Drger Pendula
Agenda
2/28
Customer need
Competition
Solution
Sales Argumentation
Workplace examples
Documentation
Drger Pendula
Customer need
Drger Pendula
Customer need
Hybrid OR
Imaging and surgical equipment in one room
Operating Room
Diagnostics
Surgery
Equipment
Equipment
Infusion-/syringe pumps
Cell Saver
Diagnostic imaging:
CT; special C-arm
HybridOR
Catheter trolley/tables
Suction unit
Ultrasound diagnosis/echocardography device
Equipment table
Defibrillator
Heart-lung machine
Anaesthesia workplace
Minimal invasive surgery tower
Air conditioning plants
4/28
Drger Pendula
Customer need
Hybrid OR
Infrastructure and equipment are complex
- Often less space for more equipment
- Common planning of equipment with hospital
and other medical equipment provider is absolutely
necessary
A lot of people are involved:
- Surgeons, Cardiologist
- Planning architects
- Other device provider
- Hospital management
- Purchase department
- Hygienist
-
5/28
Drger Pendula
Customer need
Part of an Angiography system is a monitor application.
All relevant data and information for the personal are shown on the monitors
during a Hybrid surgery
1. Flexibility in design and configuration
2. High safety & hygienic standard
3. Ergonomic workplace solution
4. Easy installation and service
6/28
Drger Pendula
Customer need
1. Flexibility in design and configuration
- Depends on the clinical application which will be performed
angiography systems require till to 8 monitors or one large screen
- The Hybrid OR requires a lot of medical equipment and devices.
- Compact systems and space saving solutions are needed to
have more space for personal and work procedures.
- The OR ceiling is often crowed with a lot of systems. therefore
there is a need for compact ceiling fixtures and combinations with
other systems to save space.
Drger Pendula
Customer need
3. Ergonomic workplace solution
- Easy access to monitors and enough space around these
are through a lot of devices, instruments and personal rare.
Fast and easy monitor positioning from all site is required.
- Flexibility to re-positioning the monitors from one site to
another site of the OR table depends on clinical application.
If the monitor application is not needed, it must get out of
the work area.
- Clear and easy user handling concept is required for fast
positioning especially in case of emergency.
- best ergonomic view on the monitors from different
personal.
- Different surgery procedure requires individual positioning of
monitors in the working area of the surgeon
Drger Pendula
Agenda
9/28
Customer need
Competition
Solution
Sales Argumentation
Workplace examples
Documentation
Drger Pendula
Competition Siemens Standard Solution
Siemens use the Gas spring arm from Mavig in their projects since several years. Their
system is especially used in the Radiology. The solution is made up of a rail system
mounted at the ceiling, a gas spring arm and the monitor array.
Strength:
- standard system for MRI or radiology.
Weaknesses:
- Rail mounted system leads to
- less positioning flexibility in the OR
- Hygienic issues: abrasion due to rails
above the OR field and cabling partly
outside of the system
- Limited space on the ceiling due to the
complex rail system
- Positioning only from the frontside of the
system
10/28
Drger Pendula
Competition Ondal
Ondal and Eizo promote a turn key solution = holder + displays.
CEMOR Carrier Systems
Strength:
- Gap-free mounting tailored for Eizo monitors
- Tilting of the flat screens 5vertically and horiz ontally
for ideal viewing angle
- Internal cable routing
- Corner protection from all sides
- Completely assembled and cabled system
- System is intended for flat screens of Eizo
Weaknesses:
- bulky Design
- Only for Eizo monitors
- not approved cables from partner of angiography
suite
-user control concept unclear
11/28
Drger Pendula
Competition Trumpf, Maquet, Stryker
Maquet, Trumpf and Stryker can offer a similar solution like Drger in the past do.
Strength:
- Comparable solution to Drgers Pendula
Weaknesses:
- Not completly validated and certified in
collaboration between competitor and Mavig
- No own solution, they have to use the Siemens
solution, which can be used only for Siemens
installations
- No integrated keypad or handles for positioning
of the system
- Lift arm adjustment is limited
12/28
Drger Pendula
Agenda
13/28
Customer need
Competition
Solution
Sales Argumentation
Workplace examples
Documentation
Drger Pendula
Solution
The compact Multiple Monitor Holder Drger Pendula
14/28
Drger Pendula
Solution
15/28
Drger Pendula
Solution
Features:
- Stationary ceiling fixation
- Spring arm adapted to Drger arm
- Freely suspended system that swings away
(horizontally and vertically) in case of collisions
- The swinging fixation underneath the lift arm
supports an automatic upright positioning of the
system and protect the displays and other
equipment in case of collisions
- Integrated cable management
- Protection tubes around the monitors
- Flexible arrangement in number and size of the
displays (2-8 displays (19/ 21) or 1x 56 +
backup-screens)
16/28
Drger Pendula
Solution
Technical data:
- Maximum vertical adjustment up to 800mm
- Total reach of the system: 2,5 m.
- Max. load capacity: 110kg
- Max load for monitors: 75kg
17/28
Drger Pendula
Solution
Variants:
4 arm lengths 1750mm 2500mm
7 monitor frames
2-8 monitors optimized for 19; 21monitors can be also mounted
56large display
3-fold
18/28
56 inch
6-fach
Drger Pendula
Dimensions
twofold
threefold
19/28
fourfold
six fold
eightfold
56 inch version
Drger Pendula
Solution
Some more details:
Cable Management
Keypad
20/28
Drger Pendula
Agenda
21/28
Customer need
Competition
Solution
Sales Argumentation
Workplace examples
Documentation
Drger Pendula
Sales argumentation
Customer need: Flexibility in design and configuration
Enhanced flexibility
-
Monitor frames in different sizes and open for all system provider - a tailored
solution for each monitor application.
Space saving solution at the ceiling through one ceiling fixation. And
combination with other Drger supply units, multiple monitor holder or Drger
operating lights possible More space for other equipment and personal in
work area + more flexibility in designing a hybrid OR
Long reach till 2,5m and higher use radius in comparison to the rail mounted
solution
12-upside spring arm and 800mm hub allows a flexi ble OR design
Positioning of the monitors possible from all sides due to ergonomic positioned
control handles at back side, keypad at the front side and a frame around the
system
Drger Pendula
Sales argumentation
Customer need: High safety & hygienic standard
Safety first
-
less edges and corners + tested surfaces improve the cleaning and
disinfection process
Drger quality
- High Drger expertise in planning and project management supported through
the right tools as e.g. 3d tool
- Drger partnering with other medical equipment supplier supports the complete
planning process of a Hybrid OR
- Establish Drger ceiling fixation, easy re-configurable system through standard
interfaces. fast opening system optimizes the installation and the service
procedure.
23/28
Drger Pendula
Agenda
24/28
Customer need
Competition
Solution
Sales Argumentation
Workplace examples
Documentation
Drger Pendula
Workplace examples
Project hospital Karlsburg, Germany (2010)
25/28
Drger Pendula
Workplace examples
-ESC, Aug. 2011, Paris, France
-CIRSE, Sept. 2011, Munich, Germany:
26/28
Drger Pendula
Workplace examples
27/28
Drger Pendula
Agenda
28/28
Customer need
Competition
Solution
Sales Argumentation
Workplace examples
Documentation
Drger Pendula
Documentation
Instructions for use 9053268
Installation Instructions 9053295
Sales View:
TechSpecs
Projecting guideline
Offer texts
Tender texts
3d film and pictures
Partnering / Planning documents