Professional Documents
Culture Documents
3G EMLPP Related Parameters 20151110
3G EMLPP Related Parameters 20151110
PARAMETER NAME
CongACSwitch
CongCheckPeriod
ACRstrctRange
ACPollPeriod
CongRejTrigThd
CongRejRelThd
CongOfUlLoadSwitch
UlLoadCongTrigThd
UlLoadCongRelThd
CongOfCpuSwitch
CpuCongTrigThd
CpuCongRelThd
RstrctR6PSMaxACNum
RstrctR5MaxACNum
RstrctR6CSMaxACNum
PPACSwitch
PgRspRestrictInd
LocationRegRestrictInd
LocationRegRestrictStat
DESCRIPTION
With Intelligent Access Class Control, the RNC adds the number of
restricted access classes if cell resources are congested. If cell
resources are no longer congested, the RNC reduces the number of
restricted access classes.
Cell congestion check interval. The RNC checks whether cells are
congested at this interval.
This parameter is an advanced parameter. To modify this parameter,
contact Huawei Customer Service Center for technical support.
Range of restricted access classes. Access requests initiated by UEs
of specific access classes specified by this parameter are rejected by
the RNC at the interval specified by "ACPollPeriod". For details about
"ACRstrctRange", see 3GPP TS 22.011.
Polling interval for access control. At this interval, the RNC rejects
access requests initiated by UEs of specific access classes, which are
specified by "ACRstrctRange".
This parameter is an advanced parameter. To modify this parameter,
contact Huawei Customer Service Center for technical support.
Threshold for cell congestion with the RRC or RAB setup request
rejection rate. When RRC or RAB setup request rejection rate in a cell
is equal to or higher than , the RNC regards the cell in question as
being congested.
Threshold for cell resource restoration with the RRC or RAB setup
request rejection rate. When this threshold is not exceeded, the RNC
regards the cell in question as not being congested.
Whether to consider the RAB setup request rejection rate when
making cell congestion decisions.
This parameter is an advanced parameter. To modify this parameter,
contact Huawei Customer Service Center for technical support.
Uplink cell power load threshold for cell congestion. When uplink
power load in a cell is equal to or higher than this threshold, the RNC
regards the cell in question as being congested due to high uplink
cell power load.
This parameter is an advanced parameter. To modify this parameter,
contact Huawei Customer Service Center for technical support.
Uplink cell power load threshold for cell resource restoration. When
this threshold is not exceeded, the RNC regards the cell in question
as being not congested due to reduced uplink cell power load.
This parameter is an advanced parameter. To modify this parameter,
contact Huawei Customer Service Center for technical support.
CPU usage threshold for cell congestion. When CPU usage on an SPU
subsystem is equal to or higher than threshold, the RNC regards cells
served by the SPU subsystem as being congested.
This parameter is an advanced parameter. To modify this parameter,
contact Huawei Customer Service Center for technical support.
CPU usage threshold for cell resource restoration. When CPU usage
on an SPU subsystem is lower than this threshold, the RNC regards
cells served by the SPU subsystem as not being congested.
This parameter is an advanced parameter. To modify this parameter,
contact Huawei Customer Service Center for technical support.
Maximum number of restricted access classes. This parameter is
used when UEs of R6 or later initiate PS-oriented RRC connection
requests. When this parameter is set to 0, no access classes are
restricted.
Maximum number of restricted access classes. This parameter is
used when UEs of R5 or earlier initiate RRC connection requests.
When this parameter is set to 0, no access classes are restricted.
Maximum number of restricted access classes. This parameter is
used when UEs of R6 or later initiate CS-oriented RRC connection
requests. When this parameter is set to 0, no access classes are
restricted.
MO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLCONGACALGO
UCELLPPAC
UCELLPPAC
UCELLPPAC
UCELLPPAC
PARAMETER SETTING
Turn onCongACSwitchfor cells where this feature is planned to be activated.
This parameter must be configured whenCongACSwitchis set toON. The value recommended for this
isAC0,AC1,AC2,AC3,AC4,AC5,AC6,AC7,AC8, orAC9. You are not advised to selectAC10for this pa
UEs fromAC0toAC9and UEs without an IMSI are not allowed to initiate emergency calls in this cell.
Congestion trigger threshold of the RRC/RAB setup rejection rate. The smaller the parameter value, th
number of barred ACs. The default value is recommended for this parameter. You can also set the valu
expectations on the network KPI.
Congestion release threshold of the RRC/RAB setup rejection rate. The smaller the parameter value, th
number of barred ACs. The default value is recommended for this parameter. You can also set the valu
expectations on the network KPI.
If the RRC admission threshold is higher than the RAB admission threshold, there is a possibility that t
RAB setup rejection rate is high. In this case, system resources are wasted. To prevent this problem, yo
onCongOfRABRejRateSwitchso that the RAB setup rejection rate is considered during the cell congest
Turn on this switch only when you want to take the uplink power load congestion as a necessary condi
This parameter is valid only whenCongOfUlLoadSwitchis set toON. The default value is recommended
This parameter is valid only whenCongOfUlLoadSwitchis set toON. The default value is recommended
Turn on this switch only when you want to take the SPU CPU usage as a necessary condition for increa
This parameter is valid only whenCongOfCpuSwitchis set toON. The default value is recommended fo
This parameter is valid only whenCongOfCpuSwitchis set toON. The default value is recommended fo
Remarks
PARAMETER NAME
DESCRIPTION