Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Combined NT Unit version F

1 Identification
2 Introduction

FANT-F AD

-2
-2

3 Features and Application Notes


4 General Description

-3

5 Functional Description
6 External Interfaces

-6

7 Alarm Control Unit

-9

8 Physical Description
9 Power Supply

3FE 53701 ADAA TQZZA Ed 01

-2

-4

-10

-12

Released

1 / 12

FANT-F AD
1

Combined NT Unit version F

Identification
Table 1 provides identification of the FANT-F AD
Table 1: Identification of the FANT-F AD

Part Number

Mnemonic

Name

3FE 53701 AD

FANT-F AD

Combined NT Unit version F

Introduction
This document describes the Combined NT Unit version F (FANT-F) which is part of the
7360 Intelligent Services Access Manager (7360 ISAM) FX.

Features and Application Notes


The FANT-F AD:

Is an NT board with a 480 Gbps switch


Can be used in a 7360 ISAM FX subrack.
Performs all management and alarm handling functions for the ISAM subrack and all

the client devices mounted in the subrack or connected to the subrack, and supports
the management and control interfaces required for this task.
Has four SFP+ 10Gigabit Ethernet (10GE) interfaces
The SFP+ interfaces support 1 GE and 10 GE data rates.
Has one 10/100/1000BASE-T interface
Supports NT I/O.
Supports:

Building Integrated Timing Source (BITS)


Synchronized Ethernet (SyncE)
External NTR Daisy-Chain output interface: 8KHz and 19.44MHz
Precision Time Protocol (PTP) IEEE 1588v2
1 Pulse Per Second (PPS) and related Time of Day (ToD) functionality
Note: SW support of ToD is not yet available in the current release

Supports synchronous Ethernet link data clock extraction for Network Timing
Reference (NTR) use:

from the SFP+ interfaces on its own front plate


from two 1 GE or 10 GE interfaces on the NTIO board

3FE 53701 ADAA TQZZA Ed 01

Released

2 / 12

Combined NT Unit version F

FANT-F AD

Can be used in the following operational conditions:


in Central Office (CO) environment with multiple 7360 ISAM FX subracks (as

described in the 7360 ISAM FX Hardware Installation Manual), the ambient


temperature can be between -5C to +45C
in a single 7360 ISAM FX subrack, the ambient temperature can be between -40C to
+70C

Is hot-swappable
Consists of components which are compliant to the regulations of Reduction of
Hazardous Substances (RoHS) and Waste Electrical and Electronic Equipment
(WEEE).
Is compliant to safety standards IEC / EN 60950-1 and AS/NZS 60950-1, provided
that it is installed, maintained and used according the relevant installation
instructions.

General Description
The FANT-F AD NT board is responsible for:

the routing/switching and the aggregation of end-user data streams to and from

network interfaces and/or uplink interfaces.


Centralized shelf control and management
System clock generation
Network Timing Reference (NTR) generation, Synchronous Equipment Timing
Source (SETS).
Centralized shelf alarm handling and reporting (Alarm Control Unit (ACU)
functionality).

The LT boards are responsible for the physical termination of user interfaces and nonblocking user aggregation.
The FANT-F AD board must be used at the NT-A and/or the NT-B position of the 7360
ISAM FX subrack. Figure 1 shows the position of the FANT-F in the ISAM system.
Fig. 1: Position of the FANT-F AD in the system
Management-A
interface

LT #0
LT #1

Uplink/Network
Interfaces

NT-A
(FANT-F)
NTIO
A

Power unit
Alarm IO board

NTIO
B

LT #N-1
NT-B
(FANT-F)

LT #N

Management-B
interface

3FE 53701 ADAA TQZZA Ed 01

ISAM system

Released

3 / 12

FANT-F AD
5

Combined NT Unit version F

Functional Description
Figure 2 shows the different functional blocks of the FANT-F AD.
Fig. 2: Functional Blocks of the FANT-F AD
PBA-FANT-F
BITS-Interface
ToD and 1PPS interface
8kHz-Interface
19.44MHz-Interface
10MHz GPS Interface

FIM

BIM

REFIN
REFOUT

REFIN
MCSD

REFOUT
PNTIN

NT Front SystemLEDs
Local Craft Interface

CISC

NT Alarm-Cut-Off LED
NT Alarm-Cut-Off-Switch

ACOLED
ACOSW

NT Front Uplink Interface #0

FUI#0

NT Front Uplink Interface #4

FUI#4

NT Front Uplink LEDs

NT Reference Clock
NT ToD/1PPS
LT Reference Clocks
Peer NT Reference Input Clock
Peer NT ToD/1PPS

LCMI
RCMI
SAI

NT-NT Communication Itf


NT-NT Switch-Over Itf
NT Special Lines Itf
NT Serial I/O Itf
NT Active-Standby Itf
NT Backplane (NTIO)
Serial Management Itf
Local Craft Interface
Remote Craft Interface
Serial Alarm Interface

LT1
LT2

LT SerdesItf#1
LT SerdesItf#2

LT16
BUI0
BUI1

Backplane Uplink Itf#0


Backplane Uplink Itf#4

BUI7

Backplane Uplink Itf#7

HIPC
SOI
SLI
SIO
SAS
BSM

SYSLED
LCMI

BITS Interface
ToD and 1Hz Interface

ACU

NUTS

UPLED

NNLS

LT SerdesItf#16

NT-NT LoasSharing Itf


NTIO/NTAP-Powering Itf
NT Power Supply Itf
SMAS-Powering Itf

PSIM

The different functional blocks are:

CISC:
The Centralized ISAM System Controller (CISC) Implements all On-Board
Controller (OBC) functions which accommodate a centralized Control and
Management approach of the complete ISAM shelf and provides the necessary
processing capabilities for Ethernet packets/frames forwarded to the main OBC from
the GE switching module.

3FE 53701 ADAA TQZZA Ed 01

Released

4 / 12

Combined NT Unit version F

FANT-F AD

MCSD:
The Master Clock Synchronization and Distribution (MSCD) provides the following
functionality:

System Network Timing Reference (NTR)


Synchronization Input references from BITS/SSU, Synchronous Ethernet input link
data clocks, IEEE-1588 ordinary or boundary clock.

Synchronization Output reference clocks towards:

- The shelf-based LT boards (backplane connections): 8 kHz.


- The internal NTR signal from the active NT board to the standby NT board in
a redundant NT board pair (backplane connection): 8 kHz.
- The external NTR daisy-chain interface (located at the NT board front): 8 kHz and
19MHz.
- The external BITS/SSU out interface (located at the NT board front):
independently configurable to 2048 kHz, E1 or DS1 signal.
Performance for SSU / BITS input/output: compliance with ITU-T G.813 Option 1:
ETSI.
Performance for Synchronous Ethernet (SyncE) input/output: compliance with ITU-T
G.8262 Option 1: ETSI

NUTS:
The Network/User Transport and Switching (NUTS) provides the interface and
switching circuitry for the front and back related uplink/network interfaces to/from
the LT slots.
PSIM:
The Power Supply Interface Module (PSIM) converts the rack power supply into all
necessary voltages as required by the used components.
FIM:
The Frontplate Interface Module (FIM) located at the front stiffener holds the
physical interfaces (four SFP+, one 10/100/1000Base-T interface) together with a
visual port status indication. The FIM also hosts a Management Interface (CRAFT)
together with the ACO functionality.
BIM:
The Backplane Interface Module (BIM) constitutes all the necessary control,
management, and data plane related interface inside the complete ISAM system.

3FE 53701 ADAA TQZZA Ed 01

Released

5 / 12

FANT-F AD
6

Combined NT Unit version F

External Interfaces
The following external interfaces are accessible via the front panel:

Communication Interfaces
5 communication interfaces are available via the front panel:

1 x fixed 10/100/1000BaseT port:


This port can work both in 10Mbit, 100Mbit or 1GE mode.
4 x 10GE SFP+ port:
This port can work both in 1 GE mode (with standard SFP optics) and in 10 GE mode
(with SFP+ optics).

Management Interfaces
The following management interfaces are available via the front panel:

Local Craft Management interface (LCMI) (RJ45 connector)


An Alarm Cut-Off Switch (ACOS) and LED (ACOLED)
Note: any of the five communication interfaces can also be used as management interface.
The following clock interfaces are available via the front panel:

BITS input interface (RJ45 connector)


BITS output interface (RJ45 connector)
Time of Day (ToD) interface
10MHz GPS interface (SMA connector)
1pps interface (SMA connector)
Daisy-Chain NTR clock output interface (RJ45 connector)

Local Craft Interface

Table 2 shows the signal list and connector pinning (RJ45)


Table 2: Local Craft Interface Pinning
Signal Name

Description

Type

Pin Nr.

Technology

LCMI_RI_DSR

Local-Craft-Mgt-Itf Data-Set-Ready

EIA/TIA-562

LCMI_DCD

Local-Craft-Mgt-Itf Data-Carrier-Detect

EIA/TIA-562

LCMI_DTR

Local-Craft-Mgt-Itf Data-Terminal-Ready

EIA/TIA-562

EG

Electrical Ground or Signal Ground

Ref

Ref

LCMI_RXD

Local-Craft-Mgt-Itf related serial Receive-Data

EIA/TIA-562

LCMI_TXD

Local-Craft-Mgt-Itf related serial Transmit-Data

EIA/TIA-562

(1 of 2)

3FE 53701 ADAA TQZZA Ed 01

Released

6 / 12

Combined NT Unit version F

FANT-F AD

Signal Name

Description

Type

Pin Nr.

Technology

LCMI_CTS

Local-Craft-Mgt-Itf Clear-To-Send

EIA/TIA-562

LCMI_RTS

Local-Craft-Mgt-Itf Request-To-Send

EIA/TIA-562

(2 of 2)

BITS Interface

The BITS/DC IN/OUT interfaces are mapped to two physical RJ45 connectors.
Fig. 3: RJ45 Connector

Table 3 shows the signals of the BITS-/DC IN connector.


Table 3: BITS/DC IN Signals
Signal Name
BITS-IN_T/R

Description

Type

RJ45 Pin

BITS Network Timing-Reference

2, 3

Ref

1, 4 & CASE

(Tip line and Ring line are a differential pair of 120 )


FG_ESD_EMC

Frame Ground

Table 4 shows the signals of the BITS-/DC OUT connector.


Table 4: BITS/DC OUT Signals
Signal Name

Description

Type

RJ45 Pin

BITS-OUT_T/R

BITS-OUT / BITS Cut-through Network Timing-Reference

2, 3

5, 6

7, 8

Ref

1,4 & CASE

(Tip line and Ring line are a differential pair of 120 )


DC-OUT-8k_T/F

Daisy-Chain 8KHz Timing Reference Output Clock


Differential pair 100 LVPECL

DC-OUT-19K_T/F

Daisy-Chain 19.44MHz Timing Reference Output Clock


Differential Pair 100 , LVPECL

FG_ESD_EMC

3FE 53701 ADAA TQZZA Ed 01

Frame Ground

Released

7 / 12

FANT-F AD

Combined NT Unit version F

ToD and 1Hz Validation Pulse Input Interface

The FANT-F provides a Time of Day (ToD) port on its frontplate. This interface consists
of differential ToD and 1PPS signals (RS-422 technology), mapped on a RJ45 connector.
Table 5 shows the signals of the ToD interface.
Table 5: TOD/1PPS-Interface Signal-List of the Frontplate
Signals

Description

ToD_UART_T/F

ToD UART TX, PTP Master mode (differential pair, 100 ohm)

ToD UART RX, PTP Slave mode (differential pair, 100 ohm)

1PPS output, PTP Master mode (differential pair, 100 ohm)

1PPS input, PTP Slave mode (differential pair, 100 ohm)

ToD_1PPS_T/F

Type

RJ45 Pin
8, 7

6, 3

EG

Electrical Ground

REF

4, 5

FG

Frame Ground

REF

CASE

NC

Not Connected

1, 2

1PPS interface on the SMA connector

Table 6 shows the signals of the 1PPS interface on the SMA connector.
Table 6: 1PPS Interface on the SMA connector: Signal-List
Signals

Description

1PPS-TTL

1PPS output, PTP Slave mode (single-ended, 50 ohm)

TTL

1PPS input, PTP Master mode (single-ended, 50 ohm)

TTL

Frame ground

Ref.

Shield

Type

Technology

10MHz GPS interface on the SMA connector

Table 7 shows the signals of the 10MHz GPS interface on the SMA connector.
Table 7: 10MHz GPS interface on the SMA connector: Signal-List
Signals

Description

10M_GPS-IN

10 MHz GPS Timing Reference (sinewave, 50 ohm,


transformer coupled)

2 to 5 Vpp

Shield

Frame ground

Ref.

3FE 53701 ADAA TQZZA Ed 01

Type

Released

Technology

8 / 12

Combined NT Unit version F


7

FANT-F AD

Alarm Control Unit


The Alarm Control Unit (ACU) provides:

a central point for internal (= subrack-related) alarm collection.


a central point for external (= CO-related) alarm collection and control.
the necessary circuitry for rack alarm control and visualization.
an Alarm Cut Off (ACO) capability to the subrack.

The following ACU functionality is provided:

Fan unit alarm interface. The alarm interface uses the GFC as an alarm handle. The

FANT-F reads and writes alarms through I2C and SPI interfaces.
Central Office alarm interface
Circuit breaker alarm
Door alarm
Subrack alarm lamp interface
Miscellaneous output alarm

These ACU interfaces can be found on the backplane of the subrack, for more
information refer to the 7360 ISAM FX Hardware Installation Manual.

3FE 53701 ADAA TQZZA Ed 01

Released

9 / 12

FANT-F AD
8

Combined NT Unit version F

Physical Description
Figure 4 shows the side and front view of the FANT-F.
Fig. 4: View of the FANT-F AD

LEDs

SFP cages

1PPS Signal
10MHz Signal
Front Uplink Interface
CRAFT Interface
Time of Day
BITS in
BITS out

3FE 53701 ADAA TQZZA Ed 01

Released

10 / 12

Combined NT Unit version F

FANT-F AD

Dimensions:
The dimensions of the FANT-F AD are:

Board height: 405 mm


Width: 30 mm
Depth: 205/225 mm
System Status LEDS
Figure 5 shows the system status LEDs of the FANT-F AD.
Fig. 5: System Status LEDs
ACO

ALM

PWR

ACO

A/S

FSM2

FSM1

FSM4

FSM3

Table 8 gives the definitions of the system status LEDS on the FANT-F.
Table 8: System Status LED Definition
Port

Description

PWR

A/S
ALM
ACO
FSM1
FSM2
FSM3
FSM4

Green - Power present


Off - No power
Green - Active
Off - Stand-by
Red - Alarm condition exists
Off - No alarm condition exists
Green - Alarm has been cut off
Off - No alarm cut off
Link/Activity status (module 1)
Link/Activity status (module 2)
Link/Activity status (module 3)
Link/Activity status (module 4)

Alarm Cut Off


The FANT-F AD is equipped with an Alarm Cut Off switch and an Alarm Cut Off
indication LED (refer to Figure 5).

3FE 53701 ADAA TQZZA Ed 01

Released

11 / 12

FANT-F AD
9

Combined NT Unit version F

Power Supply
The FANT-F is compatible with -48 Vdc nominal and -60 Vdc nominal power supply
systems.
Note: Country dependent tolerances exist regarding the nominal battery voltage values.

3FE 53701 ADAA TQZZA Ed 01

Released

12 / 12

You might also like