CONSTRUCTION SPECIFICATION
By:
Acedillo, Neil Franco D.
_______________________________
Galua, Ranilyn
_______________________________
Senados, Bernard
_______________________________
Instructor:
Specifications
Positioning Bars
Position vertical bars accurately at the centerline of the wall. Maintain a minimum
clearance between the bars and masonry units of 12 mm and between parallel bars of
one diameter of the reinforcement. Hold vertical reinforcing in place using metal
supports, centering clips, spacers, ties or caging devices located near the ends of each
bar and at intermediate intervals of not more than 192 diameters of the reinforcement.
Splices
Locate splices only as indicated. Stagger splices in adjacent bars at least 600 mm.
Lap bars a minimum of 40 diameters of the reinforcement.
B.
B.
SCOPE
1.
Furnish materials, tools and equipment and perform labor and services
required to complete fabrication and erection of al structural steel.
2.
RESPONSIBILITY
1.
Contractor shall be responsible for the accurate location of all steel work
including items used to attach materials to other parts of the work.
2.
Contractor shall see to it that any or all items of work which, are to be built
into work of other trades are installed at the proper time.
3.
Contractor shall notify the Consultant if the steel work shall be fabricated in
a shop other than the site, so That arrangements can be made together with
the Project Inspector in the inspection of the delivered materials and in the
fabrication of the steel work.
Producers or Manufacturers Specification for :
Structural Steel
High Strength Bolts (each type) including nuts and washers
Mild steel bolts and nuts
Structural Steel primer paint
Grating type treads for stairs and their fasteners
Conform all materials and workmanship to the requirements of the American Institute
of Steel Constructions (AISC) Specifications for the Design, Fabrication and
Erection of Structural Steel for Buildings as amended to date or as may be
specifically modified by the drawings or by these specifications.
B.
Conform structural steel plates and shapes to ASTM Designation A36 with a minimum
specified yield strength of 248 MPa (36,000 Psi).
C.
228
Conform cold-formed steel to ASTM A611 with a minimum specified yield strength of
MPa (33,000 Psi).
B.
Welding Society (AWS) Specification D 1.1. Minimum thickness of weld shall be 3.0mm.
E.
Conform anchor bolts to the Specification for High Strength Bolts ASTM A 325,
Type 1 or 2 unless otherwise specified.
F. Conform common bolts to the Specification for Low Carbon Steel Externally and
Internally
Threaded Standard Fasteners, ASTM A-307
STAIRS
12mm nosing bar
12mm @ 250mm o.c. chair bar
12mm @300mm o.c. top & bot. trav.bars
16mm @125mm o.c. top & bot. long.bars
1" x 1" x 1.2" thk. square tube
1" x 2" x 1.2" thk. rectangular tube
1 x 3 x 1.5 thk. rectangular tube
HAND RAILS
2" x 3" x 1.5" thk. rectangular tube
1 1/2" x 1/4" thk flat bar
10mmx80mm expansion bolt
6mm thk ms plate
EXIT LADDER
1" x 1" x 3/16" thk. Angle bar
1/2" SCH. 20 G.I pipe
A
General:
A. Preassemble railing systems in shop to greatest extent possible to minimize field
splicing and assembly.
B. Disassemble units only as necessary for shipping and handling limitations.
Clearly mark units for reassembly and coordinated installation. Use connections
that maintain structural value of joined pieces.
C. Grind smooth welded joints and buff welds to same appearance as remainder of
railing. Repair galvanizing and cut pipe ends as specified in Section 05 0503.
D. Return pipe ends of wall mounted handrails into wall.
E. Cap pipe ends of floor / ground mounted handrails and exterior handrails.
F. After fabrication, shop prime metal to be painted.
C. Form curves by bending pipe in jigs to produce uniform curvature for each
configuration required. Maintain cylindrical cross-section of pipe throughout entire
bend without buckling, twisting, cracking, or otherwise deforming exposed surfaces of
pipe.
D. Welded Connections:
A. Fabricate railing system and handrail connections by welding.
B. Weld corners and seams continuously to comply with following:
1. Use materials and methods that minimize distortion and develop strength and
corrosion resistance of base metals.
2. At tee and cross intersections, notch ends of intersecting members to fit
contour of pipe to which end is joined and weld all around.
3. At exposed connections, finish exposed welds and surfaces smooth and
blended so no roughness shows after finishing and so contours of welded
surfaces match adjacent surfaces.
E. Brackets, Flanges, Fittings, And Anchors:
A. Provide standard wall brackets, flanges, miscellaneous fittings, and anchors for
connection of handrails and railings to other construction.
B. Provide inserts and other anchorage devices for connecting handrails and railing
systems to concrete or masonry work.
DIVISION 06: WOOD, PLASTICS, & COMPOSITES
CARPENTRY
Red lauan - sound and thoroughly seasoned, warp free, smooth and level on one side or
whenever in contract with panellings, ceiling joists and nailers.
Tanguile or Lauan Sun dried ,s4s,sound ,hardband free from defects lumber. Use one color or
shape for assembly framings, which are exposed. Maximium moisture content nfor all others.
For framings of counters ,cabinets, edgings, and trims. For sidings, undersides and frames of
composite beams. Use in false beams or nailers/studs.
Guijo or Yacal -s4s lumber, sun-dried. For the underside hoizontal frame of pediment walls or
composite beams carrying sliding door tracks for doors and transom jambs.
Plyboard, Plywood: Alcantara & Sons or approved equal.
Hardware and Fasteners: use metal nails,screws, bolts, plates,miscellaneous fasteners or
anchorage concealed or countersunk whenever called for, with size, shape and type to ensure
resistant glue for lamintaed items and cabinet framing joints.
ROUGH CARPENTRY
Wood furring, sheathing, and blocking for built in casework and nailers for the top of all roofframing members; minimum 5/8-inch thick structural grade plywood for roof sheathing.
FINISH CARPENTRY
Wood veneer finish casework, solid wood and/or plastic laminate counters
3/4" thk. Marine plywood cabinet shutter
COMPOSITE
Where cutting of material is necessary, use sharp knife and straight edge.
Fit tight around all roof protrusions. Fill the gaps with off-cuts to avoid heat leakages.
Side and end laps shall be 100mm (4) and adhered by aluminum tape on bottom side.
Install insulation before roofing is fixed.
Any accidental punctures and damages shall be repaired and sealed with 50mm
(2 inches) aluminum tapes.
DIVISION 08: OPENINGS
6 mm. THK. BRONZE GLASS ON ANOLOK FRAMING SLIDING WINDOWS,
LAWAAN PANEL DOOR ON 2" x 6" LAWAAN KD DOOR JAMB,
GALVALUME TYPE ROLL-UP DOORS
6 mm. THK. BRONZE GLASS ON STEEL CASEMENT WINDOWS
PVC DOOR w/ LOUVERS ON PVC DOOR JAMB,USE NELTEX BRAND
DIVISION 09: FINISHES
092216 NON-STRUCTURAL METAL FRAMING
Metal furring ceiling joist.
092900 HARDIFLEX
Use 4.5 thk. Hardiflex on all ceilings.5/8" water resistant hardiflex in wet areas. Use
cementitious glass mesh mortar units on walls designated to have ceramic tile applied.
093013 CERAMIC TILES
Use 0.30m. x 0.30m. ceramic tile for toilet wall and quarry tile as manufactured by
LEPANTO or any approved equal for toilet floor (Public and Staff).
096500 RESILIENT FLOORING
Provide resilient flooring in utility, storage, and mechanical spaces.
096813 TILE CARPETING
Continuous filament, soil repellent, recycled material carpet tile with a pile weight of not
less than 36 oz. per square yard in every room.
099100 PAINTING
Epoxy coatings in toilet rooms, alkyd enamel semi-gloss paints on scheduled walls and
ceilings. Use clear stain on interior and exterior wood trim. Ceilings painted white. Meet
state volatile organic compound requirements.
Provide stone cladding manufactured by Piedra or any approve equal for every post in front
of the building.
DIVISION 08: SPECIALTIES
Provide 40 cm. x 40 cm. aluminum composite panels for canopy and balcony cladding
manufactured by AULAND.
Pipes and fittings for waterline shall be a specified by EPPI. For waterlines, use sched.
40 APO Pipe, for ground drainage, use 6 inches diameter and 8 inches diameter concrete
culvert. The arrangement, position and connection of pipe fixtures, drains, valves and
the like indicated on the drawings shall be followed as closely as possible, the right is
reserved by the Procuring Entity to change location and elevations to accommodate
conditions which may arise during the progress of the work prior to installation, without
additional cost of the Procuring Entity for such changes. The responsibility for
accurately laying out of the work rests with this Contractor. Should be found that any
work if laid out caused interference, the matter shall be reported to the Engineer before
connecting the work.
b.
Fittings: use reducing fittings, in making reduction in size of pipe. Bushing will not be
allowed unless specifically approved.
c. Traps - Each fixture and place of equipment connection to the drainage system except
fixture with continuous waste shall be equipped with a trap. Traps shall be placed as near
to fixtures as possible.
d. Valves-All valves, unless otherwise specified shall be gate valves of size as indicated in
the drawings: for hot water supply, valves and fittings shall be insulated of a thickness
equal to that of the insulation on the adjoining pipe, securely fastened in place.
e. No piping shall be installed which will provide a cross or interconnection between a
distribution supply of drinking water of Domestic use and pollution or waste pipe, the
water line shall be placed above the waste pipe in ground installation.
SECTION 15003 SANITARY DRAINAGE
a. Soil and waste Pipes and Fittings: Soil and waste pipes and fittings shall be PVC pipes
(POLYVINYL CHLORIDE) series 1000.
b. Vent Pipes and Fittings: Vent pipes and fittings shall be PVC pipes
c. Cleanouts: Cleanouts shall be cast-iron body with brass plug, colt-type or countersunk
head.
211300 FIRE SUPPRESSION SPRINKLER SYSTEMS
Design, furnish, install, and test automatic wet pipe fire sprinkler and standpipe systems
for the entire building, including attics, crawl spaces, and concealed spaces in accordance
with NFPA 13.
Service Entrance: 2-150 millimeter THR wire in 65 millimeter in diameter in RSC pipe is
to be used. Use 150 KVA; 13800 / 7600 440 / 220 Volts Distribution Transformer from
the Davao Light & Power Co. Service Line.
Bolt-on type panel boards with ratings exceeding the connected loads and available fault
current in accordance with applicable sections of the Philippine Electric Code. Protect
branch circuits serving exterior receptacles or circuits located in toilets, damp, or wet
locations with ground fault circuit interrupters. NEMA type/enclosure unless noted, PEC
rules and regulations, circuit breaker type shall be 230V, number of pole as required.
Breaker minimum interrupting capacities shall be based on NEMA and UL test
procedures.
a. 230 volt breakers - 10,000 rms. Symmetrical amperes at 240V A/C (minimum)
SECTION 16001 CONDUIT, FITTINGS AND WIRING
Conduit and Fittings: Rigid steel or intermediate metal conduits. Use a25 square
millimeter diameter RSC pipe, joints-threaded coupling for joints with 60Amperes; 2-P
230Volts ACB as main feeder conductor and protection respectively. Standard trade sizes,
hot dipped galvanized with inside enamel or epoxy coating for protection.
Wiring: Wires shall be annealed copper, 98& conductivity, insulated, single, except as
noted in the drawings.Use2-14.0 millimeter THW as a type of wire.
For the interior, use 4 inches diameter recessed pin light with 10 WATTS Philips Energy
Saving Light, cool white and 38 WATTS Sum Type Philips Fluorescent Lamp with
electronic ballast. Thus, use 4 inches diameter surface mounted pin light with 10 WATTS
of Philips Energy Saving Light, warm light on black color 4 by 6 inches diameter surface
type housing pin light for outside the balcony.
As for exterior lights, outdoor weather proof lamp 5 WATTS with warm white energy
saving light.