Installation & Operational Guide - Ver.2.9
Installation & Operational Guide - Ver.2.9
com
LOGO
INTRO
1)
2)
3)
4)
5)
Calculate and consider the output power of BTS and Input signal level of TMB-9100
6)
TMB-9100 is very high powered RF so that Be careful when you set TMB parameters.
7)
Remote GUI: Click MAIN" button (Refresh) after getting SMS from TMB-9100
8)
9)
www.gsinstrument.com
LOGO
TMB-9100 Configuration
www.gsinstrument.com
LOGO
Step 1. TMB Installation (Before)
* Preparation
www.gsinstrument.com
LOGO
Step 1. TMB Installation (Before)
* Open Local GUI
www.gsinstrument.com
LOGO
Step 1. TMB Installation (Before)
Check F/W version: 2.9
Check Initial parameter setting
www.gsinstrument.com
LOGO
Step 1. TMB Installation (Before)
* Set Server Min No through Local GUI (Mandatory)
www.gsinstrument.com
LOGO
Step 1. TMB Installation (Before)
1) Enter Site Name
2) TMB SIM Card Number
2) Enter Alarm Reporting upto 4 number
www.gsinstrument.com
LOGO
Step 1. TMB Installation (Before)
* Insert SIM Card to MCU of TMB
www.gsinstrument.com
LOGO
Step 2. TMB Installation
* Install TMB at right position
10
www.gsinstrument.com
LOGO
Step 3. DC Cable Installation
1)
2)
3)
11
www.gsinstrument.com
LOGO
Step 3. DC Cable Installation
4) Connect DC jack with DC cable
Local electrical code should be followed in connecting DC power to the MCPA 9100 system. In order
to connect DC Cable, connect cable to DC INPUT port, and then connect the other end to DC Power
Source. The DC input power cable is illustrated in Figure 1.
The DC cable from the base station is connected to the DC INPUT port as shown in Figure 1. Use
two AWG08 cable to the DC INPUT through bottom interface panel. The DC cable should be
protected with a 40-amp minimum circuit breaker.
B: -48Volt, A: Ground
www.gsinstrument.com
LOGO
Step 3. DC Cable Installation
13
Step1: Preparation
Step2: Preparation
www.gsinstrument.com
LOGO
Step 3. DC Cable Installation
Step5: Strip the wire
14
www.gsinstrument.com
LOGO
Step 3. DC Cable Installation
Step9: Apply heat to contraction tube
15
www.gsinstrument.com
LOGO
Step 4. Power Off BTS
1) Turn off the power amplifier (A Sector) of BTS
16
www.gsinstrument.com
LOGO
Step 5. Cable Connection
1)
2)
BTS
ANTENNA
Feeder
Feeder
17
Jumper
Feeder
Feeder
www.gsinstrument.com
LOGO
Step 5. Cable Connection
3) Connect Jumper cables to each port
18
www.gsinstrument.com
LOGO
Step 6. TMB Setting Remote Access
Remote GUI
Caution: Please reinstall modem box and SIM card if responding is not good
1) Please disconnect and take out the SIM card and then plug in again
2) Please change your com port in your pc
19
www.gsinstrument.com
LOGO
Step 6. TMB Setting Remote Access
20
www.gsinstrument.com
LOGO
Step 6. TMB Setting Remote Access
www.gsinstrument.com
LOGO
Step 6. TMB Setting Remote Access
7) Click Status Req, Info Req, and Control
22
www.gsinstrument.com
LOGO
Step 6. TMB Setting Remote Access
8) Click Refresh or Main button.
If Alarm LEDs are not updated after receiving SMS from TMB, please click Main button
[After]
[Before]
23
www.gsinstrument.com
LOGO
Step 6. TMB Setting Remote Access
9) Status Request information
24
www.gsinstrument.com
LOGO
Step 6. TMB Setting Remote Access
10) Info Request information
25
www.gsinstrument.com
LOGO
Step 6. TMB Setting Remote Access
11) Control button Set parameters
26
www.gsinstrument.com
LOGO
Step 7. Turn on TMB
27
www.gsinstrument.com
LOGO
Step 8. Turn on BTS
28
www.gsinstrument.com
LOGO
Step 9. Input Signal Level Checking
1) Check Input Signal Level
Caution: Please Consider and Calculate the input signal level and loss.
29
www.gsinstrument.com
LOGO
Step 9. Input Signal Level Checking
2) Alarm Checking
ALARM CHECK
30
www.gsinstrument.com
LOGO
Step 10. TMB Gain Setting
1) Check Output Power of GUI (TMB Gain 0)
* Generally you can see the total output power for Signaling channel on the top of the tower.
31
www.gsinstrument.com
LOGO
Step 10. TMB Gain Setting
2) TX Output Power setting (Reference)
TX output power setup table Below table is for reference in input power variation +/-1dB
Output Power
(TMB Gain 0dB)
MCPA9100Output Power
2CH
80W
49.3dBm
43
12
51dBm
4CH
87W
49.4dBm
42
11
51dBm
8CH
80W
49.3dBm
41
10
10
51dBm
32
www.gsinstrument.com
LOGO
Step 11. TMB Gain Setting
- LNA Gain Setting
* According to a site, it can be changed. It is basic setting of TMB-9100
1)
2)
33
TMB Output Power Input signal power = TMB TX Gain or Check the GUI
RX & DIV Gain
NO
TX GAIN
RX GAIN
DIV GAIN
1 10dB
12dB
12dB
11 20dB
14dB
14dB
Remark
www.gsinstrument.com
LOGO
Step 11. TMB Gain Setting
- Check TX / RX / DIV Gain (LNA Gain can be higher than TX Gain)
- Check output power of TMB
- Check Alarm LED
Gain setting
Output Power Check
34
www.gsinstrument.com
LOGO
Step 11. TMB Setting Others
1) Enter Site Name
2) TMB SIM Card Number
2) Enter Alarm Reporting upto 4 number
35
www.gsinstrument.com
LOGO
Step 12. Check output Power
1)
2)
TX Coupling port (-40 dB +/- 1dB) using a spectrum analyzer. And Add jumper cable loss.
To protect the spectrum analyzer, use TX coupling port -20 dB fixed attenuator.
36
www.gsinstrument.com
LOGO
Step 12. Check output Power
37
www.gsinstrument.com
LOGO
Appendix 1: TMB Operation
1. Auto Attenuation Function
- TMB has automatic function to protect its circuit while output power is higher than 52dBM in traffic increasing time
- The reduction of TX Gain will be reduced and the step is 0.5dB
2. ALC Mode
- In high traffic sector, please set ALC Mode On and ALC Level.
- Max ALC level range is from 40 to 51dB.
- It will automatically optimize the TX Gain with 0.5dB step.
3. Auto Recovery Algorithm
- TMB will alive automatically if TMB has Overpower alarm after 3minutes.
4. TMB Power Detection time
- 100ms
- It will provide real time measurement but the accuracy will be less than Spectrum Analyzer.
5. SMS delay or missing
- While MCU is working with other job, it cannot update or report alarms and control command.
- Try again to set or check TMB unit.
- After setting TMB, it takes time to report new information. Tray again to get new information.
- Responding time for Control command: 5sec to set (general environment)
- Responding time for Request command: 10-20sec (general environment)
38
www.gsinstrument.com
LOGO
Appendix 2: Remote GUI & Modem Box
Checking Points
1. Local GUI and Remote GUI are optimized for O/S of Window 7 and XP.
Other version of O/S cannot be suitable for GUIs and Remote Access.
2. Modem Box cannot be compatible for USB port of your PC. Please use other USB Port or your PC if
there are several Pop-up menu for disconnection.
3. If the communication between GUI and Modem box are disconnected, Pop up -menu can be generated.
Please click ok and check Modem
4. If you order several message in case that you cannot
receive replies from TMB or other purpose, this modem
can handle every requests from you and TMB so that this
message will be come.
Please restart Remote GUI for solving the matter or
turn off /on the modem box.
5. In few case, SIM card error will be happened.
You connect and check everything is OK but if the
communication between GUI and TMB is not proper,
Please check SIM Card connection or SIM Card Error.
6. In Rare cases, the received SMS from TMB cannot be erased in Modem Box so that it can make unstable Remote
Access. Please check SMS Clean button
39
www.gsinstrument.com
LOGO
Appendix 1: TMB-9100 Modules
* A Module 1) TX Variable Attenuation
* DIV LNA: Diversity Low Noise Amplifier
* MCPA: 1) Multi carrier power amplifier 150W
* By Pass Relay1: 1) DIV path bypass (RX1 signal )
* Main LNA: RX Low Noise Amplifier
* I/O Board:
to control and manage Power Supply & Control Signal, Alarm Signal, and
Detected information from/to all Modules except of MCPA
* DC Power Supply
DC to DC Converter that outputs DC27V, DC12V, and DC9V
www.gsinstrument.com
LOGO
- THE END -
41
www.gsinstrument.com