Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Customer : IGO

Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER


** ON A/C ALL

21-26-43 - FILTER - DEMISTER


21-26-43 PB 401 CONF 02 - FILTER ASSY - AVIONICS VENTILATION - REMOVAL/INSTALLATION
TASK 21-26-43-000-003-A
Removal of the Filter Assembly
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
REFERENCE
No specific
No specific

QTY
DESIGNATION
AR ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
AR SAFETY CLIP - CIRCUIT BREAKER

B. Work Zones and Access Panels


ZONE/ACCESS
824

ZONE DESCRIPTION

C. Referenced Information
REFERENCE
21-26-43-920-001-A
24-42-00-861-001-A
Filter Assembly SHEET 1

DESIGNATION
Discard the Filter Cartridge (PALL)
Energize the Ground Service Network from the External Power

CAUTION: USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT
SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE
DAMAGE TO ELECTRICAL EQUIPMENT.
3. Job Set-up
Subtask 21-26-43-861-070-A
A. Energize the ground service network (Ref. AMM TASK 24-42-00-861-001) .
Subtask 21-26-43-865-072-A
B. Open, safety and tag this(these) circuit breaker(s):
PANEL
49VU

DESIGNATION

FIN

LOCATION

AIR COND/AVNCS VENT/CTL

6HQ

D06

49VU

AIR COND/AVNCS VENT/CTL

5HQ

D05

122VU

AIR COND/AVNCS/VENT/MONG

3HQ

Y17

123VU

AVNCS VENT/BLOWER/FAN

1HQ

AD10

123VU

AVNCS VENT/EXTC/FAN

2HQ

AE02

Subtask 21-26-43-010-063-A
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the avionics-compartment aft door 824.
(2) Open the access door 824.
4. Procedure
(Ref. Fig. Filter Assembly SHEET 1)
Subtask 21-26-43-020-060-B
A. Removal of the Filter Assembly
(1) Remove the filter (Ref. AMM TASK 21-26-43-920-001) .
NOTE: Close the door and lock the two elastic-fastener devices for the removal of the body.

Print Date: October 6, 2013 Local Time

Page 1 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER


(2) The filter body weighs approximately 9 kg (20 lb). Make sure that you support it correctly.
(3) Remove the clamps (4).
NOTE: Do not discard the clamps (4). You must keep and use them during the installation procedure.
(4) Move the flexible sleeve (5) on the duct to disengage the filter body (3).
(5) Remove the clamp (7).
(6) Release the drain hose (6).
(7) Remove the nut (9), the washer (10) and the screw (11) that attach the bonding strap (12).
(8) Remove the nuts (2) and the screws (1).
(9) Remove the filter body (3).
(10) Put blanking plugs on the disconnected line ends.
TASK 21-26-43-400-003-A
Installation of the Filter Assembly
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
REFERENCE
No specific

QTY
DESIGNATION
AR ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE

B. Work Zones and Access Panels


ZONE/ACCESS
824

ZONE DESCRIPTION

C. Referenced Information
REFERENCE
21-26-43-920-001-A
24-42-00-861-001-A
24-42-00-862-001-A
52-41-00-410-002-A
Filter Assembly SHEET 1

DESIGNATION
Discard the Filter Cartridge (PALL)
Energize the Ground Service Network from the External Power
De-energize the Ground Service Network Supplied from the External Power
Close the Avionics Compartment Doors after Access

CAUTION: USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT
SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE
DAMAGE TO ELECTRICAL EQUIPMENT.
3. Job Set-up
Subtask 21-26-43-860-052-A
A. Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001) .
Subtask 21-26-43-010-067-A
B. Get Access
(1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position below the rear avionics compartment door (824).
(2) Make sure that the access door 824 is open.
Subtask 21-26-43-865-073-A
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANEL

DESIGNATION

FIN

LOCATION

49VU

AIR COND/AVNCS VENT/CTL

6HQ

D06

49VU

AIR COND/AVNCS VENT/CTL

5HQ

D05

122VU

AIR COND/AVNCS/VENT/MONG

3HQ

Y17

123VU

AVNCS VENT/BLOWER/FAN

1HQ

AD10

Print Date: October 6, 2013 Local Time

Page 2 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER

123VU

AVNCS VENT/EXTC/FAN

2HQ

AE02

4. Procedure
(Ref. Fig. Filter Assembly SHEET 1)
Subtask 21-26-43-420-060-B
A. Installation of the Filter Assembly
(1) Clean the component interface and/or the adjacent area.
(2) Do an inspection of the component interface and/or the adjacent area.
(3) Remove the blanking plugs from the disconnected line ends.
(4) Install the filter body (3).
(5) Install the screws (1) and the nuts (2). Do not fully tighten at this time.
(6) Attach the bonding strap (12) to the filter body (3) with the screw (11), the washer (10) and the nut (9). Tighten the nut (9).
(7) Install the drain hose (6).
(8) Install the clamp (7) and tighten.
(9) Tighten the screws (1).
(10) Install the flexible sleeve (5).
(11) Install and tighten the clamps (4).
NOTE: Use the clamps (4) kept during the removal procedure.
(12) Make sure that the attachments (8) are correctly tightened.
(13) Release the two fastener devices, open the door and install the filter as mentioned in (Ref. AMM TASK 21-26-43-920-001) .
5. Close-up
Subtask 21-26-43-410-063-A
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002) .
(3) Remove the access platform(s).
Subtask 21-26-43-865-074-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANEL

DESIGNATION

FIN

LOCATION

49VU

AIR COND/AVNCS VENT/CTL

6HQ

D06

49VU

AIR COND/AVNCS VENT/CTL

5HQ

D05

122VU

AIR COND/AVNCS/VENT/MONG

3HQ

Y17

123VU

AVNCS VENT/BLOWER/FAN

1HQ

AD10

123VU

AVNCS VENT/EXTC/FAN

2HQ

AE02

Subtask 21-26-43-862-071-A
C. De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001) .
TASK 21-26-43-920-001-A
Discard the Filter Cartridge (PALL)
1. Reason for the Job
Refer to the MPD TASK: 212643-07
DISCARD FILTER CARTRIDGE (PALL)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
REFERENCE

QTY

Print Date: October 6, 2013 Local Time

DESIGNATION

Page 3 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER


No specific
No specific

AR ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE


AR SAFETY CLIP - CIRCUIT BREAKER

B. Work Zones and Access Panels


ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
824
C. Expendable Parts
FIG.ITEM
3
filter cartridge

DESIGNATION

IPC-CSN
21-26-43-01-020

D. Referenced Information
REFERENCE
24-42-00-861-001-A
24-42-00-862-001-A
Filter Cartridge SHEET 1

DESIGNATION
Energize the Ground Service Network from the External Power
De-energize the Ground Service Network Supplied from the External Power

CAUTION: USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT
SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE
DAMAGE TO ELECTRICAL EQUIPMENT.
3. Job Set-up
Subtask 21-26-43-861-091-A
A. Energize the ground service network (Ref. AMM TASK 24-42-00-861-001) .
Subtask 21-26-43-865-093-A
B. Open, safety and tag this(these) circuit breaker(s):
PANEL

DESIGNATION

FIN

LOCATION

49VU

AIR COND/AVNCS VENT/CTL

6HQ

D06

49VU

AIR COND/AVNCS VENT/CTL

5HQ

D05

122VU

AIR COND/AVNCS/VENT/MONG

3HQ

Y17

123VU

AVNCS VENT/BLOWER/FAN

1HQ

AD10

123VU

AVNCS VENT/EXTC/FAN

2HQ

AE02

Subtask 21-26-43-010-080-A
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the access door 824.
(2) Open the access door 824.
4. Procedure
(Ref. Fig. Filter Cartridge SHEET 1)
Subtask 21-26-43-020-068-A
A. Removal of the Filter Cartridge
(1) Release the two fasteners (5).
(a) Move the locks (4) along the fasteners (5).
(b) Lift the fasteners (5) to release the door of the filter housing (1).
(2) Open the door of the filter housing (1).
(3) Pull up the strap to release the spring (2) from the locking block.
(4) Lower the spring (2) and disengage the filter cartridge (3) from the filter housing (1).
(5) Discard the filter cartridge (3).
Subtask 21-26-43-420-066-A
B. Installation of the Filter Cartridge
(1) Clean the inner sides of the filter housing (1).

Print Date: October 6, 2013 Local Time

Page 4 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER


(2) Engage a new IPC-CSN (21-26-43-01-020) filter cartridge (3) into the filter housing (1).
(3) Engage the spring (2) under the lip of the filter cartridge (3).
(4) Lift the cartridge (3) and attach the spring (2) on the locking block.
(5) Pull down the strap to lock the filter cartridge (3) in position.
(6) Close the door of the filter housing (1).
(7) Lock the two fasteners (5).
5. Close-up
Subtask 21-26-43-410-077-A
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the access door 824.
(3) Remove the access platform(s).
Subtask 21-26-43-865-094-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANEL

DESIGNATION

FIN

LOCATION

49VU

AIR COND/AVNCS VENT/CTL

6HQ

D06

49VU

AIR COND/AVNCS VENT/CTL

5HQ

D05

122VU

AIR COND/AVNCS/VENT/MONG

3HQ

Y17

123VU

AVNCS VENT/BLOWER/FAN

1HQ

AD10

123VU

AVNCS VENT/EXTC/FAN

2HQ

AE02

Subtask 21-26-43-862-090-A
C. De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001) .
Figure 21-26-43-991-01000-04-A / SHEET 1 - Filter Assembly
Figure 21-26-43-991-01800-04-A / SHEET 1 - Filter Cartridge

21-26-43 PB 501 CONF 02 - FILTER ASSY - AVIONICS VENTILATION - ADJUSTMENT/TEST


TASK 21-26-43-710-001-A
Operational Check of NRV for Free Movement and Confirm the Bowl is Clean
1. Reason for the Job
Refer to the MPD TASK: 212643-09
OPERATIONAL CHECK OF NRV FOR FREE MOVEMENT AND CONFIRM THE BOWL IS CLEAN
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
REFERENCE
No specific

QTY
DESIGNATION
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE

B. Work Zones and Access Panels


ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
824
C. Referenced Information
REFERENCE
21-26-43-100-001-A
24-41-00-861-002-A
24-41-00-861-002-A-01

DESIGNATION
Inspection of the Syphon Assembly (Strainer) for Cleanliness
Energize the Aircraft Electrical Circuits from the External Power
Energize the Aircraft Electrical Circuits from the APU

Print Date: October 6, 2013 Local Time

Page 5 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER


24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
24-42-00-861-001-A
Energize the Ground Service Network from the External Power
24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
Check Valve of the Avionics Ventillation Water / Dust Separation SHEET 1
3. Job Set-up
Subtask 21-26-43-865-087-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANEL

DESIGNATION

FIN

LOCATION

49VU

AIR COND/AVNCS VENT/CTL

6HQ

D06

49VU

AIR COND/AVNCS VENT/CTL

5HQ

D05

122VU

AIR COND/AVNCS/VENT/MONG

3HQ

Y17

123VU

AVNCS VENT/BLOWER/FAN

1HQ

AD10

123VU

AVNCS VENT/EXTC/FAN

2HQ

AE02

Subtask 21-26-43-941-067-A
B. Safety Precautions
(1) Make sure that the throttle control levers of the engines 1 and 2 are at idle.
Subtask 21-26-43-010-099-A
C. Get Access
(1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the access door 824.
(2) Open the access door 824 (Ref. AMM TASK 52-41-00-010-002) .
Subtask 21-26-43-861-086-A
D. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) .
Subtask 21-26-43-860-055-A
E. Aircraft Maintenance Configuration
(1) On the VENTILATION section of the panel 22VU:
- make sure that the BLOWER and EXTRACT pushbutton switches are in the AUTO configuration (pushed and with the FAULT and OVRD
legends off).
4. Procedure
(Ref. Fig. Check Valve of the Avionics Ventillation Water / Dust Separation SHEET 1)
Subtask 21-26-43-710-054-A
A. Operational Test of the Check Valve of the Syphon Assembly
NOTE: The energization of the aircraft electrical circuits starts a full test of the ventilation system. The test continues for 2 minutes approximately.
(1) Make sure that the bowl of the syphon is clean.
(a) If there are debris, clean the syphon assembly (Ref. AMM TASK 21-26-43-100-001) .
(2) Make sure that the ball of the check valve moves up.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002) .
Subtask 21-26-43-861-090-A
B. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001)
(1) Make sure that the ball of the check valve moves down.

Print Date: October 6, 2013 Local Time

Page 6 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER


5. Close-up
Subtask 21-26-43-410-092-A
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002) .
(3) Remove the access platform(s).
Subtask 21-26-43-862-086-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001)
Figure 21-26-43-991-01600-05-A / SHEET 1 - Check Valve of the Avionics Ventillation Water / Dust Separation

21-26-43 PB 701 CONF 02 - FILTER ASSY - AVIONICS VENTILATION - CLEANING/PAINTING


TASK 21-26-43-100-001-A
Inspection of the Syphon Assembly (Strainer) for Cleanliness
1. Reason for the Job
Refer to the MPD TASK: 212643-10
INSPECTION OF THE SIPHON ASSEMBLY (STRAINER) FOR CLEANLINESS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
REFERENCE
No specific
No specific

QTY
DESIGNATION
AR ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
AR SAFETY CLIP - CIRCUIT BREAKER

B. Consumable Materials
REFERENCE
11-001*
11-024*
11-031*

DESIGNATION
CLEANING AGENTS
NO LONGER AVAILABLE
CLEANING AGENTS
CLEANING AGENT, ALKALINE-WATER BASED.
CLEANING AGENTS
LIQUID SOAP

C. Work Zones and Access Panels


ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
824
D. Referenced Information
REFERENCE
24-42-00-861-001-A
24-42-00-862-001-A
52-41-00-410-002-A
Syphon Assembly SHEET 1

DESIGNATION
Energize the Ground Service Network from the External Power
De-energize the Ground Service Network Supplied from the External Power
Close the Avionics Compartment Doors after Access

CAUTION: USE ONLY THE GROUND SERVICE NETWORK TO SUPPLY ELECTRICITY BECAUSE THE AVIONICS VENTILATION SYSTEM IS NOT
SERVICEABLE. IF YOU ENERGIZE THE AIRCRAFT ELECTRICAL CIRCUITS WITHOUT THE VENTILATION SYSTEM YOU WILL CAUSE
DAMAGE TO ELECTRICAL EQUIPMENT.
3. Job Set-up
Subtask 21-26-43-861-089-A
A. Energize the ground service network (Ref. AMM TASK 24-42-00-861-001) .
Subtask 21-26-43-865-090-A
B. Open, safety and tag this(these) circuit breaker(s):

Print Date: October 6, 2013 Local Time

Page 7 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER

PANEL

DESIGNATION

FIN

LOCATION

49VU

AIR COND/AVNCS VENT/CTL

6HQ

D06

49VU

AIR COND/AVNCS VENT/CTL

5HQ

D05

122VU

AIR COND/AVNCS/VENT/MONG

3HQ

Y17

123VU

AVNCS VENT/BLOWER/FAN

1HQ

AD10

123VU

AVNCS VENT/EXTC/FAN

2HQ

AE02

Subtask 21-26-43-010-079-A
C. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below the access door 824.
(2) Open the access door 824.
4. Procedure
(Ref. Fig. Syphon Assembly SHEET 1)
Subtask 21-26-43-020-067-A
A. Removal of the Syphon Assembly
(1) Remove the twelve screws (2) and the washers (1).
(2) Remove the syphon assembly (3) from the filter housing.
Subtask 21-26-43-160-064-A
B. Cleaning of the Syphon Assembly
(1) Clean the inner floor of the filter housing and the area around the syphon assembly (3) with the Material No. 11-031* (CLEANING AGENTS) .
If necessary, use the non foaming Material No. 11-001* (CLEANING AGENTS) or, in very dirty areas, the Material No. 11-024* (CLEANING
AGENTS) (use this material at room temperature).
(2) Make sure that the plastic check valve (4) is clear of any debris.
(a) If there is debris, turn the check valve (4) to put the bottom up and flush the syphon with the flow in the opposite direction.
Subtask 21-26-43-420-065-A
C. Installation of the Syphon Assembly
(1) Install the syphon assembly (3) on the filter housing.
(2) Install the twelve washers (1), the screws (2) and tighten.
5. Close-up
Subtask 21-26-43-410-076-A
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the access door 824 (Ref. AMM TASK 52-41-00-410-002) .
(3) Remove the access platform(s).
Subtask 21-26-43-865-091-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANEL

DESIGNATION

FIN

LOCATION

49VU

AIR COND/AVNCS VENT/CTL

6HQ

D06

49VU

AIR COND/AVNCS VENT/CTL

5HQ

D05

122VU

AIR COND/AVNCS/VENT/MONG

3HQ

Y17

123VU

AVNCS VENT/BLOWER/FAN

1HQ

AD10

123VU

AVNCS VENT/EXTC/FAN

2HQ

AE02

Subtask 21-26-43-862-089-A
C. De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001) .
Figure 21-26-43-991-01700-07-A / SHEET 1 - Syphon Assembly

Print Date: October 6, 2013 Local Time

Page 8 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER

Print Date: October 6, 2013 Local Time

Page 9 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER

824

2083HM
2082HM

N_MM_212643_4_ACP0_01_00

Figure 21-26-43-991-01000-04-A / SHEET 1 - Filter Assembly


** ON A/C ALL

Print Date: October 6, 2013 Local Time

Page 10 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER

824
2083HM
2082HM

BLOCK

BLOCK

N_MM_212643_4_ABM0_01_00

Figure 21-26-43-991-01800-04-A / SHEET 1 - Filter Cartridge


** ON A/C ALL

Print Date: October 6, 2013 Local Time

Page 11 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER

824

ASSEMBLY

N_MM_212643_5_ACM0_01_00

Figure 21-26-43-991-01600-05-A / SHEET 1 - Check Valve of the Avionics Ventillation Water / Dust Separation
** ON A/C ALL

Print Date: October 6, 2013 Local Time

Page 12 of 13

Customer : IGO
Type : A318/A319/A320/A321
Rev. Date : August 1, 2013

Manual: AMM
Selected effectivity: ALL

21-26-43 - FILTER - DEMISTER


824

2083HM
2082HM

N_MM_212643_7_AAM0_01_00

Figure 21-26-43-991-01700-07-A / SHEET 1 - Syphon Assembly


** ON A/C ALL

Print Date: October 6, 2013 Local Time

Page 13 of 13