RANGE OF USE

Manometric head up to:

52 m

10 to + 110C

Temperature range:

32 to 100

nominal diameter ports:

0,10

MEI* of reference:

*Minimum Efficiency Index

APPLICATIONS

100
52

SINGLE AND DOUBLE


IN-LINE PUMPS
Heating - Air conditioning
50 Hz

10 bar

Maximum working pressure:

Hm

LRN - JRN

200 m3/h

Flows up to:

Heating multiple dwellings


Air conditioning

LRN - JRN

Qm3/h

SIL - DIL

200

Many industrial and agricultural applications.


Heating greenhouses
Transferring antifreeze
Circulating iced water.

1100

ADVANTAGES
Low electrical consumption.
Mounts directly onto horizontal or vertical pipework.

Not coupled: no need to align the
shafts.

Device to de-aerate the mechanical
seal.
Easy and quick to install.
Practically zero maintenance.
JRN
A backup pump permanently available.

The two pumps can be operated in
parallel to increase the flow.
M anual or automatic pump switchover
by MGP box .

LRN- JRN: vertical motors

N.T. N 124-11/ENG. - Ed. 6/10-14

LRN - JRN
DESIGN

LRN - PLAN AND CROSS-SECTION

Hydraulic part
-Centrifugal, single-stage.
-Intake and outlet ports in line.
-
Flanged pump housing with ports for
connecting pressure gauges.
-Bearing lantern linking pump to motor.
-D ynamically balanced impeller, mounted
directly on the shaft of the motor.
-Waterproof mechanical seal.

2
2

JRN
-Double pump in one housing.
-The two pumps are hydraulically separated
by silent-operating valve.
Motor
-IE2
-One end of shaft lengthened.
-The rotor shafts guide bearings selected for
silent operation.

Speed:
2900 rpm
3 ~winding = 3kW: 230V

400V Y
Three-phase 4kW: 400V
Frequency:
50 Hz (option 60 Hz)
Insulation class:
155 (F)
Protection class:
IP 55
EC Compliant:
EN 809

1
2.1

1.1
1.14
1.14

Material

Pump housing

Cast iron EN GJL 250

Bearing lantern

Cast iron EN GJL 250

Shaft

Steel X20 - Cr13

Mechanical seal

Graphite/ Carbide Si/EP

Impeller

Cast iron EN GJL 200

IDENTIFICATION
LRN 2 05 - 17/7.5
JRN

1.21

1.13
1.1

1.2

1.11

1.11

3.2

3
3.1+1.14

single/double pump
2 = 2 pole: 2900 rpm
4 = 4 pole: 1450 rpm
Nominal diam. of ports (cm)
Nominal diam. of the impeller (cm)
Motor power (kW)

1.12

1.12

BASIC CONSTRUCTION
Main components

LRN

LRN - JRN
PART LIST

JRN - PLAN AND CROSS-SECTION

common to LRN - JRN

1. Complete replacement kit


1.1 Set of spare parts for impeller with
1.11 Nut
1.12 Washer
1.13 Impeller
1.14 O-ring
1.2 Set of spare parts for mechanical seal
with:
1.11 Nut
1.12 Washer
1.14 O-ring
1.21 Complete mechanical seal
2. Replacement motor kit
2.1 Air bleed screw

2.1
1

3. Complete pump housing with


3.1 Pump housing (LRN, JRN)
3.2 Bouchon pour prise de pression
3.3 Directional valve nominal diameter
80 (JRN pumps only)
1.14
3.4 Directional valve nominal diameter
100 (JRN pumps only)

1.14

1.14

1.13

1.21

1.12

1.12

1.11

1.11

1.1

4. Retaining screw for flange of 1.21


the motor /
pump housing (also included in the motor
1.2
kit).

1.2

3.4
DN100

1.12

1.11

3.3
DN80
3

3.2
+1.14

3.1

LRN

JRN

LRN - JRN
LRN - GENERAL PRESELECTION DIAGRAMS
LRN

Hm

50Hz
2900 rpm
tr/min

50
LRN 204
40
LRN 203
30
LRN 205
LRN 206

20

LRN 208
10

10

20

30

40

50

60

70

80

90

100

110

120

140

130

150

160

170

180

Hm

190 Qm/h

LRN

50Hz
1450 rpm
tr/min

9
8
7
6
5
4
LRN 410

3
2
1
0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

Qm/h

FITTING POSITIONS

mounted directly onto horizontal or vertical pipework

Pay attention to the position of the


bleed screw: always upwards.

LRN - JRN
LRN - GENERAL PRESELECTION DIAGRAMS
Hm

JRN

50Hz +
2900 rpm
tr/min

50
45
40
35

JRN 205

30

JRN 203

25

JRN 204
JRN 206

20
15

JRN 208

10
5
0

10

20

30

40

50

60

70

80

90

100 110 120 130 140 150 160 170 180 190 200 210 220 Qm/h

Hm

JRN

50Hz +
1450 rpm
tr/min

8
7
6

JRN 410

5
4
3
2
1
0

10

20

30

40

50

60

70

80

90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 Qm/h

FITTING POSITIONS

mounted directly onto horizontal or vertical pipework

* Do not fit a butterfly valve directly onto the outlet flange
so as not to hamper the operation of the valve.
Pay attention to the position of the bleed screw: always
upwards.

LRN - JRN
HYDRAULIC PERFORMANCE LRN 2-POLE
45
40

LR

35

N2

30

LRN

25

17/

203

/3

NPSH m

P2 kW
3
2
1
0

15

20

25
6

30 Qm/h

14
12
10
8
6
4
2
0

Ql/s

10

15

20

10

15

20

25

30

35

40

Qm/h

45

Ql/s

10
168

155

10

15

20

25

30

35

40

60
40
20
0

10

15

20

30 Qm/h

25

Qmin

LRN

45

204-

168

10

15

20

25

Hm

LRN 204 20/7,5 - DN 40

30

35

LRN

25

,5

40

40

Qm/h

45

LRN 205 14/4 - DN 50

Qmin

30

20/7

Qm/h

45

50

205

-14

/4

20

35
30

15

20

NPSH m

195

15
10

5
0
0

5
1

10
2

15
4

20
5

25
6

30
8

35
9

10

Qm/h
11 Ql/s

195

10

15

20

25

30

35

%
60

Qm/h

195

40
20
0

10

15

20

25

30

35

Qm/h

10
8
6
4
2
0

10
5
0

P2kW
4
3
2
1
0

141
0

10

15

20

25

30

35

40

45

50

10

55

NPSH m

25

30 Qm/h

25

173

55

168

14
12
10
8
6
4
2
0

Hm
60

6
4
2
0

/5,5

16/4

20

P2 kW

-17

204-

10

P2kW

173

40

204

15

157

%
60

LRN

20

173

10

LRN

25

-16

10

40

30

15

LRN 204 16/4 to

LRN 204 17/5,5 - DN 40

Qmin

35

03-

20

Hm
45

LRN 203 16/3 to

LRN 203 17/4 - DN 32

Qmin

NPSH m

Hm

Qm/h
Ql/s

15

141

%
80
60
40
20
0
0

10

15

20

25

30

35

40

45

50

55

Qm/h

141

10

15

20

25

30

35

40

45

50

55

Qm/h

10
8
6
4
2
0

LRN - JRN
HYDRAULIC PERFORMANCE LRN 2-POLE
Hm
45

Qmin
LRN 205-17/5,

40

LR

35

30

LR

25

20

50

5-1

45

6/5

,5

30
25

,5

20

0
P2 kW
8
6
4
2
0
0

10
2

20
4

30

40
10

50

12

60

14

16

18

20

20

30

40

50

60

22 Ql/s

70

%
60

P2 kW
8
6
4
2
0

Qm/h

20
10

20

30

40

Hm
Qmin

30
25

50

60

70

LRN 206-14/5,5

20

N2

15

061

06

3/5

-14

/7,

P2 kW
8
6
4
2
0
%
80
60
40
20
0

40

50

60

10

70

80

20

10

20

30

40

50

60

70

20

Ql/s

30

80

140

90 100 110 120 Qm/h


140

10

20

30

40

50

60

70

80

25

30

35

40

90 100 110 120 Qm/h

15
10
5
0

45

184

10

15

20

25

30

35

40

45

50

%
80
60
40
20
0

Qm/h

184

Qmin

10

15

20

LRN 206-16

/5,5

25

30

35

40

45

50

LR

N2

LR

06-

N2

06-

16/

7.5

15/

5.5

152

20

40
10

Qm/h

LRN 206 15/5,5 to

LRN 206 16/7,5 - DN 65

P2 kW
8
6
4
2
0

10
8
6
4
2
0

15 Ql/s

10

Qm/h

50

10

20

90 100 110 120 Qm/h

126

20

15

5
30

15

35

,5

140

20

10

25

10

10

30

N2

LR

Hm

LRN 206 13/5,5 to

LRN 206 14/7,5 - DN 65


LR

Qm/h

NPSH m

184

%
80
60
40
20
0
0

167

40

10

167

157

10

Qm/h

70

15
NPSH m

12

60
15

100 Qm/h

80
20

NPSH m

NPSH m

167

10

LRN 205 18/7,5 - DN 50


LRN 205-18/7,5

35

7/7

15

Qmin

40

20

5-1

20

Hm

LRN 205 17/7,5 to

LRN 205 16/5,5 - DN 50

10
8
6
4
2
0

Ql/s

25
152
134

20

40

60

80

100 Qm/h
152

20

40

60

80

100 Qm/h

LRN - JRN

Hm
26
24
22
20
18
16

P2kW
8
6
4
2
0
%
80
60
40
20
0

LR

N2

LR

N2

08

-13

08

-14

20

40

60

10

80

20

LR

LR

/5,

100

LRN 410 14.5/1,1 to

LRN 410 17/3 - DN 100

Qmin

10

/7,

134

Hm

LRN 208 13/5,5 to

LRN 208 14/7,5 - DN 80

Qmin

120

140

30

NPSH m

14
12
10
8
6
4
2
0

HYDRAULIC PERFORMANCE LRN 4-POLE

Qm/h
Ql/s

40

122

134

12
10
8
6
4
2
0

LR

LR

2
0

P2 kW
3

0
0

40
10

0-

30

20

40

60

80

100

120

140

Qm/h

134

20

40

60

80

100

120

140

Qm/h

17

/3

/2,

40

80

120

200 Qm/h

160

Ql/s

50

145
135
0

175

40

1
0

0-

120

2
0

41

16

41
41 0-15
0-1 /1
4,5 ,5
/1,
1

80
20

41

NPSH m

HYDRAULIC PERFORMANCE LRN 2-POLE

160

165

175

200 Qm/h

%
80
60
40
20
0

175
0

40

80

120

160

200 Qm/h

6
4
2
0

LRN - JRN
HYDRAULIC PERFORMANCE JRN 2 POLE

40
35

JR

30

N2

03-

0316/

20

17/

30

15

20

25

156

2
0

10

15

Qm/h

15

20

10

10

Ql/s

P2 kW
4

NPSH m

171

30

20

25

6
4
2
0

Qm/h

%
40
30
20
10
0

Hm

10

15

25

40
30
20
10
0

Qm/h

JRN 204 16/4 to

JRN 204 17/5,5 - DN 40

Qmin

45

20

40

JR

N2

35

JR

30

N2

25

04-

04

-17

16/

0
0

10
2,5

20
5

30
7,5

40
10

NPSH m
50 Qm/h

12,5

Ql/s

168
155
10

20

30

%
60

40

30

Qm/h

50
6

20
10
0

Ql/s

171

156

10

20

30

40

Qm/h

50

171

10

20

30

40

30
20
10
0

50 Qm/h

JR

JR

20

20

4-

4-1

17

/5,

6/4

15

40
168

10
5
0

0
P2 kW
12

0
%

20
5

40
10

60
15

100 Qm/h

80
20

25

30
20
10
0

Ql/s

168
155

20

40

Qm/h

60

168

40

20

Qm/h

50

JRN 204 16/4 to

JRN 204 17/5,5 - DN 40


+

Qmin

168

40

/4

/3

4
0

17

16

25

168

3-

40

20

30

30

40

4
0

20

35

15

P2 kW
6

10

40

20

45

3-

171

Hm

/5,

10

20

20

171

0
P2 kW

171

JR

20

5
10

JR

25

10

40

15

JRN 203 13/3 to

JRN 203 17/4 - DN 32


+

Qmin

35

N2

JR

25

Hm
45

JRN 203 16/3 to

JRN 203 17/4 - DN 32

Qmin

NPSH m

45

NPSH m

Hm

20
0

10

20

30

40

50 Qm/h

20

40

60

80

100 Qm/h

LRN - JRN
PERFORMANCES
HYDRAULIC
PERFORMANCE
HYDRAULIQUES
JRN 2JRN
POLE
2 PLES
Hm
Qmin

60

Hm

JRN 204 20/7,5 - DN 40

50

JRN

40

60
50

204-

20/7

20/

7,5

10

20

2,5

30

Qm/h

7,5

20
10
0

Ql/s

10

20

30

Qm/h

Hm

10

20

40
30
20
10
0

Qm/h

28

JRN

24

20

32

-14

8
4

136

2,5

10

40
12,5

50 Qm/h
15

Ql/s

P2 kW

NPSH m

16

136

2
0

10

20

30

40

50 Qm/h

12
8
4
0

20

136

10

20

30

40

50 Qm/h

Ql/s

60

Qm/h

80

20

40

60

Qm/h

80

JRN 205 14/4 - DN 50


+

Qmin

JR

20

5-1

4/4

12
8
4
0

P2 kW
6
4
2
0

16

136

12

20

40
10

60
15

Qm/h

80
20

Ql/s

25
136

20

40

60

80

100 Qm/h

%
60
40
20
0

40

24

/4

12

30

15

28

205

16

20

20

16

10

10

Qm/h

80

10

194

20

60

20

194

20

40

Hm

JRN 205 14/4 - DN 50

Qmin

32

30

194

12
8
4
0

30
194

10

P2 kW

194

20

NPSH m

P2 kW

10

04-

NPSH m

194

NPSH m

30

10

40
30
20
10
0

N2

30

20

JR

40

,5

30

JRN 204 20/7,5 - DN 40


+

Qmin

60
40
20
0

136

20

40

60

80

100 Qm/h

8
4
0

LRN - JRN
HYDRAULIC PERFORMANCE JRN 2 POLE
Qmin

45

JRN 205-17/5,5

40

JRN 205 16/5,5 to

JRN 205 17/7,5 - DN 50

Hm
40

35

JR

30

N2

JR

N2

25

-17

/7,

-16

25

/5,
5
166

40

Qm/h

60

10

20
16
12
8
4
0

Ql/s

15
157

20

40

Qm/h

60

10

20
5

40
10

60
15

100 Qm/h

80
20

20
16
12
8
4
0

Ql/s

25
166
157

20

40

60

100 Qm/h

80

166

40

20

20

Hm

20

40

Qm/h

60

JRN 205 18/7,5 - DN 50

Qmin

50

JRN

40

8/7,5

20

10
183

2,5

20
5

30
7,5

40
10

50

NPSH m

20

10

Qm/h

8
4
0

P2 kW

183

4
0

0
%

10

20

30

40

50

Qm/h

40

JRN 205 18/7,5 - DN 50


+
JRN

205

-18

/7,5

183

20

12
8L
4
0
0

40
10

60
15

100 Qm/h

80
20

20
16
12
8
4
0

Ql/s

25
183

20

40

60

80

100 Qm/h

%
60

183

60

100 Qm/h

80

10

Ql/s

12,5

60

40
30

40

Qmin

50

205-1

20

Hm

30

183

40
20

20
0

166

%
60

166

40

P2 kW

/5,5

60

-16

15

/5,5

2
0

-17

205

20

0
P2 kW
12

166

205

NPSH m

P2 kW
6

20

NPSH m

10

JRN

30

15

JRN

35

05

05

20

JRN 205 16/5,5 to

JRN 205 17/5,5 - DN 50


+

Qmin

45

NPSH m

Hm

10

20

30

40

50

Qm/h

20

40

60

80

100 Qm/h

11

LRN - JRN
HYDRAULIC PERFORMANCE JRN 2 POLE
Qmin

28

Hm

JRN 206 13/5,5 to

JRN 206 14/7,5 - DN 65

JRN 206-14/5,5

JR

N2

24

JRN

20
16

206

06-

24

14/

7,5

-13

/5,5

NPSH m

140
0

20

0
P2 kW

40

10

60
15

80

100 Qm/h

20

25

30Ql/s

20

40

60

100 Qm/h

80

/7,

3/5

,5

40

10

80

120

20

30

200 Qm/h

160
40

16
12
8
4
0

Ql/s

50
140
127

40

80

120

200 Qm/h

160

20

Qmin

35

30

40

60
40
20
0

100 Qm/h

50

JRN 206-16/5,5

JRN

25
20

-15/

80

120

JR

N2

25
20

5,5

06

JR

15

15

151
0
0

20
5

40
10

60
15

NPSH m

10

Qm/h
Ql/s

P2 kW
6
4

20

40

60

16
8
0

133

12
8
4
0

Qm/h

/7,

6-1

5/5

,5
151

151

20

-16

10

P2 kW

2
0

20

200 Qm/h

160

JRN 206 15/5,5 to

JRN 206 16/7,5 - DN 65


+

30

16/7,5

206

40

Qmin

35

206-

JRN

Hm

JRN 206 15/5,5 to

JRN 206 16/7,5 - DN 65

30

140

0
0

40
10

80
20

120
30

160

NPSH m

140

Hm

12

6-1

14

60
40
20
0

12
8N
L
4
0
0

6-

140

P2 kW

127

20

20

16
12
8
4
0

140

12

60
40
20
0

JR

16

JR

20

12

JRN 206 13/5,5 to

JRN 206 14/7,5 - DN 65


+

Qmin

28

NPSH m

Hm

Qm/h
Ql/s

40
151
133

40

80

120

160

Qm/h

%
151

20

40

60

Qm/h

60
40
20
0

151
0

40

80

120

160

Qm/h

20
16
8
0

LRN - JRN
HYDRAULIC PERFORMANCE JRN 2 POLE
24
20

JR

N2

12

08

-13

20
8

-14

/5,

/7,

P2 kW
6

NPSH m

133

50
10

75

100

20

Qm/h

125

133

25

50

75

125 Qm/h

100

8-

13

8-

14

/7

,5

/5

,5
133

50

100

150

20

250 Qm/h

200

40

20
16
12
8
4
0

Ql/s

60
133
121

50

100

150

250 Qm/h

200

%
60
40
20
0

12
8
4
0

2
0

20

20

P2 kW

121

20
16
12
8
4
0

Ql/s

30

JR

12

4
25

JR

16

JRN 208 13/5,5 to

JRN 208 14/7,5 - DN 80


+

Qmin

24
20

JR

16

Hm

JRN 208 13/5,5 to

JRN 208 14/7,5 - DN 80

Qmin

NPSH m

Hm

60
40
20
0

133

25

50

75

125 Qm/h

100

133

50

100

150

250 Qm/h

200

HYDRAULIC PERFORMANCE JRN 4 POLE


10

JR

N4

N4

JR

JRN

4
2

P2 kW
3

17/

10-

8
3

2,2

168
0

25

50
10

75

100

125 Qm/h
Ql/s

30

20

168

141
134

1
0

25

50

75

100

157

12
10
8
6
4
2
0

JR

P2 kW
6

JR

50

100
20

125 Qm/h

150

41

0-1

0-1

7/3

6/2

,2
168

250 Qm/h

200
0

4
0

41

N4
10
-15
10
-14 /1,5
,5/
1,1

N4

2
0

JR

141
134

%
60
40
20
0

JR

16/

N4
10
410 -15/1
,5
-14
,5/1
,1

2
0

10-

JRN 410 14,5/1,1 to

JRN 410 17/3 - DN 100


+

Qmin

10

NPSH m

JR

Hm

JRN 410 14,5/1,1 to

JRN 410 17/3 - DN 100

Qmin

50

100

150

200

NPSH m

Hm

12
10
8
6
4
2
0

Ql/s
168
157

250 Qm/h

%
168

25

50

75

100

125 Qm/h

60
40
20
0

168
0

50

100

150

200

250 Qm/h

13

LRN - JRN
LRN - ELECTRICAL CHARACTERISTICS AND SIZES
G
X

DN

II: pressure port G1/8


III: drain port G1/8

nx

mm

mm

n x mm

32

140

76

100

4 x 19

40

150

84

110

4 x 19

50

165

99

125

4 x 19

65

185

118

145

4 x 19

80

200

132

160

8 x 19

100

220

156

180

8 x 19

P2

III

II

D
mm

50

II

50
L

nx

18

60

DN
3xO

P1

10

ORDER
RFRENCE
REFERENCE
COMMANDE

P2

MOTOR
MOTEUR

Intensity*
Intensit*
3tri~400
400

Efficiency
Rendement

Cos

DN

*Check the information plate on the motor


when setting the thermal overload level.
PUMP
POMPE
H

P1

P2

mass
masse

kW

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

kg

LRN203-16/3

5.8

84.6

0.88

32

100

236

120

132

68

320

396

155

M10

20

160

150

217

46,1

LRN203-17/4

7.7

85.8

0.87

32

100

236

120

132

68

320

412

155

M10

20

168

150

232

53,4

LRN204-16/4

7.7

85.8

0.87

40

82

242

130

149

58

340

426

170

M10

20

168

150

232

57,3

LRN204-17/5,5

5,5

10.2

87.0

0.87

40

82

242

130

149

58

340

446

170

M10

20

168

150

279

68,6

LRN204-20/7,5

7,5

13.7

88.1

0.89

40

110

294

180

172

78

440

520

190

M10

20

188

150

279

80,6

7.7

85.8

0.87

50

105

232

140

130

40

340

463

150

M10

20

168

150

232

63,2

LRN205-16/5,5

5,5

10.2

87.0

0.87

50

103

279

164

143

48

340

526

170

M10

20

188

150

279

74

LRN205-17/5,5

5,5

10.2

87.0

0.87

50

103

279

164

143

48

340

526

170

M10

20

188

150

279

74,2

LRN205-17/7,5

7,5

13.7

88.1

0.89

50

103

279

164

143

48

340

526

170

M10

20

188

150

279

76,2

LRN205-18/7,5

7,5

13.7

88.1

0.89

50

120

295

160

170

70

440

521

190

M10

20

188

150

279

83

LRN206-13/5,5

5,5

10.2

87.0

0.87

65

120

279

140

140

60

340

531

160

M12

20

188

150

279

74,2

LRN206-14/5,5

5,5

10.2

87.0

0.87

65

120

279

140

140

60

340

531

160

M12

20

188

150

279

74,4

LRN206-14/7,5

7,5

13.7

88.1

0.89

65

120

279

140

140

60

340

531

160

M12

20

188

150

279

82,4

LRN206-15/5,5

5,5

10.2

87.0

0.87

65

110

279

180

195

60

430

532

215

M12

20

188

150

279

78,2

LRN206-16/5,5

5,5

10.2

87.0

0.87

65

110

279

180

195

60

430

532

215

M12

20

188

150

279

78,5

LRN206-16/7,5

7,5

13.7

88.1

0.89

65

110

279

180

195

60

430

532

215

M12

20

188

150

279

84,5

LRN208-13/5,5

5,5

10.2

87.0

0.87

80

105

279

180

173

57

400

548

200

M12

20

188

150

279

81,1

LRN208-14/7,5

7,5

13.7

88.1

0.89

80

105

279

180

173

57

400

548

200

M12

20

188

150

279

89,3

LRN410-14,5/1,1

1,1

2.45

81.4

0.8

100

120

356

200

226

60

500

398

250

M12

20

147,5

150

177

68,3

LRN410-15/1,5

1,5

3.3

82.8

0.79

100

120

356

200

226

60

500

423

250

M12

20

147,5

150

177

70,8

LRN410-16/2,2

2,2

4.7

84.3

0.8

100

120

356

200

226

60

500

450

250

M12

20

154,5

150

196

76,7

6.1

85.5

0.83

100

120

356

200

226

60

500

450

250

M12

20

154,5

150

196

84,1

LRN205-14/4

LRN410-17/3

14

LRN - JRN
JRN - ELECTRICAL CHARACTERISTICS AND SIZES
DN

nx

mm

mm

n x mm

32

140

76

100

4 x 19

40

150

84

110

4 x 19

50

165

99

125

4 x 19

65

185

118

145

4 x 19

80

200

132

160

8 x 19

100

220

156

180

8 x 19

D
mm

III

III

II

D
50

P2

P1

nx

50

3xO

II

10
ORDER
RFRENCE
REFERENCE
COMMANDE

P2

MOTOR
MOTEUR

Intensity*
Intensit*
tri 400

18

60

DN

Efficiency
Rendement

Cos

DN

*Check the information plate on the motor


when setting the thermal overload level.
PUMP
POMPE
H

P1

P2

mass
masse

kW

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

mm

kg

JRN203-16/3

5.8

84.6

0.88

32

100

539

360

43

137

320

393

155

M10

20

160

150

217

95

JRN203-17/4

7.7

85.8

0.87

32

100

539

360

43

137

320

409

155

M10

20

168

150

232

105,4

JRN204-16/4

7.7

85.8

0.87

40

100

587

400

52

145

340

413

170

M10

20

168

150

232

109,6

JRN204-17/5,5

5,5

10.2

87.0

0.87

40

100

587

400

52

145

340

433

170

M10

20

168

150

279

132

JRN204-20/7,5

7,5

13.7

88.1

0.89

40

110

692

500

38

192

440

515

220

M10

20

188

150

279

169,1

JRN205-14/4

7.7

85.8

0.87

50

105

532

360

52

148

340

463

170

M10

20

168

150

232

107,3

JRN205-16/5,5

5,5

10.2

87.0

0.87

50

120

619

360

50

130

340

503

180

M10

20

188

150

279

143,8

JRN205-17/5,5

5,5

10.2

87.0

0.87

50

120

619

360

50

130

340

503

180

M10

20

188

150

279

144,2

JRN205-17/7,5

7,5

13.7

88.1

0.89

50

120

619

360

50

130

340

503

180

M10

20

188

150

279

148,2

JRN205-18/7,5

7,5

13.7

88.1

0.89

50

120

693

500

50

200

440

521

200

M10

20

188

150

279

165,9

JRN206-13/5,5

5,5

10.2

87.0

0.87

65

120

619

400

50

150

340

521

170

M12

20

188

150

279

145,3

JRN206-14/5,5

5,5

10.2

87.0

0.87

65

120

619

400

50

150

340

521

170

M12

20

188

150

279

145,8

JRN206-14/7,5

7,5

13.7

88.1

0.89

65

120

619

400

50

150

340

521

170

M12

20

188

150

279

162

JRN206-15/5,5

5,5

10.2

87.0

0.87

65

152

679

440

55

185

430

521

215

M12

20

188

150

279

164,8

JRN206-16/5,5

5,5

10.2

87.0

0.87

65

152

679

440

55

185

430

521

215

M12

20

188

150

279

165,4

JRN206-16/7,5

7,5

13.7

88.1

0.89

65

152

679

440

55

185

430

521

215

M12

20

188

150

279

177

JRN208-13/5,5

5,5

10.2

87.0

0.87

80

155

630

400

62

178

400

528

200

M12

20

188

150

279

159,8

JRN208-14/7,5

7,5

13.7

88.1

0.89

80

155

630

400

62

178

400

528

200

M12

20

188

150

279

176

JRN410-14,5/1,1

1,1

2.45

81.4

0.8

100

180

801

580

80

250

500

397

226

M12

20

147,5

150

177

132,6

JRN410-15/1,5

1,5

3.3

82.8

0.79

100

180

801

580

80

250

500

407

226

M12

20

147,5

150

177

137,6

JRN410-16/2,2

2,2

4.7

84.3

0.8

100

180

801

580

80

250

500

423

226

M12

20

154,5

150

196

149,4

6.1

85.5

0.83

100

180

801

580

80

250

500

465

226

M12

20

154,5

150

196

164,2

JRN410-17/3

15

LRN - JRN
LRN - JRN OPTIONS

PARTICULARITIES

Sealing cap: For double pump. Blocks the opening left by the removal of the hydraulics section
and the motor.
Backflange:

Round to be soldered nominal press. 10/16 (sold individually).

Set of legs:

Used when fixing to a concrete support.

Models of pumps by
family

Sealing cap
Part reference

Backflange
Part reference

Set of legs
Part reference

203-17

2040971

82243

2040967

204-17

2040971

82244

2040967

204-22

2042861

82244

2040967

205-14

2040970

82245

2040967

205-17

2040971

82245

2040967

205-22

2042861

82245

2040967

206-14

2040970

82246

2040968

206-17

2040971

82246

2040968

208-14

2040970

82247

2040968

410-17

2040971

82248

2040968

a) Electrical
P2 = 3 kW: three-phase 400V Y 50 Hz

three-phase 230V 50 Hz

P2 4 kW: three-phase 400V 50 Hz

b) Installation
Mounted directly onto horizontal or vertical
pipework or on massif.
The system must provide protection of the
pump against bad weather and frost (do not
expose to direct sunlight or rain).

c) Packaging
Pumps delivered with backflange gaskets.

d) Maintenance
Repair: see the list of spare parts available on
the plan and cross-section.

ACCESSORIES
Sealing cap
Round backflanges to solder on
Set of support legs
Pressure measurement kit
Slave switch of protection motor (LRN)
Control and protection box (JRN)
Shut-off valves
Anti-vibration sleeves
Non-return valves

Special mechanical seal for 20 to 50% antifreeze if temperature is above 40C:


contact us for further details
.

MGP CONTROL BOX FOR JRN

For further information, see specific manual


for MGP boxes.

MGP

P1

P2

P1
P2
P1/P2

45

1~50/60Hz

MODE

P1 + P2
RESET

45


Controls motors and provides thermal
protection.
Safeguards operation by automatically starting the backup pump, if there is a fault on
the pump in service.

ON/OFF

160

58
67

16