Laboratory

N.P.K. Founders (Test & Calibration Lab Division), Plot No A-92/93, H


Block, M.I.D.C., Pimpri, Pune, Maharashtra

Accreditation Standard

ISO/IEC 17025: 2005

Discipline
Certificate Number
Last Amended on

Mechanical Calibration
C- 0324
-

Quantity Measured/
Instrument

I.

PRESSURE / VACUUM

1.

ANALOGUE/DIGITAL
PRESSURE GAUGES,
TRANSMITTER/
TRANSDUCER WITH
INDICATOR

2.

Range / Frequency

Issue Date
Valid Until
Page
*Calibration
Measurement Capability
()

22.05.2014
21.05.2016
1 of 2

Remarks

0 to 1.5 kg/cm2

1.14% rdg

Using Digital Pressure


Gauge Transmitter with
Indicator and Pneumatic
Pump comparator

ANALOGUE/DIGITAL
VACUUM GAUGES,
TRANSMITTER/TRANSDUCER
WITH INDICATOR

0 to -0.86 kg/cm2

2.13% rdg

Using Digital Vacuum


Gauge/Transmitter with
Indicator

3.

ANALOGUE /DIGITAL
PRESSURE GAUGES,
TRANSMITTER/TRANSDUCER
WITH INDICATOR

0 to 700 kg/cm2

0.75% rdg

Using Digital Pressure


Gauge/Transmitter with
Indicator

II.

ACCOUSTICS

1.

SOUND LEVEL METER$

@ 1 kHz
94dB & 114 dB

1.1 dB

Using Sound Level


Calibrator Single Point
Calibration

III.

ACCELERATION & SPEED

1.

RPM (CONTACT MODE) $

60 rpm to 6000 rpm

1.11% rdg

(NON CONTACT MODE)$

60 rpm to
99,999rpm

0.21% to 0.0013%

Using Digital RPM


Indicator. By Comparison
Method
Using Multifunction
Calibrator,
Wavetek 9100. By Direct
Method

10m to 1000 m

2.4 m

Using Dial Comparator

IV.

DIMENSION

1.

FOIL THICKNESS$
Avijit

Avijit Das
Program Manager

Ranjith Kumar D.
Convenor

Laboratory

N.P.K. Founders (Test & Calibration Lab Division), Plot No A-92/93, H


Block, M.I.D.C., Pimpri, Pune, Maharashtra

Accreditation Standard

ISO/IEC 17025: 2005

Discipline
Certificate Number
Last Amended on

Mechanical Calibration
C- 0324
-

Quantity Measured/
Instrument

2.

COATING THICKNESS
GAUGE$

3.

4.

Range / Frequency

Issue Date
Valid Until
Page
*Calibration
Measurement Capability
()

22.05.2014
21.05.2016
2 of 2

Remarks

With Feeler Gauge.


By Comparison Method
Using Thickness Foils
Spot Calibrated ,
By Comparison Method

10m to 1000 m

2.4 m

VERNIER CALIPER$
L.C. : 0.01 mm

Upto 300 mm

11.0 m

Using Caliper Checker


By Comparison Method

VERNIER HEIGHT GAUGE$


L.C. : 0.02 mm

Upto 300 mm

20 m

Using Caliper Checker

1g to 200 g

1 mg

Using E2 class weights


By Comparison Method

0.7 g/cc to 1.2 g/cc

0.005 g/cc

Using Electronic Weighing


Balance & Suspension
Arrangement. By Cuckows
Method

V.

MASS

1.

WEIGHING BALANCE

VI.

DENSITY

1.

HYDROMETER$

* Measurement Capability is expressed as an uncertainty () at a confidence probability of 95%


$
Only in Permanent Laboratory
#
The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual
environmental conditions and master equipment used.

Laboratory can also calibrate instruments/devices of coarser resolution / least count within the accredited range
using same reference standard/ master equipment under the scope of accreditation.

Avijit

Avijit Das
Program Manager

Ranjith Kumar D.
Convenor