Professional Documents
Culture Documents
Power Cycle Apg40c
Power Cycle Apg40c
**********************************************************************
Existing Logical Drive Information
By LSI Logic Corp.,USA
**********************************************************************
[Note: For SATA-2, 4 and 6 channel controllers, please specify
Ch=0 Id=0..15 for specifying physical drive(Ch=channel, Id=Target)]
Logical Drive : 0( Adapter: 0 ): Status: DEGRADED
--------------------------------------------------SpanDepth :01 RaidLevel: 1 RdAhead : Yes Cache: DirectIo
StripSz :064KB Stripes : 2 WrPolicy: WriteThru
2 If the faulty node (Node B) is not in shutdown or waiting to shutdown, issue the
commands on faulty node.
>> Disable startup and stop ACS_PRC_ClusterContol, FCH and FCR servers.
>> Stop cluster service.
AP Command:
sc config acs_prc_clustercontrol start= disabled && net stop acs_prc_clustercontrol
sc config acs_fch_server start= disabled && net stop acs_fch_server
sc config acs_fcr_server start= disabled && net stop acs_fcr_server
net stop /y Clussvc
3 Bring the faulty node into a safe state.
Issue the command on the active node (NODE A )
Note: Some steps in the execution of the command may be faulty. Just continue by typing "Y" at
the prompts.
AP Command:
fcc_save_to_remove other
Example Printout:
Are you sure to execute fcc_save_to_remove? [Y/N] : Y If necessary, cluster groups are moved
from the other node.
Examine cluster group "Disk Group"
Cluster group already is on the node "APG40A"
Examine cluster group "PMC860 Group"
Cluster group already is on the node "APG40A"
Examine cluster group "Cluster Group"
Cluster group already is on the node "APG40A"
Examine cluster group "RGAPM_0"
Examine cluster group "RGAPM_1"
Move the cluster groups : ok
Stop cluster service : faulty
Do you like to continue the command? [Y/N]: Y Remove the mirrors: ok Shutdown the other
node : faulty Do you like to continue the command? [Y/N]: Y Turn off the other node :ok
fcc_save_to_remove was not executed correctly
4 The MIA light should be lit on the faulty node.
If the MIA light is lit, disconnect power from the faulty node(Node B), wait 60 seconds, then
reconnect the power.
5 Wait about 10 minutes for the node to reboot.
6 Stop and disable ACS_FCH_Server on Active node (node A)