Aqua-Aerobic Systems, Inc.: Surface Aerators
Aqua-Aerobic Systems, Inc.: Surface Aerators
Aqua-Aerobic Systems, Inc.: Surface Aerators
Surface Aerators
Q U A
E T
U R F A C E
E R A T O R S
SU
R F A C E
E R A T O R S
Features &
Benefits
Available in .7-75 kW
Single or dual speed
motor options
Flexibility in materials
of construction
Vibration controlled
design
Superior oxygen
transfer
Low maintenance
U A L I T Y
O M P O N E N T S
Q U A
E T
O M P O N E N T S
B
C
Motors are totally enclosed, fan cooled, and rated for severe
duty. The motors are constructed to Aqua-Aerobic Systems
specifications and are designed to meet the most stringent
operational requirements. Standard features include heavy duty
bearings and seals, class F insulation or better and a minimum
1.15 service factor. Total scheduled maintenance on an Aqua-Jet
aerator consists of motor bearing lubrication 2-4 times annually,
depending on motor size.
F
G
H
C
E
J
Fluid Deflector contains the thrust washer and protects the Antideflection insert from the upward liquid flow.
I
K
E
4
or fatigue results.
One-piece shaft of 17-4 PH (precipitation hardened) stainless
steel eliminates the use of couplings which require constant
lubrication with water or wastewater. The one-piece design
eliminates the erosion and constant maintenance problems
U A L I T Y
O N T R O L
Rotating
Aerator
0 Shaft
360
45
135
0 / 360
180
Propeller
225
315
45
90
135
180
225
270
315
A S E
I S T O R I E S
No matter what the application, municipal or industrial,
Aqua-Jet aerators provide unequaled reliability and
long-term performance.
**270
360
B
**
C
VELOCITY (PEAK)
AQUA-JET AERATORS
EC
EC
EC
/S
/S
/S
.0
.0
25
20
EC
EC
/S
/S
.0
.0
15
10
5m
EC
EC
/S
/S
5m
0m
7.
5.
2.
.30mm
.15mm
.10mm
.09mm
.08mm
.07mm
.06mm
DISPLACEMENT
PEAK TO PEAK-mm
.20mm
.05mm
.04mm
.03mm
60
200
100
400
300
600
500
800
700
1000
900
1200
1500
2000
1800
4000
3000
6000
5000
ACCEPTABLE FIELD VIBRATION LIMITS FOR VERTICLE PUMPS & HORIZONTAL PUMPS
WITH PIGGYBACK MOUNTED MOTORS (NON RIGID STRUCTURES)
A S E
I S T O R I E S
(Continued)
25 metric t/d
20,000 m3/d
Effluent Data
BOD
Suspended Solids
COD
Total P
Total N
20 mg/l
20 mg/l
150-250 mg/l
1.0-1.5 mg/l
2.0-3.0 mg/l
The use of fixed mounted, low-maintenance, direct-drive AquaJet aerators was required by the client and easy access more
than compensates for the additional cost of the concrete bridge.
Previous experience had shown that mechanical equipment with
gearbox and oil seals requires frequent maintenance and is
particularly vulnerable to breakdown.
Customer Comments
Nicolas Pombo, Corporate Environmental Engineer, said, If I
were to design another lagoon, definitely I would consider buying
Aqua-Aerobic again. No doubt about it. I think they are almost
maintenance-free. The mechanical performance is good.
Daily influent BOD levels average 180 ppm with effluent BOD at
5 ppm and BOD removal efficiency of .8 kg/kW/h at 80%
design flow. Operators at the Dos Cerritos plant report
functionally simple operation with reliable equipment and an
excellent maintenance record.
Typical wastewater treatment lagoon at a pulp and paper mill.
9
MO
O R I N G
P T I O N S
MO
O R I N G
P T I O N S (Continued)
;;;;;;
Applications:
Aerated lagoons
Aerobic digesters
Activated sludge basins
Equalization basins
10
C C E S S O R I E S
A
61.0
0.7
121.9
91.4
1.5, 2.2, 3.7
182.9
91.4
5.5, 7.5
182.9
91.4
11, 15, 18.5
182.9
91.4
22.5
182.9
30, 37.5, 45, 55 91.4
182.9
91.4
75
182.9
B
15.2
15.2
15.2
15.2
20.3
20.3
30.5
30.5
35.6
35.6
50.8
50.8
76.2
76.2
C
15.2
15.2
15.2
15.2
25.4
25.4
30.5
30.5
30.5
30.5
30.5
30.5
30.5
30.5
D
24.1
24.1
31.1
31.1
41.3
41.3
54.6
54.6
62.2
62.2
78.1
78.1
108.6
108.6
E
31.1
31.1
38.1
38.1
48.3
48.3
67.3
67.3
76.2
76.2
91.4
91.4
108.6
108.6
380 VOLT
F
17.8
17.8
17.8
17.8
22.9
22.9
27.9
27.9
33.0
33.0
40.6
40.6
48.3
48.3
415 VOLT
Arctic Pak
The Arctic Pak ring contains thermal resistance heaters which
minimize the chance of icing on the exposed surfaces of the AquaJet, such as the cast diffusion head.
The Arctic Pak is complete with its own junction box (which mounts
on the Aqua-Jet motor fan cover) and automatic controls and
control panel. Operation of the Arctic Pak is controlled by an ambient
temperature thermostat. The unit can be used on either floating or
fix-mounted Aqua-Jets.
Drawings and wiring diagrams are available on request. Contact your
Aqua-Aerobic Systems representative.
KW
FULL-LOAD
(50 Hz)
AMPS
.7
2.5
1.5
4
2.2
6
3.7
10
5.5
13
7.5
17
11
25
15
31
18.5
39
22
49
30
62
37.5
80
45
94
56
115
75
158
12-4
705
440
294
176
135
104
10-4
461
277
213
163
111
8-4
440
339
259
176
142
532
407
277
223
177
141
636
428
345
274
218
173
680
548
436
347
274
212
0-4
812
646
514
406
315
268
00-4
000-4 0000-4
807
642
507
393
335
274
199
650
504
429
350
255
303
955
764
603
464
400
327
239
772
594
511
419
303
360
12
C C E S S O R I E S
KW
WATTS
FUSE AT 220V
0.7
850
6.4 AMP
850
6.4 AMP
5.5, 7.5
1000
8.0 AMP
1250
10.0 AMP
22.5
2500
20.0 AMP
3350
25.0 AMP
75
5050
40.0 AMP
.7
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37.5
45
56
75
2.3
3.7
5.5
9.2
12.0
15.6
23.0
29.0
36.0
45.0
57.0
74.0
86.0
105
145
837
520
350
209
160
123
550
328
252
194
131
523
401
308
209
166
630
485
328
261
210
168
749
508
403
325
260
205
807
640
515
412
325
250
948
764
611
482
371
320
1. NOMINAL VALUES. SPECIFIC AMP RATING WILL VARY ACCORDING TO MOTOR MANUFACTURER.
2. ALLOWABLE AMPACITY RATING OF SELECTED CABLE SHOULD BE 125% OR MORE OF MOTOR FULL LOAD AMPERAGE.
STRAND
7 x 19
7 x 19
7 x 19
MATERIAL
304 STAINLESS
304 STAINLESS
304 STAINLESS
;;
;
;;
;
P E C I F I C A T I O N S
;;
;
;
;;
A
W/L
D
C
A
W/L
D
C
SS
Model
3000101
3000201
3000301
3000300
3000501
3000500
3000701
3000700
3001001
3001000
3001501
3001500
3002001
3002000
3002501
3002500
3003001
3003000
3004001
3004000
3005001
3005000
3006001
3006000
3007501
3007500
3010021
3010020
KW
(50 Hz)
0.7
1.5
2.2
2.2/.7
3.7
3.7/1.1
5.5
5.5/1.6
7.5
7.5/2.3
11
11/3.3
15
15/4.8
18.5
18.5/5.6
22.5
22.5/9.5
30
30/12.7
37.5
37.5/15.7
45
45/18.7
55
55/23.5
75
75/38.1
RPM
1500
1500
1500
1500/1000
1500
1500/1000
1500
1500/1000
1500
1500/1000
1500
1500/1000
1500
1500/1000
1500
1500/1000
1000
1000/750
1000
1000/750
1000
1000/750
1000
1000/750
1000
1000/750
750
750/600
Apprx.
Shpg.
Wt.(kg)
91
91
152
186
186
213
213
354
372
390
408
540
581
612
653
748
785
839
875
1,179
1,270
1,352
1,406
1,678
1,497
1,769
2,245
2,676
FSS Series
DIMENSIONS
A
88.1
*103.0
112.1
118.4
112.1
118.4
*131.3
137.7
131.3
141.3
*163.2
173.2
172.6
174.8
174.8
177.0
220.8
229.4
256.7
261.1
256.7
261.1
261.1
261.1
261.1
265.9
303.5
313.7
B
20.3
21.6
21.6
21.6
21.6
21.6
26.4
26.4
26.4
26.4
40.6
40.6
40.6
40.6
40.6
40.6
77.8*
77.8*
103.3*
103.3*
103.3*
103.3*
103.3*
103.3*
103.3*
97.9*
123.2*
118.1*
C
10.2
10.2
12.7
14.0
13.3
14.6
17.1
18.4
15.2
16.5
15.9
17.1
16.5
17.8
17.1
18.4
24.1
25.4
25.4
26.7
22.5
23.8
25.4
26.7
25.4
26.7
24.1
25.4
D
19.1
27.9
27.9
27.9
27.9
27.9
30.5
30.5
30.5
30.5
34.3
34.3
34.3
34.3
34.3
34.3
37.8
37.8
37.8
37.8
37.8
37.8
37.8
37.8
37.8
43.2
43.2
48.3
E
118.8
151.1
151.1
151.1
151.1
151.1
177.8
177.8
177.8
177.8
210.5
210.5
210.5
210.5
210.5
210.5
240.0
240.0
291.1
291.1
291.1
291.1
291.1
291.1
291.1
291.1
332.7
332.7
Mooring
Shaft Cable
Dia.
Dia.
2.2
3.18
3.18
3.18
3.18
3.18
4.45
4.45 5mm
4.45
4.45
5.40
5.40
5.40
5.40
5.40
5.40
5.40
5.40
6.35
6.35
6.35
6.35 6.5mm
6.35
6.35
6.87
6.87
9.98
9.5mm
9.98
FSS
Model
4200101
4200201
4200301
4200351
4200501
4200551
4200701
4200751
4201001
4201051
4201501
4201551
4202001
4202051
4202501
4202551
4203001
4203051
4204001
4204051
4205001
4205051
4206001
4207501
KW
(50 Hz)
0.7
1.5
2.2
2.2/.7
3.7
3.7/1.1
5.5
5.5/1.6
7.5
7.5/2.3
11
11/3.3
15
15/4.8
18.5
18.5/5.6
22.5
22.5/9.5
30
30/12.7
37.5
37.5/15.7
45
55
RPM
1500
1500
1500
1500/1000
1500
1500/1000
1500
1500/1000
1500
1500/1000
1500
1500/1000
1500
1500/1000
1500
1500/1000
1000
1000/750
1000
1000/750
1000
1000/750
1000
1000
Apprx.
Shpg.
Wt.(kg)
125
125
204
250
250
261
261
386
397
408
408
544
572
601
601
696
751
850
980
1020
1070
1160
1205
1250
DIMENSIONS
A
88.1
103.0
112.1
118.4
112.1
118.4
131.3
141.3
131.3
141.3
163.2
169.9
172.6
174.8
174.8
178.1
220.8
229.4
256.7
261.1
256.7
261.1
261.1
261.1
E T
B
21.6
21.6
21.6
21.6
21.6
21.6
26.4
26.4
26.4
26.4
39.4
39.4
39.4
39.4
39.4
39.4
76.2*
76.2*
103.3*
103.3*
103.3*
103.3*
103.3*
103.3*
C
10.2
10.2
10.2
11.4
12.7
14.0
15.2
16.5
14.0
15.2
15.2
16.5
17.8
19.1
20.3
21.6
20.3
21.6
25.4
26.7
25.4
26.7
26.7
26.7
D
17.8
27.9
27.9
27.9
27.9
27.9
30.5
30.5
30.5
30.5
35.6
35.6
35.6
35.6
35.6
35.6
39.4
39.4
37.8
37.8
37.8
37.8
37.8
37.8
E
118.8
162.6
162.6
162.6
162.6
162.6
180.3
180.3
180.3
180.3
213.4
213.4
213.4
213.4
213.4
213.4
240.0
240.0
291.1
291.1
291.1
291.1
291.1
291.1
Shaft
Dia.
2.2
3.18
3.18
3.18
3.18
3.18
4.45
4.45
4.45
4.45
5.40
5.40
5.40
5.40
5.40
5.40
5.40
5.40
6.35
6.35
6.35
6.35
6.35
6.87
Stainless Steel - SS
Dual Speed
Q U A
Mooring
Cable
Dia.
P T I O N S
Endura Series
Endura Series aerators offer a five-year nomaintenance warranty. This option is available on
2.2kw - 112kw AquaJet aerators. All Endura Series
are available in high efficiency, and each unit is
vibration tested and hydraulically designed for optimum
performance in the most stringent applications.
5mm
TY P I C A L A Q U A - J E T A E R A T O R O P E R A T I N G D E P T H S *
6.5mm
Dual Speed -
Materials of Construction
COMPONENT
MOTOR SHAFT
PROPELLER
MONOLITHIC CAST
DIFFUSION HEAD
FLOAT SKIN
FLOAT CONTENT
VOLUTE
INTAKE CONE
14
MODEL SERIES
STAINLESS STEEL
FSS
ONE-PIECE, 17-4 STAINLESS STEEL
316 STAINLESS STEEL, DYNAMICALLY BALANCED
304 S.S.
304 S.S.
WARNING: The Aqua-Jet aerator has a high velocity, upwardly directed hydraulic flow directly below the unit. In addition, horizontal surface velocities persist for some distance from the unit. These
flow patterns may, in some instances, cause damage to basin bottoms or walls creating leaking potential. In earthen or lined basins, Aqua-Aerobic Systems recommends the use of a concrete pad on the
basin bottom directly below the aerator. If concrete is known to be non-resistant to the waste, other material should be investigated. Rip rapping or similar means of bank protection can protect basin
walls. If basin contains toxic wastes, user is advised to obtain engineering advice as to basin design and construction necessary to prevent possible erosion and leakage. Aqua-Aerobic Systems assumes
no liability or responsibility for any damage to basin bottoms or walls, or for any injuries or damages resulting therefrom.
* NOTE: These charts are intended for approximation purposes only. Requirements are dependent on basin geometry, etc., and Aqua-Aerobic Systems should be contacted for specific applications.
* NOTE: Consult Aqua-Aerobic Systems for information on larger horsepower units.
15
Aqua-Jet
AquaPASS
Surface Aerators
Aqua-Jet II
AquaMB Process
AquaDDM
Aqua-Aerobic MBR
Membrane Bioreactors
Aqua MixAir
AquaDisk
Aeration Systems
AquaEnduraDisc
Aqua MiniDisk
AquaEnduraTube
AquaDiamond
AquaSBR
AquaABF
AquaExcel
ThermoFlo
AquaMSBR
IntelliPro
Copyright 2008