Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

LoadbearingsheetT4530L905

Loadbearing sheets are suitable for roof decking, external roof sheeting and intermediate flooring, andthey can also be
usedasformworkforconcreteslabs.Forthemosteconomicaldesign,useRuukkisPoimuroofdimensioningsoftware.
Applications:
Industrialbuildings
Publicbuildings
Sportsvenues
Officebuildings
Renovationprojects

Theinformationonourwebsiteisaccuratetothebestofourknowledgeandunderstanding.Althougheveryefforthasbeenmadetoensure
accuracy,thecompanycannotacceptanyresponsibilityforanydirectorindirectdamagesresultingfrompossibleerrorsorincorrect
applicationoftheinformationofthispublication.Wereservetherighttomakechanges.
Copyright2015SSABoritsaffiliates.AllRightsReserved.

Documentprintedon15.06.2015

www.ruukki.com

LoadbearingsheetT4530L905

Properties

Thesmallarrowindicatesthesidewherecoatingisappliedonthesheet.
Note!Loadbearingsheetsaredeliveredwiththenarrowflangefacingupandwideflangefacingdown,checkifyouneedto
turnthesheetforinstallation.
Productproperties

RuukkiT4530L905

T=trapezoidalsheet

45=heightclass

30=flangewidth

L=loadbearingprofile

905=modularwidth

Height:

44mm

Modularwidth:

905mm

Thicknessesavailable:

0.6,0.7,0.9mm

Minimumlength:

500mm

Maximumlength:

15000mm

Typicalspan:

<3.5m

Qualitycontrol:

FactoryproductioncontrolaccordingtoEN14782andEN10901

Material:

HotdipgalvanizedS350GD+Zsteelsheet
GalvanizedaccordingtoEN10346
CoilcoatedaccordingtoEN101691

Tolerances:

Profilesheet:EN14782andEN10902

CEmarking:

AccordingtoEN10901

Executionclass:

EXC1andEXC2

LoadbearingsheetT4530L905

Materials
Thickness

Coating

Zinc

Corrosionclasses

Steelgrade

Weight

Colours

mm

Interior

Exterior

kg/m2

0.6

Plaingalvanized

Z275

C1C2

S320

6.51

0.6

Polyester25

Z275

C1C3

C2C3

S320

6.51

RR20

0.7

Plaingalvanized

Z275

C1C2

S350

7.59

0.7

Polyester25

Z275

C1C3

C2C3

S350

7.59

RR20

0.9

Plaingalvanized

Z275

C1C2

S350

9.76

0.9

Polyester25

Z275

C1C3

C2C3

S350

9.76

RR20

Protectionagainstcorrosion
Environment

Coating

InsidebuildingsinenvironmentswithcorrosivitycategoryC1,C2according
toENISO129442standardandA1,A2accordingtoEN10169standard

Steelsheetswithzinccoatingof100g/m2
andwithpolyestercoatingSP15,thickness
15m

InteriorapplicationsinenvironmentswithcorrosivitycategoryC1,C2,C3
accordingtoENISO129442standardandA1,A2,A3accordingtoEN
10169standard

Steelsheetswithzinccoatingof275g/m2
andwithpolyestercoatingSP25,thickness
25m

CorrosivitycategoriesaccordingtoENISO129442standard,examples
CorrosivitycategoryC1:
Interiorheatedbuildingwithcleanatmospheres,e.g.offices,shops,schools,hotels
CorrosivitycategoryC2:
Interiorunheatedbuildingswherecondensationmayoccur,e.g.depots,sportshalls
CorrosivitycategoryC3:
Interiorproductionroomswithhighhumidityandsomeairpollution,e.g.foodprocessingplants,laundries,breweries,
dairies
Exteriorurbanandindustrialatmospheres,moderatesulfurdioxidepollution.Coastalareaswithlowsalinity.
CorrosivitycategoryC4:
Exteriorindustrialareasandcoastalareaswithmoderatesalinity.
CorrosivitycategoriesaccordingtoEN10169standard(condensation),examples
CorrosivitycategoryA1:
Interiorofficebuildings,schools,residential(exceptkitchensandbathrooms),drystoragebuildings
CorrosivitycategoryA2:
Interiorsportshalls,cinemas,theatres,coldstores,supermarkets
CorrosivitycategoryA3:
Interiorkitchensandbathrooms,foodprocessing(e.g.bakeries),industrialbuildingswithdryprocess

Installation
Note!Whendelivered,thenarrowflangeoftheloadbearingroofingsheetfacesupwardsinthepackage,socheckifthe
sheetneedstobeturnedtobeinstalledcorrectly.

LoadbearingsheetT4530L905

For insulated roofing structures, the loadbearing sheet needs to be turned, asit isinstalled with the narrow flange
againstthesupport.Anexceptionistheanticondensationcoatedsheet,whichisdeliveredwiththewideflangefacing
upwards,whensemiwarmroofisinquestion.
Foruninsulatedroofs,thesheetisinstalledasdelivered,withthewideflangeagainstthesupport.

Services&options
Webperforation

Standardperforationgrade(within
perforationarea)is15%.Diameterof
perforationholesis3mmwhichare
spacedonthebasisofequilateraltriangle,
sideequals7.4mm.
Duetowebperforationofloadbearing
trapezoidalsheets,decreaseofstrength
parameterstakesplace.
Inordertodetermineloadcapacityof
perforatedprofiles,youarerecommended
tousePoimusoftware,whichenables
dimensioningandoptimizationof
trapezoidalsheetswithinstructure.

Acoustics
Whenyouneedreductionforreverberationtime,pleaseaskforfurtherinformationfromoursales.Ourloadbearingprofile
sheetsaretestedwithdifferentkindsofroofbuildupstomeetyourneeds.Wearenotlimitedtoonlysoundabsorption,our
expertsarealsoreadytoconsultyouregardingtheroofsoundinsulation.

Anticondensation
Whenbuildingcoldstorageorcarshelters,pleaserememberthatcondensationmightbeharmful.Toavoidthis,wecan
provideourloadbearingsheetswithanticondensationlayers.

Thecontentofthisdocumenthasbeencreatedfromwebpagelastupdated23Sep2013
Oursalesandtechnicalsupportarehappytogiveyoumoreinformation.Visitwww.ruukki.com/contactus.

You might also like