Professional Documents
Culture Documents
Photo-Electric Sensors: Selection Guide
Photo-Electric Sensors: Selection Guide
Photo-Electric Sensors: Selection Guide
Photo-electric sensors
Osiris
Format
Universal
Design 18
Osiconcept
Dimensions (w x h x d) in mm
Metal
0.12
0.12
0.40
3
20
0.40
3
20
c
a
z
IP 65
IP 67
p
IP 65
IP 67
p
Pre-cabled
Connector
Screw terminals
p
p
p
p
XUB 0A
XUB 0B
1/24
1/24
Case
Maximum
sensing
distance (m)
related to
system
Degree of protection
Supply
Output
Connection
Type reference
1/2
Selection guide
Photo-electric sensors
Osiris
Universal
Miniature design
Compact design, 50 x 50
Compact design
Osiconcept
Osiconcept
Osiconcept
Pre-cabled: 12 x 34 x 20
M8 connector: 12 x 45 x 20
Plastic
18 x 50 x 50
30 x 92 x 77
10 x 40 x 65 (amplifier)
0.10
0.28
1.3
0.55
4
14
1.2
5.7
35
3
15
60
0.0060.070 (2)
0.0501.5 (2)
IP 65
IP 67
p
IP 65
IP 65 (amplifier)
IP 64 (fibres)
p
p
p
p
Solid-state (PNP and NPN)
or 1 NC/NO relay (1)
NO or NC (programmable)
p
p
IP 65
IP 67
p
p
Solid-state (PNP and NPN)
or 1 NC/NO relay (1)
NO or NC (programmable)
p
p
XUM 0A
XUK 0A
XUX 0A
XUD A2
1/30
1/34
1/38
Plastic (amplifier)
p
p
1/3
Selection guide
Photo-electric sensors
Osiris
Optimum
Format
Design 18
Dimensions (w x h x d) in mm
Case
Plastic
Metal
IP 65
IP 67
IP 65
IP 67
p
p
p
p
Type reference
XUB pA
XUB pB
Page
1/26
1/28
Maximum
sensing
distance (m)
related to
system
Degree of protection
Supply
c
a
z
Output
Connection
Pre-cabled
Connector
Screw terminals
1/4
Selection guide
Photo-electric sensors
Osiris
Miniature design
Compact design, 50 x 50
Optimum
Compact design
12 x 34 x 27
18 x 50 x 50
30 x 92 x 77
Plastic
10 x 40 x 65 (amplifier)
Plastic (amplifier)
1.5
8
10
45
3
15
20
60
0.0060.095 (3)
0.0502 (3)
IP 65
IP 67
IP 65
IP 65
IP 67
IP 65 (amplifier)
IP 64 (fibres)
p
p
p
p
p
p
p
p
XUM pA
XUK pA
XUX pA
XUD A1
1/32
1/36
1/40
1/5
Selection guide
Photo-electric sensors
Osiris
Recommended applications
Application
Other formats
Assembly
General use
Format
Compact design
Design 8
Frame design
Dimensions (w x h x d) in mm
18 x 70 x 35
8, threaded
M8 x 1
L: 40
15 x 50 x 108
15 x 86 x 131
25 x 230 x 205/265/335
Case
Plastic
Metal
Diffuse
0.7
0.05
Polarised reflex
4 (with 80 mm reflector)
Reflex
Thru-beam
6 (with 80 mm reflector)
8
0.03-0.06-0.12-0.18-0.25 (1)
IP 67
IP 65 (1)
IP 67 (1)
IP 65
p
p
Solid-state
p
p
p
p
XUL
XUA
XUV F
1/64
1/66
Sensing
distance (m)
related to
system
Degree of protection
Supply
c
a
z
Output
Connection
Type reference
Page
1/6
Pre-cabled
Connector
Screw terminals
1/54
(1) Depending on model.
Selection guide
Photo-electric sensors
Osiris
Application
Packaging
Detection of any transparent
object
Detection of
water and
aqueous
liquids
Luminescence sensors
Detection of invisible
reference marks, markings,
adhesives, varnishes, etc.
Sensitive to the bluing agents
generally present in inks,
adhesives, varnishes, etc.
Design 18
Compact
design,
50 x 50
18 x 50 x 50
Compact
design
Fork design
Compact
design
13 x 47 x 23
20 x 90 x 26
50 x 50 x 25
Plastic
Plastic
Metal
0...1,4 (with
reflector)
Compact
Compact
design or fibre design
design
30 x 80 x 57
50 x 50 x 15
25 x 92 x 54
Compact
design
Design 18
Compact
design
30 x 87 x 63
31 x 81 x 58
31 x 81 x 58
Plastic
Metal
Plastic
Metal
18,
threaded
M18 x 1
L: 82
Metal
0.020
0.019
0.009
0.02
0.009
0.0400.060
0.0400.250
(1)
1.5
50
0.002
IP 65
IP 67
IP 65
IP 65
IP 65
IP 65
IP 65 (2)
IP 67 (2)
IP 65
IP 67
IP 67
IP 67
Solid-state
(PNP)
Solid-state
(PNP or NPN)
18, threaded
M18 x 1
L: 64, 78 or 92
(2)
Plastic or
stainless steel
(2)
p
p
p
p
XUB T
XUK T
XUM W
XUV K
XUK C
XUR C
XUK R
XUR K
XU5 M
XUR U
1/72
1/74
1/76
1/78
1/80
1/82
1/84
1/84
1/68
1/70
(1) Depending on fibres.
(2) Depending on model.
1/7
Photo-electric sensors
Osiris
Recommended applications
Application
Materials handling
Diffuse with
background
suppression
Thru-beam
with high
excess gain
Thru-beam
Fork type
laser for very
long sensing
distances
(100 m)
High
precision,
detection of
any dark or
shiny object,
including
small sized
Detection of
objects in
difficult
environments
(smoke, dust,
mist, etc.).
Measuring
opacity
Transtorage,
storage,
travelling
cranes,
implementation of long
distance
parallel beam
barriers
(up to 20 m)
Design 18
Design 18
Dimensions (w x h x d) in mm
Compact
design,
50 x 50
18 x 50 x 50
Case
Format
Compact
design
Sensing of
flags in lifts
and
transtorers.
Integrated
amplifier
Fork design
Plastic
18, threaded 27 x 85 x 61
M18 x 1
L: 82
Metal
Plastic
18, threaded
M18 x 1
L: 82
Metal
18, threaded 14 x 58 x 68
M18 x 1
L: 76
Plastic
0.050.4
0.200.80
50
100
0.03
IP 65
IP 67
IP 67
IP 67
IP 67
IP 54
Solid-state
Analogue (PNP)
(PNP or NPN)
Solid-state
(PNP)
+ analogue
p
p
Type reference
XUK 8
XU5 M
XUJ
XU2 M
XU2
XUV
Page
1/86
1/88
1/90
1/92
1/94
1/96
Sensing
distance (m)
related to
system
Degree of protection
Supply
c
a
z
Output
Connection
1/8
Pre-cabled
Connector
Screw terminals
Selection guide
Photo-electric sensors
Osiris
With stability
LED.
With alarm
output (for
XUC pAK only)
Application
18 AC/DC
Monitoring of
movement, relay
output
Surveillance
using
single-beam light
curtains (1)
Design 18
Accessories
Design 18
light curtains
Monitoring of
movement with
audible
signalling
(buzzer), relay
output
Accessories
Safety
Compact design
Compact design
45 x 95 x 44
18 x 70 x 45
Plastic
Plastic
1.2
50
IP 67
Design 18
27 x 85 x 61
18, threaded
M18 x 1
L: 64...92
Stainless steel
18, threaded
M18 x 1
L: 62...88
Stainless steel
18, threaded
M18 x 1
L: 82...110
Metal
18, threaded
M18 x 1
L: 6395 (2)
Metal or plastic
0.12
0.3
2
15
0.10
2
4
15
0.12
0.4
2
15
8 or 50 (2)
IP 67
IP 40
IP 67, IP 69K
IP 67
IP 67
IP 67 (XU2 S)
p (XU2 S)
p (XPS CE)
Solid-state PNP or
NPN (XUC pAK)
1 C/O relay
(XUC pAR)
p
p
1 C/O relay
1 N/O relay
Solid-state
p
p
p
p
p
p
p (XU2 S)
p (XU2 S)
p (XPS CE)
XUC
XUL
XUJ B
XUB 0Sp
XUp N18
XUp M18
XUZ
XU2 S +
XPS CE
1/60
1/98
1/100
1/102
1/104
1/108
1/110
Refer to our
Safety solutions
catalogue
(1) Preventa XPS-CE safety module + 1 to 4 thru-beam pairs of photo-electric sensors XU2 S.
1/9
General
Photo-electric sensors
Osiris
Principle
Max. sensing
distance
Max. sensing
distance
Max. sensing
distance
Max. sensing
distance
b Irrespective of the detection mode used (diffuse, reflex, thru-beam, etc), the
output signals become either N/O or N/C (1).
NO
NC
Object present
(1) The product is delivered in N/O configuration. N/O or N/C is selected by simply pressing the
Teach mode button.
NO
NC
Mounting accessories
Telemecanique brand proposes a complete, inexpensive range of mounting and
protection accessories (conventional or 3D brackets and clamps) providing solutions
to all setting-up and adjustment problems.
1/10