Professional Documents
Culture Documents
Catalog - Waveguides 2006-02 Usa
Catalog - Waveguides 2006-02 Usa
Catalog - Waveguides 2006-02 Usa
Kabelwerk Eupen AG
Contents
Introduction
Introduction
1. Bending tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2. Flaring tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3. Shim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
4. Pressure windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5. Twistflex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6. Grounding kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7. Fixing clamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
8. Hoisting grips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
9. Additional weatherproofing solutions . . . . . . . . 23
10. Dehydrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
...........................................4
Waveguide, connectors,
tools & grounding clamps
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Waveguide EU 63 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Waveguide EU 77 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Waveguide EU 90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Waveguide EU 127 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Kabelwerk Eupen AG
Port de Bonneuil
5, route de Stains
94387 Bonneuil sur Marne
FRANCE
Karl-Kuck-Str. 3
52078 Aachen
DEUTSCHLAND
Agencies Africa
Egypt
South Africa
Agencies America
Brazil
Canada
Chile
Columbia
Cuba
USA
Peru
San Salvador
Kabelwerk Eupen AG
Agencies Europe
Austria
Bulgaria
Denmark
Estonia
Finland
Germany
Greece
Hungary
Ireland
Italy
Jordan
Latvian Republic
Norway
Palestine
Poland
Romania
Russia
Spain
Slovenia
Sweden
Tchech Republik
The Netherlands
Turkey
Ukraine
Agencies Asia
Hong Kong
India
Iran
Japan
Korea
Lebanon
Kingdom of Saudi Arabia
Singapore
Sri Lanka
Syria
Thailand
Taiwan R.O.C.
UAE
Agencies Oceania
Australia
New Zealand
Introduction
Introduction
EUPEN elliptical waveguides are the
optimal choice for most microwave
antenna feeder systems. EUPEN waveguides are precision-formed from corrugated high-conductivity copper and
have an elliptical cross section. The
corrugated wall gives the waveguide
excellent crush strength and good flexibility for ease of handling. A rugged
black polyethylene jacket provides protection during installation. The jacket is
weatherproof and ultraviolet-stabilized
to prevent deterioration. Standard
jacketing material is suitable for operation down to -40C (-65F) and installation down to -20C (-40F). A range of
waveguide sizes is available for
applications from 5.85 to 13.25 GHz.
PREMIUM PERFORMANCE
LOW LOSS EUPEN elliptical waveguides are optimized for lowest loss in
specific user bands. Attenuation is
significantly lower than that of standard
rectangular waveguides for these
bands, resulting in highly efficient signal
transfer which optimises overall system
performance.
LOW SIGNAL DISTORTION
The elliptical cross section has HEC11 as
the principal mode, which is similar to
the TE10 mode in rectangular waveguide, and propagates below the cut-off
frequencies of higher-order modes.
Operating in the frequency band where
only the dominant mode can exist
eliminates signal distortion due to
dispersion and minimizes VSWR.
EUPEN Waveguides
The best choice for flexible transmission lines with superior electrical
performance for modern microwave
systems and other broadband
wireless applications.
Kabelwerk Eupen AG
O p t i o n a l F l a m e - r e ta r d a n t
Jacket
EUPEN elliptical waveguide is available with a flame-retardant, non-halogenated
FRNH jacket.
This jacketing material is intended for installation indoors or in confined areas
where there is limited exposure to sunlight or ultra-violet radiation.
The FRNH elliptical waveguide is available in all sizes. Products with this rating
are found in ducts, plenums or other spaces used for environmental air.
Unjacketed waveguide pass the most stringent fire resistance tests.
Kabelwerk Eupen AG
H A LO G E N F R E E and
F L A M E R E S I S TA N T f e a t u r e s
Test on flammability
a) Test on flammability of single cables
Test in accordance with: VDE 0472 Part 804-B
BS 4066 Part 1
IEC 60332-1
Kabelwerk Eupen AG
Premium
elliptical
waveguide
Product reference
Product reference
EU 63
PE Jacket
EU 63-FR
FRNH* Jacket
(on request)
Construction
mm (in)
mm (in)
mm (in)
200 (7.9)
500 (19.7)
Frequency range
GHz
5.85 - 7.125
GHz
4.1
Outer dimensions
Mechanical characteristics
Minimum bending radius
single bending
E Plane
H Plane
Electrical characteristics
@ 6.3 GHz
4,32 (1.32)
@ 6.3 GHz
74.5
Group velocity
VSWR max.
* flame-retardant, non-halogen
Kabelwerk Eupen AG
1.06
7/8
Foam-Dielectric
Elliptical
waveguide
EU 77
EU 90
EU 127
EU 77-FR
EU 90-FR
EU 127-FR
(on request)
(on request)
(on request)
200 (7.9)
500 (19.7)
150 (5.9)
300 (11.8)
125 (4.9)
250 (9.8)
7.125 - 8.5
10.2 - 11.7
11.7 - 13.25
5.0
6.75
7.9
@ 7.7 GHz
6,21 (1.89)
@ 10.9 GHz
9,63 (2.93)
@ 12.7 GHz
11,74 ( 3.58)
@ 7.7 GHz
76.0
@ 10.9 GHz
78.5
@ 12.7 GHz
79.2
1.06
1.06
1.08
Kabelwerk Eupen AG
EU 63
PE Jacket
EU 63
Waveguide type:
FRNH Jacket
EU 63-FR
Waveguide type:
on request
CHARACTERISTICS
Construction
Description
Electrical
Corrugated elliptical copper tube
Conductor
Material
Elliptical mm (in)
Jacket
Material
Dimensions mm (in)
Thickness mm (in)
copper
47,9 x 26,8 (1.89 x 1.06)
Frequency
Attenuation(1)
GHz
dB/100m (dB/100ft)
5.9
6.0
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
7.0
7.1
Mechanical
200 (7.9)
500 (19.7)
300 (11.8)
700 (27.6)
3 (1)
60 (197)
1200 (47)
0,5 (7.3)
10
0,84 (0.56)
Kabelwerk Eupen AG
1 (3)
4.1
5.85 - 7.125
(1)
(2)
4,58 (1.40)
4,51 (1.37)
4,44 (1.35)
4,38 (1.33)
4,32 (1.32)
4,27 (1.30)
4,22 (1.29)
4,17 (1.27)
4,13 (1.26)
4,09 (1.25)
4,06 (1.24)
4,03 (1.23)
3,99 (1.22)
Group velocity
%
Av. Power(2)
kW
70.2
71.4
72.5
73.6
74.5
75.5
76.3
77.1
77.9
78.6
79.3
80.0
80.6
4.61
4.69
4.76
4.83
4.90
4.96
5.01
5.07
5.12
5.17
5.21
5.25
5.30
CONNECTOR
ACCESSORIES
EU63-P-CPR137-G
Features
Description
Flange types
PDR 70
CPR 137-G
UDR 70*
CPR 137-F*
* on request
Technical characteristics
Frequency range (GHz)
Recommended pressure bar (psi)
Gas port thread
Temperature range C (F)
Connector material
VSWR
Reference
Flaring Tool
EU-FT63-P
Bending tool
see page 18
Saw guide
EU-SG63
EU-SH63
Pressure window
see page 20
Twist flex
see page 21
Grounding kit
EU-GK63
Fixing Clamps
see page 22
Hoisting Grips
EU-HG64
Weatherproofing solutions
see page 23
Dehydrator
see page 24
EU-FGK63
EU-HGK63
* Use shim when mating two PDR flanges. Not required when mating
PDR/UDR. Order separately.
** Use full-thickness gasket (supplied with connector) when mating two CPR-G
flanges. Use half-thickness gasket (order separately) when mating CPR-G
with CPR-F.
5.850 - 7.125
0,25 (3.6)
P 1/8
-40 / +80 (-40 / +176)
brass
< 1.03
References
Flange type
Sealing Method
Reference
PDR70
Threaded gasket
EU63-P-PDR70
CPR137-G
Threaded gasket
EU63-P-CPR137-G
Kabelwerk Eupen AG
11
EU 77
PE Jacket
EU 77
Waveguide type:
FRNH Jacket
EU 77-FR
Waveguide type:
on request
CHARACTERISTICS
Construction
Description
Conductor
Material
Elliptical mm (in)
Jacket
Material
Dimensions mm (in)
Thickness mm (in)
Electrical
Corrugated elliptical copper tube
copper
40,95 x 22,75 (1.61 x 0.90)
Frequency
Attenuation(1)
GHz
dB/100m (dB/100ft)
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1
8.2
8.3
8.4
8.5
Mechanical
200 (7.9)
500 (19.7)
250 (9.8)
600 (23.6)
3 (1)
60 (197)
0,7 (0.47)
1200 (47)
0,5 (7.3)
12
Kabelwerk Eupen AG
1 (3)
5.0
7.125 - 8.5
(1)
(2)
6,65 (2.03)
6,56 (2.00)
6,48 (1.97)
6,40 (1.95)
6,33 (1.93)
6,27 (1.91)
6,21 (1.89)
6,15 (1.87)
6,10 (1.86)
6,05 (1.84)
6,00 (1.83)
5,96 (1.82)
5,91 (1.80)
5,87 (1.79)
5,84 (1.78)
Group velocity
%
Av. Power(2)
kW
71.0
72.0
72.9
73.7
74.5
75.3
76.0
76.8
77.4
78.1
78.7
79.3
79.8
80.4
80.9
2.88
2.92
2.96
2.99
3.03
3.06
3.09
3.12
3.14
3.17
3.20
3.22
3.24
3.26
3.28
CONNECTOR
ACCESSORIES
EU77-P-CPR112-G
Features
Description
Flange types
PDR 84
CPR 112-G
UDR 84*
CPR 112-F*
* on request
Technical characteristics
Frequency range (GHz)
Recommended pressure bar (psi)
Gas port thread
Temperature range C (F)
Connector material
VSWR
Reference
Flaring Tool
EU-FT77-P
Bending tool
see page 18
Saw guide
EU-SG77
EU-SH77
Pressure window
see page 20
Twist flex
see page 21
Grounding kit
EU-GK77
Fixing Clamps
see page 22
Hoisting Grips
EU-HG77
Weatherproofing solutions
see page 23
Dehydrator
see page 24
EU-FGK77
EU-HGK77
* Use shim when mating two PDR flanges. Not required when mating
PDR/UDR. Order separately.
** Use full-thickness gasket (supplied with connector) when mating two CPR-G
flanges. Use half-thickness gasket (order separately) when mating CPR-G
with CPR-F.
7.125 - 8.5
0,25 (3.6)
P 1/8
-40 / +80 (-40 / +176)
brass
< 1.03
References
Flange type
Sealing Method
Reference
PDR84
Threaded gasket
EU77-P-PDR84
CPR112-G
Threaded gasket
EU77-P-CPR112-G
Kabelwerk Eupen AG
13
EU 90
PE Jacket
EU 90
Waveguide type:
FRNH Jacket
EU 90-FR
Waveguide type:
on request
CHARACTERISTICS
Construction
Description
Electrical
Corrugated elliptical copper tube
Outer conductor
Material
Ellipical mm (in)
Jacket
Material
Diameter mm (in)
Thickness mm (in)
copper
30,2 x 17,1 (1.19 x 0.67)
Frequency
Attenuation(1)
GHz
dB/100m (dB/100ft)
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
11.0
11.1
11.2
11.3
11.4
11.5
11.6
11.7
Mechanical
150 (5.9)
300 (11.8)
200 (7.9)
500 (19.7)
3 (1)
60 (197)
0,5 (0.34)
1200 (47)
0,5 (7.3)
14
Kabelwerk Eupen AG
1 (3)
6.75
10.2 - 11.7
(1)
(2)
10,08 (3.07)
10,01 (3.05)
9,94 (3.03)
9,87 (3.01)
9,81 (2.99)
9,74 (2.97)
9,68 (2.95)
9,63 (2.93)
9,57 (2.92)
9,52 (2.90)
9,47 (2.89)
9,43 (2.87)
9,38 (2.86)
9,34 (2.85)
9,30 (2.83)
9,26 (2.82)
Group velocity
%
Av. Power(2)
kW
75.0
75.5
76.1
76.6
77.1
77.6
78.1
78.5
79.0
79.4
79.8
80.2
80.6
81.0
81.3
81.7
1.58
1.59
1.60
1.61
1.62
1.63
1.64
1.65
1.66
1.67
1.68
1.69
1.70
1.70
1.71
1.72
CONNECTOR
ACCESSORIES
EU90-P-CPR90-G
Features
Description
Flange types
PDR 100
CPR 90-G
UDR 100*
CPR 90-F*
* on request
Technical characteristics
Frequency range (GHz)
Recommended pressure bar (psi)
Gas port thread
Temperature range C (F)
Connector material
VSWR
Reference
Flaring Tool
EU-FT90-P
Bending tool
see page 18
Saw guide
EU-SG90
EU-SH90
Pressure window
see page 20
Twist flex
see page 21
Grounding kit
EU-GK85
Fixing Clamps
see page 22
Hoisting Grips
EU-HG85
Weatherproofing solutions
see page 23
Dehydrator
see page 24
EU-FGK90
EU-HGK90
* Use shim when mating two PDR flanges. Not required when mating
PDR/UDR. Order separately.
** Use full-thickness gasket (supplied with connector) when mating two CPR-G
flanges. Use half-thickness gasket (order separately) when mating CPR-G
with CPR-F.
10.2 - 11.7
0,25 (3.6)
P 1/8
-40 / +80 (-40 / +176)
brass
< 1.03
References
Flange type
Sealing Method
Reference
PDR100
Threaded gasket
EU90-P-PDR100
CPR90-G
Threaded gasket
EU90-P-CPR90-G
Kabelwerk Eupen AG
15
EU 127
PE Jacket
EU 127
Waveguide type:
FRNH Jacket
EU 127-FR
Waveguide type:
on request
CHARACTERISTICS
Construction
Description
Electrical
Corrugated elliptical copper tube
Outer conductor
Material
Ellipical mm (in)
Jacket
Material
Diameter mm (in)
Thickness mm (in)
copper
25,9 x 14,7 (1.02 x 0.58)
Frequency
Attenuation(1)
GHz
dB/100m (dB/100ft)
11.7
11.8
11.9
12.0
12.1
12.2
12.3
12.4
12.5
12.6
12.7
12.8
12.9
13.0
13.1
13.2
Mechanical
125 (4.9)
250 (9.8)
150 (5.9)
400 (15.7)
3 (1)
60 (197)
0,36 (0.24)
bar (psi)
16
Kabelwerk Eupen AG
1000 (39)
0,5 (7.3)
1 (3)
7.9
11.7 - 13.25
(1)
(2)
12,41 (3.78)
12,33 (3.76)
12,26 (3.74)
12,18 (3.71)
12,11 (3.69)
12,04 (3.67)
11,98 (3.65)
11,91 (3.63)
11,85 (3.61)
11,80 (3.60)
11,74 (3.58)
11,69 (3.56)
11,63 (3.55)
11,58 (3.53)
11,54 (3.52)
11,49 (3.50)
Group velocity
%
Av. Power(2)
kW
74.9
75.4
75.9
76.3
76.8
77.2
77.7
78.1
78.5
78.8
79.2
79.6
79.9
80.3
80.6
80.9
1.16
1.17
1.18
1.19
1.19
1.20
1.21
1.21
1.22
1.23
1.23
1.24
1.24
1.25
1.25
1.26
CONNECTOR
ACCESSORIES
EU127-P-CPR75-G
Features
Description
Flange types
PBR 120
WR 75 (CPR75-G)
(pressurable
cover flange)
UBR 120*
WR 75* (CPR75-F)
(cover flange)
* on request
Technical characteristics
Frequency range (GHz)
Recommended pressure bar (psi)
Gas port thread
Temperature range C (F)
Connector material
VSWR
Reference
Flaring Tool
EU-FT127-P
Bending tool
see page 18
Saw guide
EU-SG127
EU-SH127
Pressure window
see page 20
Twist flex
see page 21
Grounding kit
EU-GK127
Fixing Clamps
see page 22
Hoisting Grips
EU-HG127
Weatherproofing solutions
see page 23
Dehydrator
see page 24
EU-FGK127
EU-HGK127
* Use shim when mating two PDR flanges. Not required when mating
PDR/UDR. Order separately.
** Use full-thickness gasket (supplied with connector) when mating two CPR-G
flanges. Use half-thickness gasket (order separately) when mating CPR-G
with CPR-F.
10.2 - 11.7
0,25 (3.6)
P 1/8
-40 / +80 (-40 / +176)
brass
< 1.05
References
Flange type
Sealing Method
Reference
PBR120
Threaded gasket
EU127-P-PBR120
CPR75-G
Threaded gasket
EU127-P-CPR75-G
Kabelwerk Eupen AG
17
ACCESSORIES FOR
WAVEGUIDE
1. Bending tool
18
Waveguide type
Ref.
Waveguide type
Ref.
EU 63
EU 77
EU 90
EU 127
EU-BTE63-77
EU-BTE63-77
EU-BTE90-127
EU-BTE90-127
EU 63
EU 77
EU 90
EU 127
EU-BTH63-77
EU-BTH63-77
EU-BTH90-127
EU-BTH90-127
Kabelwerk Eupen AG
2. Flaring tool
FLARING TOOL
Waveguide type
Ref. Tool
EU 63
EU 77
EU 90
EU 127
EU-FT63
EU-FT77
EU-FT90
EU-FT127
EU-SG63
EU-SG77
EU-SG90
EU-SG127
Kabelwerk Eupen AG
19
3. Shim
Shims are required when matching flanges PDR to
PDR or PBR to PBR. They are not required when
matching PDR to UDR or PBR to UBR. In all cases
they can be used to improve electromagnetic sealing.
Ordered separately.
Flange type
Ref.
EU 63
EU 77
EU 90
EU 127
PDR
PDR
PDR
PBR
EU-SH63
EU-SH77
EU-SH90
EU-SH127
4. Pressure windows
Pressure windows must be installed as close as possible to the antenna input, if antenna feed is not pressurized or does not have a built-in window.
PRESSURE WINDOWS
Connector type
Waveguide type
Thickness
Flange type
Ref.
EUROPE
EU 63
2 mm
flat/flat
EU-PW63-UU70*
EU 63
6 mm
flat/grooved
EU-PW63-UP70**
EU 77
2 mm
flat/flat
EU-PW77-UU84*
USA
UDR/UDR
UDR/PDR
CPR-F/CPR-F
##
CPR-F/CPR-G
**
#
20
Kabelwerk Eupen AG
EU 90
2 mm
flat/flat
EU-PW90-UU100*
EU 127
2 mm
flat/flat
EU-PW127-UU120*
EU 63
1/4
flat/flat
EU-PW63-FF137#
EU 63
1/4
flat/grooved
EU-PW63-FG137##
EU 77
1/4
flat/flat
EU-PW77-FF112#
EU 77
1/4
flat/grooved
EU-PW77-FG112##
EU 90
1/4
flat/flat
EU-PW90-FF90#
EU 90
1/4
flat/grooved
EU-PW90-FG90##
EU 127
1/4
flat/flat
EU-PW127-FF75#
EU 127
1/4
flat/grooved
EU-PW127-FG75##
5. Twist Flex
Twist flex sections can be used as jumper on the
antenna side as well as on the radio side.
length
lenght
TWIST FLEX
Connector type
Waveguide type
Length
Flange type
Ref.
EUROPE
EU 63
100 cm
flat/grooved*
EU-TF63-UDR-PDR70-100
EU 77
100 cm
flat/grooved*
EU-TF77-UDR-PDR84-100
EU 90
66 cm
flat/grooved*
EU-TF90-UDR-PDR100-66
EU 127
66 cm
flat/grooved*
EU-TF127-UBR-PBR120-66
USA
*
#
EU 63
36
flat/grooved
EU-TF63-CPRF-CPRG137-36
EU 77
36
flat/grooved#
EU-TF77-CPRF-CPRG112-36
EU 90
24
flat/grooved
EU-TF90-CPRF-CPRG90-24
EU 127
24
flat/grooved#
EU-TF127-CPRF-CPRG75-24
UDR/PDR
CPR-F/CPR-G
Kabelwerk Eupen AG
21
6. Grounding Kits
GROUNDING KITS
Waveguide type
Ref.
EU 63
EU 77
EU 90
EU 127
EU-GK63
EU-GK77
EU-GK85
EU-GK127
7. Fixing Clamps
a. Butterfly Hanger
BUTTERFLY HANGER
Waveguide type
Ref.
EU 63
EU 77
EU 90
EU 127
EU-BH63-NH
EU-BH77-NH
EU-BH85-NH
EU-BH127-NH
B. CLAMPS
CLAMPS
22
Waveguide type
Ref.
EU 63
EU 77
EU 90
EU 127
EU-CC63
EU-CC77
EU-CC90
EU-CC127
Kabelwerk Eupen AG
8. HOISTING GRIPS
HOISTING GRIPS
Waveguide type
Ref.
EU 63
EU 77
EU 90
EU 127
EU-HG63
EU-HG77
EU-HG85
EU-HG127
9. ADDITIONAL
WEATHERPROOFING SOLUTIONS
A. TAPE KIT
Tape Kit Ref.: F722-996
One Kit is sufficient for:
TAPE KIT
Connector type
EU 63
EU 77
EU 90
EU 127
Single connector
Connector pair
1
0.75
1.5
1
1.5
1
2
1
Ref.
EU 63
EU 77
EU 90
EU 127
EU-CS63
EU-CS77
EU-CS90
EU-CS127
23
10. Dehydrator
Humidity, the critical issue
In theory waveguides and cables are airtight, however practice shows humidity leakage problems occur
relatively soon after installation. Wind and temperature fluctuations cause pressure differences between
inside and outside so that wet, ambient air enters the
system.
Etsiline pressurizers use porous materials (desiccants) to absorb the water molecules from the air
flow. Two desiccant adsorbers guarantee a continuous operation. When one adsorber is removing
moisture the other one is being regenerated.
24
Kabelwerk Eupen AG
DEHYDRATOR
Etsiline 32 and 52
Model A
20 - 30 (0.3 - 0.4)
40 - 80 (0.6 - 1.2)
6
mbar (psi)
mbar (psi)
Ambient air
Fully automatic and continuous
Indoors
IP 40
-10 to +45 (14 to 113)
max. 95%
< -40 (< -40)
110V, 230V, 50/60 Hz
24V, 48V, 60V DC
6 hours
3 hours
depending on requirements
C (F)
C (F)
Drying time
Regeneration time
Stand-by time
TECHNICAL DATA
Model
delair Etsiline 32
delair Etsiline 52
Configuration
ETSI-rack
Outlet
Power consumption
Sound
Dimensions
Weight
capacity
Drying
Regeneration
Stand-by
level
Width
Depth
Height
l/h (ft3/h)
dB(A)
mm (inch)
mm (inch)
mm (inch)
kg (lb)
30 (1.1)
53
< 43
10 (22)
535 (21.1)
200 (7.9)
221,5 (8.7)
19 rack
482,6 (19.0)
200 (7.9)
221,5 (8.7)
Wall mounting
420 (16.5)
234 (9.2)
221,5 (8.7)
Floor/table mounting
420 (16.5)
200 (7.9)
243,5 (9.6)
535 (21.1)
200 (7.9)
221,5 (8.7)
19 rack
482,6 (19.0)
200 (7.9)
221,5 (8.7)
Wall mounting
420 (16.5)
234 (9.2)
221,5 (8.7)
Floor/table mounting
420 (16.5)
200 (7.9)
243,5 (9.6)
ETSI-rack
50 (1.8)
53
< 43
10 (22)
Kabelwerk Eupen AG
25
The standard drum sizes used for the different waveguide types are shown in the table below.
w
A
Waveguide length
Outer dim. *
D
Drum dim. *
d
Outer width
W
Drum type
m (ft)
cm (inch)
cm (inch)
cm (inch)
EU 63
HL 20S*
HL 20B*
HL 20S
HL 20B
270 (886)
500 (1640)
400 (1312)
700 (2296)
200
200
200
200
(79)
(79)
(79)
(79)
160
160
140
140
(63)
(63)
(63)
(63)
74 (29)
116 (46)
74 (29)
116 (46)
EU 77
HL 17S
HL 20S*
HL 20B*
HL 20S
HL 20B
330
320
550
550
950
(1082)
(1050)
(1804)
(1804)
(3116)
170
200
200
200
200
(67)
(79)
(79)
(79)
(79)
140
160
160
140
140
(63)
(63)
(63)
(55)
(55)
74 (29)
74 (29)
116 (46)
74 (29)
116 (46)
EU 90
HL 17S
HL 17B
HL 20S*
HL 20B*
HL 20S
380 (1246)
570 (1870)
600 (1968)
1100 (3608)
1050 (3444)
170
170
200
200
200
(67)
(67)
(79)
(79)
(79)
140
140
160
160
140
(55)
(55)
(63)
(63)
(55)
74 (29)
102 (40)
74 (29)
116 (46)
74 (29)
EU 127
HL 17S
HL 17B
HL 20S*
HL 20B*
500 (1640)
800 (2624)
800 (2624)
1200 (3936)
170
170
200
200
(67)
(67)
(79)
(79)
140
140
160
160
(55)
(55)
(63)
(63)
74 (29)
102 (40)
74 (29)
116 (46)
Waveguide type
* drums with 160 cm (63 inch) inner diameter will be discontinued in the near future
26
Kabelwerk Eupen AG
Packing information
Inner width
w
Shaft hole
A
Drum freight
Volume
Drum weight
drum/battened drum
Waveguide weight
cm (inch)
cm (inch)
m3 (ft3)
kg (lb)
kg/km (lb/100ft)
62 (24)
104 (41)
62 (24)
104 (41)
9
9
9
9
(3.5)
(3.5)
(3.5)
(3.5)
3 (106)
4,7 (166)
3 (106)
4,7 (166)
390/470
440/556
390/470
440/556
(858/1034)
(968/1223)
(858/1034)
(968/1223)
840
840
840
840
(56.3)
(56.3)
(56.3)
(56.3)
64,4 (25)
62 (24)
104 (41)
62 (24)
104 (41)
9
9
9
9
9
(3.5)
(3.5)
(3.5)
(3.5)
(3.5)
2,2 (78)
3 (106)
4,7 (166)
3 (106)
4,7 (166)
332/412 (730/906)
390/470 (858/1034)
440/556 (968/1223)
390/470 (858/1034)
440/556 (968/1223)
700
700
700
700
700
(46.9)
(46.9)
(46.9)
(46.9)
(46.9)
64,4 (25)
92,4 (36)
62 (24)
104 (41)
62 (24)
9
9
9
9
9
(3.5)
(3.5)
(3.5)
(3.5)
(3.5)
2,2 (78)
3 (106)
3 (106)
4,7 (166)
3 (106)
332/412 (730/906)
380/465 (836/1023)
390/470 (858/1034)
440/556 (968/1223)
390/470 (858/1034)
500
500
500
500
500
(33.5)
(33.5)
(33.5)
(33.5)
(33.5)
64,4 (25)
92,4 (36)
62 (24)
104 (41)
9
9
9
9
(3.5)
(3.5)
(3.5)
(3.5)
2,2 (78)
3 (106)
3 (106)
4,7 (166)
332/412 (730/906)
380/465 (836/1023)
390/470 (858/1034)
440/556 (968/1223)
360
360
360
360
(24.1)
(24.1)
(24.1)
(24.1)
Kabelwerk Eupen AG
27
2006-02-02-USA
Tel.: +32(0)87.59.70.00
Fax: +32(0)87.59.71.00