SILYZER 200 (PEM electrolysis system)

Sales slides

Unrestricted / Siemens AG 2015. All Rights Reserved.

siemens.com/hydrogen-electrolyzer

SILYZER PEM electrolyzer is a key component to


solve the sustainability challenges of today

Yesterday

Today

Solution

demand driven, conventional


electrical power generation;
negligible share of renewables; no storage required

increasing share of renewables; waste of excess


energy; mid- and long-term
energy storage mandatory

efficient integration of
renewables and avoidance
of energy waste by making it
long-term storable

more than 98% of hydrogen


production based on CO2
intensive steam reforming

commitment to CO2
reduction targets, constant
growth of hydrogen market

global transportation based


on gasoline and diesel only

innovative e-mobility
concepts

CO2 free production of


Green hydrogen for all
industrial requirements and
to support sustainable, zero
emission transportation
solutions

Unrestricted / Siemens AG 2015. All Rights Reserved.


Page 2

12.02.2015

PD LD HY S

SILYZER completes energy storage portfolio and


supports tailored solutions for all major industries
Key Statements
NEW
SILYZER 200
/ Methane

Large scale storage can only be


addressed by Pumped Hydro,
Compressed Air (CAES) and
chemical storage media like
Hydrogen and Methane
The potential to extend pumped
hydro capacities is very limited
Hydrogen is used in many main
industries as a reductive or
protective gas or is used as an
input in synthesis processes;
onsite hydrogen production is a
promising alternative to
trailer/truck supply

The future CO2-optimized energy scenario will require smart solutions


Unrestricted / Siemens AG 2015. All Rights Reserved.
Page 3

12.02.2015

PD LD HY S

SILYZER and hydrogen together are an unbeatable


combination to achieve major targets

Increasing revenues
+
and turnover
due to extremely dynamic
operation behavior, SILYZER
can be used as a load within
intelligent energy management
systems (EMS) for the grid

Environmental protection +
local onsite production of
CO2-free hydrogen without
using hazardous material,
such as caustic potash,
avoids extensive transports

Optimization of costs
+
low OPEX and total Costs of
Ownership (TCO) due to
minimal installation efforts,
maintenance-free stacks,
clean and safe operation,
robustness, pressurized mode
until 35 bar, lifetime specified
with more than 80.000 hours

Investment protection
+
utilization of wind energy
turbines or solar panels
even during forced
curtailment periods due to
grid imbalance increases
operation hours and delivers
hydrogen as a valuable
product further more

Unrestricted / Siemens AG 2015. All Rights Reserved.


Page 4

12.02.2015

PD LD HY S

SILYZER produces hydrogen as a multi-purpose


energy carrier for industry, mobility and grid services
H2 production: no CO2, independent, efficient , onsite

Chemical synthesis (e.g. ammonia, fertilizer, methanol)


Petrochemical processes (e.g. cracking)
Flat glass, nonferrous metal (protective and reductive gas)
Food & Beverages (hardening)

H2 application: a sustainable fuel for transport concepts

CO2 free mobility; Renewable fuel concepts


Sustainable and pollution-free Public Transport
Fuel Cell based in-plant logistics (forklifts, floor conveyors)
Reliable, safe e-mobility: fast-to-refuel cars with long ranges

H2 conversion: stabilizes the power grid

Grid balancing capability (dynamical behavior in milliseconds)


Optimization of asset utilization in renewable energies
Storage of medium- and long-term overcapacities (TWh)
Power-to-hydrogen and Power-to-gas as future key concepts

Unrestricted / Siemens AG 2015. All Rights Reserved.


Page 5

12.02.2015

PD LD HY S

PEM water electrolyzer technology


a perfect match with renewable energy requirements
to convert electrical into chemical power

(e.g. fossil, nuclear)

H2 drives the convergence between energy & industry markets


Unrestricted / Siemens AG 2015. All Rights Reserved.
Page 6

12.02.2015

PD LD HY S

Leading edge features allow a robust, efficient and


safe operation
Feature / Function

Benefit

Dynamic, flexible
behavior; operation
connectable to volatile
power generation
(wind/solar)

No pre-heating or holding
needed; load ramps not
limited; match with any
gradients; time to reach
power set point: 10 sec.

No investment for
compressor units necessary;
no further requirements or
safety precautions

Safe and pressurized


operation with up to 35
bar
Modular design and
easily expandable up to
20 MW and more;
technical options offered
to achieve all
requirements

One stop shopping for the


entire project;

www.siemens.com/hydrogen-electrolyzer
https://www.youtube.com/watch?v=fKgLMvVuUA

Unrestricted / Siemens AG 2015. All Rights Reserved.


Page 7

12.02.2015

PD LD HY S

SILYZER provides best-in-class PEM technology


with a large-scale and industrialized design

Maintenance

No caustic potash
No leaching

Dynamic

Cycles 0 % .. 160 % without


relevant aging

Size

High current density


allows compact
construction

No precipitation
+
+

Operating costs

Highest dynamic for lowest


current prices

No inert gas flushing


No protection current
No preheating

Lifetime

Tentatively less corrosion


+

Long lasting electrodes

Operability

Construction

Modular, scalable

Pressure

High System pressures


No additional
compression costs

Industrial standards
Unrestricted / Siemens AG 2015. All Rights Reserved.
Page 8

12.02.2015

PD LD HY S

Outstanding performance paired with technical


options allows integration in any project scope
Main Technical Data - SILYZER 200

Electrolysis type / principle

PEM

Rated Stack Power

1.25 MW

Dimension Skid

6,3 x 3,1 x 3,0 m

Start up time (from stand-by)

< 10 sec

Output pressure

Up to 35 bar

Purity H2
(depends on operation)

99.5% - 99.9%

H2 Quality 5.0

DeOxo-Dryer option

Rated H2 production

225 Nm/h

Overall Efficiency (system)

65 70 %

Design Life Time

> 80.000 h

Weight per Skid

17 t

CE-Conformity

yes

Tap Water Requirement

1,5 l / Nm H2

Unrestricted / Siemens AG 2015. All Rights Reserved.


Page 9

12.02.2015

PD LD HY S

Energiepark Mainz Project scope and key facts

Location: Mainz-Hechtsheim (DE)

Three high performance


electrolysis systems with peak
power of 2 MW el. each
(6 MW peak)

Connection to 10 MW wind-farm

1000 kg storage (33 MWh)

200 tons target annual output


(Trailer-filling station and injection
into local gas grid)

Highly dynamic operation over


broad load range (ramp speed
10% per sec.)

Next steps:
Commissioning 1st half 2015
Unrestricted / Siemens AG 2015. All Rights Reserved.
Page 10

12.02.2015

PD LD HY S

Do you also want to increase the overall efficiency


and sustainability of your plant?
Ask us now how it can be done!

Unrestricted / Siemens AG 2015. All Rights Reserved.


Page 11

12.02.2015

PD LD HY S