Shows the T-s diagram for the ideal cogeneration power plant as in Figure (1).
For the cogeneration power plant, the process parameters such as pressure, specific
i th
enthalpy, specific entropy, specific volume, mass flow rate, and temperature at
state be
&
Pi hi si vi mi
Ti
, , , , , and .
Express the specific work input of pump I to the system.
wpI,in v1 P2 P1
(1)
h1
Refer to saturated water-pressure table, and interpret the values of
P1 10 kPa
pressure
.
h1 h f 191.81 kJ kg
v1
, and
v1 v f 0.00101 m3 kg
v1 10 kPa
P1
P2
1, 200 kPa
for ,
for , and
for
in Equation (1).
1 kJ
0.00101m3 kg 1, 200 10 kPa
3
1 kPa m
0.00101 m 3 kg
Substitute
wpI,in
1.20 kJ kg
h1
wpI,in
1.20 kJ kg
Substitute
for , and
h2 191.81 kJ kg 1.20 kJ kg
for
in Equation (2).
193.01 kJ kg
m&2 h2 m&3 h3
m&4
(4)
at
h3
Refer to saturated water-pressure table, and interpret the value of
P3 1.2 MPa
.
h3 h f 798.33 kJ kg
193.01 kJ kg
at pressure
h2 798.33 kJ kg
h3 22.50 kg s
m&2 7.50 kg s
for ,
for ,
for
,
for
Substitute
m&3
m&4
30 kg s
, and
for
in Equation (4).
22.50 193.01 7.50 798.33
h4
30
344.34 kJ kg
h4 344.34 kJ
v4
Refer to saturated steam table, and interpret
v4 v f 0.001031 m3 kg
0.001031 m3 kg
Substitute
(5).
kg
at enthalpy
v3 4, 000 kPa
P5
P4
1, 200 kPa
for ,
for , and
for
in Equation
1 kJ
3
1 kPa m
h4
344.34 kJ kg
wpII,in
2.89 kJ kg
Substitute
for , and
h5 344.34 kJ kg 2.89 kJ kg
for
in Equation (6).
347.23 kJ kg
h6
Refer to superheated water table, and interpret the values of
P6 4 MPa
T6 500C
, and temperature
.
h6 3,446 kJ kg
s6
, and
at pressure
s6 7.0922 kJ kg K
s6 s7
Since
7.0922 kJ kg K
s7
, the entropy value of
is
P7 1.2 MPa
h7
x1 x0 y1 y0
(8)
y0
y1
x0
x1
, and 3154.2 for
in
h7 3,080.4 kJ kg
Hence,
s6 s8
Since
7.0922 kJ kg K
s8
, the specific entropy value of
sf
Interpret the value of
table.
P8 10 kPa
s fg
and
is
at pressure
s f 0.6492 kJ kg K
s fg 7.4996 kJ kg K
7.0922 kJ kg K
sf
s fg
s8 0.6492 kJ kg K
7.4996 kJ kg K
for ,
for , and
for
Substitute
in Equation (5).
7.0922 0.6492
x8
7.4996
0.8591
hf
Refer to saturated water-pressure table, and interpret the values of
P8 10 kPa
.
h f 191.81 kJ kg
h fg
and
at
h fg 2,392.1 kJ kg
hf
191.81 kJ kg
h fg
2,392.1 kJ kg
Substitute
for
,
for
(9).
h8 191.81 kJ kg 0.8591 2,392.1 kJ kg
x8
in Equation
2, 246.85 kJ kg
h6 3, 080.4 kJ kg
h7 2, 246.85 kJ kg
h8 55 kg s
Substitute
for ,
for ,
for ,
&
m&6
m
0.75 55 kg s
8
for
, and
for
in Equation (10).
&
WT,out 55 kg s 3, 446 3, 080.4 0.75 55 kg s 3, 080.4 2, 246.85
3, 446 kJ kg
54, 492 kW
Express the total power input to the cycle.
W&p,in m&1wpI,in m&4 wpII,in
(11)
0.75 55 kg s
wpI,in
m&1 55 kg s
m&4 1.20 kJ kg
2.89 kJ kg
for
,
for
,
for
, and
Substitute
wpII,in
for
in Equation (11).
&
Wp,in 0.75 55 kg s 1.20 kJ kg 55 kg s 2.89 kJ kg
208.45 kW
208.45 kW
W&p,in
W&T,out
54, 492 kW
Substitute
for
, and
&
Wnet 54, 492 208.45
for
in Equation (12).
54, 284 kW
54, 284 kW
Therefore, the net power output of the cycle is
m&4 3, 080.4 kJ kg
h7
h3
798.33 kJ kg
for
,
for
, and
for
in
Substitute
Equation (13).
Q&process 0.25 55 3, 080 798.33
31,379 kW
m&5 3, 446 kJ kg
h6
h5
347.23 kJ kg
for
,
for , and
for
in Equation
55 kg s
Substitute
(14).
Q&in 55 3, 446 347.23
170, 433 kW
(15)
170, 433 kW
Substitute
for
Equation (15).
54, 284 31,379
u
170, 433
50.26 %
Q&in
Q&process
31,379 kW
,
for
W&net
54, 284 kW
, and
for
50.26 %
Therefore, the utilization factor of the cogeneration plant is
in