1 Identification
2 Introduction
FANT-F AC
2
2
5 Functional Description
6 External Interfaces
8 Physical Description
9 Power Supply
10
12
Released
1 / 12
FANT-F AC
1
FX NT Unit version F
Identification
Table 1 provides identification of the FANT-F AC.
Table 1: Identification of the FANT-F AC
Part Number
Mnemonic
Name
3FE 53701 AC
FANT-F AC
Introduction
This document describes the Combined NT Unit version F (FANT-F) which is part of the
7360 Intelligent Services Access Manager (7360 ISAM) FX.
the client devices mounted in the subrack or connected to the subrack, and supports
the management and control interfaces required for this task.
Has four SFP+ 10Gigabit Ethernet (10GE) interfaces
The SFP+ interfaces support 1 GE and 10 GE data rates.
Has one 10/100/1000BASE-T interface
Supports NT I/O.
Supports:
Supports synchronous Ethernet link data clock extraction for Network Timing
Reference (NTR) use:
Released
2 / 12
FX NT Unit version F
FANT-F AC
Is hot-swappable
Consists of components which are compliant to the regulations of Reduction of
Hazardous Substances (RoHS) and Waste Electrical and Electronic Equipment
(WEEE).
Is compliant to safety standards IEC / EN 60950-1 and AS/NZS 60950-1, provided
that it is installed, maintained and used according the relevant installation
instructions.
General Description
The FANT-F AC NT board is responsible for:
the routing/switching and the aggregation of end-user data streams to and from
The LT boards are responsible for the physical termination of user interfaces and nonblocking user aggregation.
The FANT-F AC board must be used at the NT-A and/or the NT-B position of the 7360
ISAM FX subrack. Figure 1 shows the position of the FANT-F in the ISAM system.
Fig. 1: Position of the FANT-F AC in the system
Management-A
interface
LT #0
LT #1
Uplink/Network
Interfaces
NT-A
(FANT-F)
NTIO
A
Power unit
Alarm IO board
NTIO
B
LT #N-1
NT-B
(FANT-F)
LT #N
Management-B
interface
ISAM system
Released
3 / 12
FANT-F AC
5
FX NT Unit version F
Functional Description
Figure 2 shows the different functional blocks of the FANT-F AC.
Fig. 2: Functional Blocks of the FANT-F AC
PBA-FANT-F
BITS-Interface
ToD and 1PPS interface
8kHz-Interface
19.44MHz-Interface
10MHz GPS Interface
FIM
BIM
REFIN
REFOUT
REFIN
MCSD
REFOUT
PNTIN
NT Front SystemLEDs
Local Craft Interface
CISC
NT Alarm-Cut-Off LED
NT Alarm-Cut-Off-Switch
ACOLED
ACOSW
FUI#0
FUI#4
NT Reference Clock
NT ToD/1PPS
LT Reference Clocks
Peer NT Reference Input Clock
Peer NT ToD/1PPS
LCMI
RCMI
SAI
LT1
LT2
LT SerdesItf#1
LT SerdesItf#2
LT16
BUI0
BUI1
BUI7
HIPC
SOI
SLI
SIO
SAS
BSM
SYSLED
LCMI
BITS Interface
ToD and 1Hz Interface
ACU
NUTS
UPLED
NNLS
LT SerdesItf#16
PSIM
CISC:
The Centralized ISAM System Controller (CISC) Implements all On-Board
Controller (OBC) functions which accommodate a centralized Control and
Management approach of the complete ISAM shelf and provides the necessary
processing capabilities for Ethernet packets/frames forwarded to the main OBC from
the GE switching module.
Released
4 / 12
FX NT Unit version F
FANT-F AC
MCSD:
The Master Clock Synchronization and Distribution (MSCD) provides the following
functionality:
NUTS:
The Network/User Transport and Switching (NUTS) provides the interface and
switching circuitry for the front and back related uplink/network interfaces to/from
the LT slots.
PSIM:
The Power Supply Interface Module (PSIM) converts the rack power supply into all
necessary voltages as required by the used components.
FIM:
The Frontplate Interface Module (FIM) located at the front stiffener holds the
physical interfaces (four SFP+, one 10/100/1000Base-T interface) together with a
visual port status indication. The FIM also hosts a Management Interface (CRAFT)
together with the ACO functionality.
BIM:
The Backplane Interface Module (BIM) constitutes all the necessary control,
management, and data plane related interface inside the complete ISAM system.
Released
5 / 12
FANT-F AC
6
FX NT Unit version F
External Interfaces
The following external interfaces are accessible via the front panel:
Communication Interfaces
5 communication interfaces are available via the front panel:
Management Interfaces
The following management interfaces are available via the front panel:
Description
Type
Pin Nr.
Technology
LCMI_RI_DSR
Local-Craft-Mgt-Itf Data-Set-Ready
EIA/TIA-562
LCMI_DCD
Local-Craft-Mgt-Itf Data-Carrier-Detect
EIA/TIA-562
LCMI_DTR
Local-Craft-Mgt-Itf Data-Terminal-Ready
EIA/TIA-562
EG
Ref
Ref
LCMI_RXD
EIA/TIA-562
LCMI_TXD
EIA/TIA-562
(1 of 2)
Released
6 / 12
FX NT Unit version F
FANT-F AC
Signal Name
Description
Type
Pin Nr.
Technology
LCMI_CTS
Local-Craft-Mgt-Itf Clear-To-Send
EIA/TIA-562
LCMI_RTS
Local-Craft-Mgt-Itf Request-To-Send
EIA/TIA-562
(2 of 2)
BITS Interface
The BITS/DC IN/OUT interfaces are mapped to two physical RJ45 connectors.
Fig. 3: RJ45 Connector
Description
Type
RJ45 Pin
2, 3
Ref
1, 4 & CASE
Frame Ground
Description
Type
RJ45 Pin
BITS-OUT_T/R
2, 3
5, 6
7, 8
Ref
DC-OUT-19K_T/F
FG_ESD_EMC
Frame Ground
Released
7 / 12
FANT-F AC
FX NT Unit version F
The FANT-F provides a Time of Day (ToD) port on its frontplate. This interface consists
of differential ToD and 1PPS signals (RS-422 technology), mapped on a RJ45 connector.
Table 5 shows the signals of the ToD interface.
Table 5: TOD/1PPS-Interface Signal-List of the Frontplate
Signals
Description
ToD_UART_T/F
ToD UART TX, PTP Master mode (differential pair, 100 ohm)
ToD UART RX, PTP Slave mode (differential pair, 100 ohm)
ToD_1PPS_T/F
Type
RJ45 Pin
8, 7
6, 3
EG
Electrical Ground
REF
4, 5
FG
Frame Ground
REF
CASE
NC
Not Connected
1, 2
Table 6 shows the signals of the 1PPS interface on the SMA connector.
Table 6: 1PPS Interface on the SMA connector: Signal-List
Signals
Description
1PPS-TTL
TTL
TTL
Frame ground
Ref.
Shield
Type
Technology
Table 7 shows the signals of the 10MHz GPS interface on the SMA connector.
Table 7: 10MHz GPS interface on the SMA connector: Signal-List
Signals
Description
10M_GPS-IN
2 to 5 Vpp
Shield
Frame ground
Ref.
Type
Released
Technology
8 / 12
FX NT Unit version F
7
FANT-F AC
Fan unit alarm interface. The alarm interface uses the GFC as an alarm handle. The
FANT-F reads and writes alarms through I2C and SPI interfaces.
Central Office alarm interface
Circuit breaker alarm
Door alarm
Subrack alarm lamp interface
Miscellaneous output alarm
These ACU interfaces can be found on the backplane of the subrack, for more
information refer to the 7360 ISAM FX Hardware Installation Manual.
Released
9 / 12
FANT-F AC
8
FX NT Unit version F
Physical Description
Figure 4 shows the side and front view of the FANT-F.
Fig. 4: View of the FANT-F AC
LEDs
SFP cages
1PPS Signal
10MHz Signal
Front Uplink Interface
CRAFT Interface
Time of Day
BITS in
BITS out
Released
10 / 12
FX NT Unit version F
FANT-F AC
Dimensions:
The dimensions of the FANT-F AC are:
ALM
PWR
ACO
A/S
FSM2
FSM1
FSM4
FSM3
Table 8 gives the definitions of the system status LEDS on the FANT-F.
Table 8: System Status LED Definition
Port
Description
PWR
A/S
ALM
ACO
FSM1
FSM2
FSM3
FSM4
Released
11 / 12
FANT-F AC
9
FX NT Unit version F
Power Supply
The FANT-F is compatible with -48 Vdc nominal and -60 Vdc nominal power supply
systems.
Note: Country dependent tolerances exist regarding the nominal battery voltage values.
Released
12 / 12