Nitomortar FC

constructive solutions

Epoxy resin fairing coat


Uses

Properties

For filling blowholes, and eliminating minor irregularities


prior to the application of Nitocote and Nitoflor epoxy
coatings.

The following properties were obtained at a temperature of


20oC unless otherwise specified.
Test method
Compressive strength
(BS 6319, Part 2):
Bond strength
(BS 6319, Part 2):
Pot life: 20oC
35oC
Initial cure:
o
20 C
35oC
Over-coating time:
20oC
o
35 C
Full cure:
20oC
o
35 C
Fresh wet density:

Advantages
Non-slump can be applied to vertical surfaces and
trowelled into blowholes.
Superior bond strength to virtually all substrates.
Smooth paste consistency easy to apply and finish.
Reduced usage of subsequent coating.
Pre-weighed components ensure consistency.
Description
Nitomortar FC two component thixotropic material is
based on high quality solvent-free epoxy resin systems.
The colour-coded material is supplied in pre-weighed
quantities ready for on-site mixing and use.

Typical result
2
70 N/mm at 7 days
> Cohesive Strength
concrete.
4 hours
1 hours

of

10 hours
4 hours
8 - 24 hours
4 - 18 hours
7 days
4 days
3
Approximately 1700 kg/m
(fully compacted)

Application instructions

Nitomortar FC can be applied to damp surfaces and


quickly cures to form a completely impermeable surface
ready for over-coating.

Preparation
Clean the surface and remove any dust, unsound or
contaminated material, plaster, oil, paint, grease,
corrosion deposits or algae.

Technical support

Surface should preferably be prepared using high


pressure water jetting or light abrasive blasting, followed
by thorough washing to remove dust and remaining
particles.

Fosroc offers a comprehensive range of high


performance, high quality construction products.
In
addition, Fosroc offers a technical support package to
specifiers, end-users and contractors, as well as on-site
technical assistance in locations all over the world.

Oil and grease deposits should be removed by steam


cleaning, detergent scrubbing or the use of a proprietary
degreaser. The effectiveness of decontamination should
then be assessed by a pull-off test. No independent
priming system is required.

Design criteria
Nitomortar FC can be applied in sections up to 3 mm thick
in vertical and overhead locations in a single application
without the use of formwork. Greater thicknesses than
those specified can be achieved by application of
subsequent layers. Consult the local Fosroc office for
further information. For higher build characteristics to
vertical or overhead locations.
Nitomortar HB is
recommended.

Mixing
Care should be taken to ensure that Nitomortar FC is
thoroughly mixed to produce a fully homogeneous,
trowellable mortar.
Nitomortar FC should be mixed using a slow speed drill
fitted with a suitable mixing paddle, it can also be mixed
manually for 1 kg packs.

Specification clauses
Epoxy resin-based fairing coat mortar

The hardener and base components should be mixed


thoroughly. The entire contents of the hardener should
be emptied into the base containers and the components
blended together until a uniform grey colour and
consistency is obtained. Under no circumstance should
part packs be used.

The epoxy resin-based fairing coat mortar shall be


Nitomortar FC a two-component solvent-free epoxy resin
3
mortar with a density not greater than 1700 kg/m . The
cured mortar shall achieve a compressive strength of 70
2
N/mm . The material shall be colour coded to facilitate
mixing.

Page 1

Nitomortar FC
structure which might otherwise be at risk from the
environment.

Large quantities can be mixed in suitable forced action


mixer (e.g. Cretangle or Pennine) but no more than can be
reasonably used within the pot life of the product should
be prepared at any one time.

For further advice on coatings, consult the local Fosroc


office.

Application
Cleaning
Apply the mixed Nitomortar FC to the prepared substrate
by spatula, filling knife, squeegee or steel float, tight
trowelling onto the substrate to ensure positive adhesion
and that all blow holes and defects are completely filled to
produce a smooth even finish.

Nitomortar FC should be removed from tools, equipment


and mixers with Fosroc Solvent 102 immediately after use.
Hardened material can only be removed mechanically.
Limitations

Application thickness will vary with profile and alignment of


substrate. Where necessary mortar should be built up in
layers.

Do not mix part packs under any circumstances.


Nitomortar FC should not be exposed to water during
application. Exposure to heavy rainfall prior to final set
may result in surface scour.
If any doubts arise
concerning temperature or substrate conditions, consult
the local Fosroc office. Nitomortar FC should not be used
when the temperature is below 5oC and falling.

Build-up
Additional build-up can be achieved by application of
multiple layers. Where thicker sections are required, the
surface of the intermediate applications should not be
closed, to provide a suitable surface for subsequent
layers. The application of additional layers should follows
between 8 and 24 hours at 20oC after the first application.
This time should be reduced at higher temperatures.
Application of Nitomortar FC may then proceed.

Estimating
Supply
Nitomortar FC:
Fosroc Solvent 102:

If sagging occurs during application, the Nitomortar FC


should be completely removed and re-applied at a
reduced thickness on to the substrate.

1 and 5 kg packs
4 and 25 litre cans

Coverage and yield

Finishing

Nitomortar FC:

Any ridges left by the trowel can be brushed out while the
material is still wet or ground down with a carborundum
stone before over-coating.

Storage

2
1.6 to 1.8 kg/m at 1 mm
thickness

Shelf life
Important note: Do not use solvent to thin components
as this will prevent proper cure.

Nitomortar FC has a shelf life of 12 months at 30oC if kept


in a dry store in the original, unopened bags or packs.

High temperature working


Storage conditions
o
At ambient temperature above 35 C Nitomortar FC will
have shorter pot life and working life. The materials
should be stored in the shade or in an air-conditioned
environments and should not be applied in direct sunlight.

Store in dry conditions in the original, unopened bags or


packs. If stored at high temperatures, the shelf life may
be reduced to 4 to 6 months.

Curing

Precautions

Curing protection is not necessary for Nitomortar FC.

Health and safety

Over-coating with protective/decorative finishes

Nitomortar FC and Fosroc Solvent 102 should not come in


contact with skin or eyes, or be swallowed. Ensure
adequate ventilation and avoid inhalation of vapours.
Some people are sensitive to resins, hardeners and
solvents. Wear suitable protective clothing, gloves and
eye/face protection.

Nitomortar FC can be recoated with Nitocote epoxy


coatings within a maximum interval of 24 hours.
For surrounding areas not subjected to chemical attack or
physical wear, Fosroc recommend the use of the
Dekguard range of anti-carbonation, anti-chloride
protective coatings. These products provide a decorative
and uniform appearance as well as protecting areas of the

constructive solutions

If working in confined areas, suitable respiratory protective


equipment must be used. The use of barrier creams
provides additional skin protection. Should accidental skin

Page 2

Nitomortar FC
contact occur, remove immediately with a resin removing
cream followed by washing with soap and water. Do not
use solvent. In case of contact with eyes, rinse immediately
with plenty of clean water and seek medical advice. If
swallowed, seek medical attention immediately - do not
induce vomiting.
Fire
Nitomortar FC is non-flammable. Fosroc Solvent 102 is
flammable. Keep away from sources of ignition. No
smoking. In the event of fire, extinguish with CO2 or foam.
Do not use a water jet.
Flash point
Fosroc Solvent 102:

33oC

For further information, refer to the product materials safety


data sheet.
Additional information
Fosroc manufactures a wide range of products specifically
designed for the repair and refurbishment of damaged
reinforced concrete. These include hand-placed and spray
grade repair mortars, fluid micro-concrete, chemical
resistant epoxy mortars and a comprehensive package of
protective coatings.
In addition, a wide range of complementary products is
available.
This includes joint sealants, waterproofing
membranes, grouting, anchoring and specialised flooring
materials.
Fosroc has also produced several educational training
videos that provide more details about the mechanisms that
cause corrosion within reinforced concrete structures and
the solutions that are available to arrest or retard these
destructive mechanisms.
Further information is available from the publication Repair
and Protection of Reinforced Concrete - Systematic
solutions - developed for a new era.
For further information about products, training videos or
publications, contact the local Fosroc office.

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Head Office
Post Box 11081
Jeddah 21453
Saudi Arabia

www.fosroc.com

Telephone: +966 2 637 5345

Fax: +966 2 637 5891

email: fosam@fosroc.com

Regional Offices
Jeddah Sales Office
Jeddah Showroom
Riyadh
Dammam
Khamis Mushayt

Tel: (02) 6080999


Tel: (02) 665 0787
Tel: (01) 482 9303
Tel: (03) 814 1282
Tel: (07) 250 0469

Fax: (02) 635 3330


Fax: (02) 667 4884
Fax: (01) 482 7562
Fax: (03) 814 1581
Fax: (07) 250 0469

Yanbu Tel: (04) 322 4280


Makkah Tel: (02) 542 0869
Medinah Tel: (04) 845 1767
Jubail Tel: (03) 362 3904

Fax: (04) 391 2980


Fax: (02) 542 0869
Fax: (04) 846 3195
Fax: (03) 362 3875

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407

Page 3

FO SA/NITOMORTAR FC/05/A

You might also like