“SAANGUINE” Inspection at Kandla

“SAANGUINE”General View from Stern

Stern View
“SAANGUINE” Inspection at Kandla

Starboard Shipside View.

Main Deck Cargo Loaded View


“SAANGUINE” Inspection at Kandla

No. 4 Hold Hatch covers stacked on Port side of the deck

Condition of the Hatch Pontoons, Satisfactory.


“SAANGUINE” Inspection at Kandla

No. 4 Hatch covers stacked on Stbd Side Deck.

General condition of Hatch pontoons, Satisfactory


“SAANGUINE” Inspection at Kandla

STbd Deck Stanchions in folded condition

Main Deck Stanchions in Folded Condition


“SAANGUINE” Inspection at Kandla

No. 3 Hold Coamings and Hatch ways.

Main Deck Condition Stbd Side.


“SAANGUINE” Inspection at Kandla

Stbd Side Bow View

Stern Stbd Side View.


“SAANGUINE” Inspection at Kandla

Shipside inway of Accommodation

Stbd Shipside Condition Satisfactory.


“SAANGUINE” Inspection at Kandla

Stbd Hull from Midship to Fwd.

Shipside In Way of Hold No. 1 and Bow Area


“SAANGUINE” Inspection at Kandla

Bow Area

Bow Area And Bulbous Bow


“SAANGUINE” Inspection at Kandla

Navigational Bridge Forward view

No. 1 Radar Stbd Side.


“SAANGUINE” Inspection at Kandla

No. 2 Radar Port Side.

GMDSS Communication Equipment


“SAANGUINE” Inspection at Kandla

Weather Fax

Chart Table and Computer.


“SAANGUINE” Inspection at Kandla

Auxiliary Oil fired Composite Boiler

Control & Alarm Panel in Engine Control Room


“SAANGUINE” Inspection at Kandla

No. 2 Generator

Fuel Oil and Diesel Oil Purifier.


“SAANGUINE” Inspection at Kandla

No.1 Generator

Main Air Bottles


“SAANGUINE” Inspection at Kandla

Main Eng. Lub Oil Pumps

Stern Tube area at Lower Platform.


“SAANGUINE” Inspection at Kandla

Main Engine Aft at Emergency controls.

Harbour Sea water Pumps (Condition of pipes and valves poor)


“SAANGUINE” Inspection at Kandla

Bilge & Ballast Pump

4th Engineer Attending The Generator.


“SAANGUINE” Inspection at Kandla

Refrigerated Compartments (Temperature Normal)

Lub Oil stored in Drums(Not Lashed properly)


“SAANGUINE” Inspection at Kandla

Steering Gear Save All Tray with Oil

Condensation With Poor Insulation Covered With Plastic


“SAANGUINE” Inspection at Kandla

Main Engine Used Spare Piston

Spare Piston Rod Need Recondition Prior Use


“SAANGUINE” Inspection at Kandla

Main Engine Cylinder Heads & Exhaust valves

Fresh Water Generator


“SAANGUINE” Inspection at Kandla

Water Leak from Pipe and accumulation Near Fresh Water Generator

Boiler Hot-well Clear of Oil


“SAANGUINE” Inspection at Kandla

Generator Save All Tray Oily

Generator Stbd Side.


“SAANGUINE” Inspection at Kandla

Leaky Sea Water pipes of Fresh Water Cooler

Both Generator CJC Filters are not in USE


“SAANGUINE” Inspection at Kandla

Generator Below Turbo Charger Oily and Dust collected a Fire Hazard

Fuel Oil Purifier And Save al tray Accumulation of Fuel Oil.


“SAANGUINE” Inspection at Kandla

Oil leak from Leaky seal of Auxiliary Blower

Lower Platform of Stbd Side and Lub Oil Purifier


“SAANGUINE” Inspection at Kandla

Stern tube Circulating Pump, Both Pressure gauges are Damaged

Poor Condition of the Sea Watere Pipes and Valves.


“SAANGUINE” Inspection at Kandla

Sea Water Lines leaking and temp repairs

Sea Water Pipe Condition and Temp. Repairs.


“SAANGUINE” Inspection at Kandla

Sea Water Lines.

Fresh Water Generator Ejector Pump and Suction lines.


“SAANGUINE” Inspection at Kandla

Spare Aux Engine Cylinder head (CE Says can not be used) Require Investigation.

Spare Generator Pistons


S
“SAANGUINE” Inspection at Kandla

Spare M/Eng Exhaust valves.

Chemicals Stored in Store.


“SAANGUINE” Inspection at Kandla

Chemicals Stored in Store

CO2 Release valves to Cargo Holds.


“SAANGUINE” Inspection at Kandla

CO2 Flooding Master Valve to E/Room

CO2 Bottles Inspected in Jan 2008


“SAANGUINE” Inspection at Kandla

E/Room Bilge Pump

Fuel Oil Leak on Tank Top.


“SAANGUINE” Inspection at Kandla

M/Eng No. 1 Fuel Pump Leaky

Garbage Drums on deck (Poop Deck) Found Empty.


“SAANGUINE” Inspection at Kandla

Gas Bottles and Connection at Poop Deck.

Crew Common Toilet


“SAANGUINE” Inspection at Kandla

EEBD found Satisfactory

Emergency Fire Pump (Accumulation of Water in the room)


“SAANGUINE” Inspection at Kandla

Oily Garbage accumulated in Work Shop

Grinder has High Clearance need be adjusted.


“SAANGUINE” Inspection at Kandla

Oil Rags collection and leaks

Accumulation of Oil in Save all Tray


“SAANGUINE” Inspection at Kandla

Generator No. 1 Save oil tray Oil accumulated

Generator Save all tray


“SAANGUINE” Inspection at Kandla

Leaky Fuel Oil Transfer Pump

Fuel Transfer Save All Tray


“SAANGUINE” Inspection at Kandla

EEBD Inspection not carried out from 23 Sept 2009

Sea Water Line Leak with temp repair


“SAANGUINE” Inspection at Kandla

Aft Bilge well filled with Oil.


“SAANGUINE” Inspection at Kandla

Sounding pipe Self closing cocks lashed up.

Bilges with Oil


“SAANGUINE” Inspection at Kandla

Oil in Bilges

Oily Water Seperator


“SAANGUINE” Inspection at Kandla

Emergency Fire Pump Suction in E/Room

Oil Traces inside the Bilge Overboard line.


“SAANGUINE” Inspection at Kandla

Damaged Steam pipe Insulation

SOPEP Locker
“SAANGUINE” Inspection at Kandla

Fore Peak Tank Internals

Fore Peak Tank Coating Poor and Rust Patches


“SAANGUINE” Inspection at Kandla

Fore Peak Tank

Fore Peak Tank


“SAANGUINE” Inspection at Kandla

Fore Peak Tank

Fore Peak Tank


“SAANGUINE” Inspection at Kandla

Fore Peak Tank

Fore Peak Tank


“SAANGUINE” Inspection at Kandla

Fore Peak Tank

Fore Peak Tank


“SAANGUINE” Inspection at Kandla

Fore Peak Tank

Fore Peak Tank


“SAANGUINE” Inspection at Kandla

Fore Peak Tank

Fore Peak Tank


“SAANGUINE” Inspection at Kandla

No. 3 Top Side Tank


“SAANGUINE” Inspection at Kandla

Wasted Longitudinals

Top Side Frame Rust patches.


“SAANGUINE” Inspection at Kandla

Top Side Tank Transverse Frames.

Wasted Sloping plate