SLS
C US
Old Technology
Blocks light, poor
redirection control
Adds wind loading
- requires stronger,
more expensive
poles
Environmental Spill/Glare
Control Optics
OUTDOOR: FLOODLIGHTING
The SLS Series optical design controls spill and glare from
the luminaires producing excellent field beam control. The
lamp is mounted transversely to a developed curve profile
which produces a specific candlepower distribution.
Internal faceted louvers capture upward light from the arc
tube and reflector redirecting unused light back into the
usable field beam. It provides 13 V and 35 H cut-off of
the arc tube, reducing glare as much as 95%.
Internal louvers reduce wind loading as much as 28%
lowering costs and simplifying maintenance.
Utilizes common BT-56 metal halide lamps. A lamp
support is standard ensuring precise lamp positioning and
control.
Fewer fixtures needed overall to achieve required light
levels and maintain uniformity.
C US
Hubbell Lighting
16
Catalog Number1
SLS-XXXXX-020
SLS-XXXXX-030
SLS-XXXXX-040
SLS-XXXXX-050
SLS-XXXXX-060
SLS-XXXXX-0N0
SLS-XXXXX-0M0
SLS-XXXXX-0W0
SLS-1000H-128
SLS-1000H-138
SLS-1000H-148
SLS-1000H-158
SLS-1000H-168
SLS-1000H-1N8
SLS-1000H-1M8
SLS-1000H-1W8
SLS-1500H-128
SLS-1500H-138
SLS-1500H-148
SLS-1500H-158
SLS-1500H-168
SLS-1500H-1N8
SLS-1500H-1M8
SLS-1500H-1W8
SLS-1650H-128
SLS-1650H-138
SLS-1650H-148
SLS-1650H-158
SLS-1650H-168
SLS-1650H-1N8
SLS-1650H-1M8
SLS-1650H-1W8
SLS-0600S-128
SLS-0600S-138
SLS-0600S-148
SLS-0600S-158
SLS-0600S-168
SLS-1000S-128
SLS-1000S-138
SLS-1000S-148
SLS-1000S-158
SLS-1000S-168
Watts
NEMA beam
Type
Spread H x V
Weight
lbs.
kg
EPA 2
ft.2
m2
18.0
18.0
18.0
18.0
18.0
20.5
20.5
20.5
8.2
8.2
8.2
8.2
8.2
9.3
9.3
9.3
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
47.0
47.0
47.0
47.0
47.0
49.5
49.5
49.5
50.0
50.0
50.0
50.0
50.0
52.5
52.5
52.5
53.0
53.0
53.0
53.0
53.0
55.5
55.5
55.5
21.4
21.4
21.4
21.4
21.4
22.6
22.6
22.6
22.8
22.8
22.8
22.8
22.8
23.9
23.9
23.9
24.1
24.1
24.1
24.1
24.1
25.3
25.3
25.3
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
46
46
46
46
46
51
51
51
51
51
21.0
21.0
21.0
21.0
21.0
23.2
23.2
23.2
23.2
23.2
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1. Catalog numbers listed are with Quad-Tap 120/208/240/277 ballasts. For other voltages, refer to Catalog Logic. Not available with remote head units.
2. Effective Projected Area (EPA) - Maximum projected area tested at wind velocities to 125 m.p.h.
3. For remote unit, specify wattage and lamp type to be used (H) for MH and (S) for HPS. Example: SLS-1000H-020. 600W HPS may not be remote ballasted.
NEMA Beam degrees shown are for 1500W and below. For 1650W, see ordering information, for
ballasted units.
4. This beam spread is not standard. Consult factory.
Hubbell Lighting
17
ORDERING INFORMATION
OUTDOOR: FLOODLIGHTING
SLS SERIES
SLS
series
1500
wattage
-H
lamp type
WATTAGE
1000
1500
1650
0400
0600 14
1000
LAMP TYPE
H
S
Metal Halide
High Pressure Sodium
BALLAST TYPE
02
1
-1
-2
-8
- PH
ballast type
beam
distribution
voltage
options
OPTIONS
-3C(X)
-6C(X) 7,15
-12C(X)
-F(X) 8
-PH 9
-L
-HO
-SD1 10
BEAM DISTRIBUTION
2
NEMA Type 2
3
NEMA Type 3
4
NEMA Type 4
5
NEMA Type 5
6
NEMA Type 6
N 12,13
Narrow Beam Horizontal Lamp
M 12,13
Medium Beam Horizontal Lamp
W 12,13
Wide Beam Horizontal Lamp
OUTDOOR: FLOODLIGHTING
VOLTAGE
1
2
3
4
54
66
71
8
02
E3
C5
7,15
-SD2 10
-SG 11
-M51
-UA
7,15
120V
208V
240V
277V
480V
Tri-Tap (120, 277, 347V)
600V
Quad Tap (120, 208, 240, 277V)
Remote Head Only (no ballast)
220/240V 50 Hz
347/480V
Hubbell Lighting
18
SLSV 1, 4
SL-HCL 4
SL-CL 4
SLS-SPC 2
SLS-AA-REM
FL-C3-14
FL-C3-16
FL-C6-14
FL-C6-16
SLSF
SLSFF
5010 3
5090 5
SLSC
Description
lbs.
kg
4
4.0
1.8
1.8
3.0
1.4
3
2
3
5
2
1.0
1.4
0.9
1.4
2.3
0.9
.45
4024 SLS
5010
SLS-SPC
SL-CL
4090
5090
SL-HCL
SLS-V
OUTDOOR: FLOODLIGHTING
4024C
Hubbell Lighting
19
1500H
series
SERIES
REM
REM D 3
REM A
REMA D 3
wattage
TB
Voltage
Ballast
Quantity
options
BALLAST QUANTITY
6
Six Ballasts
11
Two Ballast, 2 circuit, 1 & 1
21
Three Ballast, 2 circuit, 2 & 1
22
Four Ballasts, 2 circuits, 2 & 2
31
Four Ballasts, 2 circuits, 3 & 2
32
Five Ballasts, 2 circuits, 3 & 2
33
Six Ballasts, 2 circuits, 3 & 3
41
Five Ballasts, 2 Circuits, 4 & 1
42
Six Ballasts, 2 Circuits, 4 & 2
51
Six Ballasts, 2 Circuits, 5 & 1
WATT
1000H
1500H
1650H 5
VOLTAGE
208V
240V
277V
480V
347V
3
4
5
6
OPTIONS
SD11
SD21
TB2
T4
WP
BALLAST QUANTITY
1
One Ballast
2
Two Ballasts
3
Three Ballasts
4
Four Ballasts
5
Five Ballasts
1. Consult Factory.
2. Load break switch is standard on 277V, 480V and 347V. Thermal
magnetic breakers are standard on 208V and 240V.
3. Used for switching.
4. 208, 240 and 480V only
5. Maximum 4 ballasts.
C
E
D
OUTDOOR: FLOODLIGHTING
E
SLS Remote Ballast System
A
41"
1041 mm
B
20 3/8"
518 mm
C
8 3/4"
222 mm
D
45 1/2"
1156 mm
E
3/4" Dia.
19 mm
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
1000
110
50.1
131
59.6
152
69.2
173
78.8
194
88.3
215
97.9
1500
120
54.6
151
68.7
182
82.9
213
97.0
244
111.1
275
125.0
1650
123
56.0
157
71.5
191
87.0
225
102.4
N/A
N/A
N/A
N/A
Hubbell Lighting
20
Aimed 40
below
horizontal
Aimed 40
below
horizontal
A
Axial Optics
Horizontal Optics
A
B
C
D
22 1/2" 5 33/64" 20 1/8" 35 3/4"
572 mm 140 mm 511 mm 907 mm
A
B
C
22 1/2" 36 5/8" 5 1/4"
572 mm 930 mm 133 mm
E
106
C
G
90
Axial Optics
Horizontal Optics
A
B
C
D
E
F
G
20 1/8" 22 1/2" 4 3/4"
12"
8 1/8" 18 7/8"R
9"R
511 mm 572 mm 121 mm 305 mm 206 mm 479 mm 229 mm
A
B
C
D
3 1/2"
21"
22 1/2"
13"
89 mm 533 mm 572 mm 330 mm
D
C
A
B
SLS Remote Yoke
A
B
C
D
3 1/8" 7/8"Dia. 17/32" Dia.
2"
79 mm 22 mm
13 mm
51 mm
Hubbell Lighting
21