Professional Documents
Culture Documents
SISTEMA Onda Portadora
SISTEMA Onda Portadora
SISTEMA Onda Portadora
from experience
Power-line Carrier and
Teleprotection solutions
for power utilities
Description
Power-line Carrier and
Teleprotection solutions
for power utilities
Introduction
Power line carrier systems for HV
lines are part of the power utilities
communication network. They are
used to transmit critical information
related to the operation of the electrical
system: teleprotection signals, speech,
telegraphy, remote measurements and
telecontrol (SCADA signals). Power
line carrier technology has proven to
be the most reliable communication
media, even when natural disasters
happen, thanks to its robustness
and the reliability of the electronic
equipment that has been engineered
for an extremely long life.
ZIV
COMMUNICATIONS
wide
experience and extense product range
for power line carrier and teleprotection
applications, enable easy adaptation
to power utility requirements.
ZIV COMMUNICATIONS
portfolio includes:
product
Solutions born
from experience
ZIV COMMUNICATIONS
wide experience and
extense product range
for power line carrier
and teleprotection
applications, enable easy
adaptation to power utility
requirements
OPU1
Solutions born
from experience
Key features
Modular design
Complies with IEC 60495 and IEC
61000-6-5 standards
Simultaneous
transmission
of
analog and digital channels including
teleprotection
Frequency range of 36 kHz to 512kHz
(from 30 kHz to 1016 kHz upon
request)
QAM or OFDM for best compromise
between SNR, BW and transmission
rate
Independent bands to overcome
congestion solution and special
topology applications
10 ms internal latency in QAM mode
1 or 2 standard 4 kHz channels in each
direction
Integrated
FEC
optional
Reed-Solomon
SNMP agent
Web Management system with LAN
connection
Cascaded internal service channel
IRIG-B
port
synchronization
for
GPS
time
OPC-2
Multi-function platform
HF Teleprotection Functionality
The High-Frequency Teleprotection
functionality enables electrical power
utilities to transmit teleprotection
commands over high-voltage lines,
in only one standard 4 kHz channel,
using 2 kHz for transmission and 2 kHz
for reception.
The OPC2 platform allows three
nominal transmission times to be
programmed. The system meets
the
security
and
dependability
requirements specified in IEC 60834-1
Recommendation for the three types
of teleprotection command schemes:
Permissive
tripping
schemes,
Intertripping schemes (Direct or
transfer
tripping)
and
Blocking
protection schemes.
Solutions born
from experience
Key features
(SSB)
with
IRIGB
port
synchronization
for
GPS
time
for
end-to-end
A single platform
with two applications:
PowerLine Carrier
functionality
(telecontrol/SCADA
Three
programmable
nominal
transmission times depending on
application
teleprotection signals)
From 1 to
(optocoupled)
command
inputs
OPL-1
OPL-1T
Smallsize Analog
PowerLine Carrier Terminal
Key features
Single 5 U chassis for 20 W and 40 W
and two 5 U chassis for 80 W models
Key features
Small-size design
A single 5 U chassis
20 W and 40 W PEP
and,
optionally,
for
GPS
time
for
end-to-end
Analog
Power-Line Carrier Terminal
for
GPS
time
for
end-to-end
with
with
Solutions born
from experience
External
ZIV COMMUNICATIONS
offers a wide range of
Power-line Carrier Systems
TPU-1
for
10
Key features
Modular design
Complies with IEC 60834-1 and
IEC61000-6-5 standards
Complies with ANSI IEEE C37.90.1
and ANSIIEEEC37.90.2 standards
Compatible with IEC 61850 standard
(optional)
IP communications interface for
connection to IP networks (optional)
SNMP agent
Extremely
high
security
and
dependability
Two independent teleprotection
terminals (in a single chassis)
Operates over analog and/or digital
channels
Up to four commands in analog
channels; Power-Line Carrier links,
telephone cables, radio links, etc.
Operation using tones or FSK
channels or encoded commands
Up to eight commands in digital
channels; E1/T1 interfaces (G.703),
64 kbit/s (G.703, V.11 or V.35 or
X.21), 64 kbit/s single-mode optical
fiber (9/125 m, 1300 nm or 1550
nm), and C37.94 multimode optical
fiber (62,5m, 830 nm)
Input and output logic programmable
by the user (up to sixteen analog
inputs and outputs and optional
up to sixteen inputs and outputs
in accordance with IEC 61850
standard)
Can be used for blocking, direct and
permissive tripping schemes as well
as for telesignalling systems
Specific modules for telesignalling
and remote measurements
Command transits in a ring and in T
(Teed-line)
IRIG-B
port
for
GPS
time
synchronization
Synchronization via Ethernet using
the NTP protocol
Sequence of Events register (1400
alarms and events) with 1 ms
resolution
Web management system with LAN
connection
Internal channel for end-to-end
supervision
Signalling
and
alarm
relays
programmable by the user
Built-in or cabinet-mounted terminal
blocks
Optional features such as LCD screen
for command-counters, power-supply
redundancy, and more.
Solutions born
from experience
TPU-1C
CTP-1
Up to 32 commands
Operates
channels
Encoded Teleprotection
Small-size Teleprotection
over
analog
or
digital
Key features
Small-size design
Complies with IEC 60834-1 and IEC
61000-6-5 standards
Complies with ANSI IEEE C37.90.1
and ANSIIEEEC37.90.2 standards
Extremely
high
dependability
security
and
over
analog
or
digital
for
GPS
time
for
end-to-end
Signalling
and
alarm
programmable by the user
relays
The
ZIV COMMUNICATIONS
teleprotection terminals
provide an optimal
combination of security,
dependability and
transmission time
11
Madrid:
C/ Diego Marn Aguilera 14
Pol. Legans Tecnolgico
28918 Legans, Madrid
Tel.: +34 91 352 7056
Fax: +34 91 352 6304
Barcelona:
C/ Antonio Machado, 78-80
Viladecans Business Park - Edificio Australia
08840 Viladecans, Barcelona
Tel.: +34 93 349 07 00
Fax: +34 93 349 22 58
communications@ziv.es
http://www.communications.ziv.es
Sevilla:
Avda. de la Aeronutica, 10
(Edificio Helios) Planta 7, mdulo 4
41020 Sevilla
Tel.: +34 954 461 360
Fax: +34 954 462 484
Las Palmas:
Fernando Guanarteme 16. Ofic. 1 A
35007 Las Palmas de Gran Canaria
Tel.: +34 94 452 20 03
http://www.ziv.es
Spain
Headquarters (ZIV Group):
Parque Tecnolgico, 210
48170 Zamudio, Vizcaya
Tel.: +34 94 452 20 03
Fax: +34 94 452 21 40
http: //www.ziv.es
Mexico:
Horacio No. 1213
Col. Polanco, Delegacin Miguel Hidalgo
C.P: 11550 - Mxico D.F.
Tel.: +52 044 (55) 58 26 76 44
Fax: +52 (55) 55 31 51 72
Russia:
Krimsky Val, d 3,
str 2, office 514.
119049 Moscow
Tel.: +7 495 642 63 12
Singapore:
10 Anson Road No. 25-07
International Plaza
Singapore 079903
Tel.: +65 6410 9625
Fax: +65 6410 9631
http://www.communications.ziv.es/
ZIV continually strives to improve products and services. The technical information included in this document is subject to change without notice.