Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

POWER CYCLE APG40C/4

Prepare : 1 VGA Monitor,1 keyboard, Power, Torx #8


0 Check both node (before)
prcstate -l
cluster node
cluster res
cluster group
alist
megarc -dispCfg -a0
1 Check the status of the data disk drives on the working node (active node).
Make sure all disk drives on bus 1 (Chnl 1 - Node A ) have the status "Online".
AP Command:
megarc -dispCfg -a0
C:\>megarc -dispCfg -a0
**********************************************************************
MEGARC MegaRAID Configuration Utility(NT)-1.14_Wrap1.0.3(2-17-2006)
By LSI Logic Corp.,USA
**********************************************************************
[Note: For SATA-2, 4 and 6 channel controllers, please specify
Ch=0 Id=0..15 for specifying physical drive(Ch=channel, Id=Target)]
Type ? as command line arg for help
Finding Devices On Each MegaRAID Adapter...
Scanning Ha 0, Chnl 0 Target 00
Scanning Ha 0, Chnl 0 Target 01
Scanning Ha 0, Chnl 0 Target 02
Scanning Ha 0, Chnl 0
Target 03
Sc
anning Ha 0, Chnl 0 Target 04
Scanning Ha 0, Chnl 0 Target 05
Scanning Ha 0, Chnl 0 Target 06
Scanning Ha 0, Chnl 0 Target
07
Scanning Ha
0, Chnl 0 Target 08
Scanning Ha 0, Chnl 0 Target 09
Scanning Ha 0, Chnl 0 Target 10
Scanning Ha 0, Chnl 0 Target 11
Scanning Ha 0, Chnl 0
Target 12
Scanning Ha 0, Chnl 0 Target 13
Scanning Ha 0, Chnl 0 Target 14
Scanning Ha 0, Chnl 0 Target 15
Scanning Ha 0,
Chnl 1 Target 00
Scanning Ha 0, Chnl 1 Target 01
Scanning Ha 0, Chnl 1 Target 02
Scanning Ha 0, Chnl 1 Target 03
Scanning Ha 0, Chnl 1
Target 04
Sc
anning Ha 0, Chnl 1 Target 05
Scanning Ha 0, Chnl 1 Target 06
Scanning Ha 0, Chnl 1 Target 07
Scanning Ha 0, Chnl 1 Target
08
Scanning Ha
0, Chnl 1 Target 09
Scanning Ha 0, Chnl 1 Target 10
Scanning Ha 0, Chnl 1 Target 11
Scanning Ha 0, Chnl 1 Target 12
Scanning Ha 0, Chnl 1
Target 13
Scanning Ha 0, Chnl 1 Target 14
Scanning Ha 0, Chnl 1 Target 15

**********************************************************************
Existing Logical Drive Information
By LSI Logic Corp.,USA
**********************************************************************
[Note: For SATA-2, 4 and 6 channel controllers, please specify
Ch=0 Id=0..15 for specifying physical drive(Ch=channel, Id=Target)]
Logical Drive : 0( Adapter: 0 ): Status: DEGRADED
--------------------------------------------------SpanDepth :01 RaidLevel: 1 RdAhead : Yes Cache: DirectIo
StripSz :064KB Stripes : 2 WrPolicy: WriteThru

Logical Drive 0 : SpanLevel_0 Disks


Chnl Target StartBlock Blocks
Physical Target Status
---- ------ ---------- ------ ---------------------0
00 0x00000000 0x04471000 FAILED
1
00 0x00000000 0x04471000 ONLINE
**********************************************************************
Existing Logical Drive Information
By LSI Logic Corp.,USA
**********************************************************************
[Note: For SATA-2, 4 and 6 channel controllers, please specify
Ch=0 Id=0..15 for specifying physical drive(Ch=channel, Id=Target)]
Logical Drive : 1( Adapter: 0 ): Status: OPTIMAL
--------------------------------------------------SpanDepth :01 RaidLevel: 1 RdAhead : Yes Cache: DirectIo
StripSz :064KB Stripes : 2 WrPolicy: WriteThru
Logical Drive 1 : SpanLevel_0 Disks
Chnl Target StartBlock Blocks
Physical Target Status
---- ------ ---------- ------ ---------------------0
01 0x00000000 0x04471000 ONLINE
1
01 0x00000000 0x04471000 ONLINE
**********************************************************************
Existing Logical Drive Information
By LSI Logic Corp.,USA
**********************************************************************
[Note: For SATA-2, 4 and 6 channel controllers, please specify
Ch=0 Id=0..15 for specifying physical drive(Ch=channel, Id=Target)]
Logical Drive : 2( Adapter: 0 ): Status: OPTIMAL
--------------------------------------------------SpanDepth :01 RaidLevel: 1 RdAhead : Yes Cache: DirectIo
StripSz :064KB Stripes : 2 WrPolicy: WriteThru
Logical Drive 2 : SpanLevel_0 Disks
Chnl Target StartBlock Blocks
Physical Target Status
---- ------ ---------- ------ ---------------------0
02 0x00000000 0x04471000 ONLINE
1
02 0x00000000 0x04471000 ONLINE
Exiting with 0
C:\>

2 If the faulty node (Node B) is not in shutdown or waiting to shutdown, issue the
commands on faulty node.
>> Disable startup and stop ACS_PRC_ClusterContol, FCH and FCR servers.
>> Stop cluster service.

AP Command:
sc config acs_prc_clustercontrol start= disabled && net stop acs_prc_clustercontrol
sc config acs_fch_server start= disabled && net stop acs_fch_server
sc config acs_fcr_server start= disabled && net stop acs_fcr_server
net stop /y Clussvc
3 Bring the faulty node into a safe state.
Issue the command on the active node (NODE A )
Note: Some steps in the execution of the command may be faulty. Just continue by typing "Y" at
the prompts.
AP Command:
fcc_save_to_remove other
Example Printout:
Are you sure to execute fcc_save_to_remove? [Y/N] : Y If necessary, cluster groups are moved
from the other node.
Examine cluster group "Disk Group"
Cluster group already is on the node "APG40A"
Examine cluster group "PMC860 Group"
Cluster group already is on the node "APG40A"
Examine cluster group "Cluster Group"
Cluster group already is on the node "APG40A"
Examine cluster group "RGAPM_0"
Examine cluster group "RGAPM_1"
Move the cluster groups : ok
Stop cluster service : faulty
Do you like to continue the command? [Y/N]: Y Remove the mirrors: ok Shutdown the other
node : faulty Do you like to continue the command? [Y/N]: Y Turn off the other node :ok
fcc_save_to_remove was not executed correctly
4 The MIA light should be lit on the faulty node.
If the MIA light is lit, disconnect power from the faulty node(Node B), wait 60 seconds, then
reconnect the power.
5 Wait about 10 minutes for the node to reboot.
6 Stop and disable ACS_FCH_Server on Active node (node A)

sc config acs_fch_server start= disabled && net stop acs_fch_server


7 Integrate the shared mirrored disk drive from the active node.
Issue the command on the active node (node A)
Note: Some steps may be faulty. Just continue by typing "Y" at the prompts.
AP Command:
fcc_integrate other
Example Printout:
Are you sure to execute fcc_integrate? [Y/N] : Y Examines, whether the other
node has started!
The name of the other node = APG40B
The other node is accessible
Stop the cluster service on the other node: faulty Do you like to continue the command? [Y/N]:
Y Initialize the rebuilding of the mirrors: ok Start the cluster service on the other node: ok
fcc_integrate was not executed correctly
8 Check that the mirroring of the RAIDs is ongoing.
megarc -dispCfg -a0
The mirroring process will take 1-2 hours Wait until process is complete
9 Enable and start ACS_FCH_Server on Active node (node A)
sc config acs_fch_server start= auto && net start acs_fch_server
10 Check node passive (node B)
fchstate -q clussvc
fchstate -q acs_fch_server
fchstate -q acs_prc_clustercontrol
If not start :
net start clussvc
sc config acs_prc_clustercontrol start= auto && net start acs_prc_clustercontrol
sc config acs_fch_server start= auto && net start acs_fch_server
11 Check both node (after)