Professional Documents
Culture Documents
189 Specification
189 Specification
189 Specification
Features
l
l
l
l
l
Specifications:
Measurements
Range
Measuring
range
Resolution
DCV
5.0000V
0.0001V
50.000V
0.001V
Input impedance
10M
500.00V
0.01V
1000.0V
0.1V
50.000mV
0.001mV
500.00mV
0.01mV
DCmV
2200.0mV
ACV
www.ttbvision.com
Input impedance
approx. 100M
0.1mV
5.0000V
0.0001V
50.000V
0.001V
500.00V
0.01V
760.0V
0.1V
Input
impedance
10M /
50pF
CF3
187
20Hz
30kHz
ACmV
OHM
DCA
DCmA
DCuA
ACmA
ACuA
FREQ
www.ttbvision.com
50.000mV
0.001mV
500.00mV
0.01mV
500.00
0.01
5.0000K
0.0001K
50.000K
0.001K
500.00K
0.01K
5.0000M
0.0001 M
50.000M
0.001 M
500.0M
0.1 M
5.0000A
0.0001 A
20.000A
0.001 A
50.000mA
0.001mA
500.00mA
0.01 mA
500.00uA
0.01 uA
5000.0uA
0.1 uA
5.0000A
0.0001 A
50.000mA
0.001mA
500.00mA
0.01 mA
500.00uA
0.01uA
50000uA
0.1uA
9.9999Hz
0.0001Hz
99.999Hz
0.001Hz
999.99Hz
0.01Hz
Input
impedance
1M / 50pF
10
110%
Range)
189
20Hz
100kHz
5
110%
Range)
Voltage Drop
1.8 mV/mA
Voltage Drop
103uV/uA
9.9999KHz
0.0001KHz
99.999KHz
0.001KHz
999.99KHz
0.01KHz
9.9999MHz
99.999MHz
0.0001MHz
0.001MHz
DUTY
0.1%99.9%
0.1%
0.5Hz1KHz
Square Wave
199.99ms
0.01ms
1999.9ms
0.1ms
DIODE
2.2000V
0.0001V
CHCNT
500.0
0.1
CAP
9.999nF
0.001nF
99.99nF
0.01nF
999.9nF
0.1nF
9.999F
0.001uF
99.99F
0.01uF
999.9F
0.1uF
9.999mF
0.001mF
99.99mF
0.01mF
PULSE
TC
www.ttbvision.com
-40C
1760C
-40C
1760C
-270.0
1370.0
1C
0.1C
ITS-90
RTD
-270.0
720.0
0.1C
-210.0
850.0
0.1C
-270.0
400.0
0.1C
-270.0
1300.0
0.1C
4001800
1C
Pt100
-200.0
850.0
0.1C
Pt1000
-200.0
630.0
0.1C
Pt100-385
Other Features:
l
DC Voltage measurement
CMRR50Hz / 60Hz 120dB
SMRR50Hz / 60HzRs=1k 80dB
AC Voltage measurement
CMRR50Hz / 60HzRs=1k 80 dB
A residual reading with input shorted, will not affect stated accuracy above 5 % of range.
OHM measurement
For relative humidity greater than 70 %, resistance accuracy is 0.5 % over 1 Mand 2.5 %
over 10 M.
Internal temperature compensation sensor RJC:
temperature range: -10 ~ 50, compensation error 0.5 , compensation time for 10
seconds each time
Maximum voltage between any Terminal and Earth Ground :
1000V DC / AC rms
Fuse protection for mA input: 500 mA / 250V FAST fuse
fuse protection for 20A input: 20 A / 250V FAST fuse
Can be as high as 20 A continuous measurement of the current, if the signal detected in 10
A ~ 20 A of maintaining maximum of 30 seconds, then specified the need to increase the
accuracy of 0.5%
Real-Time Clock
1min / 1month
Temp. Influence 50 ppm per C
Measured rate
Functional range
Measuring rate
FAST
www.ttbvision.com
SLO
W
SMOOTH
14
14
1.8
1.8
General Specifications:
l
Operating Temperature and Humidity
0 to 50oC,(no condensation 10oC) 85%RH
l
Storage Temperature and Relative Humidity
-20oC to 60oC90%RH
l
Altitude
2000m max. above sea level
l
Rated transient over-voltage
6KV1.2*50usCAT, CAI , CAT peak measurement
l
Vibration and Shock
Random 2g, 5 to 500Hz
1 meter drop test
l
Period of calibration and warm-up time
Accuracy is specified for a period of one year after calibration or other
Warm-up time is 10 minutes or other
l
Display and LED
* LCD36.368.0mm
* white LEDable to set time 09999S
l
Supply
* 4 x 1.5V Alkaline batteries supply
* 4 x 1.2V Ni-Hi batteries supply
* Auto Power-offable to set time 09999minutes
l
Safety Standards
IEC 61010-1, 2000
Overvoltage category III (Max. input voltage:AC/DC600V)
Overvoltage category II (Max. input voltage:AC/DC1000V)
Pollution degree 2
l
Weight and Size
205 95 42mm approximate 500g
www.ttbvision.com