Professional Documents
Culture Documents
Liquiline CM42 LIGAÇÕES TI381CEN PDF
Liquiline CM42 LIGAÇÕES TI381CEN PDF
Liquiline M CM42
pH/ORP/conductivity/concentration/resistivity/digital sensors
Two-wire transmitter for Ex and non-Ex areas
68901
Application
Your benefits
Cost-saving:
Simple commissioning with Quick Setup and Navigator
(multifunction button)
Thanks to Memosens technology, a calibration in the plant
is not required
Predictive maintenance system detects when a sensor has
to be cleaned, calibrated or replaced
Less storage thanks to modular design
Safe:
Active display of cable interruption with Memosens
version
Red alarm LED reports error immediately
User-guided commissioning, graphic display and plain text
guidance
SIL 2, ATEX, FM, CSA, NEPSI, TIIS, IP 67, NEMA 4X
Code-protected commissioning and calibration
Connection of all types of pH sensors (glass, ISFET, digital
sensors) and conductivity sensors
Industry solutions:
Modular concept: sensor module replaceable
Asset management (Fieldcare, W@M)
TI381C/07/en/05.05
51517610
Liquiline M CM42
General features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mechanical construction . . . . . . . . . . . . . . . . . . . . . . 23
Modular design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Quick setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Navigator and plain text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Sensor monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Process check system (PCS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Software packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Special features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
pH / ORP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Conductivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Digital sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Human interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Operating elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Ordering information. . . . . . . . . . . . . . . . . . . . . . . . . 25
Product structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Output signal range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ex specification current output 4/20 mA . . . . . . . . . . . . . . . . . . 10
Ex specification PROFIBUS PA and FOUNDATION Fieldbus . . . . 10
4 approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
pH / ORP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Conductivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Digital sensors (additional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Operating Instructions CM42 . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Housing grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Supply and signal circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sensor connection: pH / ORP . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Sensor connection: conductivity . . . . . . . . . . . . . . . . . . . . . . . . . 17
Sensor connection: digital sensors . . . . . . . . . . . . . . . . . . . . . . . . 18
Performance characteristics. . . . . . . . . . . . . . . . . . . . 19
pH / ORP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Conductivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Digital sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Mounting plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Weather protection cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Installation in Ex area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Ambient temperature limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Electromagnetic compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Ingress protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Relative humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Endress+Hauser
Liquiline M CM42
General features
Modular design
a0001296
a0001979
Quick setup
a0001984
Navigator
Sensor monitor
a0001985-en
Pressing the DIAG key takes you to the sensor monitor. All the important sensor data, incl. warning and alarm
limits, are graphically displayed in one go.
a0001771-en
Endress+Hauser
This function checks the measuring signal for stagnation. If the measuring signal does not change for some time
(several measured values), an alarm is triggered. Soiling, blockage or similar could be the cause of such
behaviour.
Liquiline M CM42
Software packages
Safety
pH /ORP
Conductivity
Digital sensors
Endress+Hauser
Liquiline M CM42
Special features
pH / ORP
Conductivity
Polarisation monitoring
Polarisation effects in the boundary layer between the sensor and the solution to be measured limit the
measuring range of conductive conductivity sensors.
The transmitter can detect and indicate polarisation effects using an innovative, intelligent signal evaluation
process.
United States Pharmacopeia (USP) and European Pharmacopoeia (EP)
The requirements on ultrapure water in the pharmaceutical industry are specified by the American USP and
the European EP.
The transmitter meets the USP/EP requirements on conductivity measuring systems:
Precise temperature measurement at point of conductivity measurement
Simultaneous display of uncompensated conductivity values and temperature
Display resolution 0.01 S/cm
Exact adjustment of the transmitter in the factory with traceable precision resistances (optional)
Exact adjustment of the sensors in the factory in accordance with ASTM D 1125-9 resp. ASTM D 5391-99
(optional)
Temperature-dependent measured value monitoring acc. to USP and EP.
Digital sensors
Memosens
The measuring point is safer with Memosens:
No-contact, inductive signal transmission, thus optimum galvanic separation
No contact corrosion
Completely water-tight
Automatic error message if data flow interrupted
Sensor calibration possible in laboratory
Look-ahead maintenance thanks to recording of sensor data, e.g.:
Total hours of operation
Hours of operation for very high or very low pH values
Hours of operation for high temperatures above 80 C (176 F) and 100 C (212 F)
Number of steam sterilisations
Endress+Hauser
Liquiline M CM42
Measuring system
a0002012
pH / ORP
CM42-P/R...
Measuring cable CPK9
Assembly Cleanfit CPA471
Sensor Orbisint CPS11
Conductivity, inductive
measurement
CM42-I...
Assembly Dipfit CLA111
Sensor Indumax CLS50
Conductivity, conductive
measurement
CM42-C...
Measuring cable CPK9
Sensor Condumax CLS16
Digital sensor
CM42-M...
Measuring cable CYK10
Assembly Unifit CPA442
Sensor Oxymax COS22
Note!
You can select from a wide variety of assemblies and sensors to set up your measuring point. You can find the
corresponding information in the chapter "Accessories" resp. in the referenced documentations.
Endress+Hauser
Liquiline M CM42
Input
pH / ORP
Measured variable
pH value
Oxidation-reduction potential (ORP)
Temperature
Measuring range
pH value
2 to 16
ORP
2000 to +2000 mV
Temperature
Cable specification
Without SCS
With SCS
Endress+Hauser
Glass electrode
10.08 V
4.1 mA
10.2 mW
200 H
150 nF
ISFET
10.08 V
50.7 mA
128 mW
200 H
150 nF
Liquiline M CM42
Conductivity
Measured variable
Conductivity
Resistivity
Concentration
Measuring range
Conductivity, conductive measured
Two-polar sensor
Four-polar sensor
10 M/k ... 50 /k
Concentration
1)
2)
Cable specification
Conductivity/resistivity, conductive measured1)
Two-cell sensor
100 m (328.10 ft) max. cable length
10 S.k to 20 mS.k / 0.1 M/k to 50 /k
5 S.k to 20 mS.k / 0.2 M/k to 50 /k
50 m (164.05 ft) max. cable length
0.1 S.k to 20 mS.k / 20 M/k to 50 /k
15 m (49.22 ft) max. cable length
Conductivity, conductive measured
Four-cell sensor
10 S.k to 1.5 S.k
0.1 S.k to 20 mS.k
1)
2)
Temperature sensor
Pt100
Pt1000
Ex specification, conductive sensors
10.08 V
23 mA
57 mW
335 H
4 nF
Endress+Hauser
Liquiline M CM42
10.08 V
64 mA
128 mW
62 nF
Digital sensors
Measured variable
pH value
Oxidation-reduction potential
Temperature
Measuring range
pH value
2 to 16
ORP
2000 to +2000 mV
Temperature
Cable specification
With Memosens
Ex specification
Endress+Hauser
5.04 V
70 mA
128 mW
447 nF
105.6 H
Liquiline M CM42
Output
Output signal
Signal on alarm
21.5 mA
digital via field bus4
Load
Ex specification
current output 4/20 mA
pH
ORP
adjustable, U > 5 mV
none
none
Temperature
adjustable, T > 2 C
0 Intrinsically safe supply and signal circuit with protection type: EEx ia IIC T6 passive
Max. input voltage Ui
Max. input current Ii
Max. input Pi
Max. inner inductivity Li
Max. inner capacity Ci
Ex specification PROFIBUS PA
and FOUNDATION Fieldbus
1)
2)
3)
4)
10
30 V
100 mA
750 mW
221 H (output 1)
neglegiable (output 2)
1.2 nF (output 1)
neglegiable (output 2)
17,5 V
380 mA
5.32 W
38.4 H
neglegiable
Endress+Hauser
Liquiline M CM42
Wiring
Housing grounding
Plastic housing
"
Caution!
You must connect the "EMC barrier" to the foundation earth with a separate 4 mm2 functional earth line.
a0003617
Housing grounding
1
2
EMC barrier
4 mm2 functional earth
"
Caution!
You must connect the outer earth connection of the housing to the foundation earth with a separate 4 mm2
line (GN/YE).
2
a0003616
Housing grounding
Note!
Connect the transmitter via a two-wire cable screened on each end.
133
134
4 ... 20 mA
4 ... 20 mA / Hart
1
2
133
134
a0001092
Wiring diagram
a0001091
Endress+Hauser
11
Liquiline M CM42
Note!
Always use a fieldbus cable that is grounded on both sides (device and PCS).
You can connect Profibus and FOUNDATION Fieldbus devices in three ways:
Screened two-wire cable, "Hard grounding"
(generally to be preferred to capacitive grounding)
Screened two-wire cable, "Capacitive grounding"
(if there is a risk of high equalizing currents)
Using the fieldbus connection socket (accessories)
Version 1: "Hard grounding"
1.
2.
997
998
a0001640
Wiring diagram
a0004060
2.
3.
998
133 132
998
997
997
1.
a0004073
Wiring diagram
EY
/NG
a0004071
12
Endress+Hauser
Liquiline M CM42
Screw the fieldbus connection socket (accessories) into the housing bushing.
2.
3.
Connect the cable cores as per the assignment. In doing so, you must place the cable screen (GN/YE) on
the "EMC barrier".
997
998
a0004062
Wiring diagram
a0002378
Supply voltage
Current output 4 to 20 mA without Hart:
Current output 4 to 20 mA with Hart:
PROFIBUS / FOUNDATION Fieldbus:
(max. 22 mA)
12.5 to 30 V DC
12.5 to 30 V DC
9 to 32 V DC (non-hazardous area) /
9 to 17.5 V DC (hazardous area)
Sensor connection
Explanation of abbreviations in the following diagrams:
Endress+Hauser
Abbreviation
Meaning
pH
Ref
Src
Drn
PM
U+
U
Com A
Com B
d.n.c.
Note!
Cable colours indicated as per IEC 757 (see CD-ROM).
You must connect shielded connections and terminals with functional earth ()) (there is no protective earth
(*) for plastic housings).
13
Liquiline M CM42
112
113
111
320
318
317
CM42
CPK9
Sensor
GN
WH
YE
112
BN
113
GN
WH
BK
111
YE
315
CPK1
316
320
BN
318
BN
PM
BK
Ref
317
pH
319
PM
a0001088
View in device
a0001079
Wiring diagram
112
113
111
320
317
CM42
Sensor
GN
WH
112
YE
GN
J
113
BK
BN
111
WH
YE
315
CPK1
316
320
BN
BK
318
Ref
317
pH
d.n.c.
319
d.n.c.
BN
a0001089
View in device
14
a0001080
Wiring diagram
Endress+Hauser
Liquiline M CM42
112
113
111
315
316
320
318
GN
CM42
CPK12
Sensor
WH
YE
112
RD
BN
BK
113
111
GN
WH
YE
315
Src
Ref
316
320
RD
Drn
BN
PM
BN
318
BK
317
PM
319
a0001090
View in device
a0001076
Wiring diagram
112
113
111
315
316
320
CPK12
CM42
GN
WH
YE
112
RD
BK
113
Sensor
GN
WH
BN
111
YE
Src
315
Ref
316
320
RD
Drn
BK
BN
318
d.n.c.
317
d.n.c.
319
BN
a0001084
View in device
Endress+Hauser
a0001077
Wiring diagram
15
Liquiline M CM42
Glass/redox
ISFET
with PML
without PML
with PML
without PML
112
(GN)
(GN)
(GN)
(GN)
(GN)
113
(WH)
(WH)
(WH)
(WH)
(WH)
111
(YE)
(YE)
(YE)
(YE)
(YE)
Src
Src
Drn
Drn
PM
Ref
315
316
320
PM
318
Ref
317
pH
Ref
Difference
electrode
PM
Ref
pH
pH
319
pH
Version: CM42-R...
As version CM42-P and also:
Terminal
pH+redox
pH+pH
with PML
without PML
with PML
without PML
112
(GN)
(GN)
(GN)
(GN)
113
(WH)
(WH)
(WH)
(WH)
111
(YE)
(YE)
(YE)
(YE)
PM
Ref (pH)
PM
Ref (pH-1)
318
Ref (pH+ORP)
Ref (ORP)
317
pH
pH
pH
pH
319
ORP
ORP
pH
pH
315
316
320
16
Endress+Hauser
Liquiline M CM42
Sensor connection:
conductivity
112
113
111
219
220
CM42
CPK9 / CYK71
Sensor
GN
WH
YE
112
BK
113
GN
WH
BN
111
YE
219
220
BK
d.n.c.
222
221
BN
a0001086
View in device
a0001083
Wiring diagram
112
113
111
219
220
222
221
CM42
GN
WH
YE
Sensor
112
BK
BK
113
111
219
220
222
221
a0002363
Endress+Hauser
a0002371
Wiring diagram
17
Liquiline M CM42
215
216
112
113
111
218
217
Inductive sensors
CM42
RD
RD
GN
WH
YE
WH
WH
CLK5
Sensor
215
216
112
113
111
GN
WH
YE
218
217
a0001085
View in device
a0001082
Wiring diagram
187
188
197
198
Sensor connection:
digital sensors
BN
WH
GN
YE
a0001087
View in device
18
a0001078
Wiring diagram
Endress+Hauser
Liquiline M CM42
Performance characteristics
pH / ORP
Reference temperature
25 C (77 F)
Measured value resolution
pH:
Glass electrodes:
ISFET sensors:
ORP:
0.01 pH
0.01 pH
1 mV
Temperature:
NTC30k:
Pt100 / Pt1000:
0.1 C (0.1 F)
0.1 C (0.1 F)
100 k
100
100 nA
0.02 pH
0.02 pH
1 mV
Temperature:
NTC30k:
Pt100 / Pt1000:
0.5 K
0.25 K
Conductivity
200 M
200
100 nA
Reference temperature
25 C (77 F)
adjustable from 5 to 100 C (23 to 212 F)2
Measured value resolution
Conductivity
minimum, at:
cell constant k 0.15 cm-1
cell constant k 1.5 cm-1
cell constant k > 1.5 cm-1
1)
2)
0.01 C (0.01 F)
Resistivity
minimum
Endress+Hauser
19
Liquiline M CM42
Four-polar sensors
1)
2)
from 10 S.k to 1000 mS.k (max. cable length 100 m (328.1 ft))
3)
from 10 S.k to 1500 mS.k (max. cable length 100 m (328.1 ft))
4)
Temperature compensation
Type of compensation
none
linear
NaCl acc. to IEC 746-3
natural waters acc. to IEC 7888
Ultra-pure water NaCl
Ultra-pure water HCl
Range
= 0.00 to 20.00 % / K
0 to 100 C (32 to 212 F)
0 to 35 C (32 to 95 F)
0 to 100 C (32 to 212 F)
0 to 100 C (32 to 212 F)
Temperature adjustment
Temperature offset
Digital sensors
5 to +5 C (23 to 41 F)
1)
20
0.01 pH
0.01 pH
ORP
1 mV
Temperature
0.1 C (0.1 F)
Endress+Hauser
Liquiline M CM42
Installation
Mounting plate
a0001075-en
Mounting plate
Plastic housing
a0001671-en
300 / 11.81
320 / 12.60
270 / 10.63
mm / inch
a0001676-en
Endress+Hauser
21
Liquiline M CM42
Installation in Ex area
a0001312-en
Installation in Ex area
Sensor in Ex version
1
Intrinsically safe sensor circuit EEx ia
2
Transmitter
3
Supply and signal circuit EEx ib (4...20 mA)
4
5
6
7
8
Environment
Ambient temperature range
Storage temperature
40 to 80 C (40 to 176 F)
Electromagnetic compatibility
Ingress protection
IP 67
Relative humidity
22
Endress+Hauser
Liquiline M CM42
Mechanical construction
Dimensions
Plastic housing
a0001074-en
Plastic housing
160 / 6.30
110 / 4.33
145 / 5.71
134 / 5.28
26 /
1.02
136.5 / 5.37
220 / 8.66
3 / 0.12
132.5 / 5.22
134.5 / 5.30
136.5 / 5.37
10/
0.39
95 / 3.74
174 / 6.85
174 / 6.85
mm / inch
a0001073-en
Dimensions
Endress+Hauser
23
Liquiline M CM42
Weight
Plastic housing
1.5 kg (3.3 lb)
Stainless steel housing
2.1 kg (4.6 lb)
Material
Plastic housing
Housing:
Housing seals:
Polycarbonate
EPDM
Human interface
Operating elements
a0001301
Overview of operation
1
2
3-6
7
24
Endress+Hauser
Liquiline M CM42
Ordering information
Product structure
Sensor input
A
C
I
M
P
R
No Module
Conductivity, conductive measurement
Conductivity, inductive measurement
Digital sensor, Memosens
pH (glass/ISFET) or ORP
pH (glass/ORP redundant) or ISFET
Approval
A
G
H
N
P
S
T
Certificate
A
B
C
not selected
Test certificate acc. to EN 10204, 3.1
Test certificate acc. to EN 10204, 3.1, factory calibration certificate
Output
0
1
2
3
Housing
0
1
Plastic
Stainless steel 1.4301 (AISI 304)
Cable entry
0
1
2
M20 x 1.5
NPT "
G
Software
EA
EB
EC
Standard version
Advanced version
Advanced Plus version
Device language
C
D
E
F
J
N
P
S
T
Documentation
0
1
Additional equipment
0
CM42-
Endress+Hauser
Basic version
complete order code
25
Liquiline M CM42
Scope of delivery
Declaration of conformity
The product meets the legal requirements of the harmonized European standards.
The manufacturer confirms compliance with the standards by affixing the 4 symbol.
Ex approval
26
Endress+Hauser
Liquiline M CM42
Accessories
pH / ORP
Glass electrodes
Orbisint CPS11/CPS11D
pH electrode for process applications, with PTFE diaphragm, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI028/C07/en)
Orbisint CPS12/CPS12D
ORP electrode for process applications, with PTFE diaphragm, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI367/C07/en)
Ceraliquid CPS41/CPS41D
pH electrode with ceramics diaphragm and KCl liquid electrolyte, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI079/C07/en)
Ceraliquid CPS42/CPS42D
ORP electrode with ceramics diaphragm and KCl liquid electrolyte, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI079/C07/en)
Ceragel CPS71/CPS71D
pH electrode with double chamber reference system and integrated bridge electrolyte,
Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI245/C07/en)
Ceragel CPS72/CPS72D
ORP electrode with double chamber reference system and integrated bridge electrolyte, Memosens
technology as option;
Ordering acc. to product structure, see Technical Information (TI374/C07/en)
Orbipore CPS91/CPS91D
pH electrode with open aperture for media with high dirt load, Memosens technology as option;
Ordering acc. to product structure, see Technical Information (TI375C/07/en)
ISFET sensors
Tophit CPS471
Sterilisable and autoclavable ISFET sensor for food and pharmaceuticals, process technology, water
treatment and biotechnology;
Ordering acc. to product structure, see Technical Information (TI283/C07/en)
Tophit CPS441
Sterilisable ISFET sensor for media with low conductivity, with liquid KCl electrolyte;
Ordering acc. to product structure, see Technical Information (TI352/C07/en)
Tophit CPS491
ISFET sensor with open aperture for media with high dirt load;
Ordering acc. to product structure, see Technical Information (TI377/C07/en)
Endress+Hauser
27
Liquiline M CM42
Assemblies
Cleanfit P CPA471
Retractable assembly for tank and pipe installation,
Cleanfit P CPA473
Pneumatically or manually driven retractable assembly with ball valve for reliable process termination, parts
in contact with medium of 1.4404 (AISI 316L) stainless steel
Cleanfit P CPA474
Pneumatically or manually driven retractable assembly with ball valve for reliable process termination, parts
in contact with medium of PP, PEEK or PVDF
a0001305
Fig. 1:
Cleanfit P CPA471
a0001306
Fig. 2:
Cleanfit P CPA473
a0001307
Fig. 3:
Cleanfit P CPA474
Cleanfit H CPA475
Retractable assembly for tank and pipe installation under sterile conditions,
Dipfit W CPA111
Immersion and installation assembly for open and closed tanks,
Unifit H CPA442
Installation assembly for food industry, biotechnology and pharmaceutical industry, with EHEDG and 3A
certificate,
a0001308
28
Fig. 4:
Cleanfit H CPA475
a0001309
Fig. 5:
Dipfit W CPA111
a0001310
Fig. 6:
Unifit H CPA442
Note!
All the assemblies can be ordered using the product structure. Please refer to the Technical Information of the
desired assembly in question.
Endress+Hauser
Liquiline M CM42
Measuring cables
CPK9 special measuring cable
For sensors with TOP68 plug-in head, for high-temperature and high-pressure applications, IP 68
Ordering acc. to product structure, see Technical Information (TI118C/07/en)
CPK12 special measuring cable
For pH/redox glass electrodes and ISFET sensors with TOP68 plug-in head
Ordering acc. to product structure, see Technical Information (TI118C/07/en)
Buffer solutions
Technical buffer solutions, accuracy 0.02 pH, acc. to NIST/DIN
pH 4.0 red, 100 ml (0.026 US gal.), order no. CPY 2-0
pH 4.0 red, 1000 ml (0.264 US gal.), order no. CPY 2-1
pH 7.0 green, 100 ml (0.026 US gal.), order no. CPY 2-2
pH 7.0 green, 1000 ml (0.264 US gal.), order no. CPY 2-3
Technical buffer solutions for single use, accuracy 0.02 pH, acc. to NIST/DIN
pH 4.0 20 x 20 ml (0.005 US gal.), order no. CPY 2-D
pH 7.0 20 x 20 ml (0.005 US gal.), order no. CPY 2-E
Technical buffer solutions for ORP electrodes
+225 mV, pH 7, 100 ml (0.026 US gal.); order no. CPY3-0
+468 mV, pH 0, 100 ml (0.026 US gal.); order no. CPY3-1
Conductivity
Conductive sensors
Condumax W CLS12
Conductive conductivity sensor for standard, Ex and high temperature applications;
Ordering acc. to version, see Technical Information TI 082/C07/en
Condumax W CLS13
Conductive conductivity sensor for standard, Ex and high temperature applications;
Ordering acc. to version, see Technical Information TI 083/C07/en
Condumax W CLS15
Conductive conductivity sensor for pure and ultra-pure water applications (incl. Ex);
Ordering acc. to version, see Technical Information TI 109/C07/en
Condumax H CLS16
Hygienic conductive conductivity sensor for pure and ultra-pure water applications (incl. Ex);
Ordering acc. to version, see Technical Information TI 227/C07/en
Condumax W CLS19
Conductive conductivity sensor for pure and ultra-pure water applications;
Ordering acc. to version, see Technical Information TI 110/C07/en
Condumax W CLS21
Conductive conductivity sensor for applications with middle to high conductivity
(incl. Ex); Ordering acc. to version, see Technical Information TI 085/C07/en
Inductive sensors
Indumax P CLS50
Inductive conductivity sensor for standard, Ex and high temperature applications;
Ordering acc. to the sensor version, see Technical Information (TI118C/07/en)
Indumax H CLS52
Inductive conductivity sensor with short response time in hygienic design;
Ordering acc. to the sensor version, see Technical Information (TI167C/07/en)
Endress+Hauser
29
Liquiline M CM42
Assemblies
Dipfit W CLA111
Immersion assembly for open and closed tanks with flange DN 100;
Order depending on version, see Technical Information (TI135C/07/en)
Dipfit P CLA140
For the inductive sensor CLS50
Immersion assembly with flange connection for processes with high requirements;
Order depending on version, see Technical Information (TI196C/07/en)
a0001303
Fig. 7:
a0001304
Dipfit P CLA140
Measuring cables
Special measuring cable / extension cable CYK71
for two-polar conductivity sensors with integrated temperature sensor,
one low-noise coaxial line, four auxiliary cores at 0.75 mm2 each with a common screen,
outer diameter 7 mm (0.25")
sold by the metre:
(minimum) length 5 m / 15 ft; order no. 50085333
length 5 m / 15 ft; order no. 50088280
length 10 m / 30 ft; order no. 50088281
length 50 m / 150 ft; order no. 50088284
length 100 m / 300 ft; order no. 50088285
Special measuring cable / extension cable CYK71-Ex
for Ex applications,
see CYK71, but with a blue sheath
sold by the metre, minimum length 5 m / 15 ft; order no. 50085673
Calibration solutions
Precision calibration solutions, acc. to SRM (Standard reference material) of NIST, error limit 0.5 %,
reference temperature 25 C (77 F), with temperature table
CLY11-A, 74.0 S/cm, 500 ml (0.132 Us.gal); order no. 50081902
CLY11-B, 149.6 S/cm, 500 ml (0.132 Us.gal); order no. 50081903
CLY11-C, 1.406 mS/cm, 500 ml (0.132 Us.gal); order no. 50081904
CLY11-D, 12.64 mS/cm, 500 ml (0.132 Us.gal); order no. 50081905
CLY11-E, 107.0 mS/cm, 500 ml (0.132 Us.gal); order no. 50081906
Digital sensors (additional)
Measuring cables
CYK10 Memosens data cable
For digital pH sensors with Memosens technology (CPSxxD)
Ordering according to product structure, see Technical Information (TI376C/07/en)
30
Endress+Hauser
Documentation
Operating Instructions CM42
TI381C/07/en/05.05
Printed in Germany / FM+SGML 6.0 / POD/
51517610