Contents
Introduction
Description of Function
Index
21
Contents iii
Introduction
Description of Function
Introduction 1
Main window
In the main window the most important measuring values are being recorded in
two diagrams. The upper diagram shows temperatures and CO2-concentrations
in function of time, the lower diagram shows the air pressure and the calculated
values of air density.
The time scale is being kept along with system time, so that always the newest
measuring values are visible in the diagrams.
On the right side of the main window the most recent measuring values are being
displayed as numerical values. On the right hand bottom the system time is being
displayed.
2 Description of Function
Navigation
By means of the navigation keys the diagrams can be enlarged, minimized and
moved. Approximately 3 minutes after the last operation of a navigation key the
diagrams will be changed back to factory settings.
Toolbar
Changes the diagrams back to factory
settings.
Temperature channel
Selection of the temperature channel.
The display of the measuring values
refers to the selected channel.
Description of Function 3
Table
In the window Table the measuring values are being displayed in a tabular
way.
4 Description of Function
Control elements
Selection of sensors (in the factory
setting only one sensor is
available).
Selection of data type to be
displayed. If no selection is made
by checking the respective box, all
measuring values will be
displayed.
Period of time, for which the
measuring values are to be
displayed. If the checkbox date /
time is not marked, all data will be
displayed.
Navigation within the table of
measuring values (first value,
previous value, next value, last
value).
Update table (refresh). New
measuring values will be
displayed.
Export current table. The displayed
table will be exported as a commaseparated ASCII-file (Excel
compatible).
Close window.
Description of Function 5
Special Table
The window Special Table allows the display of measuring values with the
same time value side by side.
6 Description of Function
Description of Function 7
8 Description of Function
Properties
Program settings can be carried out in the window Properties. The most
important settings are briefly explained below. It is generally necessary to be
careful when changing settings. A false configuration can easily cause the
system not to function correctly anymore. Only change settings when you are
sure what consequences these changes can bring with them.
The most important settings are briefly explained below.
Register General
Clock:
Database:
Description of Function 9
Register Diagram
10 Description of Function
Diagrams:
Standard display:
Zoom:
In this register you can chose which measuring parameters will be displayed.
When the checkbox has been marked the respective parameter will be displayed
as long as corresponding measuring values are present in the database.
ATTENTION
The settings for Sensor Id and Data Type Id may only be changed in
special cases. Wrong settings can result in the display of wrong measuring
values!
Sensor Id:
Description of Function 11
12 Description of Function
Register Chart
Series:
Titles:
Legend:
Panel:
Description of Function 13
Register Series
Format:
Point:
Marks:
Register Print
The register Print is not activated.
14 Description of Function
Description of Function 15
Terminal window
The terminal window shows the communication between Met Journal and the
sensor.
16 Description of Function
Lock Connection:
Send:
Configuration:
Close:
Configuration window
The configuration window shows the current configuration settings, which can
be adjusted.
The settings for the interface will be entered in the register Communication.
Register General
Station:
Description of Function 17
Register Database
18 Description of Function
Erase Data:
Archive Data:
Connection:
Archive Connection:
Register Sensors
Description of Function 19
New Sensor:
SxAxx:
Register Communication
20 Description of Function
Log Communication:
Poll Period:
Index
A
Adjustment of the diagrams 13
C
Configuration window 17
D
Description of Function 1
I
Introduction 1
M
Main window 2
MetJournal Klimet A30 1
MetJournal Station (Service) 15
P
Properties 9
S
Special Table 6
T
Table 4
Terminal window 16