Professional Documents
Culture Documents
Kiekens Dustmaster: Type Cartridge Filter
Kiekens Dustmaster: Type Cartridge Filter
Kiekens Dustmaster: Type Cartridge Filter
KIEKENS
DUSTMASTER
DM6000 / DM7000
filter unit
6KVE280 2.2kW
6KVE280 3kW
curve
8KTE280 4kW
curve
DM6000
6KVE315 3kW
6KVE315 4kW
12KVE315 5.5kW
8KTE315 7.5kW
pos. 4
pos. 3
pos. 2
pos. 1
12KSE315 11kW
8FVE400 7.5kW
12KRE315 11kW
12FTE400 11kW
4 x 13 = 52 m2
3 x 13 = 39 m2
5 x 13 = 65 m2
filter
4 x 13 = 52 m2
filter
6 x 13 = 78 m2
area
2 x 20 = 40 m2
area
4 x 20 = 80 m2
DM6000
3 x 20 = 60 m2
DM7000
5 x 20 = 100 m2
6 x 20 = 120 m2
filter
quality
4
5
example code DM
HEPA filter.
8KSE315 7.5kW
2 x 13 = 26 m2
4 x 20 = 80 m2
Options:
0,75
1,25
2,25
2,50
2,75
500
4500
450
4000
400
3500
350
3000
2500
2000
300
250
200
150
1500
3,25
1000
100
50
500
2
1.000
5
6
2.000
3.000
4.000
5.000
6.000
V [m3/h]
7.000
8.000
9.000
10.000
11.000 12.000
Operation:
The dust laden air flows through the inlet in the preseparator room 2 . The relatively heavy dust is separated
there immediately and falls into the dust container 6 (DM6000: 55 l and DM7000: 70 l). The rest of the dust in
the polluted air is being filtrated on the exterior of the filter cartridges and falls into the dust container as well 6 .
The clean air flows through the pores of the filtermaterial to the clean air room. The air will in principle be
carried back into the work area but can also be blown into the atmosphere. Without any interruption of the
activity 1 filter cartridge is recurrently being cleaned by means of compressed air. Because of the compressed
air a cartridge is being cut off with a valve in order for the spindle to come in rotation. Because of this the filter
material is being blown through fold by fold by means of blow pipes 3 and the dust layer built up on the
filtermaterial falls through the cone 5 in the dustbin. The construction is designed in such a modular way that
the inlet 2 , the inspection panel 4 , the fan housing 1 and the dustbin 6 can be constructed in different
ways towards each other.
ISO 9001
Accredited by the
Dutch Council for
Accreditation
1045932 No legal rights can be derived from this publication. Specifications may be changed without prior notice. 08-2003.
0,50
5000
P tot [Pa]
0,25
V [m3/s]
1,50 1,75