Gas and Electric Dryer: Product Model Numbers WED8000D, WED8500D, WGD8000D, WGD8500D, WED8700E, WGD8700E
Gas and Electric Dryer: Product Model Numbers WED8000D, WED8500D, WGD8000D, WGD8500D, WED8700E, WGD8700E
Gas and Electric Dryer: Product Model Numbers WED8000D, WED8500D, WGD8000D, WGD8500D, WED8700E, WGD8700E
Back view
561/4"
(1428 mm)
Door Opened
3213/16"
(821 mm)
29"
(737 mm)
Door Closed
57/8"
(150 mm)
4213/16"
(1987 mm)
41/2"
(115 mm)
3"
(77 mm)
1"
(25 mm)
113/8"
35/8"
(289 mm) (93 mm)
Bottom view
13/8"
141/2"
(35 mm) (370 mm)
31/2"
(93 mm)
81/2"
(218 mm)
18"/18"*
(457 mm)
3"/3"
(76 mm) 48"2/48"2
(310 cm2)
143/8"
(365 mm)
NOTE: Most installations require a minimum
of 6" (152 mm) clearance behind dryer for
exhaust vent with elbow. See
Venting Requirements.
3"/3"
(76 mm)
6"/0"*
(152 mm)
24"2/24"2
(155 cm2)
1"/1"*
(25 mm)
1"/0"*
(25 mm)
*Recommended/Minimum spacing
W10725269B
05/2015
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be
" IPS. When acceptable to the gas supplier and local codes, 38" approved tubing may be used for lengths under 20 ft (6.1 m). For
lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An
individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code
ANSI Z223.1.
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit
are recommended.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm)
diameter vent is required. Rigid or flexible metal exhaust vent
must be used. Do not use plastic or metal foil vet. Exhaust hood
must be at least 12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Exhaust hoods:
Recommended Styles:
Box Hood
Acceptable Style:
Angled Hood
path outdoors.
Type of vent
Angled
hoods
Rigid metal
64 ft. (20 m)
Rigid metal
54 ft. (16.5 m)
Rigid metal
44 ft. (13.4 m)
Rigid metal
35 ft. (10.7 m)
Rigid metal
27 ft. (8.2 m)
turns.
room as possible.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.