Tunnel Shotcrete Design-1

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Steel Fibre Reinforced Shotcrete Tunnel Lining Design

After: Barrett and McCreath (1995)


Inputs
s
Shape
j
h

W
weq

2
Wedge

m
Wedge

m
kN/m3
kN

=B9*(IF(B6="Wedge",1/3*B5^2*B5/2/TAN(RADIANS(B7)),B8*B5^2))

13.9

kN/m

=B8/B5^2

0.15

fy

MPa

fa

1
0.03
0.075

MPa
m
m

a
t
Adhesion
Ca

240

kN

check: Ca > 1.5 * W


Flexure
M
Mmax

Square Block

30
24
55.4

=4*B12*B5*B13*1000
OK

7.97

kNm

=1/8*(B9*B5^2*(1+0.15))

3.75

kNm

=1/6*B11*B5*B14^2*1000

check: 0.8 * Mmax > 1.5 * M


Geometry
Wedge

Not OK

Square Block

h
j

Note
In good ground adhesion may be relied upon. In poor ground flexural capacity must be provided.

Steel Fibre Reinforced Shotcrete Tunnel Lining Design


After: Barrett and McCreath (1995)
Inputs
s
Shape
j
h

W
weq

3.6
Wedge

m
Wedge

m
kN/m3
kN

=B9*(IF(B6="Wedge",1/3*B5^2*B5/2/TAN(RADIANS(B7)),B8*B5^2))

24.9

kN/m

=B8/B5^2

0.15

fy

MPa

fa

1
0.03
0.075

MPa
m
m

a
t
Adhesion
Ca

432

kN

check: Ca > 1.5 * W


Flexure
M
Mmax

Square Block

30
24
323.2

=4*B12*B5*B13*1000

Not OK

46.47

kNm

=1/8*(B9*B5^2*(1+0.15))

6.75

kNm

=1/6*B11*B5*B14^2*1000

check: 0.8 * Mmax > 1.5 * M


Geometry
Wedge

Not OK

Square Block

h
j

Note
In good ground adhesion may be relied upon. In poor ground flexural capacity must be provided.

You might also like