Professional Documents
Culture Documents
Full Ton
Full Ton
Full Ton
No Corrosion or Freezing
1500
Saturated Steam/Water
Thermal Fluid
1000
500
400
300
200
100
0
0C
32F
Fulton Deaerator
or Expansion Tank
Fulton Thermal
Fluid Heater
Fulton SteamPac
Fulton WaterPac
Storage
Tank
Press, Mold, or
Platten
Bath or
Kettle
Rolls
Fryer
Reactor
Oven
FT-C 0080
0120 0160
800
200
10
38
50
11.4
1,200
300
21
80
75
17
1,600
400
19
72
100
22.7
2,400
600
31
116
150
34
3,200
800
68
258
250
56.8
4,000
1,000
76
288
250
56.8
6,000
1,500
132
498
375
85.2
GPH
LPH
FT3/HR
M3/HR
7.1
27
998
38.3
10.7
40.6
1,498
42.4
14.3
54.1
1,998
56.5
21.4
81
2,999
84.9
28
108.8
4,000
113.2
35.3
136
4,997
141.5
53
201
7,498
212.3
69.3
87.1 104.5
122
263.7 329.6 395.5 461.5
9,997 12,496 14,998 17,500
283 353.8 424.6 495.5
HP
KW
HP
KW
10
7.5
1.5
1.1
10
7.5
3
2.2
15
11.2
3
2.2
15
11.2
3
2.2
20
14.9
5
3.7
20
14.9
5
3.7
30
22.5
7.5
5.6
Heat Output
1,000 BTU/HR
1,000 KCAL/HR
Thermal Fluid Content
GAL
LITERS
Recommended Flow Rate
GPM
M3/HR
Power
Typical Circulating
Pump Motor
Typical Burner Motor
40
29.5
15
11.2
50
37.3
15
11.2
50
37.3
20
15
60
45
20
15
Voltage 3 Phase for Burner and Pump - Each unit has an incorporated stepdown transformer.
Fuel up to No. 6 Oil Available for Large Units. (FT-0600-C and larger)
Efficiency up to 80% Minimum Based on High Heating Value of the Fuel (No. 2 Oil @ 140,000 BTU/GHHV; Natural Gas @ 1,000 BTU/ft3HHV.
Circulating pump motor sizes based on standard pressure (55 PSIG) and viscosity 1 cs, specific gravity 0.7, with 25-37 PSID available head for installation.
All Units are Modulated. Operating specifications may change based on field conditions.
Dimensions
Models
FT-C 0080
IN
MM
IN
MM
IN
MM
IN
MM
IN
MM
IN
MM
LB
KG
1.25
32
73.7
1,872
31.6
803
46.2
1,173
10
254
10
254
1,500
700
0120 0160
1.5
38
80.7
2,050
34.4
873
60.6
1,540
10
254
12
304
2,100
950
2.5
64
89.7
2,278
50.1
1,273
66.6
1,691
12
305
14
356
3,400
1,550
4
4
6
6
6
102
102
152
152
152
143.6
143 146.5 146.4 163.1
3,648 3,632 3,721 3,718 4,144
63.4
70.5
95 108.4 108.4
1,611 1,791 2,413 2,753 2,753
88.1 107.75 135.1 152.9 152.9
2,237 2,736 3,432 3,882 3,882
18
20
20
22
22
457
508
508
559
559
22
24
24
26
26
558
609
609
661
661
8,250 11,450 19,250 21,700 23,000
3,750 5,200 8,750 9,850 10,455
2
51
80.6
2,046
45.9
1,165
60.6
1,540
10
254
12
304
2,550
1,150
3
76.3
100.6
2,556
49.3
1,252
80.6
2,046
14
356
18
457
5,300
2,400
3
76
112.4
2,856
49.3
1,252
80.6
2,046
14
356
18
457
5,300
2,400
D
A
C
Diagram for guidance purposes only. Comprehensive details of dimensions, connections, etc. for each model are given on product dimension data sheets available from Fulton.
Expansion
Tank
Liquid
Level
Switch
Hot Fluid
Fluid In
Medium Fluid
Cool Fluid
Deaerator
Section
Gases (Steam)
Fluid Out
Thermal
Buffer Section
Drain
FT-L
0200
0500
1000
1500
2000
3000
5000
Gallons
Gallons
Gallons
Gallons
LBS
KG
52
25
46
184
636
289
132
40
121
525
970
440
264
80
232
1,000
1,350
612
397
90
380
1,400
1,710
776
528
145
444
1,700
2,550
1,134
793
215
717
2,600
3,200
1,451
1,310
300
1,168
4,600
5,300
1,637
Specifications
Models
Heat Output
Thermal Fluid Content
Recommended Flow Rate
FT-A
0200
0380
0520
0690
1050
1740
1,000 BTU/HR
1,000 KCAL/HR
GAL
LITERS
GPM
M3/HR
207
52
23
87
90
21
348
88
38
144
90
21
519
131
45
170
125
28
693
175
65
246
125
28
1,052
265
98
371
150
34
1,736
437
117
443
200
46
GPH
LPH
FT3/HR
M3/HR
2.2
8.3
259
7.2
3.2
11.9
435
12.2
4.7
17.8
649
18.4
6.7
25.4
866
24.2
9.4
35.6
1,315
36.8
15.8
60
2,170
60.8
HP
KW
HP
KW
10
7.5
.33
.248
10
7.5
.33
.248
15
11.2
.33
.248
15
11.2
.75
.56
15
11.2
.75
.56
20
14.9
1.5
1.1
Power
Typical Circulating Pump Motor
Typical Burner Motor
FT-A
0200
0380
0520
0690
1050
1740
IN
MM
IN
MM
IN
MM
IN
MM
IN
MM
LB
KG
1.5
38
69
1,752
26
660
43
1,092
6
152
1,850
840
1.5
38
75
1,905
28
710
45.5
1,156
6
152
2,100
955
2
51
85
2,159
30
760
46
1,168
8
203
2,300
1,045
2
51
86
2,185
36
915
56
1,422
10
254
3,400
1,540
2
51
86
2,185
44
1,120
64
1,626
12
305
4,400
1,995
2.5
64
110
2,794
44
1,120
64
1,626
12
305
7,200
3,275
D
A
Operating Principle
The top-mounted down fired
burner delivers a spinning flame
down the length of the furnace. As
the flame swirls downward in a
controlled flow pattern the fluid
spirals upward in the pressure
vessel. Hot gases from the flame
are carried up the outside of the
vessel in the secondary flue
passage
convection
area.
Convection fins welded along the
full length of the vessel transmit
the remaining heat through the
outer side of the fluid vessel and
into the fluid. The result is even
heating of thermal fluids for
optimum thermal efficiency.
Specifications
Models
KW
Heat Input
1,000 BTU/HR
1,000 KCAL/HR
Heat Output 1,000 BTU/HR
1,000 KCAL/HR
Thermal Fluid Content GAL
LITERS
Recommended
GPM
Flow Rate
M3/HR
22
75
18.9
74
18.6
18
68
50
11.4
44
150
37.8
148
37.3
36
136
50
11.4
66
225
56.7
222
59.9
42
159
50
11.4
88
300
75.6
294
74.1
54
204
90
20.5
110
375
94.5
368
92.7
63
238
90
20.5
126
429
108
420
105.8
79
299
125
28.4
189
644
162
631
159
79
299
125
28.4
252
859
216
842
212.2
102
386
150
34
315
1,074
271
1,053
265.4
127
480
150
34
378
1,289
325
1,263
318.3
152
575
175
39.8
441
504
1,504 1,719
379
433
1,474 1,685
371.4 424.6
168
185
636
700
200
200
45.5
45.5
7.5
5.6
61
53
26
7.5
5.6
122
106
53
7.5
5.6
183
159
79
10
7.5
245
212
106
10
7.5
306
265
132
15
11.2
350
303
151
15
11.2
525
455
228
15
11.2
700
607
303
15
11.2
875
758
379
15
11.2
1,050
910
455
20
20
14.9
14.9
1,224 1,399
1,061 1,212
531
606
Power
Typical Circulating
Pump Motor
Amps
HP
KW
208V
220V
480V
Heater Inlet
(A) Overall Height
(B) Heater Width
(C) Overall Depth
Approx. Dry Weight
IN
1.5
MM
38
IN
70
MM 1,778
IN
20
MM
508
IN 37.5
MM
953
LB 1,060
KG
481
1.5
38
70
1,778
26
660
43
1,092
1,220
555
1.5
38
70.5
1,791
28
711
43.5
1,105
1,400
636
1.5
38
70
1,778
32
813
47.5
1,207
1,540
700
1.5
38
70
1,778
32
813
47.5
1,207
1,660
756
2
51
90.8
2,306
38
965
53.8
1,365
2,370
1,077
2
51
90.5
2,299
32
813
47.5
1,207
2,040
927
2
51
90.4
2,296
32
813
49.5
1,257
2,200
1,000
2
51
89.8
2,281
44
1,118
58.4
1,257
2,650
1,205
2
51
91.2
2,317
50
1,270
65.7
1,669
2,950
1,341
2.5
64
93
2,362
54
1,372
71.8
1,823
2,950
1,341
2.5
64
93
2,362
58
1,473
75.7
1,993
3,600
1,636
A
B
Operating Principle
A
D
C
Specifications
Models
Heat Output
Thermal Fluid Content
Recommended Flow Rate
FT-HC
0240
0400
0600
0800
1000
1200
1600
2000
1,000 BTU/HR
1,000 KCAL/HR
GAL
LITERS
GPM
M3/HR
2,400
600
75
284
150
35
4,000
1,000
115
435
300
69
6,000
1,500
190
719
400
91
8,000
2,000
264
998
600
137
10,000
2,500
325
1,230
850
193
12,000
3,000
508
1,921
1,000
227
16,000
4,032
480
1,817
1,200
273
20,000
5,040
1,150
4,353
1,500
341
GPH
LPH
FT3/HR
M3/HR
23
88
3,200
91
39
148
5,340
152
58
220
8,000
227
77
292
10,700
304
96
364
13,340
378
115
436
16,000
454
143
542
20,000
566
179
678
25,000
708
HP
KW
HP
KW
15
11.2
2
1.5
25
18.7
5
3.7
30
22.5
7.5
5.6
50
37.3
10
7.5
60
45
15
11.2
75
56.3
15
11.2
100
74.5
30
22.4
125
93.2
30
22.4
Power
Typical Circulating Pump Motor
Typical Burner Motor
FT-HC
0240
0400
0600
0800
1000
1200
1600
2000
IN
MM
IN
MM
IN
MM
IN
MM
IN
MM
LB
KG
2.5
64
64
1,626
62
1,575
134
3,404
12
305
5,000
2,272
3
76
68
1,727
62
1,575
137
3,480
14
356
7,500
3,409
4
102
78
1,981
81
2,057
157
3,988
18
457
9,500
5,455
6
152
107
2,718
95
2,413
182
4,623
22
559
12,500
5,682
6
152
107
2,718
95
2,413
182
4,623
22
559
19,250
8,750
6
152
131
3,327
130
3,302
240
6,096
22
559
21,700
9,864
8
203
114
2,896
118.5
3,010
327
8,306
36
914
39,000
17,728
8
203
118
2,997
119.5
3,035
351
8,915
36
914
39,000
17,728
Specifications and Dimensions are approximate. We reserve the right to change specifications and/or dimensions without notice.
D
Operating specifications may change based on field conditions.
Operating Principle
The burner fires down the center of the coil. The hot gases
return between the coils to the front end plate, then flow to
the back of the heater, exiting out the flue.
A
E
D
B
System Accessories
Unfired Steam Generators
Vertical Design 10HP to 100HP
Horizontal Design 70HP to 350 HP (Custom
sizes are available)
Standard Designs 15 psig to 150 psig
(custom operating pressures are available)
Built and Stamped to ASME Code Section
VIII Div. I
Complete with Modulating Thermal
Fluid Control Valve
May be Skid Mounted with Blowdown
Separators, Return Tanks, Deaerator
Tanks, Feedwater Pumps, Chemical
Tanks and Water Softeners
www.fulton.com
ftc-bro-2010-1011