Professional Documents
Culture Documents
LTE Parameter Setting Exercises
LTE Parameter Setting Exercises
IDLE Mode
Initial Cell Selection
1)
Based on the following measurements and thresholds, calculate the Srxlev for each
cell and determine which cell will be initially selected by the mobile.
Qrxlevmin; -75dBm
Qrxlevmeas_A; -65dBm
A
Qrxlevmin; -95dBm
Qrxlevmeas_B; -75dBm
C
Qrxlevmin; -95dBm
Qrxlevmeas_C -100dBm
Srxlev_A ____________________
Srxlev_B_____________________
Srxlev_C_____________________
2)
Determine from the following, at what Qrxlev_meas,S would intra-freq search and
non-intra-freq search begin
Srxlev
Qrxlevmin = -90dBm
Sintrasearch = 30
Snonintrasearch = 10
3)
From the following parameters determine what value Qrxlevmin should be set to, if
the intra-frequency search is required to begin at -50dBm
Sintrasearch = 20dB
Qrxlevmeas = -50
Srxlev = Qrxlevmeas,s Qrxlevmin
Qrxlevmin_____________________________________________
4)
Assuming Qhyst = 5 and Qoffset = -3, plot the line of Rs and Rn on the graph below.
Rs = Qmeas,s + Qhyst
Rn = Qmeas,n + Qoffset
Indicate the point on the graph at which cell reselection will take place
30
35
40
45
dBm
50
55
60
65
70
75
80
85
What is the actual value of Qmeas,s and Qmeas,n for the serving and neighbor cells when
the reselection actually takes place?
Qmeas,s________________________________
Qmeas,n________________________________
5)
Discuss the impact on the idle mode mobility of the UE if the Qhyst was set to 10dB__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
6)
If no LTE neighbour was available and the Snonintrasearch threshold was set to
10dB what would Qmeas (signal strength) when the UE began searching for an IRAT
neighbour?
__________________________________________________________________________
__________________________________________________________________________
Value
Parameter
Value
s-Measure
95 dBm
A3-Offset
6 dB
triggerQuantity
RSRP
reportOnLeave
True
reportQuantity
Both
hysteresis
2 dB
maxReportCells
timeToTrigger
640 ms
reportInterval
480 ms
threshold1-RSRP
104 dBm
reportAmount
threshold2-RSRP
98 dBm
hysteresis
2 dB
timeToTrigger
640 ms
speedStateParameters
eA3
eA5
Cell are placed along the new rail line approximately every five kilometres. It is expected that
on open track the overlap area between cells will be in the order of 1 km, however, in some
places, particularly at tunnel entrances it may be as low as 200 m.
The normal operating speed for the trains is 500 km/h.
Step 1
Calculate how long it will take a train running at normal operating speed to pass through the
overlap area between cells. You should do this for both open ground and tunnel entrances.
Answer:
Step 2
Write a brief report indicating whether or not you think changes need to be made to the
standard parameter set. Include a brief explanation of each change and consider any other
changes that you think might be appropriate outside the set of parameters given here.