Professional Documents
Culture Documents
Specification For Glazed Fire-Clay Sanitary Appliances
Specification For Glazed Fire-Clay Sanitary Appliances
Indian Standard
SPECIFICATION FOR
GLAZED FIRE-CLAY SANITARY APPLIANCES
PART
SPECIFIC REQUIREMENTS
OF KITCHEN
AND LABORATORY
SINKS
( Third Revision)
Sanitary
Appliances
and Water
Fittings
Sectional
Committee,
BDC 3
Reprcsrnlin6
Chairman
Municipal
Corporation
Bombay
Srrnr K. D. MUL~KAR
of
Greater
Bombay,
Membera
&
Environmental
Central
Public
Health
Engineering Organization ( Ministry of Works
& Housing ), New Delhi
DEPUTY ADVISER ( PHE ) ( Altcrnatr )
M/s Goverdhan Das P. A. ( Calcutta ), Calcutta
SHRI J. R. Aoonawax.
National Test House, Calcutta
SERI S. K. BANERJEE
SHRI D. K. KANUN~O ( Al&mate )
Central Glass & Ceramic
Research
Institute
SERI M. K. BASU
(CSIR ), Calcutta
Uttar Pradesh Jal Nigam, Lucknow
CHIEF EN~INEEB
SUPEBINTENDINGENGINEER ( Alter;;;;c)
Department,
Health
Engineering
CHIEF ENGINEER
Trivandrum
SHRI K. RAMACHANDRAN (Alternate )
Delhi Municipal Corporation, Delhi
&IRI .T. DCRUZ
S&x s. A. SWAMY ( Alternate )
Engineer-in-Chiefs
Branch, Army Headquarters,
SHRI B. R. N. GUPTA
New Delhi
SHRI K. V. KRISHNAMURTHY ( Alternate )
Municipal
Corporation
of Greater
Bombay,
HYDRAULIO ENGINEER
Bombay
DEPUTY HYDRAULIO ENGINEER ( Allernate )
ADVISEB
( Continuedon page 2 )
INDIAN
Q C@yri&
STANDARDS
1986
INSTITUTION
This publication
is protected under the Indian Copyright Act ( XIV of 1957) and
reproduction in whole or in part by any means except with written permission of the
publisher shall be deemed to be an infringement of copyright under the said Act.
page 1 )
Membrrs
Repr#renting
SHRI S. R. KSHIH~AGAH
National
Environmental
Engineering Research
Institute (. CSIR II
1. Naeour
A
&RI A. W. DESEPANDE ( Allnaate )
SHRI K. LAXBHMINARAYANAN
Hindustan Shipyard Ltd, Vishakhapatnam
SERI A. SHAKIFF ( Alternate )
National Buildings Organization, New Delhi
DR A. V. R. RAO
SHRI.J. SENOUPTA ( Alt~matr )
E.I.D. Parry ( India ) Limited, Madras
Sunr A. K. SARKAK
SHRI M. DO~AISWAMY ( Alternate )
Leader Engineering Works, .Jalandhar
SHRI D. K. SEH~AL
SHRI B. B. SIRKA ( Altcrnatc )
Mini;styhiof
Railways
(
Railway
Board ), New
SENIOR CIVIL ENQXNEEH ( WATER
SUPPLY )
Cent;raoryeEding
Research
Institute ( CSIR ),
SH~I S. K. SHARMA
Maharashtra Water Supply & Sewerage Board,
New Bombav
Hindustan Sanitiryware
& Industries Limited,
Bahadurgarh ( Haryana )
Central Public Works Department, New Delhi
SHRI M. N. SHEWADE
SHRI R. K. SOMANY
SUPERINTENDING SURVEYOB OF
WORKS ( ND2 3
SURVEYOK OF WORKS I ( NDZ ) ( Altcrnats )
Directorate Grneral of Technical Development,
SHRI R. THANJAN
NFW Delhi
SHRI M. M. ALIKHAN (Alternate \
Directorate Grncral of Supplier & Disposals, New
SHRI T. N. UBOVEJA
Delhi
Director General, ISI ( ,%&$cia M.mbcr )
SRRI G. RAMAN,
.Director ( Civ Engg ).
Secretary
SHRI K. K. SHARMA
Joint Director ( Civ Engg ), IS1
SELRIB. R. N. GUPTA
Branch, Army
BDC 3 : 1
Headquarters,
Members
&tar V. ANANTHANARAYAIAN
SHRI M. K. BASV
CHIEF ENCXNEEX
CHIEF EN~INEEB ( S~WESAOE )
DBPUTY
CHIEF
( SEWE~AUE ) (
EN~~EBR
of
Research
Institute
& Drainage
Greater
Board,
Bombay,
A~tcrnata
)
( Cmtinucd en psga 8 )
IS:771
(Part2)-1985
Indian Standard
SPECIFICATION FQR
GLAZED FIRE-CLAY SANITARY APPLIANCES
PART 2 SPECIFIC REQUIREMENTS OF KITCHEN
AND LABORATORY SINKS
( Third Revision )
0. FOREWORD
0.1 This Indian Standard ( Part 2 ) ( Third Revision ) was adopted by
the Indian Standards Institution on 31 July 1985, after the draft finalized
by the Sanitary Appliances and Water Fittings Sectional Committee had
been approved by the Civil Engineering Division Council.
0.2 This standard was first published in 1958 and subsequently revised in
1963 and 1979. The third revision of this standard has been taken up to
incorporate further modifications necessary in the light of the comments
received.
The modifications include additional clauses on thickness of
sinks and requirements of rim and base portion of the appliances.
The
requirements
applicable
to all appliances
and specific
general
requirements for different types of appliances have been covered in
This standard ( Part 2 ) lays down the
separate parts of the standard.
specific requirements of glazed fire-clay kitchen and laboratory sinks.
0.3 In the formulation of this standard due weightage has been given to
international coordination among the standards and, practices prevailing
in different countries in addition to relating it to the practices in the field
in this country.
0.4 For the purpose of deciding whether a particular requirement of this
standard is complied with, the final value, observed or calculated,
expressing the result of a test or analysis, shall be rounded off in
accordance with IS : 2-l 960*.
The number of significant places retained
in the rounded off value should be the same as that of the specified value
in this standard.
1. SCOPE
1.1 This standard ( Part 2 ) lays down the pattern and sizes, construction,
dimensions and tolerances of kitchen and laboratory sinks made of
fire-clay.
*Rules
for rounding
off numerical
values
(m&d).
49 : 771 ( part
2 ) _ ~985
2. REQUIREMENTS
2.1 General - The general
requirements
for material,
manufacture,
methods of test, and inspection shall conform to IS : 771 ( Part 1 )-1979*.
2.2 P&ttewms, f&es ad
H&ding
Capacities
- Sinks shall be suitable
Jar kitchen or laboratory
( see Fig. 1 ) and shall be made in the following
sizes and hofding capacities:
Pattern
a) Kitchen
Lsizcs
mm
sinks
b) Laboratory
sinks
+------A
IF
Holding Capacities
( Litres ), Min
r---h
___~
Without
Ovsrllow
With
Overflow
51
42
32
42
36
26
con
500
450
400
30
16.5
12.5
9
25
14
11
8
x
x
x
x
400
350
300
250
x
x
x
x
200
150
150
150
,=qTRIM
FIG. 1
PROJECl,tON (OPTIONAL)
( secondrroision ) .
SINKS
Part 1 General
requirements
IS : 771 ( Part
2.2.1 The dimensions mentioned
portions of the appliance.
2) - 1985
to the rim
2.2.2 The kitchen and laboratory sinks may be made in other patterns
and sizes where so agreed to between the manufacturer
and the
purchaser.
However, tolerances on dimensions shall be as specified in
this standard.
2.3 Construction
2.3.1 Kitchen Sinks - The
kitchen
sinks
construction with or without rim and with or
The slot type overflow shall have a minimum
be SO designed as to facilitate cleaning of the
overflow, where provided, shall be minimum
shall be of one
piece
without combined overflow.
area of 1 100 mm2 and shall
overflow. The invert of the
30 mm below the top edge.
23.1.1 The sinks shall have a circular waste hole into which the
interior of the sinks shall drain.
The waste hole shall be rebated or
beveiled internally (see Fig. 2 ) with an overall diameter of 90 mm and a
depth of 10 mm to suit a waste fitting having a flange of 88 mm
diameter.
BEVELLED
WASTEHOLE
FIG. 2
and Tolerances
DIMENSIONS
OF KITCHEN
AND
LABORATORY
to
SINKS
in millimetres.
(8)
(9)
(10)
30
75
90 + 3
-0
65 + 3
-0
150
30
75
90 + 3
-0
65 + 3
-0
200
150
30
75
90 + 3
-0
65 + 3
-0
400
200
90
30
75
65 + 3
-0
45 + 3
-0
500
350
150
go
30
75
65 + 3
-0
45 + 3
-0
450
300
150
90
30
75
65 + 3
-0
45 + 3
-0
400~250~150
400
250
150
90
30
75
65+3
-0
45+3
-0
SIZE
DEF
(2)
(3)
(4)
(5)
(6)
(7)
750
450
250
150
600
450
250
500
400
600
PATTERN
(1)
a) Kitchen sinks
b) Laboratory
sinks
Min Min
a) On dimensions
b) On dimensions
less than
on the
and
50 mm f 2 mm.
the
IS : 771 ( Part
2 ) - 1985
3. MARKING
3.1 Sinks shall be clearly and indelibly marked at a prominent
visible after the sinks are installed, with the name or trade-mark
manufacturer.
place,
of the
this
NOTE- The use of the IS1 Certification Mark is governed by the provisions of
the Indian Standards Institution
(Certification
Marks ) Act and the Rules and
Regulations made thereunder.
The IS1 Mark on products covered by an Indian
Standard conveys the assurance that they have been produced to comply with the
requirements of that standard under a well-defined system of inspection, testing and
quality control which is devised and supervised by IS1 and operated by the producer.
IS1 marked products are also continuously checked by IS1 for conformity to that
standard as a further safeguard.
Details of conditions under which a licence for .thc
use of the IS1 Certification Mark may be granted to manufacturersor
processors,
may be obtained from the Indian Standards Institution.
4. SAMPLING
4.1 The sampling shall be done in accordance
*Method
of sampling ofvltrcous
with IS : 914X)-1985*.
(Jirsf reaision).
Repenting
Hindustan
Sanitaryware
&
Industries
Ltd,
Bahadurgarh ( Haryana )
Central Public Works Department, New Delhi
SQPERINTENDINQ SURVEYOR OF
WORKS ( SWZ )
SURVEYOR OF WORKS ( NDZ ) ( Alternate )
FGP Ltd, New Delhi
SEBI G. K. TAXIER
Soar S. M. DASTUR ( Afteraafe )
Directorate
General
Soar T. N. UBOVEJA
New Delhi
of
Supplies
& Disposals,
( Pqe4,
i)
clause 2.2 ):
ii) Substitute 9.5 for 42, 36, 26 against Kitchen sinks in the last
COlUltUL
f
RIM PROJECT10
FIG. 1 KITCHENANDLABO~~RY
Srms
Delete.
2.33 Waste Hole L The sir& shall have a circular waste hole ( see Fig. 2 )
through which liquid content of the sink shall drain. The base of the sink shall
have proper and sufficient slope to drain the liquid content into the waste hole.
The waste hole shall be bevelled internally and shall meet the dimensions given
in? able 1.
FIG. 2 DETAILS
OF WASTE HOLFS FOR
KITCHEN
AND
TABLE
SL No.
DIMENSIONS
OF WASTE
REFMFYGURE
PARTICULARS
LABORATORY
HOLE
DIMENSIONSw MM
d,
46, +2/-3
ii)
d4
65~2
ds
15 Max
bmdkdportion of opening
iv)
da
60Min
v)
Depth
45 Min
50 Ma%
vi)
bt
SINKS
4OMin
4s Max
to the
of
the
the
the
(CED3)
Reprography
Unit, BIS, New Delhi. India
AMENUMENT
SPECIFIC
REQUIREMENTS
LABORATORY
OF KITCHEN
AND
SINKS
( Third Revision)
(CED3)
Reprography IJnit, HIS, New Delhi, India
AMENDMENT
NO. 3 DECEMBER
1998
TO
FOR GLAZED
IS 771( Part 2) : 1985 SPECIFICATION
FIRE-CLAY SANITARY APPLIANCES
PART
[ Page 4, clause 2.2 ( see also Amendments No. 1 and 2 ) ] Holding Capacities
Delete
[ Page 6, Table 1 ( see aho Amenuhent No. 1 ) ] (vi) along with their contents.
( Page 2, Fig. 2, Amendmenr No. 1) -
Delete angle
Substitute
a waste
fitting,
tbe following
having
for
a flange
(CED3)