Professional Documents
Culture Documents
DT-500 80 80a Im 96M12877 GB WW 1123-1
DT-500 80 80a Im 96M12877 GB WW 1123-1
DT-500/80/80A
The DT-80A complies with the RoHS Directive.
Instruction Manual
Before you start using this unit, read this Instruction Manual.
After you have finished reading this manual, store the manual in a safe place so that it can
be retrieved whenever necessary.
Preface
This manual describes how to install and set the Data Storage Terminal DT-500/80/80A hardware.
Before you start to use the Data Storage Terminal DT-500/80/80A, be sure to thoroughly read this
manual so that you can make full use of DT-500/80/80A's performance and functions. Also, store
this document in a safe place so that you can retrieve it whenever necessary.
Symbols
This manual uses the following symbols to alert the user to items that must be observed to
prevent hazards to the user or damage to equipment.
DANGER
Failure to follow these instructions may lead to death or serious injury.
WARNING
Failure to follow these instructions may lead to injury.
CAUTION
Failure to follow these instructions may lead to physical damage (product
malfunction, etc.).
Important
Note
Request
(1) No part of this instruction may be reprinted or reproduced without the prior written permission
of KEYENCE CORPORATION.
(2) The contents of this manual are subject to change without notice.
(3) Every effort has been made in preparing this document. If, however, you find any unclear
points, errors, omissions or other inconsistencies, please feel free to contact us.
(4) Note that KEYENCE CORPORATION shall not be liable for any influence resulting from
operation of this product regardless of item (3) above.
(5) We shall replace any missing or incorrectly collated pages.
Safety Precautions
General Precautions
At startup and during operation, be sure to monitor the functions and performance of the DT500/80/80A.
Provide a safety circuit that does not pass via the programmable controller to enable failsafe
operation of the entire system in the event that the programmable controller fails.
Output circuit or internal circuit malfunctions sometimes prevent control from being performed
normally. Be sure to provide a safety circuit in control systems where circuit malfunction may
lead to fire or other serious accidents.
Do not modify the DT-500/80/80A or use it in any way other than described in the specifications.
The functions and performance of products used or modified in this way cannot be assured.
Use this product in combination with other devices only after careful consideration, since the
DT-500/80/80A may fail to satisfy its functionality and performance capabilities as a result of the
conditions and environment in which it is used.
Do not use this product for the purpose to protect a human body or a part of human body.
This product is not intended for use as explosion-proof product. Do not use this product in
hazardous location and/or potentially explosive atmosphere.
This product uses GPL-compatible software.
Ethernet is a registered trademark of Xerox Corporation in the United States.
Other company names, product names, and model names used in this manual are trademarks
or registered trademarks of their respective companies.
TKK
Ferrite core
TFT 152613N
TFT 152613N
TFT 112514N
TFT 152613N
Number of turns
2
2
2
2
Cable
Power cable
I/O cable
OP-51507
OP-51507
Ferrite core
Number of turns
2
2
2
2
Power cable
OP-51507
OP-26484
OP-26484
DT-80
Port/connector
Power terminal
Ethernet port
PLC connection port
Serial port
TKK
TFT 102010N
TFT 152613N
TFT 102010N
TFT 102010N
Cable
DT-80A
Port/connector
Power terminal
Ethernet port*
PLC connection port
Serial port
Ferrite core
TKK
TKK
TDK
TDK
TKK
TFT 081813N
TFT 102010N
ZCAT 2017-0930
ZCAT 2017-0930
TFT 081813N
Number of turns
2
1
1
2
2
Cable
Power cable
OP-51507
OP-26484
OP-26484
* Use both of two ferrite cores for the cable connected to the Ethernet port.
Remarks:
These specifications do not give any guarantee that the end-product with this product
incorporated complies with the essential requirements of EMC Directive. The manufacturer of the
end-product is solely responsible for the compliance on the end-product itself according to EMC
Directive.
(4)Status LED
POWER
RUN
STOP
(1)RUN/STOP
selector switch
RUN
LINK
LINK
ACT
STORAGE
MEMORY CARD
ACT
LINK-DT
SHUT
DOWN
(5)USB port
(7)PoE switch
(6)Ethernet port 1 (Ethernet1)
Rear
Base
The Memory Card cannot be accessed with the Memory Card cover open.
Name
POWER
Description
Indicates the state of the power supply.
RUN
LINK1
ACT1
LINK2
ACT2
STORAGE
LINK-DT
CARD
CAUTION
The PoE function of this product does not support IEEE802.3af. Use it only
in Wireless LAN station NE-W11 made by Keyence Corporation.
Do not use the PoE function when connecting to a 1000 Base-T compatible
terminal. Doing so might damage the terminal you are connecting to.
Do not connect the PoE function of the DT-500 to Ethernet ports on other DT500s. Doing so might damage the other DT-500.
No.
Indication
IN0
SHUT
DOWN
Name
Description
24V
0V
0V input terminal
NC
Not connected
NC
Not connected
OUT0
OUT1
OUT2
COM(OUT)
IN0
IN1
SHUT DOWN
COM(IN)
(1) RUN/STOP
selector switch
RUN
PLC
LINK
ACT
LINK-DT
DATA STORAGE
TERMINAL
Rear
When the RUN/STOP selector switch is used to change the RUN mode to the
STOP mode, it sometimes takes time to move to the STOP mode as
communications between the master and the terminal must be processed.
Name
Description
RUN
PLC
LINK
ACT
LINK-DT
RUN
STOP
RUN
PLC
LINK
ACT
LINK-DT
NC
0V
No.
Indication
OUT
FG
NC
COM(OUT)
NC
Name
Description
24V
0V
0V input terminal
For connecting 0 V
NC
Not connected
Not connected
FG
FG terminal (earth)
OUT
Error/alarm output
terminal
COM(OUT)
NC
Not connected
Not connected
NC
Not connected
Not connected
Installation
Installation environment
Do not install the DT-500/80/80A in the following locations.
Locations subject to direct sunlight
Locations subject to surrounding air temperature out of 0 to +50C range
Locations subject to ambient humidity out of 35 to 85%RH range.
Locations subject to condensation caused by sudden temperature change
Locations subject to corrosive and flammable gasses
Locations subject to large amounts of dirt and dust, salt, iron and oil smoke
Locations directly subject to vibration and shock
Locations that may be splashed with water, oil or chemical mist
Locations where strong magnetic and electrical fields are generated
7
Installation orientation
DT-500
DT-80/80A
DT-500
30 mm or more
30 mm
or more
30 mm
or more
30 mm or more
DT-80/80A
30 mm or more
30 mm
or more
30 mm or more
30 mm or more
30 mm
or more
30 mm or more
Installation Method
Installing the DT-500/80/80A on a DIN rail
The following describes how to install the DT-500 on a DIN rail. The DT-80/80A is installed on a
DIN rail in the same way.
Push down the DIN rail mounting claw (lower) on the rear of the DT-500.
Push up the DIN rail mounting claw (lower) on the rear of the DT-500 to fasten the
DT-500 on the DIN rail.
click
Follow the installation procedure in reverse to remove the DT-500 from the DIN rail.
Cut out a mounting hole for screw fastening according to the following
dimensions on the DT-80/80A mounting surface.
163.6
44.5/M4
71.8
10
M4 screws
Note
The DT-80/80A can also be mounted on its left side using the side mounting
fixture. Note, however, that in this case the terminal blocks can no longer be
wired. When mounting the DT-80/80A on its left side, first check that wiring of
the terminal blocks is finished.
11
Inserting Battery
Inserting BATTERY1
BATTERY1 is used for backing up the calendar timer and the content of SRAM. Use OP-42139 for
BATTERY1.
Plug
Socket
Note
12
Inserting BATTERY2
BATTERY2 is for shutdown processing before turning the power OFF. Use DT-B4 for BATTERY2.
Whether or not DT-B4 is installed on the DT-500 differs according to how the DT-500 is turned OFF.
DT-500/80/80A Hardware Manual (Japanese version only available)
For details, refer to the
[1-4 Precautions Upon Use.]
The DT-500 is shipped without DT-B4 inserted. Buy DT-B4 separately as required.
Insert the batteries into the DT-500 body, and close the battery cover.
Tightening
torque
0.2 Nm
When the connector is connected, this product becomes a hazardous product (Class9) in
accordance with United Nations recommendations. For this reason, please consult beforehand with
your carrier regarding packaging for transportation before you transport this product by sea or by air.
Other device
A=B
Class D earthing
Other device
B
A
A>B
A<B
Terminal specifications
When wiring the Y terminal, use a terminal that matches the following dimensions.
B
d
Compatible dimensions
B: 6 mm or less
d: 3.2 mm or more
Y terminal dimensions
B: Distance across outsides of Y terminal
d: Distance between insides of Y terminal
(screw clamping section) width
Item
Wire gage
Tightening torque
Wire material
Wire type
Rated temperature
14
DT-500
AWG#20-16
0.51 Nm (4.5 lbfin)
Copper
Stranded wire
60C
DT-80/80A
AWG#22-14
0.79 Nm (7.0 lbfin)
Copper
Stranded wire
60C
DT-
500
24V
0V
24V
0V
NC
NC
OUT0
DT500
OUT1
OUT2
COM
(OUT)
IN1
COM
(IN)
IN0
SHUT
DOWN
Load
24V 0V
OUT
COM
FG (OUT)
30 VDC
100 mA
Power cable
15
Specifications
DT-500
General specifications
Item
Rated voltage
Current consumption
Noise resistance
Withstand voltage
Insulating resistance
Vibration resistance
Operating atmosphere
Operating surrounding air
temperature
Operating ambient humidity
Storage ambient
temperature
Storage ambient humidity
Applicable standard
Weight
16
Description
24 VDC 10%, Class 2
180 mA max.
1500 vp-p pulse width 50 n/1 sec (by noise simulator)
Compliant with IEC standard (IEC61000-4-2/3/4/5/6)
1500 VAC for 1 minute (across power terminal and case)
3000 Mmin. (500 VDC megger across power terminal and case)
Intermittent Vibration
Number of sweeps
Frequency
Acceleration Amplitude
0.075 mm
10 to 57 Hz
Compliant with JIS 57 to 150 Hz 9.8 m/s2
10 times in each of
B3502 IEC61131-2 Continuous Vibration
X-, Y- and Z-axes
(for 80 mins.)
Frequency
Acceleration Amplitude
10 to 57 Hz
0.035 mm
57 to 150 Hz 4.9 m/s2
Excessive amounts of dirt, dust and corrosive gases are not allowed.
0 to +50C (no icing allowed)
35 to 85%RH (no condensation allowed)
-20 to +70C (no icing allowed)
35 to 85%RH (no condensation allowed)
(EMI) EN61326-1, Class A
(EMS) EN61326-1
FCC Part15B, Class A
UL508
Approx. 470 g (with battery DT-B4 installed: 565 g)
Performance specifications
Item
Connectable terminal
Max. number of connected terminals
Description
DT80/80A/100/100A*
16 units
Approx. 512 Kbytes
SRAM size Backup: Primary lithium cell
Storage data
(BATTERY1,+25C, service life 5 years or more)
ROM size
Approx. 900 Mbytes (including work area)
Accuracy: 40 seconds/month (+25C)
Memory
Backup: Primary lithium cell
backup
Calendar timer
(BATTERY1,+25C, service life 5 years or more)
NTP compatible
Setup data
16Mbytes (100000 rewrites possible)
Memory Card
128M/256M/512M/1Gbytes compatible
Trigger common logging/trigger individual logging/serial No. logging/
Logging
lot No. logging/item common logging
Data
collection
Alarm functions (real time, history, analysis)
Alarm
Focus device function
Internet Explorer Logging monitor / alarm monitor / visual monitor
Monitor
DT STUDIO
Unit monitor / Excel monitor
Cycle / time / time range / bit device/word device / Web / external /
Trigger
combination
XLS/CSV file format
File save
Specified sheet (CSV only), folder category, specified file name
Functions
Mail
File attachment/URL attachment/message transmission/alarm mail
FTP upload
Server transfer
FTP server
Acquire/write Memory Card file
Trigger / browsechange settings / browse Memory Card files /
Web server
Change RUN STOP mode / logging monitor / alarm monitor /
visual monitor
Device transfer / NTP / routing function / Power over Ethernet function /
Memory Card free space management function /
Other
storage data backuprestore function /
erroralarm terminal output function / shutdown function
Buzzer
Off / low / loud
17
Indication
24V
0V
NC
NC
OUT0
OUT1
OUT2
COM(OUT)
IN0
IN1
SHUT DOWN
COM(IN)
Name
24 VDC power input terminal
0 V input terminal
Not connected
Not connected
Error/alarm output terminal 0
Error/alarm output terminal 1
Error/alarm output terminal 2
Output common terminal
Trigger input terminal 0
Trigger input terminal 1
SHUT DOWN input terminal
Input common terminal
0V
NC
OUT1
COM
(OUT)
IN1
COM
(IN)
24V
NC
OUT0
OUT2
IN0
SHUT
DOWN
Input specifications
Specification
26.4 VDC
24 VDC (2.3 mA)
19 V
6V
10 ms
IN
10k
COM
(IN)
1.5k
24V
Photocoupler
isolation
Internal circuit
Item
Max. rated input
Input voltage
Min. ON voltage
Max. OFF voltage
Input time constant
Output specifications
Item
Specification
Internal circuit
Photocoupler
isolation
OUT
Load
COM(OUT)
18
Ethernet port
Ethernet
Item
Description
Communications standard 10BASE-T/100BASE-TX
Communications system
Full duplex/half duplex
Power over Ethernet
(Keyence original)
Power supply
:24 VDC :GND
Max. 300 mA
Pin No.
Signal
name
TD+
TDRD+
Name
PoE switch
Signal
Name
name
RD24V DC
GND
Item
Web software (logging monitor, alarm monitor, visual monitor)
Web server
FTP server
PC application (DT STUDIO)
Ethernet
Item
Description
Communications standard 10BASE-T/100BASE-TX
Communications system
Full duplex/half duplex
II / X
Straight/cross selection
Straight/cross
selector switch
Straight (II)
Cross (X)
Signal name
TD+
TDRD+
Name
Send Data (+)
Send Data (-)
Receive Data (+)
Signal name
RD+
RDTD+
Name
Receive Data (+)
Receive Data (-)
Send Data (+)
RD-
TD-
19
DT-80/80A
General specification
Item
Rated voltage
Current consumption
Description
24 VDC 10%, Class 2
120 mA max. <<190 mA max>>
1500 vp-p pulse width 50 n/1 sec (by noise simulator)
Compliant with IEC standard (IEC61000-4-2/3/4/5/6)
1500 VAC for 1 minute (across power terminal and case)
3000 Mmin. (500 VDC megger across power terminal and case)
Intermittent Vibration
Number of sweeps
Frequency
Acceleration Amplitude
10 to 57 Hz
0.075 mm
2
Compliant with JIS 57 to 150 Hz 9.8 m/s
10 times in each of
B3502 IEC61131-2 Continuous Vibration
X-, Y- and Z-axes
(for 80 mins.)
Frequency
Acceleration Amplitude
Noise resistance
Withstand voltage
Insulating resistance
Vibration resistance
Operating atmosphere
Operating surrounding air
temperature
Operating ambient humidity
Storage ambient
temperature
Storage ambient humidity
Applicable standard
Weight
10 to 57 Hz
0.035 mm
57 to 150 Hz 4.9 m/s2
Excessive amounts of dirt, dust and corrosive gases are not allowed.
0 to +50C (no icing allowed)
35 to 85%RH (no condensation allowed)
-20 to +70C (no icing allowed)
35 to 85%RH (no condensation allowed)
(EMI) EN61326-1, Class A
(EMS) EN61326-1
FCC Part15B, Class A
UL508
Approx. 300 g <<Approx 310 g>>*
Performance specifications
Item
Connectable master
Memory/backup
Function
Data collection
SRAM size
Setup data
Data collection
Trigger
Monitor
Other
Compatible PLC
20
Description
DT-500
Approx. 190 Kbytes
Backup: Primary lithium cell (+25C, service life 10 years or more)
Approx. 1400 Kbytes (100000 rewrites possible)
Logging function/alarm function (notified to master)
Cycle/time/time range/bit device/word device/combination
Visual monitor/cell monitor/main unit monitor (notified to master)
Device transfer, error/alarm terminal output function, DB gateway,
VT/DT thru communications, remote COM port function,
2-port function
Keyence Corporation, MITSUBISHI ELECTRIC CORPORATION,
OMRON Corporation, SHARP CORPORATION,
Fuji Electric Co., Ltd., YASKAWA ELECTRIC CORPORATION,
Hitachi, Ltd., Matsushita Electric Works, Ltd.,
JTEKT Corporation,
KOYO ELECTRONICS INDUSTRIES CO., LTD.,
Yokogawa Electric Corporation, TOSHIBA CORPORATION,
TOSHIBA MACHINE CO., LTD., FANUC LTD.,
GE Fanuc Automation, Rockwell (Allen-Bradley)
Indication
24V
0V
NC
FG
OUT
COM(OUT)
NC
NC
Name
24 VDC power input terminal
0 V input terminal
Not connected
Function ground terminal
Error/alarm output terminal
Output common terminal
Not connected
Not connected
24V
NC
OUT
NC
0V
FG
COM(OUT)
NC
Output specifications
Internal circuit
Item
Specification
Rated output load
30 VDC 100 mA (max.)
Output OFF delay current 100 A or less
Output ON residual voltage 1.5 V or less
Photocoupler
isolation
OUT
COM(OUT)
Serial port
Item
Communications standard
Synchronization mode
Transmission distance
Data length
Parity
Baud rate
Description
RS-232C compliant
Start-stop, full duplex
15 m
7/8 bits
Even/Odd/None
1200 to 115200 bps
*
Pin No.
Load
Signal name
Name
NC
Not connected
NC
Not connected
RD
Receive data (input)
Pin No.
Signal name
Name
SG
Signal ground
SD
Send data (output)
NC
Not connected
Ethernet port
Item
Description
Communications standard 10BASE-T/100BASE-TX
Communications system
Full duplex/half duplex
*
Pin
Signal
No.
name
TD+
TDRD+
Name
Pin No.
Item
PC application (DATA BUILDER)
Signal
name
Name
RD-
21
Description
TXD(SD)
RXD(RD)
RTS(RS)
CTS(CS)
DSR(DR)
SG
TMC1
TMC2
22
DTR(ER)
RS-232C/422A compliant
Name
Not Connected
RS-232C: Send Data
RS-232C: Receive Data
RS-232C: Request to Send
RS-232C: Clear to Send
RS-232C: Data Set Ready
Signal Ground
Terminator
(across and )
RS-232C: Data Terminal
Ready
TXDB
RXDA
RXDB
RTSA
RTSB
CTSA
CTSB
TMR1
TMR2
Name
RS-422A: Send Data A
RS-422A: Send Data B
RS-422A: Receive Data A
RS-422A: Receive Data B
RS-422A: Request to Send A
RS-422A: Request to Send B
RS-422A: Clear To Send A
RS-422A: Clear To Send B
Terminator
(across and )
External Dimensions
DT-500
120
64.5
49.8
145
34.6
(65)
83.5
)
24
(R
145
(Unit: mm)
DT-80/80A
120
32
49.8
34.6
145
3.3
50
(65)
54.5
)
24
(R
145
(Unit: mm)
23
installation
Right side mounting
163.6 174
4-4.5
71.8
25.7
25.7
Thickness of mounting
fixture plate: 1.6
(Unit: mm)
24
174 163.6
Thickness of mounting
fixture plate: 1.6
(Unit: mm)
71.8
4-4.5