / UL 2279
ISA S12.0.01
ISA S12.22.01
ISA S12.16.01
Smarter products
www.ehawke.com
55
Technical Data
11.7
API RP 14FZ
12.1
Type MC cable, listed for use, with a gas / vapor tight continuous corrugated aluminum sheath, an overall
jacket of suitable polymeric material, separate grounding conductors, in accordance with Sections 250122 and 501-4 of the NEC, and provided with termination fittings listed for he application, e.g. Hawke
type 711 cable gland.
Type ITC cable, listed for use with a gas / vapor tight continuous aluminum sheath, an overall jacket of
suitable polymeric material in accordance with Section 501-4 of the NEC and provided with termination
fittings listed for the application, e.g. Hawke type 711 cable gland.
Threaded rigid metal conduit, threaded steel intermediate metal conduit, or type MI cable with
termination fittings approved for the location and in accordance with Section 501-4 of the NEC.
All boxes, fittings and joints must be explosion-proof.
In Class I, Division 2 locations, the NEC permits the following wiring methods: Type MC, MV, ITC, PLTC, TC or MI cable with approved termination fittings in accordance with Section
501-4 of the NEC.
Threaded rigid metal conduit, threaded steel intermediate metal conduit.
Non-incendive field wiring using any of the methods suitable for wiring in ordinary locations in
accordance with Section 501-4 of the NEC.
Boxes, fittings and joints need not be explosion-proof except as required by the NEC code.
Smarter products
www.ehawke.com
56
Technical Data
12.2
12.3
12.4
Metal-clad (type MC) cables that are permitted for use, must have a continuous corrugated gas tight,
vapor-tight, and water-tight sheath of aluminum or other suitable metal that is close fitting around the
conductors and with fillers. The MC cable must have an overall jacket of an impervious PVC or
thermoset material and be certified or listed to UL 1569.
For information on other wiring methods permitted and further information, refer to Subpart 111-60 of the
USCG 46 CFR.
Each cable entry into explosion-protected equipment must be made with an appropriate fitting or cable gland
that maintains the integrity of the equipment.
12.4.1 Cables with multi-conductors that enter explosion-proof enclosures, must be sealed with an appropriate
fitting, e.g. barrier type cable gland, after removing the cables jacket and all other coverings so that the sealing
compound surrounds each individual insulated conductor. Cables with twisted pairs and shielded cables
require the removal of the shielded material or separation of the twisted pairs unless the fitting, e.g. barrier
type cable gland, is an approved means which minimises the entrance of gases or vapours and prevents
propagation of flame into the cable core. If the fitting complies with this requirement, there will be
information provided in the fittings installation instructions detailing the means to achieve the seal. Additional
testing may be required on the fitting, and the style and type of cable to show compliance with the sealing
requirements.
Smarter products
www.ehawke.com
57
Technical Data
The equipment grounding path should be carefully considered when using Shipboard Cables or type TC
cables, as these may not inherently provide a grounding means. The armor of Shipboard Cables should be
grounded but can not be used as the grounding conductor. An appropriate sized grounding conductor should
be included in each cable.
12.5
HawkeType 710
Cable Gland
Additional wiring methods acceptable for Division 2 include type PLTC, ITC, TC and MV cables. It is
recommended that an overall PVC or other suitable polymeric material jacket is included for these cable
types.
For additional information, refer to Clause 6.4.2.3 of API RP14F.
In Division I locations, all electrical equipment (except intrinsically safe systems and equipment inside purged
enclosures) should be explosion-proof.
In Division 2 locations, the equipment does not need to be explosion-proof, except where necessary to
maintain the integrity of the installation.
Further information on the use of equipment is given in Clause 6.4.7 of API RP14F.
An NRTL approved cable sealing fitting, e.g. barrier type cable gland complying with UL 2225, must be fitted
onto cables where they enter explosion-proof enclosures.
Smarter products
www.ehawke.com
58
Technical Data
For fitting requirements of cables with multi-conductors, twisted pairs or shielded conductors into explosion
proof equipment. See clause 12.4.1.
Class 1, Zones 0, 1 and 2
The API RP 14 FZ, Recommended Practice for the design and installation of electrical systems for fixed and
floating offshore petroleum facilities for unclassified and Class I, Zone 0, Zone 1 and Zone 2 locations,
recommends the following wiring methods for hazardous (classified) locations.
Class 1, Zone 1
Type MC-HL metal clad cables as defined in UL 2225.
Armored marine shipboard cable with an overall impervious sheath over the armor, constructed in
accordance with UL 1309, and listed as "Shipboard Cable Marine" by a National Recognised Testing
Laboratory (NRTL). This wiring method is a departure from the NEC.
Type ITC cable that is NRTL - listed for use in Class 1, Division 1 locations with a gas / vapor tight
continuous corrugated aluminum sheath and with an overall PVC or other suitable polymeric jacket.
Threaded rigid copper-free aluminum conduit.
Threaded rigid steel, hot dipped galvanized conduit, coated with PVC, or other suitable material, and with
the interior protected by an additional means.
Non-armored marine shipboard cable, with an overall impervious jacket in accordance with UL 1309 and
listed as "Shipboard Cable Marine" by a NRTL. This wiring method is a departure from the NEC.
For further information and other wiring methods acceptable for Zone 1, refer to Clause 6.4.2.2 of the API
RP14FZ.
For fitting requirements of cables with multi-conductors, twisted pairs or shielded conductors into explosion
proof equipment. See clause 12.4.1.
Class 1, Zone 2
Wiring methods as recommended for use in Zone 1.
Type MC cable with a gas / vapor tight continuous corrugated aluminum sheath, an overall PVC or other
suitable polymeric jacket, and grounding conductors in accordance with NEC 250-122.
Non-armored marine shipboard cable, with an overall impervious jacket in accordance with UL 1309 and
listed as "Shipboard Cable Marine" by a NRTL. This wiring method is a departure from the NEC.
Additional wiring methods acceptable for Zone 2 include type PLTC, ITC, TC and MV cables. It is
recommended that an overall PVC or other suitable polymeric material jacket is included for these cable
types.
For additional information, refer to Clause 6.4.2.3 of API RP14FZ.
Further information on the use of equipment is given in Clause 6.4.7 of API RP14FZ.
An NRTL approved cable sealing fitting, e.g. barrier type cable gland complying with UL 2225, must be fitted
onto cables where they enter explosion-proof enclosures.
For fitting requirements of cables with multi-conductors, twisted pairs or shielded conductors into explosion
proof equipment. See clause 12.4.1.
Smarter products
www.ehawke.com
59
Technical Data
Where cables enter equipment which is permitted for use in Zone 2 or unclassified areas and that is not
explosion-proof, a suitable cable fitting e.g. cable gland design, need not be explosion-proof, except when
necessary to maintain the integrity of the enclosure and as required by the Recommended Practice.
In unclassified and Zone 2 locations, when the metallic sheath is approved as a grounding conductor, the
continuous metal sheath of the MC cable or the combined metallic sheath and grounding conductors may be
used as the grounding conductor when used with termination fittings that are NRTL-listed to UL 514B.
12.6
Class I, Zone 1
Area classification
12.7
AEx
IIC
Type(s) of protection
T6
Temperature
classification
Smarter products
www.ehawke.com
60
NEMA
Enclosure
Type Number
Technical Data
12.8
Application
For indoor use to provide a degree of protection (personnel against incidental contact with the
enclosed equipment) against falling dirt.
For indoor use to provide a degree of protection (personnel against incidental contact with the
enclosed equipment) against falling dirt, and to provide a degree of protection against dripping and
light splashing of liquids.
3
3R
3S
4X
6P
12
12K
13
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt, rain, sleet, snow, and windblown dust; and
that will be undamaged by the external formation of ice on the enclosure.
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt, rain, sleet, and snow; and that will be
undamaged by the external formation of ice on the enclosure.
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt, rain, sleet, snow, and windblown dust; and in
which the external mechanism(s) remain operable when ice laden.
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt, rain, sleet, snow, windblown dust, splashing
water, and hose-directed water; and that will be undamaged by the external formation of ice on the
enclosure.
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt, rain, sleet, snow, windblown dust, splashing
water, hose-directed water, and corrosion; and that will be undamaged by the external formation of
ice on the enclosure.
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt; against settling airborne dust, lint, fibres, and
flyings; and to provide a degree of protection against dripping and light splashing of liquids.
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt; against hose-directed water and the entry of
water during occasional temporary submersion at a limited depth; and that will be undamaged by the
external formation of ice on the enclosure.
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt; against hose-directed water and the entry of
water during prolonged submersion at a limited depth; and that will be undamaged by the external
formation of ice on the enclosure.
Enclosures constructed (without knockouts) for indoor use to provide a degree of protection
(personnel against incidental contact with the enclosed equipment) against falling dirt; against
circulating dust, lint, fibres, and flyings; and against dripping and light splashing of liquids.
Enclosures constructed (without knockouts) for indoor use to provide a degree of protection
(personnel against incidental contact with the enclosed equipment) against falling dirt; against
circulating dust, lint, fibres, and flyings; and against dripping and light splashing of liquids.
For either indoor or outdoor use to provide a degree of protection (personnel against incidental
contact with the enclosed equipment) against falling dirt; against circulating dust, lint fibres, and flyings;
and against the spraying, splashing, and seepage of water, oil, and non-corrosive coolants.
Smarter products
www.ehawke.com
61
Technical Data
Hazardous Locations
Enclosure Type
Number
Application
For indoor use in hazardous locations classified as Class I, Division 1, Groups A, B,
C, or D as defined in NFPA 70.
For indoor use in hazardous locations classified as Class II, Division 1, Groups E, F,
or G as defined in NFPA 70.
For indoor use in hazardous locations classified as Class II, Division 1, Groups E, F,
or G as defined in NFPA 70.
7
8
9
Further information can be found in NEMA Standard Publication 250 and UL 50 Standard Publication.
The enclosures are designed to protect and to provide additional protection as stated below: -
NEMA Enclosure
Type Number
IP10
IP11
IP54
3R
IP14
3S
IP54
4 and 4X
IP56
IP52
6 and 6P
IP67
The IEC and CENELEC 60529 Standards and NEMA degrees of protection can not be fully compared as
equivalent ratings. The NEMA Standard includes tests for environmental conditions such as mechanical
damage, corrosion, rusting, ice formation, etc.
AEx
ANSI
API
ATEX
Smarter products
www.ehawke.com
62
Technical Data
CEC
Canadian Electric Code. The CEC, Part 1, CSA Standard C22.1, is a safety standard
for the installation and maintenance of electrical equipment.
CEN
CENELEC
CEPEL
CFR
Cold Flow
CSA
DNV
EECS
EEx
Explosionproof
Certain types of cable employ materials that can exhibit "cold flow" characteristics
that could have adverse effects on the protection of the apparatus. Where such cable
is used, a suitable cable entry device should be employed, for example cable entry
devices not employing compression seals that act upon the part(s) of the cable
having "cold flow" characteristics. "Cold flow" can be more fully described as
thermoplastic materials that flow when subjected to pressure at ambient
temperature.
Canadian Standards Association. A service they offer includes testing and
certification services to US and Canadian Standards, as well as international
certification through agreements with other approval authorities.
Det Norske Veritas
Electrical Equipment Certification Service (UK). They provide a range of testing and
certification services primarily related to equipment and systems intended for use in
potentially explosive atmospheres. EECS has two divisions, the Mining Equipment
Certification Services (MECS), and BASEEFA. The EECS is a branch of the Health &
Safety Executive, UK.
A marking prefix for apparatus complying with one or more types of explosion
protection techniques in accordance with CENELEC standards.
A term used to describe equipment that is capable of withstanding an explosion of a
specified gas or vapour that may occur within it and preventing the ignition of a
specified gas or vapour surrounding it.
Smarter products
www.ehawke.com
63
Technical Data
Flameproof
FM
Hazardous Areas
IADC
IEC
IECEx
Increased Safety
INMETRO
Intrinsically Safe
System
Impervious
Sheathed Cable
IP
ISA
ISO
ITS
Marine Shipboard
Cable
Smarter products
www.ehawke.com
64
Technical Data
NFPA
OSHA
PLTC
Potentially
Explosive
Atmosphere
SCS
TC
SIRA Certification Service (UK). They provide a range of testing and certification
services and have agreements with other international approval authorities.
Power and control cable as defined by NEC Article 340
UL
USCG
Smarter products
www.ehawke.com