Flexi NS - Site Folder

SITE NAME / SITE NUMBER

Nokia Siemens Networks


Flexi NS - MME Site Folder
Almadar Libya

Site Drawings

Outstanding Tasks

Site Inventory

Installation Checklist

Commissioning Checklist

Integration Checklist

Site Acceptance Certificate

Project Name:
PROJECT NAME
Site Name / Site Number:
SITE NAME / SITE NUMBER

Revision Date: September, 2013

Technical Project Management

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Revision History
Date
Sept 2013

Rev.
1

Originator
Bubun A

Summary of Change
First Version of Flexi NS Site Folder

Document Approval
Rev.

Role

Name

Signature
Date

The information in this document is subject to change without notice and describes only the product defined in the
introduction of this documentation. This document is intended for the use of Nokia Siemens Networks Almadars
only for the purposes of the agreement under which the document is submitted, and no part of it may be used,
reproduced, modified, or transmitted in any form or means without the prior written permission of Nokia Siemens
Networks. The document has been prepared to be used by professional and properly trained personnel, and the
Almadar assumes full responsibility when using it. Nokia Siemens Networks welcomes Almadar comments as part
of the process of continuous development and improvement of the documentation.
The information or statements given in this document concerning the suitability, capacity, or performance of the
mentioned hardware or software products are given as is and all liability arising in connection with such
hardware or software products shall be defined conclusively in a separate agreement between Nokia Siemens
Networks and the Almadar. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the
instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens
Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the
document.
Nokia Siemens Networks will correct errors in the document as soon as possible. IN NO EVENT WILL NOKIA
SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENT OR FOR ANY DAMAGES, INCLUDING BUT NOT
LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY MONETARY LOSSES, SUCH
AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR
DATA THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT
This document and the product it describes are considered protected by copyrights and other intellectual property
rights according to the applicable laws.
Wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation.
Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are
mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2010. All rights reserved.

Version 1.0.2

Page 2 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Table of Contents
1

SITE DRAWINGS ........................................................................................... 5

OUTSTANDING TASKS ................................................................................... 6

SITE INVENTORY .......................................................................................... 7


3.1

INSTALLATION CHECKLIST ........................................................................... 10


4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14

PREPARE FOR INSTALLATION ...................................................................... 10


PREPARE THE EQUIPMENT ROOM ................................................................. 10
UNPACK AND INSPECT THE EQUIPMENT .......................................................... 11
INSTALL THE CABINET ON EARTHQUAKE BASED FRAME ........................................ 11
CHECK THE PRE-ASSEMBLE COMPONENTS AND CABLINGS. .................................... 12
CONNECT THE GROUNDING ....................................................................... 12
CONNECT THE SITE POWER SUPPLY INPUT CABLES TO THE PDUS ............................ 13
TEST THE POWER SUPPLY .......................................................................... 13
INSTALL BLADES AND RTMS ACCORDING TO THE NETWORK ELEMENT CONFIGURATION ... 13
INSTALL THE REAR CABLE TRAY ................................................................... 14
CONNECT THE INTERNAL CABLES ................................................................. 14
MOUNT THE CABINET DOOR ....................................................................... 14
COMPLETE THE INSTALLATION .................................................................... 15
INSTALLATION CERTIFICATE OF COMPLETION ................................................... 17

COMMISSIONING CHECKLIST ....................................................................... 19


5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
5.10
5.11
5.12
5.13

CHANGES TO SITE INVENTORY...................................................................... 7

COMMISSIONING PREPARATIONS ................................................................. 19


CHECKING THE SETTINGS AND THE CONFIGURATION........................................... 20
INSPECTING THE STORAGE DEVICES.............................................................. 21
CREATING A BOOTABLE USB STICK AND COPYING A MINIDEBUGGER TO IT ................. 22
OPEN MML SESSION ............................................................................... 22
INSPECT FLEXI NS SOFTWARE VERSIONS ....................................................... 24
INSPECT I/O DEVICES ............................................................................. 24
INSPECT MAINTENANCE SYSTEM .................................................................. 25
CHECK THE HARDWARE CONFIGURATION ........................................................ 25
CHECKING UNIT DIAGNOSTICS AND WORKING STATES ........................................ 26
COPYING ADDITIONAL SOFTWARE ................................................................ 27
FINISHING COMMISSIONING ...................................................................... 27
COMMISSIONING CERTIFICATE OF COMPLETION................................................ 30

INTEGRATION CHECKLIST ............................................................................ 32


6.1
6.2
6.3

6.4
6.5
6.6
6.7
6.8
6.9

INTEGRATION CHECKS ............................................................................. 32


PREREQUISITES FOR INTEGRATION ............................................................... 33
CREATE IP CONNECTIVITY ......................................................................... 33
6.3.1 CREATING IP CONFIGURATION FOR MCHU ........................................... 33
6.3.2 CREATING IP CONFIGURATION FOR SMMU ........................................... 33
6.3.3 CREATING IP CONFIGURATION FOR CPPU ............................................ 34
SET NETWORK-SPECIFIC NUMBERS ............................................................... 34
CREATE NETWORK ELEMENT INTERFACES ........................................................ 34
CONFIGURE S6A INTERFACE ...................................................................... 34
CONFIGURE S1 AND S11 INTERFACES .......................................................... 35
CREATE PLMN ...................................................................................... 35
CREATE IMSI ANALYSIS ........................................................................... 36

Version 1.0.2

Page 3 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

6.10 SYNCHRONIZING IN FLEXI NS .................................................................... 36


6.11 INTEGRATION CERTIFICATE OF COMPLETION.................................................... 38
7

SITE ACCEPTANCE CERTIFICATE ................................................................... 40

Version 1.0.2

Page 4 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Site Drawings
Site-specific drawings that apply to Nokia Siemens Networks equipment installation
are developed by Nokia Siemens Networks Site Engineering Site Solutions and contain
site-specific installation information, such as:

Site Layout (equipment room floor plan)

Rack face drawings

Cable drawings

Version 1.0.2

Site power cabling layout

Site ground power cabling layout

Site communications cabling layout

Any additional site drawings.

Page 5 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

2
Item

Outstanding Tasks
Description of Outstanding Work

10

11

12

13

14

15

Version 1.0.2

Raised by:
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date

Completed by:
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date
Sig.
Name
Date

Page 6 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Site Inventory

3.1

Changes to Site Inventory

Record all differences and replacements in the following table:


NEW UNIT
Name / Version

Version 1.0.2

Serial Number

OLD UNIT
Name / Version

Serial Number

NSN
FAULT
REPORT #

Page 7 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Notes on Inventory
Lists:

Version 1.0.2

Page 8 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

This page left intentionally blank.

Version 1.0.2

Page 9 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Installation Checklist
The Installation Team is to carry out the Installation in accordance with the Installation
Site Requirements for Flexi NS, Unpacking ATCA Cabinets and Installing ATCA
Hardware included in Nokia Siemens Networks Flexi Network Server Operating
Documentation SAE/MME User Manual.
The Installation Team Supervisor is responsible for:

4.1

Ensuring that each team member has the correct tools, installation materials,
and User Manual.

Checking the delivery against the packing list and placing it in Section 3 of the
Site Folder.

Completing this checklist including the signature and date.

Completing the necessary Site Deficiency Reports.

Completing the necessary Fault Reports.

Informing the Installation Manager/Site Manager of work progress, including


any problems as they arise.

Completing the Certificate of Completion and placing it in Section 4.14 of the


Site Folder.

Prepare for Installation


INSTALLATION PHASE

COMPLETED

Check the availability of the documents needed for installation. Record the
shortages. Acquire the missing documents.
Check the availability of the tools needed for Installation. Acquire missing
tools.

4.2

Prepare the Equipment Room


INSTALLATION PHASE

COMPLETED

Check that the installation room is clean. Check that all basic work such as
installation of lighting, fire extinguishing, and air conditioning equipment is
completed.
Check against the floor plan for the site that all cable shelves and gratings
separate from the equipment itself are ready.
Check that the ventilation equipment has been properly installed and that the
temperature in the equipment room is within the limits allowed by the system.

Version 1.0.2

Page 10 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

INSTALLATION PHASE

COMPLETED

Check that the materials of the floors and desks in the equipment room are
anti-static (EPA). Insure anti-static wrist straps are checked and used by
Installation personnel. Provide anti-static materials and mats where
necessary.
Check the conformance of the room to the Installation floor plan drawing.
Record the differences.
Protect the gangways in the exchange room with cardboard.
Construct, measure, and mark out the positions of the cabinet (rows) and
other equipment on the floor.
Check the routes for external cabling and install cable ladders. Record the
differences to site drawings.
Make the needed additional holes in raised floors. Clean the room. Correct
installation floor plan.

4.3

Unpack and Inspect the Equipment


INSTALLATION PHASE

COMPLETED

Visually check the transport packages for external damage. Record any
possible damage.
Remove equipment from the transport packages. Check the number of cases
against the packing list. Record shortages.
Unpack the cases.
Inspect equipment for internal or external damage. Record any possible
damage.

4.4

Install the Cabinet on earthquake based frame


INSTALLATION PHASE

COMPLETED

Another document relevant for this task is Installing ATCA hardware


Remove the cabinet wheels properly
Install cabinet to the correct places appointed to the cabinets in the site floor
plan.
Attach the cabinet to the earthquake based frame
Bolt the cabinet firmly to the earthquake base frame.

Version 1.0.2

Page 11 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

INSTALLATION PHASE

COMPLETED

Check to insure that isolation pads (i.e., plastic plate) are installed between
the base frame and cabinet, and that the attachment bolts have insulation
washers installed. Then tighten the bolts.
Use an ohmmeter to check that the attachment bolts are not electrically
connected to the base frame, and that no electrical conductivity exists between
the base frame and the floor.
The total leak resistance of all floor rails to the main grounding busbar must be
greater than 100k.

4.5

Check the pre-assemble components and


cablings.
INSTALLATION PHASE

COMPLETED

Other documents relevant for this task are Installing ATCA hardware and
external cabling plan.
Check that the pre-assembled components are properly attached. The delivery
includes the following pre-assembles components:

Shelf

Power distribution units (PDUs), 2 pcs per shelf

Check that the pre-assembled internal grounding cables are properly attached.
They are connected from the shelves and from the PDUs to the cabinet
grounding rail.
Check that the internal power cables between PDUs and PEMs are properly
connected.
Check that all other pre-assembled internal cabling is properly connected.

4.6

Connect the Grounding


INSTALLATION PHASE

COMPLETED

Connect the cabinet to the site ground.


Connect the grounding cables to the cabinet using a appropriate routing
Connect the grounding cables to each shelves
If required, use NEBS or DC/C compliant grounding
If you need to use optional DC/C complaint grounding, install the grounding
bracket to each PDU. Tighten the nuts, which are holding the grounding
bracket to 5.1Nm.

Version 1.0.2

Page 12 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

4.7

Connect the site power supply input cables to


the PDUs
INSTALLATION PHASE

SDR &
INITIALS

Prepare the cables and connectors. Use 45 degree angle cable lugs
Connect the power supply cables (+UB and UB) to the PDU power supply
terminals and secure with the washers and nuts. Tighten the nuts to 5.1Nm.
Fasten the PDU covers in place

4.8

Test the Power supply


INSTALLATION PHASE

COMPLETED

Ensure that the polarities of the supply lines are correct and main fuse size
Main fuse:

Switch on the site main power supply to the PDUs


Measure the input voltages to the PDUs
Measured voltage:

VDC

Switch on the circuit breakers of the PDUs


As a result, verify that:
All LEDs on the shelf alarm display, the fans and the PEMs are switched on.
Then the red out of service LEDs and hot swap LEDs will turn off.
Fans briefly spin at full speed and then the fan speed reduces to normal.
Switch off the main power supply and the circuit breakers of the PDUs before
installing the blades and other units.

4.9

Install blades and RTMs according to the


network element configuration
INSTALLATION PHASE

COMPLETED

Wear and ESD wristband


Check the network element configuration and slot position sticker on package
to identify the positioning of blades
Identify the individual blades and RTMs by checking the labels.

Version 1.0.2

Page 13 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

INSTALLATION PHASE

COMPLETED

Switch off the main power supply and the circuit breakers of the PDUs before
installing the blades and other units.
Install the two AHUB3-A Hub Blades to slot 8 and 9 in the shelf.
Install the ACPI4-A CPU Blades and CPRT4-A and CPRT4-B RTMs according to
the configuration. Check that they have been installed firmly, and see that
they have been pushed all the way in and there are no misalignments.
Check that the blade and RTM handles are turned inwards and all screws have
been tightened.
Install a filler unit to every blade and RTM slot or AMC bays that do not contain
a module in the configuration. Most of the filler units are pre-installed at the
factory

4.10 Install the rear cable tray


INSTALLATION PHASE

COMPLETED

Slide the cable tray on its support on the shelf


Secure the tray by using one M4 and one M3 screws on each side of the cable
tray

4.11 Connect the internal cables


INSTALLATION PHASE

COMPLETED

Connect the other internal cables on the rear side of the cabinet
Connect the internal cables on the front side of the cabinet
Place all excess cable length in the cable storage shelves and cable trays, tie
the cables to bundles with cable ties and attach them to the front and rear
trays and to the walls of the cabinet

4.12 Mount the cabinet door


INSTALLATION PHASE

COMPLETED

Determine the doors opening direction and, if necessary, change their


handedness
Verify door installation by opening and closing the doors a few times

Version 1.0.2

Page 14 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

4.13 Complete the installation


INSTALLATION PHASE

COMPLETED

Remove all temporary markings.


Verify against the checklist in this document that you have completed all the
necessary steps for the installation
Check the corrections in drawings used during the installation.
Close the cabinet doors and inspect the installation visually
Clean the installation site and recycle all waste materials
Fill in the Certificate of Completion.

Version 1.0.2

Page 15 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Notes on Installation

Version 1.0.2

Page 16 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

4.14 Installation Certificate of Completion


Almadar
Name:

Site Address:

Contract
Number:
Delivery
Number:
Site Name:
Site Number:

INSTALLATION STAGE

CHECKED
(INITIALS)

COMMENTS

Prepare for installation.


Prepare the equipment room.
Unpack and inspect the equipment.
Install the cabinet on earthquake base frame
Assemble the cabinet.
Connect the grounding.
Install the chassis into the cabinet.
Equip the chassis with blades (FRUs).
Connect the power supply.
Connect internal cablings
Connect external cablings
Install the doors in the cabinet (optional).
Complete the installation.
Nokia Siemens Networks hereby states that the whole of supplies detailed above have been inspected, tested and unless
otherwise stated conform to the specified requirements in the contract or order identified above.
Nokia Siemens Networks Site
Representative (print name):
Nokia Siemens Networks Site
Representative (signature):

Date:

Almadar Representative (print name):


Almadar Site Representative (signature):

Version 1.0.2

Date:

Page 17 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

This page left intentionally blank.

Version 1.0.2

Page 18 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

COMMISSIONING CHECKLIST
The Commissioning Engineer is to carry out all commissioning tests in accordance with
the Flexi NS Commissioning Procedure, using the Flexi NS User Manual and other
approved reference material. Almadar-Specific Parameters are to be used where
applicable. A signed Certificate of Completion for the Commissioning work must be
included in Section 5.13 of the Site Folder, certifying that the Installation work has
been completed to the required standard. The Commissioning Engineer is responsible
for:

5.1

Checking the quality of the Commissioning

Correcting any Commissioning problems/faults or deficiencies

Familiarization with current Technical Notes

Commissioning the Flexi NS system in preparation for Integration

Completing this checklist, including signature and date

Completing the necessary Site Deficiency Reports

Completing the necessary Fault Reports

Informing the Site Manager of work progress, including any problems as they
arise

Completing the Certificate of Completion and placing it in Section 5.13 of the


Site Folder

Commissioning Preparations
COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Check the Installation Certificate of Completion and Site Deficiency Reports.


Clear out correction requirements for the commissioning starting.
Check the availability of tools and measurement devices required for
Commissioning. Acquire missing tools and measurement devices.
Check the availability of the site-specific documents (incl. IP plan). Acquire
missing ones.
Equipment needed for the initial inspections and testing
1. Antistatic equipment
2. Computer with
3. Paper clip (for pressing restart button)
4. USB memory stick

Version 1.0.2

Page 19 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Related documents

Flexi NS Commissioning Checklist

Equipping and Cabling Flexi NS

ATCA Shelf User Guide for Flexi NS

ACPI2-A and ARTM2-A User Guide for Flexi NS

Hub Blade User Guide for Flexi NS

AdvancedMC User Guide for Flexi NS

MML Command Reference Manuals

Maintaining and Troubleshooting Flexi NS Hardware

5.2

Checking the settings and the configuration


COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Check visually that all the LEDs are correctly lit


Unit

Checked

Unit

ACPI2-A

HDSAM-A

AHUB2-A

PEM

ARTM2-A

PDU

ASMGR-A

SHALD-A

Checked

ETHAM-A
Check the functionality of the Intelligent Platform Management Controller
(IPMI) shelf manager(s)
Log on to the shelf manager
User name

Default password

root

shmm_root

admin

shmm_admin

monitor

shmm_monitor

Change the root password, # passwd


Check the minimum default fan speed in the shelf, clia getfanlevel
Check from the printout that the Hot Swap State in every unit is M4 (Active),
clia board

Version 1.0.2

Page 20 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Check the shelf address:


a. Read the existing shelf addresses, clia shelfaddress
b. In case needed, change the shelf addresses with the
command clia shelfaddress
c.

Check the configuration with the MML command WTI

Clear the System Event Log, clia sel clear


Check the CPU blade BIOS settings using the BIOS setup tool
Unit

Checked

1. ACPI2-A BIOS settings


2. OMU-specific BIOS settings
3. Boot order
4. OMU units
5. BIOS settings for other functional units
6. Boot menu in other units
Check if the service terminal interface of AHUB2-A works and run AHUB selftest
Check the AHUB2-A configuration used for EMB (BI serial port), show
interface

5.3

Inspecting the storage devices


COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Log on to the OMUs and MCHUs one by one and execute Steps 2 and 3 to each
unit.
Check if the disk can be read
00-MAN> ZMQ:W0
00-MAN> ZMQ:W1
Check that the disk units are initialized
00-MAN>ZMX:W0
00-MAN>ZMX:W1
Unit
OMU-0

Version 1.0.2

Checked

Unit

Checked

MCHU-0

Page 21 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

OMU-1

5.4

MCHU-1

Creating a bootable USB stick and copying a


minidebugger to it
COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Connect the USB memory stick to the USB port in the front panel of the active
OMU.
Check its working state with the MML command ZISI.
Create a bootable USB media with minidebugger
File system

Checked

1. FAT16 filesystem
2. FAT32 filesystem
Updating minidebugger build and copying it to USB memory stick.

5.5

Open MML session


COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Configure the IP address with OMU serial port and VIMMLA


Open MML session via TELNET
Create system name
Configure the service terminal for alarms (optional)
Check the start-up
The start-up order of the whole system is as follows:

Version 1.0.2

Page 22 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

COMMISSIONING PHASE & RELATED DOCUMENTS


Unit

COMPLETED
Checked

1. OMU
2. MCHU
3. SMMU
4. CPPU
Monitor the start-up of the units
Check Ethernet Message Bus (EMB) connections
Flexi NS

EMB address

OMU-0

0000

OMU-1

0001

CPPU-0
CPPU-1
MCHU-0

Checked

0042
0043
0004
0005

MCHU-1

0010

SMMU-0

0011

SMMU-1
Check states of the LAN ports in the ACPI2-A blades (QHQ).
Check states of the computer units (USI).
Check that there are no LAN-related alarms active (AHO).
Check that the data in the computer units MAC address table is correct.
00:ZEBS>A:0x000:0xFFFF
Check from the print-out
1. All computer units have been listed.
2. There are two MAC addresses for each computer.
3. Both EMB0 and EMB1 are OK for all units and no units are
listed at the end of the execution print-out.
Check the error logs
42:ZEBS>L
00:ZEBS>LI;

Version 1.0.2

Page 23 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

5.6

Inspect Flexi NS software versions


COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Check software package (ZWQO::;)


Check the versions of the running/default software package (processes, files)
(WQB).
Default SW package: ______________
Package ID:

______________

Change Note ID:

______________

Check BIOS versions (ZWDB).


Bios version:

______________

Check IPMI versions (ZWDD).


IPMI version:
Blade Unit

5.7

______________
SW Version

Blade Unit

SW Version

Inspect I/O devices


COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Check I/O devices (ZISI)


Check the states of the I/O ports after every change (ZISI)
Check if the corresponding I/O device functions by changing the disk state
(ZISC)

Version 1.0.2

Page 24 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

COMMISSIONING PHASE & RELATED DOCUMENTS


Unit

COMPLETED
Checked

WDU
VTP
VPP
UPP
VDS

5.8

Inspect maintenance system

Console connection, ATCA Shelf User Guide for Flexi NS


COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Check hardware alarms.


1. Switch off one of the ADPDU-As
2. Check alarms (ZAHO). PDU alarm should appear.
3. Switch on ADPDU-A. PDU alarm is cancelled.
Complete power break test according to the Commissioning Flexi NS
instructions.
1. Check that units are in appropriate state (ZUSI).
2. Complete power break to the system.
3. Check that system recovers from power break.

5.9

Check the hardware configuration


COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Print hardware configuration (ZWTI).

Version 1.0.2

Page 25 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Check the LAN device configuration.


1. Check the LAN unit states (ZUSI).
ZUSI:SWU;
ZUSI:EMB;
ZUSI:CNW;
2. Check the internal LAN configuration (ZWYI).
3. Check the switch activation status (ZW6E).
4. Check the SWU supervision status (ZYFF).
Check that the IP address is configured, trap host is configured and
supervision status is reachable for every SWU.
Check LAN (Ethernet) switches
1. Check the software versions of the Ethernet switch.
2. Check if the Ethernet switches have been assigned passwords.
3. Check if the Ethernet switch identification (label information) is correct.
4. Check if each Ethernet switch has been assigned a correct Ipaddress or
that DHCP is enabled.
5. Check if the Telnet server is running.

5.10 Checking unit diagnostics and working states


Check if you have the following equipment and the documents; PC for connecting Alarm printer,
MML dialog and service terminal connections, Alarm Reference Documentation, and Printouts of
Starting Phases.
COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Connect the alarm printer and MML terminal to the OMU


Check the state of the units (ZUSI)
If the state of the units is WO-EX, change it first to SP-EX and then to TE-EX.
If the state is SP-EX, change it directly to TE-EX (ZUSC).
Run the diagnostics on the units (ZUDU)
Change the unit state back to the original SP or WO (ZUSC)
Test all the units and record the results.

Version 1.0.2

Page 26 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

COMMISSIONING PHASE & RELATED DOCUMENTS


Unit

Checked

Unit

OMU-0

SMMU-0

OMU-1

SMMU-1

CPPU-0

SMMU-2

CPPU-1

MCHU-0

CPPU-2

MCHU-1

CPPU-3

IPDU-0

CPPU-4

IPDU-1

COMPLETED

Checked

5.11 Copying additional software


COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Check that the general Change Deliveries (CD) are installed.


Install the CDs that have not been installed.
Change Notes / Sets
____________ ____________
____________ ____________
____________ ____________
____________ ____________
____________ ____________
Check the CD level of the software build (ZWNH).
After CD installation is completed, restart the whole system (ZUSS).

5.12 Finishing Commissioning

COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Record the item codes and serial numbers of the network element.

Version 1.0.2

Page 27 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

COMMISSIONING PHASE & RELATED DOCUMENTS

COMPLETED

Fill in the Commissioning Certificate of Completion.

Version 1.0.2

Page 28 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Notes on Commissioning

Version 1.0.2

Page 29 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

5.13 Commissioning Certificate of Completion


Almadar
Name:

Site Address:

Contract
Number:
Delivery
Number:
Site Name:
Site Number:

COMMISSIONING STAGE

CHECKED
(INITIALS)

COMMENTS

Commissioning Preparations
Checking the settings and the configuration
Inspecting the storage devices
Creating a bootable USB stick and copying a minidebugger to it
Open MML session
Inspect Flexi NS software versions
Inspect I/O devices
Inspect maintenance system
Check the hardware configuration
Checking unit diagnostics and working states
Copying additional software
Finishing Commissioning
Commissioning Certificate of Completion
Nokia Siemens Networks hereby states that the whole of supplies detailed above have been inspected, tested and unless
otherwise stated conform to the specified requirements in the contract or order identified above.
Nokia Siemens Networks Site
Representative (print name):
Nokia Siemens Networks Site
Representative (signature):

Date:

Almadar Representative (print name):


Almadar Site Representative (signature):

Version 1.0.2

Date:

Page 30 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

This page left intentionally blank.

Version 1.0.2

Page 31 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Integration Checklist

6.1

Integration Checks
The Flexi NS Integration Engineer is to carry out all integration and tests in accordance
with the Flexi NS User Manual and other approved Integration Procedures. The
Integration Engineer is responsible for:

Version 1.0.2

Checking that Site Folder documentation is complete.

Implementing datafill and completing checklist.

Reporting outstanding tasks.

Completing the necessary Fault Reports.

Informing the Project Manager of work progress, including any problems as


they arise.

Verifying that Flexi system has been integrated and is ready for System
Acceptance Test.

Completing the Certificate of Completion and placing it in Section 6.11 of the


Flexi NS Site Folder.

Completing the Site Acceptance Certificate and placing it in Section 7 of the


Flexi NS Site Folder.

Page 32 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

6.2

Prerequisites for integration


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Check Commissioning Certificate of Completion and outstanding reports. Clear


out correction requirements for the integration starting.
Check the availability of the documents needed. Acquire missing ones.
Related Documents

Flexi NS Integration Checklist

Interface descriptions

S6a interface description

S1 interface description

NAS interface description

S11 interface description


MML Command Reference Manuals

Flexi NS User Guide

Checked

Network integration data (datafil) available from planning.

6.3

Create IP connectivity

6.3.1

Creating IP configuration for MCHU


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Create network interface (ZQRA)


Configure IP address (ZQRN)
Create static routes (ZQKC)

6.3.2

Creating IP configuration for SMMU


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Create network interface for SMMU (ZQRA)


Configure IP address (ZQRN)
Create static route (ZQKC)

Version 1.0.2

Page 33 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

6.3.3

Creating IP configuration for CPPU


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Create network interface for CPPU (ZQRA)


Configure IP address (ZQRN)
This step must comply with site solution, for L2 redundancy, S1 and S11 traffic
should use the same Ethernet connection, otherwise 2+2 connections are
needed.
Create static route (ZQKC)

6.4

Set network-specific numbers


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Create mobile country code (ZWVS)


Create mobile network code (ZWVS)

6.5

Create network element interfaces


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Create the S1-MME/S1-AP interface (MME eNB) (ZKAC)


Create the S11/GTPv2 interface (MME - S-GW) (ZKAC)
Create the S6a interface (MME HSS) (ZKAC)
Restart WO MCHU (ZUSU)

6.6

Configure S6a interface


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Enable the S6a interface against HSS.

Version 1.0.2

Page 34 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

INTEGRATION PHASE & RELATED DOCUMENTS


Connection activity

COMPLETED
Checked

Set the origin host


Set the origin realm
Set the destination host
Set the destination realm
Set the destination IP-address and port
Start remote session to SMMU (DDS).

6.7

Configure S1 and S11 interfaces


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Start remote session (ZDDS)


Copy the ini files to your local PC and check and modify the following
parameters.
File/parameter

Checked

S1HANDLER.INI

sctp_server_port = 49152

MMETRH.INI

GWLocalPort =2123

GWIPAddressRemote=10.102.182.184

GWRemotePort=2123

PGWIPAddressRemote=10.102.182.184

After modifying the settings, copy the files back to the packet directory.
Restart MCHU to activate the new parameters (ZUSU).

6.8

Create PLMN
INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Create home PLMN (ZMXA)

Version 1.0.2

Page 35 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Add destination realm (ZMXN)

6.9

Create IMSI analysis


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Create IMSI analysis (ZCBC)

6.10 Synchronizing in Flexi NS


INTEGRATION PHASE & RELATED DOCUMENTS

COMPLETED

Check Flexi NS time synchronization

Version 1.0.2

Page 36 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Notes on Integration

Version 1.0.2

Page 37 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

6.11 Integration Certificate of Completion


Almadar
Name:

Site Address:

Contract
Number:
Delivery
Number:
Site Name:
Site Number:

INTEGRATION STAGE

CHECKED
(INITIALS)

COMMENTS

Integration Checks
Prerequisites for integration
Create IP connectivity
Creating IP configuration for MCHU
Creating IP configuration for SMMU
Creating IP configuration for CPPU
Set network-specific numbers
Create network element interfaces
Configure S6a interface
Configure S1 and S11 interfaces
Create PLMN
Create IMSI analysis
Synchronizing in Flexi NS
Nokia Siemens Networks hereby states that the whole of supplies detailed above have been inspected, tested and unless
otherwise stated conform to the specified requirements in the contract or order identified above.
Nokia Siemens Networks Site
Representative (print name):
Nokia Siemens Networks Site
Representative (signature):

Date:

Almadar Representative (print name):


Almadar Site Representative (signature):

Version 1.0.2

Date:

Page 38 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

This page left intentionally blank.

Version 1.0.2

Page 39 of 40

Flexi NS - Site Folder


SITE NAME / SITE NUMBER

Site Acceptance Certificate


INSTRUCTIONS: A Nokia Siemens Networks Representative and Almadar
Representative complete this form upon acceptance of each site. File the completed
form in the appropriate Site Folder.

Almadar Name:

Date:

Site Location/Number:
Project Description:
Nokia Siemens Networks P. O. Number(s):
Almadar P. O. Number(s):
The above referenced site project (i) has passed all applicable Acceptance Tests, (ii) has been installed
properly, subject to resolution of outstanding SDR items, and (iii) is ready to be placed in service.
Any discrepancies are specified on the following SDR or attachment (s).

Installation SDR Dated:

No
Discrepancies

Quantity of SDR Items:

Not Applicable

Site Test Data Forms


Dated:

No
Discrepancies

Quantity of SDR Items:

Not Applicable

Almadar Representative

Nokia Siemens Networks Representative

Signature:

Signature:

Printed
Name:

Printed
Name:

Title:

Title:

Date:

Date:

Distribution:

Version 1.0.2

Almadar

Accounting

Project Manager

Page 40 of 40