Professional Documents
Culture Documents
101h2020 1
101h2020 1
101h2020 1
4
U
3
PHASE
SUPPLY
3
6
5
T ap
FS1
C1
W
X
Y
Z
C2
W
RWS100
TR AN S F OR ME R TAP P IN G OP TION S
Nominal 50/60Hz
TYP E 1
220/230
380/400
400,415/420
440/460
F US E F S 1= 250mA A NTI-S UR G E
PS1
120VAC 4
0VDC
3
24VDC 6
SK2
0VAC 1
SK14
0VDC 1
24VDC
24VDC
NOMINAL SUPPLY
(OUTPUT)
INTERNAL SUPPLY
FOR CPT PCB
W
X
Y
Z
TYP E 2
346/380
480/500
240/240
550/575
F US E F S 1= 250mA A NTI-S UR G E
X
Y
TYP E 3
660/660-690
690/-
F US E F S 1= 150mA A NTI-S UR G E
SK13
26 WAY
SK13
SK3
6
TORQUE
SENSOR
MONITOR RELAY
4
3
2
1
SK8
POSITION
SENSOR
10 WAY
BATTERY
SK14
1
S1
S2
S3
S4
18 WAY
STOP
CLOSE
LOCAL
OPEN
REMOTE
7
8
9
10
11
6
4
12
13
OPEN
COMMON -VE
ESD
12
OPEN INTERLOCK
13
CLOSE INTERLOCK
14
COMMON -VE
www.
SK1
SLOT A
SK1
SLOT C
44
33
34
10
STOP/ MAINTAIN
SK6
43
SK4
9
CLOSE
50%
SK7
1
42
35
36
25
37
38
31
SK2
SLOT B
SK2
SLOT D
.com
Tel:01225-733200
Tel:585-247-2304
Job No : - MI No : - -
101H2020
B1 C1 B2 C2 B1 C1M1V1 B1 C1M1V1
Issue
No
Sheet
1
of 2
IQ3
HART
(REFER TO
MANUAL
PUB092-003)
SLOT A
SK3
1
26 DEMAND +
27 DEMAND
29 SCREEN
32
SLOT B
SK2
SLOT B
E
SK3
+VE
22
CPT
-VE
23
SK6
0V
24V
1
2
SK8
1
2
SLOT C
SK1
SLOT C
2
MAKE AT FULLY SHUT
S5
14
16
1
5
MAKE AT FULLY OPEN S6
17
19
4
MAKE ON TORQUE
TRIP S7
20
24
7
MAKE WHEN REMOTE
SELECTED
30
11
S8
12
47
10
SLOT D
EXTRA RELAY CONTACTS
SK3
SK2
SLOT D
SK3
1
MAKE AT FULLY SHUT
S9
MAKE ON TORQUE
TRIP S11
15
18
21
39
40
41
10
45
11
46
NOTES
1.FUSES:
-PS1 is a self-resetting fuse.
-Refer to publication PUB002-039 for approved fuses FS1 and FS2.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%,
applies for rated torque performance; duty cycle is not guaranteed.
2.REMOTE CONTROL:
-For typical remote control circuits refer to:
-RWS indicated or PUB002-041.
-For DC and AC control, connect ve/0V to terminal 36.
-(For negative switch / positive common, refer to RWS indicated).
-Control signal threshold voltages:
-DC: on 16Vdc / off 8Vdc, max 60Vdc.
-AC: on 60Vac / off 40Vac, max 120Vac.
-Control signal duration to be 300ms minimum.
-Maximum current drawn from remote control signals is:
-8mA at 24Vdc or 12mA at 120Vac.
-Supply provided on terminals 4 & 5:
-Intended for remote control.
-Max external load 5W at 24Vdc / 5VA at 120Vac
3.INDICATION:
-For typical position, status and alarm indication see PUB002-041.
-S contacts are user configurable and are shown in their default
setting.
-Refer to PUB002-040 for functions and configuration instructions.
-Monitor Relay indicates actuator availability for remote control (shown
unavailable). It can be configured to exclude local/remote selection.
-Refer to PUB002-040 for monitored functions and configuration
instructions.
-Voltage applied to indication contacts must not exceed 150Vac
-Individual Switch current must not exceed 3.5A inductive, 5A resistive
and no more than 8A in total for all 4 contacts.
4.BATTERY:
-Battery maintains local and remote S contact indication only.
-Refer to installation manual for approved replacement battery types.
Issue
No
101H2020 1
Sheet
2
of 2
IQ3